LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING

Поделиться
HTML-код
  • Опубликовано: 27 авг 2024
  • НаукаНаука

Комментарии • 490

  • @honda9731
    @honda9731 3 года назад +19

    PROFESSIONAL LEVEL Explanation. Straightforward. You're right on the money. No Fake News, No BS. The information is like a finely aged whisky that smoothly goes right in. The whole video is priceless. Salute

  • @tonyrodriguez1983
    @tonyrodriguez1983 3 года назад +9

    Npakalinaw lahat ng explanation mo d2 Sir. Hindi lhat ng Electl Engr alam ang ineexplain mo. Ang swerte ng mga electrician na ma eeducate sa mga vlog m Sir. The best Practical Electricity vlog n napanood ko with a very nice attitude. Salute.

    • @practicalelectrical3837
      @practicalelectrical3837  3 года назад +1

      Salamat sir tony more power 👍

    • @MRGPH
      @MRGPH 2 года назад

      Madaming nag kalitihan Dyan kahit engineer na iba d Alam Yan master electrician pinagtatalunan Dyan kung Anu ba Ang Tama Sabi nmn Ng iba hiwalay dapat may project aq Ngayon balak ko e bonding Ang problema baka mag baliktad Ang lagay Ng lineman Ng coop imbis sa l one sa ground nalagay kung Tama nmn panu kung may bagyo tas Basta Basta nila kinakabit tapus bumaliktad

    • @jeosamcastv8457
      @jeosamcastv8457 2 года назад

      Sir gud evening...iilan palang ang na watch ko na tuturial mo peroalam ko marami akong matututunan sa iyo...d2 sa amin ang connection is line to ground...pero walang gumawa ng bonding ng grounded conductor sa ground.

  • @shadowken1214
    @shadowken1214 2 года назад +2

    Buti pa to libre nood madaming matutunan . Pero nung nag aral ako kulang namn sa turo sabihin pa magresearch kayo . . Langya.
    Kaya nakasubscribe na ako sir at no skip ads pambawi man lang. Salamat sa mga videos mo Sir malaking tulong po

  • @romelpogilokano
    @romelpogilokano 2 года назад

    Tama po ang vlog nyo. Sa first siurce of disconnect lang ang main bonding para maiwasan ang grounding parallel path tsaka maiwasan ang objectionable current. Master elwctrician po ako sa state ng Florida usa.

  • @monampuan2083
    @monampuan2083 3 года назад +6

    Subject was explained very well. great job of sharing or imparting of knowledge,skills and attitude. I can say very professional ang mode of delivery. This really a sound transformation of knowledge and i am pretty sure it contributes a lot to Filipino .

  • @armanparone2992
    @armanparone2992 2 года назад

    Subrang linaw ng paliwang mo idol,,. Salamat at marami kang naitamang mali, na akala ng iba ay tama.

  • @renzsandybuit2000
    @renzsandybuit2000 11 месяцев назад

    Sir. Ang galing nyo po. Napakagaling mag expalin at proper presmat. Para lang bumalik sa school. +1 subscription. Thanks

  • @josenisay4886
    @josenisay4886 Год назад

    Good morning sir … I’m high voltage electrician/ lineman and I started my job in rural electrician in the province sometime 60 years ago, now I’m still working the same job dealing with substation, underground transmission/ distribution & overhead lines.. thank very much for showing this information to your channel, you can save the life those curious people doing the wrong job… God bless & good day

  • @luso7487
    @luso7487 11 месяцев назад

    this is very informative. the most professional approach I've watched so fsr here on youtube. im an undergraduate in EE and from time-to-time i watch videos like this since im also a practicing electrician myself. i always advice electricians to religiously follow PEC standard whenever they are engaged in electrical installations because honestly, i encountered a lot of electricians who doesn't care about PEC standards. i will recommend this channel for them to learn the proper practice.

  • @astuvlog8360
    @astuvlog8360 Год назад

    Mabuti nalang may vlog na ganto na napakalinaw. Thankyou sir sa mga vlog nyo

  • @rawfytabigue8838
    @rawfytabigue8838 3 года назад +1

    Master magandang araw sayo maraming salamat napakahusay mong mag explain tungkol sa grounding connection sa.line to ground system connection sana hindi ka magsawang gumawa na mga vedeo tungkol sa electrical na naka base pec palagi akong mag aabang sa mga darating pang mga vedeo master mabuhay ka.master god bless you always.

  • @zfaj2168
    @zfaj2168 2 года назад

    Napakagandang video. Super educational, clear graphic presentations and nice pa boses ng speaker.

  • @josephferdinandmanal6485
    @josephferdinandmanal6485 3 года назад +2

    Ang ganda, well explained lahat. Can't wait sa topic ng SPD, kasi halos lahat ng nakikita ko sa web TT and TNS connection.

  • @nishanytjourney0609
    @nishanytjourney0609 2 года назад +1

    Marame po ako natutunan sainyo master more video po sana wag kayu mag sawa

  • @plrtv3362
    @plrtv3362 3 года назад +1

    tnx master dami ko napanood sa youtube pero isa to sa mga napakainformative malinaw pagkaka explain

  • @26apauapau
    @26apauapau Год назад

    Gusto ko talaga matuto mag electrician. Very informative.

  • @marloubernante6233
    @marloubernante6233 2 года назад

    Laki ng tulong neto lalo sa katulad kong baguhan pa sa electrical installation🥰😍🥰😍

  • @ERNTify
    @ERNTify 2 месяца назад

    Napaka detalyado ang paliwanag...sugest ko lang sir, na gamitin mo ang ibang term sa sinasabi mong voltage drop para hindi malilito ang mga batang electrical practitioners kung ano ang VD

  • @jaspertv6080
    @jaspertv6080 Год назад

    Ang Ganda nang pg ka explain mu master ..na intindihan ko lahat .. maraming salamat ..more videos to Po master ..God Bless ..

  • @altsgaming3728
    @altsgaming3728 2 года назад

    Maraming salamat sa ganitong topic boss at Marami akung natutunan sayo. 👍👍👍👍👍👍👍
    God bless.

  • @oscarbalintong8887
    @oscarbalintong8887 3 года назад +1

    Idol malinaw ung paliwanag mo .ang iba kc magpailaw lang electrician na ang dating.

  • @rogeliobaguio6768
    @rogeliobaguio6768 3 года назад

    The best talaga to.hindi nakakasawa panuorin ang video nya.

  • @vonakidloft7603
    @vonakidloft7603 2 года назад

    Galing daminkung na tutunan.poh sa inio po kahit d po ako nag school. Inulit ulit kulang para maintindhan

  • @alexanderberondo1155
    @alexanderberondo1155 2 года назад

    Boss salmat sa iyung tutorials video may natutunan ako,,, atsa parang tama ang pagkaintindi samga dini discus mo khit hindi ako electirian nakaiitindihan ko, slmat boss may mga nattunan sau boss, tama marami sa youtube ,god bless you,, maaaring pa shout-out boss alex Berondo from general santos city

  • @bisdakmillennial
    @bisdakmillennial Год назад

    Understandable kahit sa hindi mga electrician . tnx

  • @rodolfoesmama7746
    @rodolfoesmama7746 3 года назад

    hindi ako electrecian pero yung green na earth for safety. zero volt the same sa neutral zero volt. yung ibang equipnent paghinawakan mo may narandaman kang static kaya importanti yung earth para hindi ka ma static. yan lng alam ko.this vedio is very helpful.

  • @greggybote6693
    @greggybote6693 3 года назад +2

    very educational at base talaga sa PEC, thank you and keep it going sir great job!

  • @SeigfredWall
    @SeigfredWall 2 года назад

    Magandang talakayan master... Sa tamang paglagay ng grounding system base sa PEC

  • @drichio901
    @drichio901 2 месяца назад

    Very Informative ! andami ko natutunan. Salamat !

  • @marcel195
    @marcel195 3 года назад

    Thank you po Sir sa mga malinaw na paliwanag. After watching this full video , dito ko rin nalaman ang sagot sa aking tanong kung pwedng kumuha ng 110 V between line to ground (hindi pala pwede). Now, i am convinced na mali yong napanood kong video nong ibang tao.

  • @jhefframos4416
    @jhefframos4416 2 года назад

    Ayos ang galing mo magpaliwanag master. More video pa master marami ka matutulungan

  • @rupertabulencia1905
    @rupertabulencia1905 2 года назад

    Been watching videos on electrical connections. This gave the most convincing & legitimate explanation. Thanks more video please!

  • @SAYDETV
    @SAYDETV 2 года назад

    Thanks po sa tutorial, marami akong natututonan about electrical.

  • @rhevinaragon8104
    @rhevinaragon8104 3 года назад +1

    Very nice presentation,, clear na clear,, very helpful. Thank you very much for sharing.

  • @adultdirtbag8605
    @adultdirtbag8605 3 года назад +1

    un 1ng pic, si philippine life. commoner lng din sya like many of us. ndi rin sya aware s mga standards especially mga foreign nat'ls cla. possible n un lng din cnabi s knila nun local n gumwa s bhy nila so nmisled lng din c philippine life blogger...

  • @xerlexie
    @xerlexie 3 года назад +1

    thank you very much sir sa info at knowledge na ni share mo,,tama ka napakaraming mali sa s inet at sa mga fb groups poser minsan,,,

  • @dheomoreno4013
    @dheomoreno4013 2 месяца назад

    Newbie ako gusto ko matuto nuod ako youtube dmi nd nag lalgay ng grounding.pero ito safety first....

  • @romycruz4498
    @romycruz4498 3 года назад +3

    for me though it's an additional expense. 3 wire is better than 2 wire. since there's is only 110 per line in 3 wire with respect to the neutral, while the 2 wire system is 220 agad ang isang linya which is more fatal when you accidentally touch the live wire. So safety wise mas maigi na ang 3 wire o line to line kaysa 2 wire or line to ground. You can't buy safety, sabi nila. Dapat ang mga videong ganito ang pinapanood imbis na tiktok. maraming diyers a pinoy na alam nila paano mag electrical wiring (marunong sila sa How)pero kulang sa kaalaman pagdating sa theory which is very important para alam nila ang why? salamat po and continue sharing. btw ubos ang dalawang ads :)

  • @williambaraoidan5754
    @williambaraoidan5754 Год назад

    nice sir,,ganda ng pag discuss mo,malinaw maiintindihan talaga sa marami

  • @josedelsonpadernal4287
    @josedelsonpadernal4287 3 года назад +1

    Salamat sa kaalaman maituro ko rin some points sa mga trainee ko sa TESDA...god bless...

  • @Sak-en_Na
    @Sak-en_Na Год назад

    Ayos na ayos yong explanation mo Sir, thank you for your time and effort, sharing your understanding/expertise on the subject matter, watching your videos clarified some of the questions and other practices that are questionable not only to me but for sure to some other practitioner as well, Keep on uploading/sharing your thoughts it helps a lot.

  • @longado9276
    @longado9276 2 года назад

    Salamat po sir. Marami po akong natutunan. Request lang po sir, kung ok lang, kung paano naman po ang grounding sa mga barko. Salamat po ulit at God bless.

  • @paanovlog3296
    @paanovlog3296 Год назад

    Amdito lahar ng concern ko ,,nsagot pla dito maraming salamt master sa info😇nangamgarap din ako mging RME.soom😊

  • @gerryboypanot7344
    @gerryboypanot7344 3 года назад +2

    Nag enjoy po kami sir kahit mahaba..... Hehe.....

  • @rolandgonzales1178
    @rolandgonzales1178 3 года назад

    Thank you sir. Dame ko natutunan. From province palawan po ito.

  • @clarissarojo6540
    @clarissarojo6540 3 года назад

    Thanks sir..nalaman ko ang kahalagan ng grounding..

  • @matabuenajomel6279
    @matabuenajomel6279 3 года назад +1

    Very helpful video sir! well presented. Thank you and God bless.

  • @rhevnabol6432
    @rhevnabol6432 3 года назад

    Sir thank you po s mga binabhagi mo!!God bless po!!

  • @renantenava9425
    @renantenava9425 3 года назад +1

    Very informative and well explained Sir. Looking for more videos to come. Salute you Sir.Thanks

  • @christianvillanueva9102
    @christianvillanueva9102 3 года назад

    super gandan pa ka turo mu sir salamat sa vedio maramin ako natutunan

  • @jesteralubog5713
    @jesteralubog5713 3 года назад +1

    Nice sir... Sarap manuod ng video mo sir. Waiting for the next episode. 😊

  • @nenzki5819
    @nenzki5819 3 года назад

    Thank you. You deserve a subscribe. Panunuorin ko pa ang iba niyong mga video.

  • @ericcsonluy8140
    @ericcsonluy8140 3 года назад +4

    Mike Holt Jr of the Philippines.

  • @ritchiesvlogs9384
    @ritchiesvlogs9384 3 года назад

    Ang galing nyo po master idol salamat sa video ninyo kasi malaking tulong po ito sa kagaya Kong Isang electrician. naka subscribe at naka all bell napo ako sa channel nyo idol

  • @dreambelieve3920
    @dreambelieve3920 Год назад

    Salamat sa review line to ground

  • @practicalelectrical3837
    @practicalelectrical3837  2 года назад +5

    0:00 - Intro
    1:27 - Basic Connection
    3:38 - Neutral at Ground Main Bonding Jumper
    5:03 - Bawal ang Bonding sa Loadside
    7:54 - Grounding Rod Location
    9:12 - Service Equipment Grounding
    9:37 - Meter Base Grounding
    10:43 - Grounding Busbar
    11:54 - 1 Pole Circuit Breaker
    12:58 - 2 Pole Circuit Breaker
    13:56 - 1 Pole Fuse at Safety Switch
    15:56 - 2 Pole Fuse at Safety Switch
    17:24 - 2 Pole Fuse VIOLATION
    18:01 - 110V Volts sa Line to Ground???
    18:53 - Service Entrance Details
    19:35 - Meter Base Wiring Form 1S
    21:42 - Service Equipment and Feeder Details
    22:40 - Service Entrance Full Details
    22:49 - Utility Transformer and Distribution Details
    23:35 - TVSS or Surge Protective Device Requirement
    25:09 - Transformer General Wiring Details
    26:04 - VIOLATION: Color Coding
    27:31 - VIOLATION: Online Blog
    28:05 - VIOLATION: Walang Ground Wire
    29:36 - VIOLATION: Walang Bonding
    32:21 - VIOLATION: 2 Pole Fuse
    33:03 - VIOLATION: Nasa Grounded Wire ang Switch
    33:44 - VIOLATION: Ginawang Return ang Ground

    • @salvadorandes2152
      @salvadorandes2152 Год назад

      Sana gumawa kp sir ng iba pang video at e-post d2 sa YT. Marami kang natutulungang mga LEP, maging yung mga skilled non-LEP. Huwag magpa impluwensya sa mga taong gustong pagkakitaan yung talent mo sir. More power and more videos sir.

  • @anjunursal82
    @anjunursal82 Год назад

    Thank you sa content sir. More of this , MOre power

  • @ambotimo451
    @ambotimo451 3 года назад

    sir new subscriber here....doon sa part ng RCCB na sinabi mo yun ang ginamit kong installation ko sa bahay ko at satisfied naman ako kc effective talaga ang protection. pumipitik ang breaker ko very sensitive siya kaya kaya iwas sa sunog. at electroic shock...okay ung videos mo .thanks

  • @rommels.mendoza2423
    @rommels.mendoza2423 3 года назад +1

    Very informative . Interesting topics. Thanks.

  • @jamesianbracero1005
    @jamesianbracero1005 3 года назад +1

    salamat sa info boss. very informative.

  • @dennislopez9517
    @dennislopez9517 3 года назад

    Thank you sir ngayun ko lang napanuod ang video mo at napakaganda at linaw ng paliwanag mo.. watching in qatar

  • @securednetworxx
    @securednetworxx 3 года назад +1

    3:28 mark- correction po Master hindi yan kapareho ng TN-C-S instead is TT arrangement dahil ang na-provide ng Coop or Distribution going to your premise is only a Line & Earthed connection. It is now the responsibility of the consumer to provide for their own earth/ground connection thru earthing rod to distribute in its internal circuit of system for connection of exposed conductive part of any equipment. I do agree with you that a bonding is required as per PEC at the consumer side and that there will be a main earth/ground conductor that needs to be connected now to the earthing rod within your panelboard/consumer unit with earth/ground terminal blocks for each connection point like sockets /lighting making it 3 wires protruding so in case of Line to ground fault ay meron relief to the ground and it needs an RCD/RCCB/RCBO to clear that fault really and besides marami ang nakaka overlook nito na ang system impedance between Distributor earthing rod at consumer earthing rod ay mataas. So correction it’s not a TN-C-S(Terre Neutral Combined Separate)but a TT(Terre Terre). Isinama ko sa comment what the acronyms stands for the benefit of readers, which I know you know it no offense😁Thanks!

    • @rogelioparnes9861
      @rogelioparnes9861 2 года назад

      Hello sir the way you explain is you are expert and professional. May i ask po If its ok for not puting grounding at home. Dahil line to ground na po daw dito sa mindanao po? Pls. Clarify. Thank you!

  • @japormstamayocollado4196
    @japormstamayocollado4196 2 года назад

    Saklap.. dahil dyan marami na akong nakagawian na iiwasan ko na

  • @securednetworxx
    @securednetworxx 3 года назад +1

    I salute you for hitting those cowboy electricians in you tube who’s trying to educate with little knowledge about our system without them knowing that it is a violation of the code and will result to death and damage to properties.

  • @john-bervacaro4428
    @john-bervacaro4428 3 года назад

    ganda ng pagkaka-explained very detailed at maganda ang diagram. thank you sir!

  • @atomsformula6984
    @atomsformula6984 3 года назад

    Salamat dito lods.. ang dami kong natutunan

  • @margaritosilaojr.9882
    @margaritosilaojr.9882 3 года назад +1

    Dami q ntutunan syo boss, god bless

  • @edgarrapisora2712
    @edgarrapisora2712 3 года назад

    Worth to watch.

  • @tacpayac5323
    @tacpayac5323 3 года назад +1

    thank you Sir waiting po s episode 5. sobrang linaw.

    • @practicalelectrical3837
      @practicalelectrical3837  3 года назад

      Salamat po. Yes sir. Next weekend sir. 👋

    • @jonesticatadala763
      @jonesticatadala763 2 года назад

      @@practicalelectrical3837
      Sir may itatanong po sna ako
      Regarding sa meterbase na GFTP 5JJAW
      kung pwede po ba tlga xa pang 3 phase

  • @mabinibacol766
    @mabinibacol766 Год назад

    Nice explanation sir.

  • @rolandomata9540
    @rolandomata9540 3 года назад

    Sir Khit mahaba yun video ok lng mi ntututunan nmn mga information.👍👍👍

  • @greatwarrior5035
    @greatwarrior5035 2 года назад

    Very informative... thank you so much po

  • @marjonbaron4748
    @marjonbaron4748 3 года назад

    Salamat sa pag share sir god bless you

  • @daisycluma8849
    @daisycluma8849 Год назад

    ❤Watching Abu Dhabi UAE

  • @manolitolaron8634
    @manolitolaron8634 2 года назад

    Thanks sir sa info I've learned a lot

  • @woodwayne6032
    @woodwayne6032 Год назад

    Maraming salamat sir 👷‍♂️
    Inspiring Rme po ako

  • @wilfredoalitao4284
    @wilfredoalitao4284 2 года назад

    ang linaw ng paliwanag mo sir.

  • @dingcabrera4416
    @dingcabrera4416 2 года назад

    Dito sa Batangas, specifically Batelec 1, napakadelikado ng kuryente. Isang hot wire na 440volts ang isang linya, then galing naman sa ground ang isa. Pag naliligo ka, nakatapak ka na bale sa isang linya. Isang line lang napadikit ka or nahulog sa yo, tapos ka.

  • @isranvin4478
    @isranvin4478 3 года назад +2

    Sir habang napapanood ko mga video mo pakiramdam ko mas magaling n ako s kinukuha naming electrician.hahaha

    • @practicalelectrical3837
      @practicalelectrical3837  3 года назад

      Hehe salamat sir 👍

    • @francetv5300
      @francetv5300 Год назад

      At kapag ikaw na ang pumalit sakanya pakiramdam mo rin para kang nakukuryente dahil sa presure ng trabaho 🤣🤣

  • @MRGPH
    @MRGPH 3 года назад

    ang linaw mo mag turo sir pang pro talaga

  • @arseniovaldez1812
    @arseniovaldez1812 3 года назад

    Sir tuloy sir!thank you sa update

  • @EngrJayCaps
    @EngrJayCaps 3 года назад +1

    Thanks for your informative videos Sir :)

  • @manueldomingo3159
    @manueldomingo3159 2 года назад

    Hello sir maganda ang iyog presentation lalo kong pinag interesan ang imparting of technical knowledge sa style na gamit mo practical talga accompanied by PEC gus to kita sir parang pumapasok ako sa course of Electrical Engineer Sir do you also entertain some inquiries? Pls just count me as your online student,

  • @lolody28
    @lolody28 3 года назад

    Master magandanghapon marami akong nalaman ngayon, sana po matulungan nyo pa ako tungkol sa line to ground

  • @edgarpayapaya7215
    @edgarpayapaya7215 2 года назад

    ganda ng explanation mo boss

  • @luffymonkey6609
    @luffymonkey6609 Год назад

    Napag aralan ko n yan sa book ni max pajardo hahaha!!

  • @genemonce3833
    @genemonce3833 2 года назад

    Ang form 2s na metro po ay 3wire single phase at ang form 1s po ay 2 wire single phase, kaya sa form 2S po ay kailangan gamitin ang dalawang coil para completo po ang mtering circuit

  • @lorainegoldycempron9537
    @lorainegoldycempron9537 3 года назад

    nice explanation... thank you boss..

  • @kingarthur9309
    @kingarthur9309 2 года назад

    New subscirber here! Na refresh ako master thanks..

  • @ronniebiadno1975
    @ronniebiadno1975 2 года назад

    nice....yan ang tama sir....good good

  • @benjaminmayuga122
    @benjaminmayuga122 2 года назад

    Salamat sa explanation sir

  • @rubendeguzmangarcia5371
    @rubendeguzmangarcia5371 2 года назад

    Thanks Sir for the basic information and knowledge on electrical grounding system that benefits every electrical practitioners. Unfortunately, it is sad to mention that major points (per latest PEC) are not being observed and considered at all in building elect. installation in the province (in my area):
    1. No equipment grounding conductors (EGC) or circuit protective conductor (CPC) installed. For single phase LN system, TNC is adapted even up to internal building installation which is dangerous in the event of fault or disconnected neutral.
    2. For street lighting system, steel poles are without bonding to earth. Earthing connection is provided by utility at point of supply only.
    3. Lightning protection system are not introduced for taller buildings. (above 3 floors)
    4. As part of technical documentation in electrical design, I observed that in the short circuit calculation, the determination of minimum Isc levels are not included (only the max KAIC level is determined). Such are used to classify MCB types (B, C, D, Z) or to calibrate
    MCCB magnetic trip settings if adjustable and electronic types.
    5. Other electrical standards such as method of installations and proper materials.
    I know that concerned authorities (LGU and Electric Coop) are approving and issuing electrical permits with the coordination of contractor/PEE. There is no proper implementation and work checked on the actual installation which are in violation of latest PEC provisions. This are my observations and comments as a retired OFW on the prevailing electrical practices here in my area and I hope that these malpractices can be corrected.
    RGG

  • @rjrich2322
    @rjrich2322 Год назад

    Ganyan din po,ang sinusunod sa mga European countries na ang Main Disconnect CB Panelboard ay bonded ang Neutral wire sa ground wire or TNC.Downstream ay TNS na which is EARTHING and NEUTRAL are separate.

  • @maragusanwelders7393
    @maragusanwelders7393 2 года назад

    Subrang thank you sir SA vlog mo napakalianw talaga . Dito po sa Amin sa probensia ay line to neutral tanong kolang po SA outlet ng Aircon sir kaylangan PABA maglagay Ng ground?salamat po and God bless you

  • @arindar4310
    @arindar4310 Год назад

    nakakamiss nga videos mo sir

  • @dms3813
    @dms3813 3 года назад +1

    Actually,sa probinsya,mas prefer ko na 2 pole ang ginagamit na breaker(mapa plug-in neutral or bolt on type) with identified trip link,dahil kapag may portable genset which is common na ginagamit pambahay,dahil i plug lang sa outlet,2 hot wires ang portable genset,kaya mas safe para di magbackfed sa Du/coop. Mostly naman sa atin ang available Panelboard sa mga hardware pang residential ay pang 2 pole w/o grounding bus..so kailangan talaga mag install ka ng grounding bus bonded sa gounded conductor/neutral at kailangan madisconnect ang Neutral/grounded conductor/PEN sa system ng coop pag gagamit ng portable generator.

  • @jazzlayne5993
    @jazzlayne5993 2 года назад

    IBANG KLASE BOSS HEHE PARANG NAG-AARAL NALANG DIN AKO SA TESDA NETO BOSS.
    SALAMAT AT NKITA KO RIN VIDEO MO.
    PANG-ADVANCE STUDY NARIN INCASE NA MAGAAPLY AKO SA TESDA
    THANK SO MUCH BOSS❤️❤️😊

  • @anagerl3822
    @anagerl3822 3 года назад

    Salamat po sayo sir, naliwanagan po talaga ako dito sa tutorial nyo po. Salute po sir.

  • @stephenmarkagripo6741
    @stephenmarkagripo6741 3 года назад +1

    Maraming salamat!!!!!

  • @rayyanbinabdullah6278
    @rayyanbinabdullah6278 3 года назад +1

    Galing mo Master