Installation of 7 socket meter base 3 phase line to neutral 380 to 400V | Pinoy Electrical Warrior

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • Video title: Installation of 7 socket meter base 3 phase line to nutral 380 to 400V
    WELCOME TO MY CHANNEL
    PLEASE LIKE, SHARE & SUBSCRIBE PINOY ELECTRICAL WARRIOR
    and also Please Like & Follow our FB page:
    / pinoyelectricalwarrior
    SUBSCRIBE to Kuya Dudz Official Channel
    / @kuyadudzofficial8817
    SUBSCRIBE to Kuya Arman Official Channel
    / @kuyaarmanofficial
    THANK YOU!

Комментарии • 114

  • @danilogo235
    @danilogo235 2 дня назад

    Ayos idol, na aalala q ng kabataan q pa. Ang sarap mag terminate, kapag busy ka sa trabaho. Ingat Po lagi sa work sir. Nag retired na po aq sir. God Bless Po sa buong team ninyo.

  • @carlosortillo9478
    @carlosortillo9478 6 месяцев назад +1

    salamat bossing anggaling mo may natutonan Ako God bless you ma Buhay ka

  • @IldefonsoOnida
    @IldefonsoOnida Месяц назад +1

    Ayos idol sana all ingat palagi mga idol

  • @jordanoliveros3510
    @jordanoliveros3510 Год назад

    Maramimg salamat boss marami Ako na tutunan sa vlog mo God bless you

  • @ejaybeltran5242
    @ejaybeltran5242 7 месяцев назад

    Kakamiss din ung ganyang trabaho sa building

  • @ElectricalPinoyTutorialTV
    @ElectricalPinoyTutorialTV 2 года назад +2

    Shout out mga ka master pasama sa proj. 💜

  • @gerwinsiago9370
    @gerwinsiago9370 2 года назад

    Good job..always wear a gloves for safety

  • @pinklawans8169
    @pinklawans8169 2 года назад

    Ayus Yan mga Sir.. 👍👍👍🙏

  • @armandogulle2602
    @armandogulle2602 Год назад

    Mga brod.mag gloves kayo for safety at lagyan nyo nang terminal lugs bago ikabit sa terminal

  • @jaynelson08
    @jaynelson08 Год назад

    Danas ko nayan ganyan master, TEAM highvolt, gawa namin Braches ni Robinsons easymart. Hanggang genset wiring at layout

  • @simpliciocamirino2271
    @simpliciocamirino2271 2 года назад

    thank you for that sharing sir.

  • @renzofficial2435
    @renzofficial2435 2 года назад

    nice tutorial master sir

  • @ganiebasalo7367
    @ganiebasalo7367 Год назад

    Buhis buhay po talaga kapag electrician, isang pagkakamali mo jan ,godbye

  • @joedelaluna8256
    @joedelaluna8256 3 месяца назад

    Pagdating po sa kinabit mo na metro.220v n yan sir

  • @reymondrono982
    @reymondrono982 Год назад

    Nextvlog master Megger test namN

  • @linbertsaturinas2014
    @linbertsaturinas2014 2 года назад +2

    Sir. Baka pwede po gawa kayo ng schematic diagrams nyan para lubos namin ma unawaan. Bago Lang Sir

  • @dallantvbuilders8380
    @dallantvbuilders8380 2 года назад

    Husay Mo Talaga Kamasta

  • @markanthonynilo9198
    @markanthonynilo9198 2 месяца назад

    Sir ano pong size ng Allen Wrench na kailangan? Salamat Po.

  • @armandogulle2602
    @armandogulle2602 Год назад

    Kabitan nyo nang lugs at gumamit kayo nanh crimper/crimping tool

  • @Ato-kf4ld
    @Ato-kf4ld 2 месяца назад

    Sir yung nasa gitna nang meter base yon ba yung groud?

  • @reymondrono982
    @reymondrono982 Год назад

    Solid

  • @jeffreypadernilla4485
    @jeffreypadernilla4485 2 года назад +1

    Ask lang master,pag d naka terminate ground d ba gagana master?

  • @olivertinambacan1024
    @olivertinambacan1024 5 месяцев назад

    pwede puspusin ng dos for dos yan master baka mabuak yan

  • @JohnlyLiquido-lj9yj
    @JohnlyLiquido-lj9yj 2 месяца назад

    ganyan din ba termination sa meralco base meter

  • @user-mo2uj8qk9b
    @user-mo2uj8qk9b 6 месяцев назад

    Taga saan po kayo sir tanong lang po

  • @leenahibuan9304
    @leenahibuan9304 Год назад

    sir anu yan allen wrench tpos plier😅 always use the right tools on the right job. and live yan lods ikw na nag sabi delikado dpt nka rubber gloves kau jan bago mag kalikot sa loob kht maingat pa kau dpt mag ppe parin kau lalo na blog yan baka gayahin ng iba

  • @masterjotv8757
    @masterjotv8757 Год назад

    brod.. formula ng line to neutral Ln= Ll Voltage over sq root of 3, Ln= 400v Divide 1.732=230 volts wye configuration

  • @nhessardiente8048
    @nhessardiente8048 2 года назад

    Sir good job,baka pwede kayo mag vlog Ng ,pero gamit cya Ng step down transformer,pwede Po ba

  • @juntechblogs2642
    @juntechblogs2642 Год назад

    how to read it right that meter ? kasi nagbi blink nag-iibaiba ang numbers alin ba dun ang tamang reading ng kwhr used? pls ans.

  • @user-bu2cg3cx5k
    @user-bu2cg3cx5k Год назад

    Sir ano dapat gamitin meter base 220v 3phase 5pin ba o 7pin salamat

  • @LimTv
    @LimTv 5 месяцев назад

    3 phase 3 wire 200V / 400V close bank kaya pang dilaan yan

  • @philippeandres7158
    @philippeandres7158 2 года назад

    sir mag upload din ppo kayo nang meter na single phase ung may demand meter form 4s, at ung 3 phase na may demand meter na direkta sa meralco hindi submeter

  • @user-mo2uj8qk9b
    @user-mo2uj8qk9b 6 месяцев назад

    Mag kano po labor ng pag kakabit ng submeter at meter base tanong ko lang po

  • @Alikabokkalang3408
    @Alikabokkalang3408 2 года назад +1

    👍👍👍

  • @rogeliorozul5036
    @rogeliorozul5036 Год назад

    master tanong lang po.... yan po bang ikinabit nyo na metro na yan may MULTIPLIER po ba yan master?

  • @efrencadag8258
    @efrencadag8258 11 месяцев назад

    Mas ok po ba sir kong neutral ang ilagay?

  • @carlitopatero4906
    @carlitopatero4906 2 года назад

    magandang umaga sir, sa 12 palapag na may 2 floor na parking lot at at 2 floor na para grocery store mga ilang ampere po ang main breaker na magagamit kasama na load ng elevator? salamat po

  • @aldwinpalado7376
    @aldwinpalado7376 2 года назад

    Gamitin nio sir nan terminal lugs saka shrinkable

  • @reymondrono982
    @reymondrono982 Год назад

    Idol ma tanung Kung SA 350amps na main breaker ilang amps ang maximum current ang kaya

  • @garryesguerra8032
    @garryesguerra8032 2 года назад

    Mas safe lods page fiberglass na ladder gamit nyo KC live termination na yn

  • @paanovlog3296
    @paanovlog3296 Год назад

    Sir pasagot naman po ano ba dpat ilalagay na circuit breaker size dito sa 4 sets 250mm² (L+N)& 30mm² ground..nsa questionare kasi ito ng entrance exam ano kya po ang sagot dyn?

  • @mdmubarokchan2218
    @mdmubarokchan2218 8 месяцев назад

    M

  • @josenisay4886
    @josenisay4886 9 месяцев назад

    Idol, medyo nalito ako sa color coding ng cable , Meron ba standard na color ? black , red, blue, brown , orange, yellow,

    • @papaghiewetanddryadventure6249
      @papaghiewetanddryadventure6249 8 месяцев назад

      R Y B sir ang standard n color coding Red Yellow Blue or Block,ang neutral always dpat color White

  • @philipsabado1986
    @philipsabado1986 2 года назад +2

    Boss Wala bang diagram yan

  • @ydu5
    @ydu5 Год назад

    Sir kv2c aclara 16s 3pahse hindi ba gagana kung walang neutral

  • @nilobarbecho758
    @nilobarbecho758 2 месяца назад

    Nasan ang nuetral wire sa metro?

  • @reymondrono982
    @reymondrono982 Год назад

    Kung mag upgrade Kami Ng 600amps na breaker ilang mm na wire ang need

  • @alvinrecta7449
    @alvinrecta7449 2 года назад

    Sir pag po ba sa main line galing transformer c meralco na po ba ang nagkakabit ng meter nyan.. Salamat po

    • @PinoyElectricalWarrior
      @PinoyElectricalWarrior  2 года назад

      Bale electrician po ang kakabit ng meter base, yong kay meralco ay power supply

  • @glenmarksuaverdez4499
    @glenmarksuaverdez4499 2 года назад

    master dipo ba problema kung marami ang saksakan tapos ai 30 amp po ang fuse na gamit?

  • @edmundyaon6905
    @edmundyaon6905 2 года назад

    Sir ang ibig sabihin po ba?
    Ng 3 phase tatlo yung cable
    Na susuplayan ng kuryente
    Yung pang apat naman eh
    Sa ground naman po oh
    Neutral

  • @christianlegaspi1653
    @christianlegaspi1653 Год назад

    Boss yung neutral po ba dumaan din ba sa meter base or hindi

  • @edgardosantos9912
    @edgardosantos9912 2 года назад

    sir, anong size po ang equivalent ng 183m . d ko po makita sa chart , mag upgrade po kc ako nang service entrance. parang kasing laki po ng ginmit ninyo sa video ngayon

  • @annarizzuanahernandez3917
    @annarizzuanahernandez3917 Год назад

    Master kasya po jan ung 150mm2

  • @willbertestoya1539
    @willbertestoya1539 2 года назад

    sir yung ganyang klase ng 7 jaw submitter ba eh kaya ba yung 460 volts

  • @glenncruzbabaan
    @glenncruzbabaan Год назад

    Sir pag 1200A ang Main CB mo (Aerial tyoe), ano ang cable size na gagamitin papunta sa load side?

  • @jsexhaustec9966
    @jsexhaustec9966 Год назад

    Sir paano po mag tap sa 3 phase electric meter e single phase lng po supply nila??

  • @jjheart8621
    @jjheart8621 2 года назад

    Sir ask lang po, nagkabit po ako ngayon ng 7 jaws na meter ngayon po wala pong display yung monitor ng meter ano po kaya ang problema?

    • @PinoyElectricalWarrior
      @PinoyElectricalWarrior  2 года назад

      Pasensya na sir late reply sobrang bc, yong 7 jaws sir pang line to neutral, kong line to neutral po line niyo dapat gagana yan kailangan lang yong grounding wire naka terminate din

  • @ericmixvlog8728
    @ericmixvlog8728 Год назад

    Sir paano ba mgwiring sa CT donut papuntang meter base na 3 phase?

  • @glenmarksuaverdez4499
    @glenmarksuaverdez4499 2 года назад

    saka kung ari pong gumamit ng no.12 na stranded wire sa 30 amp for outlet po?

  • @andrewnortez7530
    @andrewnortez7530 2 года назад

    sir anu po kaya problema ng meter 7jaws po kapag niloload kasi ang ACCU nawawala ang display, pero pag ilaw at outlet meron lang

  • @albertomalabanan6015
    @albertomalabanan6015 2 года назад

    Ac din Po ba yang red yellow blue?

  • @rozkiezamora4026
    @rozkiezamora4026 Год назад

    Nasaan po yung neutral ng metro

    • @PinoyElectricalWarrior
      @PinoyElectricalWarrior  Год назад

      di namin nilagyan para sa
      neutral yong grounding lang nilagay namin pwede naman ang grounding kahit walang neutral

  • @eiodoggo7963
    @eiodoggo7963 Год назад

    Pwd ba ako.aply sa inyo electrician po ako

  • @benjaminfulleros2374
    @benjaminfulleros2374 Год назад

    Unsafe yung mga kamay niyo mag suot naman po tayo ng guantes,lalo na electrical work.

  • @jayarmortera5114
    @jayarmortera5114 Год назад

    Sir ,patulong po sana .. yung nabili po kasi na meter base is for 120-480v ..ngayon nag install po ako pero yung power supply lang po namin ay 3phase na 220v.. may kuryente naman po sa load side pero bakit po kaya walang reading yung metro?? kahit isa walang nakalagay 😟 black out lang siya kahit meron na po gumagamit ng kuryente..help naman po sir ..thankyou and Godbless po sa inyo..

    • @PinoyElectricalWarrior
      @PinoyElectricalWarrior  Год назад

      d po pede yan...papalitan m k m kc hindi compatible yan..kaialangan my nuetral

    • @jayarmortera5114
      @jayarmortera5114 Год назад

      @@PinoyElectricalWarrior anu po ipapalit na meter base Sir? yung linya po kasi na lumabas sa panel wala pong neutral Sir ..3phase 220 lang po sir ..paano po ba dapat

  • @pitz10
    @pitz10 3 месяца назад

    kung totoong magaling ang nag install diyan. bakit walang mga label bwat breaker malapit diyan sa panel?hahah joke lang

  • @ricjaysonrafael1294
    @ricjaysonrafael1294 2 года назад

    master paano pag hndi line to neutral ang supply pero 7jaw naikabit

  • @wilsonmagalonajr7058
    @wilsonmagalonajr7058 Год назад

    master bakit di ipinasok yung neutral sa meter socket?