EE
EE
  • Видео 33
  • Просмотров 1 080 082
SERVICE ENTRANCE POLE LATERAL SERVICE EQUIPMENT METER POLE CONNECTION - EP 12.1 PART 2
Part 2... Isang malalim na diskusyon tungkol sa common sa atin na paggamit ng service entrance pole kung saan ikinakabit ang meter at service equipment.
🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST
ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
🔗 Part 1 here:
ruclips.net/video/vunNWKiXKPM/видео.html&ab_channel=PRACTICALELECTRICAL
Chapters:
0:00 - Intro
1:02 - Meralco Requirements
2:23 - Service Protective Device vs Service Equipment
3:28 - Service Equipment on Pole
5:22 - Loadside Panelboard Grounding
6:45 - Pwede ba Hindi iGround?
7:50 - Branch Circuit Grounding
9:09 - Case 1 Meter and SE at Pole
9:45 - Case 2 Meter only at the Pole
11:45 - Service Entrance Conductors kasama ang Grou...
Просмотров: 28 971

Видео

SERVICE ENTRANCE POLE LATERAL - SERVICE PROTECTIVE DEVICE METER POLE CONNECTION PART 1 - EP 12
Просмотров 67 тыс.2 года назад
Isang malalim na diskusyon tungkol sa common sa atin na paggamit ng service entrance pole kung saan ikinakabit ang meter at service protective device. Tatalakayin din dito ang tungkol sa kaibahan ng service protective device at service equipment at kung paano ang implementasyon nga mga ito. Kelan nga ba required ang mga ito? 🔗PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST ruclips....
LINE TO GROUND TWO 2 POLE BREAKER JUMPER WIRE - HIWALAY ANG ILAW AT OUTLET SA ISANG BREAKER EP 11.1
Просмотров 50 тыс.2 года назад
Sa video na ito, paguusapan naten kung pasado nga ba sa Philippine Electrical Code ang talamak na paggamit ng 2 pole breaker sa line to ground o line to neutral systems para pag hiwalayin ang circuito ng ilaw at outlets! Malalaman din dito kung ano nga ba ang tamang gagawin at mga rekomendasyon at iba't ibang klase ng mga breakers na pwedeng gamitin para makatipid at the same time in line sa at...
LINE TO GROUND TWO 2 POLE BREAKER RCBO RCCB GFCI NEUTRAL AT GROUND BONDING TAMANG CONNECTION EP 11
Просмотров 34 тыс.2 года назад
Sa video na ito, pag uusapan naten paano nga ba iimplement ang tamang paggamit ng 2 pole breaker sa single phase 2 wire line to ground o line to neutral system. Tatalakayin din saan at paano ang tamang bonding ng grounded conductor (neutral) at equipment grounding conductor pag may 2 pole na breaker lalo na ang mga RCBO, RCCB o GFCI. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST ...
LINE TO GROUND O LINE TO NEUTRAL CONNECTION METER CENTER GUTTER BOX GROUNDING SERVICE ENTRANCE EP 10
Просмотров 33 тыс.2 года назад
Sa video na ito, tatalakayin naten ang tungkol sa meter center na line to ground o line to neutral single phase 2 wire system. Full connection lahat ayon sa PEC at sa common practices. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
MERALCO SERVICE ENTRANCE HIGH RISE BUILDING ELECTRICAL MULTI METERING PER FLOOR METER CENTER EP 6.1
Просмотров 8 тыс.2 года назад
Isang mabilisang quick trial video lang ng ating multi metering per floor sa isang high rise building simula sa riser pole ni meralco papunta sa transformer vault tapos sa busduct riser hanggang sa makarating sa meter center per floor. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
LINE TO LINE METER BASE METER CENTER AYON SA PEC PAANO? SERVICE ENTRANCE GUTTER BOX GROUNDING
Просмотров 11 тыс.2 года назад
Sa video na to pag uusapan ang tungkol sa Line to Line Meter Center Multi Metering connection and wiring diagrams ayon sa Philippine Electrical Code (PEC) at NEC. Hango din rito ang mga best practices at common meter center standards ng mga DU like Meralco. PRACTICAL PHILIPPINE ELECTRICAL WEBINAR SERIES FULL PLAYLIST 🔗 ruclips.net/p/PLO4MWmSMQe6Z56GgD5IkGBzHMvW0u_Tqe
LINE TO NEUTRAL AT GROUND - MULTI GROUNDED NEUTRAL SA DISTRIBUTION SYSTEM TRANSFORMER GROUNDING EP 8
Просмотров 18 тыс.3 года назад
Dito sa video na ito ay tatalakayin kung ano nga ba ang tunay na "multigrounded neutral" na ginagamit ng mga distribution utilities at rural coops sa Medium Voltage distribution systems sa bansa nateng Pilipinas. Parehas nga ba ito sa sinasabi nilang line to neutral at line to ground dito? At literal na ginawang ground ang neutral wire sa medium voltage??? PRACTICAL PHILIPPINE ELECTRICAL WEBINA...
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE - PAANO ANG TAMANG WIRING NG METER BASE METRO - EP. 7
Просмотров 75 тыс.3 года назад
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE - PAANO ANG TAMANG WIRING NG METER BASE METRO - EP. 7
METER BASE SA METER CENTER SERVICE ENTRANCE PEC BUSBAR CB GUTTER BOX MULTI METERING - EP. 6 MERALCO
Просмотров 76 тыс.3 года назад
METER BASE SA METER CENTER SERVICE ENTRANCE PEC BUSBAR CB GUTTER BOX MULTI METERING - EP. 6 MERALCO
LINE TO LINE CONNECTION SINGLE PHASE AYON SA PEC (MERALCO VECO SUPPLY) 110V PWEDE EP. 5
Просмотров 70 тыс.3 года назад
LINE TO LINE CONNECTION SINGLE PHASE AYON SA PEC (MERALCO VECO SUPPLY) 110V PWEDE EP. 5
LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING
Просмотров 270 тыс.3 года назад
LINE TO GROUND O LINE TO NEUTRAL SINGLE PHASE TAMANG CONNECTION PEC (PINOY TAGALOG) EP. 4 GROUNDING
GROUND WIRE SA SERVICE ENTRANCE AY KULAY WHITE O GREEN GROUNDING - EP. 3
Просмотров 43 тыс.3 года назад
GROUND WIRE SA SERVICE ENTRANCE AY KULAY WHITE O GREEN GROUNDING - EP. 3
NEUTRAL VS GROUND AYON SA PEC - TAMANG TERMINO (TAGALOG) - EP. 2
Просмотров 56 тыс.3 года назад
NEUTRAL VS GROUND AYON SA PEC - TAMANG TERMINO (TAGALOG) - EP. 2
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE SINGLE PHASE HISTORY AT PAGKAKAIBA BASE SA PEC - EP. 1
Просмотров 215 тыс.3 года назад
LINE TO GROUND LINE TO NEUTRAL LINE TO LINE SINGLE PHASE HISTORY AT PAGKAKAIBA BASE SA PEC - EP. 1
Q&A: What happened here? (PVC Conduit Thermal Expansion)
Просмотров 1,7 тыс.3 года назад
Q&A: What happened here? (PVC Conduit Thermal Expansion)
Q&A: Transformer primary and secondary color coding required?
Просмотров 1,4 тыс.3 года назад
Q&A: Transformer primary and secondary color coding required?
Q&A: Why do we have 6 primary terminals on a pad mounted transformer?
Просмотров 3,6 тыс.3 года назад
Q&A: Why do we have 6 primary terminals on a pad mounted transformer?
Q&A: Is it required to disconnect the neutral or grounded conductor?
Просмотров 1,1 тыс.3 года назад
Q&A: Is it required to disconnect the neutral or grounded conductor?
Q&A: Is it okay to have 10 AWG wire for a 50A breaker for aircon units?
Просмотров 2,1 тыс.3 года назад
Q&A: Is it okay to have 10 AWG wire for a 50A breaker for aircon units?
ERICCSON CONSTRUCTION REACTION VIDEO
Просмотров 1943 года назад
ERICCSON CONSTRUCTION REACTION VIDEO
Q&A: Grounding electrode conductor ferrous metallic raceway bonding
Просмотров 8743 года назад
Q&A: Grounding electrode conductor ferrous metallic raceway bonding
Is it permitted to run equipment grounding conductors (EGC) outside raceways or cable assembly?
Просмотров 3 тыс.3 года назад
Is it permitted to run equipment grounding conductors (EGC) outside raceways or cable assembly?
What is the maximum busway / busduct support spacings?
Просмотров 1,2 тыс.3 года назад
What is the maximum busway / busduct support spacings?
Why do we need drip loops for service entrance?
Просмотров 1,4 тыс.3 года назад
Why do we need drip loops for service entrance?
Risers Guarding and Protection near Ground
Просмотров 1,2 тыс.3 года назад
Risers Guarding and Protection near Ground

Комментарии

  • @kellvivar
    @kellvivar 22 часа назад

    dapat binibili ng gobyerno nyen yun mga ganitong content pra ituro sa students para kahit basic knowledge meron ang kabataan.

  • @09kalix
    @09kalix 4 дня назад

    the neutral conductor is another term po is return?

  • @rojandeopita9465
    @rojandeopita9465 4 дня назад

    master anu kaya dahilan bakit nung kumidlat amin lng electricfan na sira. tapos C.O na wla nmn load na sira. pero ung C.O na wlang load un lg kabila. almost 16feet mula sa wall breaker ang distance ng C.O ung wire pina daan ko sa kalsada. pero may PCV nmn. nagkataon lng kaya na amin ang bahay ang pinag daluyan 2 wire po line to Ground. o maykinalaman ung wire na pinadaan ko sa kalsada.

  • @rojandeopita9465
    @rojandeopita9465 4 дня назад

    malinaw talaga master salamat

  • @AskTig4609
    @AskTig4609 5 дней назад

    Mataas impedance ng ground? Tig coconsider po na 1 to 0 ohms ang ground/earth. Kaya nga tayo may grounding system para sa fault current, since easier path sya to travel, sa earth na lng mapupunta yung fault current Atska, dun po sa sinabi mo na safe pag hinawakan yung wire since wala namang potential difference. Meron po! From your hand to ground, meron pong potential difference, meron pong current na dadaan. But since may pathway rin na deritso sa ground, most of the current ay derikta sa ground. Kaya yung nararamdaman natin ay shock lng

  • @basicsteps
    @basicsteps 10 дней назад

    Question po. Meron kaming electric oven na gusto pa naming gamitin sa lilipatan namin. Pinapalagyan ko po ng grounding lahat ng outlet sa kusina. Kung ang oven ay grounded sa metal chassis, ibig sabihin non ay magtitrip ang breaker? Sa existing na tinutuluyan namin ay hinde, pero ingat kami sa paghawak sa oven. Kasi kung ganun pala, dapat bawat outlet sa kusina ay dapat may sariling breaker para di lahat madamay dahil lang sa isang appliance.

  • @jasminpadernal2704
    @jasminpadernal2704 17 дней назад

    Nice knowing sir. It means, there's no way we can use 3 wire systems like drier from u.s into 2 wire systems in urban areas?

  • @glennlopez1124
    @glennlopez1124 18 дней назад

    how to make 120V receptacle in the philippines

  • @glennlopez1124
    @glennlopez1124 21 день назад

    makakagawa ba ako ng 120V, using L1 and that bare cable from the post?

  • @EdgarStaAna
    @EdgarStaAna 22 дня назад

    Contact number po ng electrician pililla rizal area.

  • @EdgarStaAna
    @EdgarStaAna 22 дня назад

    Good afternoon. May contact rizal area pakabit ako service entrance .

  • @user-xu7op4rd2s
    @user-xu7op4rd2s 25 дней назад

    Sir kung single pole with neutral pwedeng ung bonding ay after circuit breaker

  • @justinemarcos
    @justinemarcos 26 дней назад

    nice 👍🏿

  • @w6pxt
    @w6pxt 27 дней назад

    Dito sa U.S. ang mga clothes dryer karamihan ay 220 V. Ganon din ang air conditioning system, ang mga condensing unit kung nasaan ang compressor at outdoor fan ay 220 V. din. That is the reason na mayrong neutral wire dito dahil ang mga appliances at ilaw ay puro 110 V. Kaya nga ang mga circuit breaker panel dito ay design sa 220 and 110 volts capable sila sa 220 and 110 volts.

  • @w6pxt
    @w6pxt 27 дней назад

    Does it mean na ang live wire mo sa 2 wire system ay 440 volts. Kasi pag nag test ka ng live wire to neutral ay 240 volts, tama ba?

  • @reymarkembate3411
    @reymarkembate3411 Месяц назад

    thanks pre!

  • @JesicaVitor
    @JesicaVitor Месяц назад

    Boss how to order

  • @freddieleeancheta352
    @freddieleeancheta352 Месяц назад

    salamat sa mga vedios mo sir. sir may lang po ako sana po masagot hanggang ngayun kc nalilito pa ako. pag sinabi po bang line to ground yung line po ba natin ay 230 volts na? , at yung grounding conductor natin ay zero volts?

  • @EliezerOllieDrio
    @EliezerOllieDrio Месяц назад

    Pero lods ang line to neutral na ano line to ground system 110volts lang bayan dahil isang live wire lang ang pomasok hindi yung dalawa talaga kaya 110volts lang yan

  • @manuellastrollo2168
    @manuellastrollo2168 Месяц назад

    sir why here your not using PEC as your reference?

  • @manuellastrollo2168
    @manuellastrollo2168 Месяц назад

    sir sa submeter ng line to neutral hindi na ba iba-bond sa meter base?

  • @user-xu7op4rd2s
    @user-xu7op4rd2s Месяц назад

    Gd eve sir ..wala akong nakuhang rcbo na single pole plus neutral na 100 a ...pwede n gamitin ung double pole...pero line to ground ung supply ....singke lafat sa load side ko

  • @abelmacamu2270
    @abelmacamu2270 Месяц назад

    Dito samin walng grounding😅😅

  • @kamtv1455
    @kamtv1455 Месяц назад

    Pasagot naman po sabi ng Electrician para makatipid daw kami sa kuryente magbabaon siya ng ground steel tapos doon na raw ikakabit ang isang linya at isang linya naman galing sa Meralco yung Neutral daw? Tama po ba ito o pinagloloko lang kmi, umiilaw naman na? Pero sa pagkakaintindi ko sa video niyo po ay bawal ito at pwede kami makuryente? Help nman po, kakakabit lng po.

  • @rogernbackyard6677
    @rogernbackyard6677 Месяц назад

    Thank you sir sa pag share,,nakatulong po kayo,,galing ng pagkapaliwanag

  • @cedrhickleonard313
    @cedrhickleonard313 Месяц назад

    Ay Oki na po gets na 😅😅

  • @jeunjeuntolentino9081
    @jeunjeuntolentino9081 Месяц назад

    mas marami pa akong natutunan dito kaysa noong nag aaral pa ako. Instructor nmin panay yabang at pananakot lang alam. Salamat po.

  • @manuellastrollo2168
    @manuellastrollo2168 Месяц назад

    ilang jaw?

  • @dheomoreno4013
    @dheomoreno4013 2 месяца назад

    Newbie ako gusto ko matuto nuod ako youtube dmi nd nag lalgay ng grounding.pero ito safety first....

  • @AgapitoDizonjr
    @AgapitoDizonjr 2 месяца назад

    Pwed maging kanya kanya kung ang metro m ay nalipat n sa poste

  • @drichio901
    @drichio901 2 месяца назад

    Very Informative ! andami ko natutunan. Salamat !

  • @simplethings2410
    @simplethings2410 2 месяца назад

    papaano po kung line to line po ang service..kailangan pa po ba i.ground ang load end ng service conductor?

  • @jamesortega8681
    @jamesortega8681 2 месяца назад

    noob question, so yun green wire aabot sya hanggang sa outlet, eh pano pag appliance mo eh 2 prong lang ang electrical plug nya, karamihan yta ng appliance ganun, does it mean useless yun green at hindi sya makaka connect sa appliance nayun halimbawa electric fan,

    • @unwired
      @unwired Месяц назад

      Pag 2 prong lang, ang Neutral na ang Ground mo. Since bonded sila sa source. Ref: 19:30 My mga devices or appliances na dapat naka extra earth for safety like mga metal body - ref, microwave, washing machine and EV chargers.

  • @user-xu7op4rd2s
    @user-xu7op4rd2s 2 месяца назад

    Sir.....dito sa amin line to ground....sa panel board ko neutral at grounding bonding.....14 circuit siya .....gusto kung two pole ung main breaker ko pero sa acu ko three wire ang nilagay ko ...gusto one pole ung c/o one pole ung l/o one pole ung ref..pero two pole ung acu at electric motor ...reason kc kulang ung panel board kc 18 line lang pag nagdoubke pole aq sa mga linya ko kukulangin kc bali 15 ckt aq ...pwede ba icombine ko ung one pole at double breaker sa distribution

  • @sherwincastillano1695
    @sherwincastillano1695 2 месяца назад

    Boss pwede ba mag PM sau meron lng sana ko tatanung baka makatulong po

  • @ramondecastro4715
    @ramondecastro4715 2 месяца назад

    Insulation resistance testing Naman topic mo thanks

  • @user-xu7op4rd2s
    @user-xu7op4rd2s 2 месяца назад

    Sir...line to ground sa amin ....pwede ba two pole ung main tapos ung branches two at one pole combination ...pero paanu magkabit ...3wire ung acu ko

  • @fredericktayao4252
    @fredericktayao4252 2 месяца назад

    Master panonpag walang service equipment pwede ba yun, sa panel boare nalang po ba ang bonding jumper nun? TIA

  • @JojoCruzSolano
    @JojoCruzSolano 2 месяца назад

    sir sa ngayon 2 wire na lang naka drop pa puntang bahay na ginawa ng meralco kasi na sa taas na ang mga kuntador sa poste kaya naka lagay 2 wire na naka tap sa bahay. kailngan ko pa ba mag baon ng ground Rod para sa mga apliances. kasi 2 wires lang binigay ng meralco

  • @JojoCruzSolano
    @JojoCruzSolano 2 месяца назад

    minsan kasi sir pag bibili ka sa hard ware ng white wire sabhin wala greean lang available kaya yun na ilalagay ng iba na electrician kasi same din naman daw ang number ng wire sa breaker

  • @JojoCruzSolano
    @JojoCruzSolano 2 месяца назад

    ibig sabhin sir kahit isa pinggalingan niyan neutral o ground gagawa ka pa din o mag babaon ka parin ng sariling mong ground rod kahit alam naman natin iisa lang yan pinggalingan ng ground na neutral na sinasabi

  • @ERNTify
    @ERNTify 2 месяца назад

    Napaka detalyado ang paliwanag...sugest ko lang sir, na gamitin mo ang ibang term sa sinasabi mong voltage drop para hindi malilito ang mga batang electrical practitioners kung ano ang VD

  • @barriotek
    @barriotek 3 месяца назад

    Galing NEA or COOP guro si master

  • @kurtsalgados2815
    @kurtsalgados2815 3 месяца назад

    1:05 Legit yung aklat na yan😊 dami kong natutunan mula pa nung nag aaral ako ng E.I.M...😊😊😊😊

  • @opecons
    @opecons 3 месяца назад

    18:56 engr in terms of PEC/NEC matatawag ba Ground ang linya na yan. Ano ang Ground in terms of PEC?

  • @opecons
    @opecons 3 месяца назад

    18:14 .kun ayaw mong tawaging neutral, ano ang definition ng Ground?

  • @opecons
    @opecons 3 месяца назад

    14:10 eh saan din nanggaling ang terminong Line to Ground?

  • @opecons
    @opecons 3 месяца назад

    18:32 bakit tinawag ground ang isang linya sa 2-wire, kun line to ground ang tawag dapat doon ka magconnect sa lupa. Ano ba definition ng Ground?

  • @opecons
    @opecons 3 месяца назад

    13:47 komo ba nakakabit sa ground tawagin mo na ground. Paano naging ground o lupa ang magnetic conductor.

  • @opecons
    @opecons 3 месяца назад

    5:54 kun tawagin nating grounded conductor dapat tawagin din nating ungrounded ang kabilang linya kaya magiging ungrounded conductor to grounded conductor. Pero engr bakit tinawag mong Line to Ground? Ang isang linya ng winding sa transformer ay tinawag mong Line at kabilang linya ng winding sa transformer ay tinawag ground. Tanong ano ba ground? Paano nagiging ground ang winding ng transformer? Paano naging lupa ang isang linya ng transformer? Asa po sa PEC na ang single phase 2-wire system na tinawag na Line to Ground system?