3-PHASE METER SUCKET OR BASE 7 JAW NEUTRAL - PAANO ANG PAGKABIT NITO? [English CC] | Rey electrical

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • 3- Phase Meter Base 7 Jaw with Neutral. Paano magkabit ng meter base na 3 phase?
    -- English Subtitles are now available! --
    Get updated with what Rey electrical does √
    FB Page: / reyelectrical633
    Instagram:
    ...
    • Check my other videos here! •
    Rey garden √
    • Playlist
    Rey blupers / bloopers √
    • Playlist
    Rey driver √
    • Playlist
    Rey instructor √
    • Playlist
    Rey technician √
    • Playlist
    Rey mason √
    • Playlist
    Rey electrician √
    • Playlist
    Rey plumber √
    • Playlist
    Rey laboy muna √
    • Playlist
    Rey Lectures √
    • Playlist
    Rey trouble shooting tutorial √
    • Playlist
    Rey practical wiring √
    • Playlist
    Rey repairing √
    • Rey repairing
    #3PhaseMeterBase7JawNeutral
    #PagkabitNgMeterSucket

Комментарии • 108

  • @RamMetric
    @RamMetric 3 года назад +3

    Salamat boss sa video na dagdagan ang kaalaman ko sa electrical😍 good job.

    • @reyelectrical
      @reyelectrical  3 года назад

      Well come po, pa shot out narin po lods

  • @margenvlogtv09
    @margenvlogtv09 3 года назад +2

    Salamat sa pag share sir bagong kaalaman na naman

    • @reyelectrical
      @reyelectrical  3 года назад

      Salamat..pls. subscribe to my channel po...

  • @NilBetTV
    @NilBetTV 3 года назад +2

    Nice tuturial boss thank you for sharing

    • @reyelectrical
      @reyelectrical  3 года назад

      Welcome boss pa shot out narin po keep safe

  • @renzofficial2435
    @renzofficial2435 2 года назад +1

    nice tutorial master,

  • @kylehuntingmutya3150
    @kylehuntingmutya3150 3 года назад +2

    Idol salamat sa pag share po

    • @reyelectrical
      @reyelectrical  3 года назад

      Salamat di lodi pa shot out nmn po keep safe

  • @worldofgee
    @worldofgee 3 года назад +2

    Galing naman. Gusto ko to ereplay sa live ko mamaya, baka makatulong ako dumami pa fans mo sana makasali ka.

  • @joelcanas1218
    @joelcanas1218 Год назад +1

    No comment

  • @joymarlyn7134
    @joymarlyn7134 8 месяцев назад +1

    Mga Voss merun bang rectangular metervase na 3phase line to line 110V.?kung merun Anu po b Ang tawag dun

  • @markanthonynilo9198
    @markanthonynilo9198 2 месяца назад +1

    Sir ano pong size ng Allen wrench kailangan niyan? Salamat Po.

    • @reyelectrical
      @reyelectrical  2 месяца назад

      Di kona matandaan lods

    • @markanthonynilo9198
      @markanthonynilo9198 2 месяца назад

      @@reyelectrical 8.0 mm Allen Wrench.
      Nag kabit ako kahapon 6 18 '24.
      Salamat Sir for the video.
      Sana na include niyo sa description ang mga detalye para mas mapalawak pa natin ang mga nakaka alam at gustong matuto.

  • @user-bu2cg3cx5k
    @user-bu2cg3cx5k Год назад +1

    Sir ano ung ggamitin meter base pg 220v 3phse 5pin o 7pin salamat

  • @gilbertbeltran3802
    @gilbertbeltran3802 5 месяцев назад +1

    magkano po ang singilan ng labor sa commercial service entrance salamat po

  • @PamonricCagayandeOro
    @PamonricCagayandeOro 5 месяцев назад +1

    what if no neutral line from place. ano po pwede other solution?

    • @reyelectrical
      @reyelectrical  5 месяцев назад

      Body ground to ground road to neutral from DU

  • @edgarrabino8975
    @edgarrabino8975 Год назад +1

    sir png 400 volts po b yang metro?

  • @zachyjovs1645
    @zachyjovs1645 Год назад +1

    Pag walng neutral boss pwedi ba yung grouding ikabit sa terminal ng neutral?

    • @reyelectrical
      @reyelectrical  Год назад +1

      Hindi po need sa neutral line

    • @zachyjovs1645
      @zachyjovs1645 Год назад

      ​@@reyelectricalsaan boss makakabili nyan?

    • @zachyjovs1645
      @zachyjovs1645 Год назад

      @@reyelectrical ok lng ba yan gamitin sa 75 amps na panel boss,

  • @diskartpinoy7459
    @diskartpinoy7459 3 года назад +2

    Sending my full support bro. Keep it up. Sukli done

  • @edwinlacuesta2212
    @edwinlacuesta2212 4 месяца назад +1

    Saan ung ground dyn boss

  • @wenceslaojr.baguio8763
    @wenceslaojr.baguio8763 2 года назад +1

    Sir pwd po pa request ng metering turorials 4jaws and 5jaws meter base.

  • @RodelSantos-hd9vi
    @RodelSantos-hd9vi 2 месяца назад +1

    Magkano po sir ung presyo nyan Kasama ung rectangular meter base

  • @ErjonD323
    @ErjonD323 7 дней назад +1

    Gagana po ba yan pag wlang neutral sir

  • @joverberamo750
    @joverberamo750 2 года назад +1

    Boss kv2c meter form 16s 3-phse 120-480v. Pwed metering/ install sa 25kva x3 7620 prim /13.200/. 440 volts sec.

  • @precioustivar4363
    @precioustivar4363 2 года назад +1

    Sir tanung kulang po ok lng ba hndi mglagay ng ground sa metro 7jaws 16s. Hndi po kasi ngrereading

    • @reyelectrical
      @reyelectrical  2 года назад

      Gagana parin po yon kahit wala ground for safety purposes po ang ground

  • @SeigfredWall
    @SeigfredWall 3 года назад +2

    Anong maximum load ng mga ganyan master na klase sa mother meter.. Plug in put housing.

    • @reyelectrical
      @reyelectrical  3 года назад

      200 Amp master pls. Subcribe and godbless

  • @jeboy3480
    @jeboy3480 Год назад +1

    Boss pwde ba baliktarin yan ang tatlong wire tapos wala bang problema sa reading ng meter o susundin ba yong RYB color coding talaga

    • @reyelectrical
      @reyelectrical  Год назад

      Ok lang po kung wala namang kulay ang wire

  • @jhimbhelljohncatague9252
    @jhimbhelljohncatague9252 2 года назад +1

    Sir for neutral bayan pag kaka alam ko insulated yung neutral parang body ground naman po yan.. diba mag ka iba yung neutral sa body ground

    • @reyelectrical
      @reyelectrical  2 года назад +1

      Nice question sir. Pag meterbase magkasama tlaga nag neutral at Earth grounding sa body to prevent damage sa meter base if mag karoon ng ng lightning
      Maghihiwalay na ang neutral at ground pag dating sa panel Board

  • @albertopagliawan821
    @albertopagliawan821 3 года назад +1

    Sir ung body ground ddertso po ba xa sa lupa...sir if kung magkabaligtad ng taping ang line1 at line 2 nagkabaligtad po...mag rreading pa poba ang metro tnx po

  • @bobongnarkos8250
    @bobongnarkos8250 2 года назад +1

    Pag Base 7 Jaw po ba hindi na si Electric Provider ang nagbibigay ng Meter Base at Meter? Salamat po.

  • @angeleobaccay18
    @angeleobaccay18 2 года назад +1

    Boss problema din namin yan sa planta namin pano maginstall ng metro gamit ang cts kasi mataas ang load

  • @margenvlogtv09
    @margenvlogtv09 3 года назад +2

    Team teng bisaya

  • @angeleobaccay18
    @angeleobaccay18 2 года назад +1

    Boss may tanong lang ako pano kung gagamitan ng cts kasi mataas ang load 300 amp pwede bang recta un kahit walang cts

  • @jayarmortera5114
    @jayarmortera5114 Год назад +2

    Sir, panu yung connection pag yung gamit mong meter base is 120-480 pero yung power supply mo is 3phase lang na 220v ?? nag install po kasi ako meron naman po power sa load side pero wala pong reading sa metro?? black out po siya walang number?? patulong naman idol ..salamat

    • @reyelectrical
      @reyelectrical  Год назад

      Posible po sira metro nyo kaya nya hanggang 600 volts

    • @jayarmortera5114
      @jayarmortera5114 Год назад

      @@reyelectrical baka namali lang po ako ng wiring Sir ..paano po ba yung tamang wiring sa loob ?

  • @jojoregalado44
    @jojoregalado44 2 года назад +1

    Sir ask ko lang po saan madalas ginagamit ang 3 phase , ano advantage po nito ....

    • @reyelectrical
      @reyelectrical  2 года назад

      Commercial establishment mas makakamura sa kuryente kaysa sa single phase

    • @jojoregalado44
      @jojoregalado44 2 года назад

      @@reyelectrical thank you po

  • @kapaknerzvlogs5044
    @kapaknerzvlogs5044 2 года назад +1

    Yung 3phase na 9s pwede ba gawing single phase

  • @noelrosalesatilano8537
    @noelrosalesatilano8537 2 года назад +1

    Ilang CT ginamit nyo bossing? Current transformer

  • @engrmac2649
    @engrmac2649 2 года назад +1

    Boss, nakainsulate po ba yung busbar ng neutral wire sa meterbase?

    • @reyelectrical
      @reyelectrical  2 года назад

      Hindi po sir kasama sa body ground

    • @engrmac2649
      @engrmac2649 2 года назад +1

      pasensya na sir medyo di kasi ako familiar sa Electrical works, edi parang nagko-connect po dito ang Neutral sa grounding? tama po ba pagkakasabi ko? Please enlighten me boss, thank you

    • @reyelectrical
      @reyelectrical  2 года назад +1

      Ok lang sir subukan ko sagutin. pagganitong commercial stole na meter dina talaga siniseparate at neutral sa grounding same as residencial. Maghihiwalay nalang po ito sa panel board na bibilhin nyo na may dedecated para sa neutral and grounding.
      Pero kung papansinin nyo parehas naman ang pupuntahan nyan lahat sa earth grounding

    • @engrmac2649
      @engrmac2649 2 года назад +1

      Yown! thanks po Sir sa explanation, somehow enlightened na po. God bless po sa inyo at sa inyo pang incoming videos

    • @angelitorosauro3400
      @angelitorosauro3400 2 года назад

      @@reyelectrical boss umg neutral poh b naka bodyground

  • @manirejemston4024
    @manirejemston4024 3 года назад +1

    3 phase with neutral po ba yan boss

  • @magenciogudito5976
    @magenciogudito5976 2 года назад +1

    Sir tanung ko lng ano possible nasira nawala ang Display ng metro digital po salamat

  • @balongsabian5034
    @balongsabian5034 3 года назад +1

    boss yung neutral nya nakadikit sa base ng metro

    • @reyelectrical
      @reyelectrical  3 года назад

      Hindi po sir thanks for watching

    • @balongsabian5034
      @balongsabian5034 3 года назад

      @@reyelectrical hindi ba?pero sir tinester ko may continuety

    • @engrmac2649
      @engrmac2649 2 года назад

      meron nga pong continuity

  • @BrechtxavierNacase-wi1lv
    @BrechtxavierNacase-wi1lv Год назад

    Boss pano pag wlang neutral 3 phase line to line 220 three phase

  • @christianlegaspi6011
    @christianlegaspi6011 2 года назад +1

    Pwede ba yan sir Ikaw na mis mo bumili ng 7 jaw na base na yan or sa meralco tlga kinukuha yan

    • @reyelectrical
      @reyelectrical  2 года назад +1

      Pwede po kung wala binigay pero kung meron yon po ang gamintin nyo

  • @balongsabian5034
    @balongsabian5034 3 года назад +1

    wala po syang body ground?

  • @cvcadventure4476
    @cvcadventure4476 2 года назад +1

    Boss anong dimension nang Casing niya?. Yong rectangular

  • @cvcadventure4476
    @cvcadventure4476 2 года назад +1

    Anong po yong brand nong meter base

  • @lanzcabrera9266
    @lanzcabrera9266 2 года назад +1

    Boss wala nabang grounding yan?

    • @reyelectrical
      @reyelectrical  2 года назад

      Meron po sir connected sya sa neutral ng
      Service drop

  • @ianrosal1235
    @ianrosal1235 2 года назад +1

    tatlong 110v sir.baka 330v😅

  • @rickscua346
    @rickscua346 2 года назад +1

    boss kaya ba yan ng 100amp? saan nabibili sir?

    • @reyelectrical
      @reyelectrical  2 года назад

      Opo 200 Amp ang rating nito. Try nyo sa Mega Standard sa Caloocan search nyo nalang sa google

  • @edwindaling782
    @edwindaling782 2 года назад +1

    pag line to line 3 hase master saan yung ground

  • @erickcamba6291
    @erickcamba6291 2 года назад +1

    Sir nasaan ang ground connection niyan?

  • @christopherpunta6307
    @christopherpunta6307 2 года назад +1

    San Ung ground

  • @bertjhensaturinas8959
    @bertjhensaturinas8959 2 года назад +2

    Good day Sir.baka pwedi eh gawa nyo Po kami MGA baguhan Sir Ng schematic diagram tongkol nyan Sir. Para matoto kami. Salamat Sir. God bless

  • @gildocorpuz2928
    @gildocorpuz2928 2 года назад +1

    Mali naman yan turo hindi ka naman puede mag plus diyan na supply depende sa network supply

    • @lyndolestillore6002
      @lyndolestillore6002 2 года назад +1

      Tama, depende kung ilang voltage ang hihingin mo kay meralco meralco. Yong ibang outlet naglalagay sila ng sariling transformer for some purposes like stepdown voltage.

  • @djpamremix1159
    @djpamremix1159 5 месяцев назад +1

    sir pahingi ng email nyo o kaya contact number. naghahanap ako ng installer nyan.