PRACTICAL ELECTRICAL KNOWLEDGE
The First Philippine RUclips Channel that covers the basics and most controversial topics about the Philippine electrical installations.
All are based on the Philippine Electrical Code (PEC) and relevant international standards unless otherwise specified.
Instagram: @eesnip
Facebook: Practical Electrical Knowledge
The First Philippine RUclips Channel that covers the basics and most controversial topics about the Philippine electrical installations.
All are based on the Philippine Electrical Code (PEC) and relevant international standards unless otherwise specified.
Instagram: @eesnip
Facebook: Practical Electrical Knowledge
SERVICE ENTRANCE POLE LATERAL SERVICE EQUIPMENT METER POLE CONNECTION - EP 12.1 PART 2
Part 2... Isang malalim na diskusyon tungkol sa common sa atin na paggamit ng service entrance pole kung saan ikinakabit ang meter at service equipment.
🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST
ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
🔗 Part 1 here:
ruclips.net/video/vunNWKiXKPM/видео.html&ab_channel=PRACTICALELECTRICAL
Chapters:
0:00 - Intro
1:02 - Meralco Requirements
2:23 - Service Protective Device vs Service Equipment
3:28 - Service Equipment on Pole
5:22 - Loadside Panelboard Grounding
6:45 - Pwede ba Hindi iGround?
7:50 - Branch Circuit Grounding
9:09 - Case 1 Meter and SE at Pole
9:45 - Case 2 Meter only at the Pole
11:45 - Service Entrance Conductors kasama ang Grou...
🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST
ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
🔗 Part 1 here:
ruclips.net/video/vunNWKiXKPM/видео.html&ab_channel=PRACTICALELECTRICAL
Chapters:
0:00 - Intro
1:02 - Meralco Requirements
2:23 - Service Protective Device vs Service Equipment
3:28 - Service Equipment on Pole
5:22 - Loadside Panelboard Grounding
6:45 - Pwede ba Hindi iGround?
7:50 - Branch Circuit Grounding
9:09 - Case 1 Meter and SE at Pole
9:45 - Case 2 Meter only at the Pole
11:45 - Service Entrance Conductors kasama ang Grou...
Просмотров: 30 349
Видео
SERVICE ENTRANCE POLE LATERAL - SERVICE PROTECTIVE DEVICE METER POLE CONNECTION PART 1 - EP 12
Просмотров 71 тыс.2 года назад
Isang malalim na diskusyon tungkol sa common sa atin na paggamit ng service entrance pole kung saan ikinakabit ang meter at service protective device. Tatalakayin din dito ang tungkol sa kaibahan ng service protective device at service equipment at kung paano ang implementasyon nga mga ito. Kelan nga ba required ang mga ito? 🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST ruclips....
LINE TO GROUND TWO 2 POLE BREAKER JUMPER WIRE - HIWALAY ANG ILAW AT OUTLET SA ISANG BREAKER EP 11.1
Просмотров 51 тыс.2 года назад
Sa video na ito, paguusapan naten kung pasado nga ba sa Philippine Electrical Code ang talamak na paggamit ng 2 pole breaker sa line to ground o line to neutral systems para pag hiwalayin ang circuito ng ilaw at outlets! Malalaman din dito kung ano nga ba ang tamang gagawin at mga rekomendasyon at iba't ibang klase ng mga breakers na pwedeng gamitin para makatipid at the same time in line sa at...
LINE TO GROUND TWO 2 POLE BREAKER RCBO RCCB GFCI NEUTRAL AT GROUND BONDING TAMANG CONNECTION EP 11
Просмотров 36 тыс.3 года назад
Sa video na ito, pag uusapan naten paano nga ba iimplement ang tamang paggamit ng 2 pole breaker sa single phase 2 wire line to ground o line to neutral system. Tatalakayin din saan at paano ang tamang bonding ng grounded conductor (neutral) at equipment grounding conductor pag may 2 pole na breaker lalo na ang mga RCBO, RCCB o GFCI. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST ...
LINE TO GROUND O LINE TO NEUTRAL CONNECTION METER CENTER GUTTER BOX GROUNDING SERVICE ENTRANCE EP 10
Просмотров 35 тыс.3 года назад
Sa video na ito, tatalakayin naten ang tungkol sa meter center na line to ground o line to neutral single phase 2 wire system. Full connection lahat ayon sa PEC at sa common practices. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
MERALCO SERVICE ENTRANCE HIGH RISE BUILDING ELECTRICAL MULTI METERING PER FLOOR METER CENTER EP 6.1
Просмотров 8 тыс.3 года назад
Isang mabilisang quick trial video lang ng ating multi metering per floor sa isang high rise building simula sa riser pole ni meralco papunta sa transformer vault tapos sa busduct riser hanggang sa makarating sa meter center per floor. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
LINE TO LINE METER BASE METER CENTER AYON SA PEC PAANO? SERVICE ENTRANCE GUTTER BOX GROUNDING
Просмотров 12 тыс.3 года назад
Sa video na to pag uusapan ang tungkol sa Line to Line Meter Center Multi Metering connection and wiring diagrams ayon sa Philippine Electrical Code (PEC) at NEC. Hango din rito ang mga best practices at common meter center standards ng mga DU like Meralco. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
LINE TO NEUTRAL AT GROUND - MULTI GROUNDED NEUTRAL SA DISTRIBUTION SYSTEM TRANSFORMER GROUNDING EP 8
Просмотров 19 тыс.3 года назад
Dito sa video na ito ay tatalakayin kung ano nga ba ang tunay na "multigrounded neutral" na ginagamit ng mga distribution utilities at rural coops sa Medium Voltage distribution systems sa bansa nateng Pilipinas. Parehas nga ba ito sa sinasabi nilang line to neutral at line to ground dito? At literal na ginawang ground ang neutral wire sa medium voltage??? PRACTICAL PHILIPPINE ELECTRICAL WEBINA...
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE - PAANO ANG TAMANG WIRING NG METER BASE METRO - EP. 7
Просмотров 76 тыс.3 года назад
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE - PAANO ANG TAMANG WIRING NG METER BASE METRO - EP. 7
METER BASE SA METER CENTER SERVICE ENTRANCE PEC BUSBAR CB GUTTER BOX MULTI METERING - EP. 6 MERALCO
Просмотров 80 тыс.3 года назад
METER BASE SA METER CENTER SERVICE ENTRANCE PEC BUSBAR CB GUTTER BOX MULTI METERING - EP. 6 MERALCO
LINE TO LINE CONNECTION SINGLE PHASE AYON SA PEC (MERALCO VECO SUPPLY) 110V PWEDE EP. 5
Просмотров 73 тыс.3 года назад
LINE TO LINE CONNECTION SINGLE PHASE AYON SA PEC (MERALCO VECO SUPPLY) 110V PWEDE EP. 5
LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING
Просмотров 279 тыс.3 года назад
LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING
GROUND WIRE SA SERVICE ENTRANCE AY KULAY WHITE O GREEN GROUNDING - EP. 3
Просмотров 45 тыс.3 года назад
GROUND WIRE SA SERVICE ENTRANCE AY KULAY WHITE O GREEN GROUNDING - EP. 3
NEUTRAL VS GROUND AYON SA PEC - TAMANG TERMINO (TAGALOG) - EP. 2
Просмотров 59 тыс.3 года назад
NEUTRAL VS GROUND AYON SA PEC - TAMANG TERMINO (TAGALOG) - EP. 2
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE SINGLE PHASE HISTORY AT PAGKAKAIBA BASE SA PEC - EP. 1
Просмотров 220 тыс.3 года назад
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE SINGLE PHASE HISTORY AT PAGKAKAIBA BASE SA PEC - EP. 1
Q&A: What happened here? (PVC Conduit Thermal Expansion)
Просмотров 1,7 тыс.4 года назад
Q&A: What happened here? (PVC Conduit Thermal Expansion)
Q&A: Transformer primary and secondary color coding required?
Просмотров 1,4 тыс.4 года назад
Q&A: Transformer primary and secondary color coding required?
Q&A: Why do we have 6 primary terminals on a pad mounted transformer?
Просмотров 3,7 тыс.4 года назад
Q&A: Why do we have 6 primary terminals on a pad mounted transformer?
Q&A: Is it required to disconnect the neutral or grounded conductor?
Просмотров 1,1 тыс.4 года назад
Q&A: Is it required to disconnect the neutral or grounded conductor?
Q&A: Is it okay to have 10 AWG wire for a 50A breaker for aircon units?
Просмотров 2,2 тыс.4 года назад
Q&A: Is it okay to have 10 AWG wire for a 50A breaker for aircon units?
Q&A: Grounding electrode conductor ferrous metallic raceway bonding
Просмотров 9264 года назад
Q&A: Grounding electrode conductor ferrous metallic raceway bonding
Is it permitted to run equipment grounding conductors (EGC) outside raceways or cable assembly?
Просмотров 3 тыс.4 года назад
Is it permitted to run equipment grounding conductors (EGC) outside raceways or cable assembly?
What is the maximum busway / busduct support spacings?
Просмотров 1,3 тыс.4 года назад
What is the maximum busway / busduct support spacings?
Why do we need drip loops for service entrance?
Просмотров 1,5 тыс.4 года назад
Why do we need drip loops for service entrance?
Risers Guarding and Protection near Ground
Просмотров 1,2 тыс.4 года назад
Risers Guarding and Protection near Ground
Sir, pwede ba sub metering wla ng NEMA diritso na sa panel ng rooms
Idol kapag ba line to line same pa din ng current?or alternating pa din ba ang flow ng kuryente?
please provide us the controller wiring diagram
sir can you make for 3phase kwhr meter installation.
sir ask ko lang po sir bakit po sa probinsya wlang nema 3r system?
thank you sa information God bless po
Very detailed explanation, God bless sir. Paano po sa solar ground setup?
Galing ng paliwanag u idol ur d best
Sir gud a.m ask Klang kung Yung neutral bar ba na insulation or nkabond mismo sa NEMA 3r metal enclosure sir?salamat sa pagsagot po sir
Meron coop dito sa davao gumagamit ng green sa service entrance po
Good day po..maraming salamat po sa kaalaman na binabahagi mo palagi..god bless po...❤
Sir pwede po pa request kung paano mag install ng grounding sa loob ng panel board halimbawa sir subpanel at kung paano yung pag connect ng Neutral line sa grounding. thanks po
Mag ka iba talaga mga Pinoy Kasi marami kalokohan ginagawa kaya sa atin my Sarili pusti at para Hindi mag jumperan dun sa iba Bansa kahit wla pusti kahit whole ilagay nila Ang panil box tiyak Wala jajamper
Sir yung Green at White White Pwede ba siya pag samahin na idikit yung wire? Yung drawing mo kasi magkadikit yung white at green.
kaya pala sa america sir line to neutral kasi ang source nila is 120v lang.so ang isa hot at ang isang wire connected sa neutral kaya 120v lang.sa atin line to ground kasi ang source natin is 240v.ang neutral floated lang .ang line o hot ungrounded din ang isang line grounded kaya line to ground.😊
Pwede po rin ba ilagay ang neutral sa cb?
Boss paki lagayan ng green check yong mga tamang picture sample mo, boss, magulo paliwanag mo.
Maraming salamat master dami kong natutunan. May tanong ako sir bago lang kase ako sa electrical at gusto ko sanang lagyan ng service equipment iyong service entrance ng kuryente nmin wala kase cb direkta iyong wire pasok sa bahay namin pasok sa main panel or iyong tinatawag na service equipment customer load side. Ang tanong ko sir kapag naglagay ba ako ng service equipment malapit sa gate namin syempre as per sa natutunan ko dito sa video mo lalagyan ko ng MBJ at sa busbar eh magkasama iyong grounded wire which is iyong white at iyong equipment grounded wire which is yong green color. Tanong is kung koten 60 amp ang gagamitin ko eh ok lang po ba iyon kahit alam natin na walang ground fault protection iyong koten cb. Kase overload at short circuit protection lang sya.
👍👍👍
Ano po height nya meter to nema3r?😊
standard ba sa DU na hindi magbigay ng grounded service conductor sa service entrance? Line to Line yung connection. tapos L1 and L2 lang ang naka terminate sa service entrance
bakit sa lugar sa amin sa mindanao sir.ang binigay lang sa amin line to line lang.wla pong neutral line para sa grounding conductor.gagana pa din sir kahit magbaon ka lang ng ground sa lupa kahit hindi nkakabit sa neutral line ? magtri trip po ba ang breaker pag may ground fault?
Sir tanong ko po kung same lang po ba ng ampere na Circuit Breaker ang ilalagay sa Service Protection Device at Service Equipment?
Sir gud pm ask lang po what is the ampere rating protection at service equipment
So if Big deal ang kung before or after ilalagay ang bonding ng EG at GC, paano yung 1P+N na RCBO? since iisa lang din ang mag ttrip sa kanya which is yung L, pero yung N niya is concutive parin ?? So kung condutive parin yung N, hindi ba parang useless kung before or after yung bonding ng EG at GC dahil either way condutive parin yung N pole?
As youtube viewer po pero hindi po ako electrician kundi may konting alam lang natuto lang sa mga tropa ng konti, pati electronics may konti. May tanong ako sir, yon bang sabi mo na Grounded Service Conductor or yong Bare Wire ay physically may continuity or zero resistance between sa Grounding Electrode, Service Equipment Enclosure o circuit breaker panel at sa iba pang service equipment? sana mabasa mo tanong ko sir
Bakit daming rules and requirements? bakit di na lang iisa, for safety purposes dapat iisa lang ang sinasabi mapa meralco ka, o province or cooperative, dapat lahat may protective part na lahat malapit man o malayo. Para sa safety and maintenance purposes dapat lahat ng connection points from utility service drop down to owners service conductors, bldg. ckt. breakers dapat lahat meron ng protective devises before and after. Di yong kanya kanyang batas or requirements. Tutal lahat nman yan for human, animal and equipment safety. Dami pang nalalamang PEC provisions requirements.
Boss saan po ba mka bili ng gutter box
Sir line to line yung samin pano tamang wiring niyan according code
Sir magandang umaga tanong lang po yung supply set up ng meralco ganyan na po ba talaga na floating neutral? kasi galing probinsya kasi ako. follow up question yung mga branches po ba pwedeng 2 pole bolt on parang yung grounded conductor is idadaan ko pa sa 2 pole main breaker ng panel
Boss bakit d ka na nag uupload ng Bago? Lodi kita sa ganito. Sana bumalik ka sa pag share ng knowledge
husay...
Mali ba gumitin Ng natural gray sa grounded wire ..
Sir pwedi pa explain po nito *two of three sets of 3 wire feeders or two sets of 4 wire or 5 wire feeders shall be permitted to utilize a common neutral
sir tatanong lang sana..magtrip kaya yong ganyang set-up..isang pole sa light isang pole sa CO tas labas yong neutral? dba naka design yong koten na breaker or royu para sa 2pole? safe po ba?
Boss poweba mag lagay Ng ground sa panel baord
Sir pwd po vha mag request pwd gomawa kanang vedio kung pa,Ano malalaman ang busted nah 3phase transformer banking po.kahit Isa or dalawa ang busted sir Basta 3phase po siya kuh pa Ano po siya I,trouble shoot...salamat po Kasi yong single transformer tang galan lang siya nang load side Pag e, energize mo sasabog yong fuse Ganon porin vha sa 3phase salamat po.
gudam sir. pwede ba gumamit ng service drop wire from 1st house to 2nd house?
Ask lang if pwedeng magpalit Yung pwesto Ng bus bar gutter at breaker gutter
Paano pag sa bahay lang
Pwede b mag MTS sa Service Panel?
dapat binibili ng gobyerno nyen yun mga ganitong content pra ituro sa students para kahit basic knowledge meron ang kabataan.
the neutral conductor is another term po is return?
master anu kaya dahilan bakit nung kumidlat amin lng electricfan na sira. tapos C.O na wla nmn load na sira. pero ung C.O na wlang load un lg kabila. almost 16feet mula sa wall breaker ang distance ng C.O ung wire pina daan ko sa kalsada. pero may PCV nmn. nagkataon lng kaya na amin ang bahay ang pinag daluyan 2 wire po line to Ground. o maykinalaman ung wire na pinadaan ko sa kalsada.
malinaw talaga master salamat
Mataas impedance ng ground? Tig coconsider po na 1 to 0 ohms ang ground/earth. Kaya nga tayo may grounding system para sa fault current, since easier path sya to travel, sa earth na lng mapupunta yung fault current Atska, dun po sa sinabi mo na safe pag hinawakan yung wire since wala namang potential difference. Meron po! From your hand to ground, meron pong potential difference, meron pong current na dadaan. But since may pathway rin na deritso sa ground, most of the current ay derikta sa ground. Kaya yung nararamdaman natin ay shock lng
Question po. Meron kaming electric oven na gusto pa naming gamitin sa lilipatan namin. Pinapalagyan ko po ng grounding lahat ng outlet sa kusina. Kung ang oven ay grounded sa metal chassis, ibig sabihin non ay magtitrip ang breaker? Sa existing na tinutuluyan namin ay hinde, pero ingat kami sa paghawak sa oven. Kasi kung ganun pala, dapat bawat outlet sa kusina ay dapat may sariling breaker para di lahat madamay dahil lang sa isang appliance.
Nice knowing sir. It means, there's no way we can use 3 wire systems like drier from u.s into 2 wire systems in urban areas?
how to make 120V receptacle in the philippines
makakagawa ba ako ng 120V, using L1 and that bare cable from the post?