PANO KUMUHA NG SINGLE PHASE LINE TO NEUTRAL OR LINE TO LINE ON A 3PHASE POWER Basic Electrical #22
HTML-код
- Опубликовано: 9 фев 2021
- In this video, i will show you all Lods, How to get Single-phase line to neutral and Line to Line on a 3Phase Power Source.
NOTE: Not all 3Phase Power source Voltage rating are the same, mag babase yan sa need ng consumer as pag gagamitan ng load,
CAUTION!!! Wag basta basta gayahin ang mga nasa drawing, If need mo ng supply para sa load mo ng line to line or line to neutral, Much better check it with Multimeter first.to make it sure.
DISCLAIMER!!! I am not a professional, but I can contribute my gathered knowledge, Experience and skills in this video
If you have any questions, feel free to comment down below.
PA LIKE COMMENT & SHARE NALANG MGA LODS, SALAMAT
CHANNEL MEMBERSHIP / @galawangelectrical
#3Phase
#SinglePhase
Lodi excellent ang blog mo madali kami matututo mabilis na malinaw pa kaya hindi boring....
thanks a lot lods, sarap pakinggan lodi. happy to help here. dami pa tayo mga video jan.
Very informative ito lalo na sa mga kalalakihan. Check talga yng power source.
thank you so much
Salamat sa mga tutorial mo lodi
marami ako natutunan dito
Keep sharing lodi
Safety first
your welcome lods, any time!
Salamat sa mga kaalaman na ito.
your welcome, stay connected!
Very clear explanation sir thank you! More power to you God bless!
Glad it was helpful! your welcome lods! dami pa tayong mga videos jan.pa like ang comment nalang lods, laking tulong yan sa mga videos ko. thanks.
Thanks bro, im learning so many things from you!
Glad to hear that, thanks lods.
Boss dagdag lang po, both 1phase at 3ph ,base sa PEC ang kulay ng neutral or grounded conductor ay white, hindi po black ang neutral wire sa atin. Ang PEC ay nakapattern sa NEC at mayron din inaadapt galing sa IEC.
yes tama ka lodi, mostly is naka addapt tayo sa american standard. kaya white ang ginagamit, pero for some reasongis bakit yung iba dito sa pinas is makikita mo minsan is hindi white. in awareness nalang is dapat alam din natin ang ibang standard code ng ibang country, especially kung napupunta ka ng ibang bansa. so atleast is ma visualize natin na neutral yun. atleast may idea tayo. thanks sa comment lods.
Ibig sabihin nyan lodi, yung iba hindi nila nasunod ang provision sa PEC na kilangan white ang kulay ng nuetral conductor. Pero kun malaki na wire , puro black ang insulation ng wire sa 3 phase kilangan may tagging or tape ang bawat phase at white tape ang para sa nuetral para maidentify na ito ay nuetral conductor. Kasi ang concern natin pagdating sa wiring installation sa atin ay base sa PEC at standard po ng PEC ang masusunod. #PEC 2.0.1.6
Tama ka jan master ang tamang electrical practationer nka base tayo patakaran ng pilipinas which is ang PEC hindi tayo doon ibang bansa mag base kasi iba rin ang kanila,, kung ano ang ating batas yon ang sundin natin ,,kasi bat natin i apply ang ibang bansa ehh sa kanila yon,,,ang sa atin ay kung anong nka saad sa PEC kung neutral natin ay white,,,white tlaga kasi yon ang nka saad sa batas natin sa electrical. Or kung tipid ka man sa wire lagyan mo ng vinyl wire end cap ang wire mo para alam ng mg troubleshoot kung saan ang hot wire or kung saan ang neutral wire
@@SeigfredWall tama ka sir , PEC ang Basihan hindi sa ibang bansa. Kun naadapt ang Red-Yellow-Blue para sa hot wire galing sa old UK color code , neutral nila ay black. Pero sa atin ang neutral ay white. Ito ay hango sa NEC. At sa color color ng US ay Black-Red-Blue (hot wire) neutral ay white.
nice content Idol very informative panu kumuha ng single Phase Line to Neutral
thank you so mucg lods, thank for watching!
Thanks for great informative video kapatid, more to come and enjoy
your welcome and thank you too!
Thank you for always supporting. Nandito ako to support you also kahit na di ko maintindihan hehehe. Ingat lagi.
your welcome lods, thank you too for dropping by!
Super galing kabayan,,nice tutorial
thank you so much lods,
very interesting and so useful thanks for the words
Glad it was helpful! thanks for watching!
Very nice sharing my friend have a great day
Thank you! You too! thanks for watching!
Another informative video about wiring
Glad you liked it, thank you so much for watching!
Okie kaayo engener I love it!!!!!!
thanks you so much lodi
Good job my friend you did a great job.
Thanks for the visit, thanks for the comment.
Thank you for sharing kabayan , good to know about it..
My pleasure 😊thanks you for watching!
Goo to know to this mahal dito ang electrician sa US.
knowing the basic and mag ka idea, is a step. thanks for watching.
Omgggg this video is indeed informative po thank you for sharing this I learned a lot po I will share my channel to my friends po who wants to learn about electrical stuffs po new here full support sent po😍🤗
Glad it was helpful! thank you so much for watcing!
Awesome vedio nice sharing
Thank you so much 🙂 have a great day!
Great work on todays video my friend :)
I wish you a blessed day
Thank you! You too!
Good sharing👍👍👍
Thanks for liking
3 phase power source tutorials thank you.
More to come! thanks for watching!
very helpful and informative video
watching here
stay safe
Thanks, you too!
Hanep lods isang napakagandang pagbahagi salamat
yes, thank you so much lods sa pag dalaw.
Very helpful ang video mo lods
yes lods, happy to help others sa mga like ng ganitong content. and thanks din sa mga long time friend dito sa yt. thanks a lot.
Salamat sa tutorial mate good morning from UK cheers...
walang anuman paps, thanks for dropping by!
GOOD TO KNOW BROTHER THANKS FOR SHARING
Any time thanks for dropping by!
Liked, fantastic video Bro we always enjoy learning with u u know everything and have loads of amazing tips we love watching keep the wonderful content coming we r always here watching thanks for sharing, please stay in touch and Take Care Bro!
thank you so much for the support lods,
Very informative
Glad it was helpful! thanks for watching!
Good one! keep going👍
thank you so much for watching lods!
Nice vedio idol may idea nako, idol yung sumbrero mo gosto ko
thanks lodi, dami pa tayong mga videos jan lods, tanong ka lang baka may gusto ka malaman about jan sa 3phase to single phase. yung cap, luma na yan sa ngayon hahaha. nabawi nadin yan sa mga project na dumaan hehe.
First tamsak po
thank you so much for watching!
Salamat po lods
walang anuman lods, madami pa tayong mga videos jan lodi.
Nice share lods.
Thanks for visiting stay connected!
hello new friend here from Bali watching you pamo kumuha bla bla bla hehe thanks for sharing see u
thank you so much, keep in touch lods.
Thank you idol.❤
your welcome lods, madami pa tayong mga videos jan. feel free to comment lods, at sasagutin natin yan.
thanks for the tutorial brother
My pleasure thank you too!
Nice work idol.
thank you so much lods!
This is such a good tutorial kapatid ,,,Alam moba dito sa UK kapatid ang mahal mag bayad ng electrician.
yes sabi nga ma'am Jove. thank you for watching.
Done thumbs up stay safe stay connected see you
thanks, keep connected lods,
Parang madali lang pero parang d ko matandaan hahhaha happy weekend po
it okay lang, hehe. thanks for watching!
Good luck
thank you so much! thanks for watching!
Here kapatid
thank you so much for dropping by lods!
Galing mo bos
thanks lodi, my mga videos pa tyo jn. p like nlng p share, kung my ktanungan comment lng lodi, sagutin ntin yn. basta related sa video lods.
gusto ng kuya ko to tutorial
refer mo ang channel ko lods, thanks for watching
Temsek kapated nice sharing
thank you so much,
sana sa pakikinig pwede ng matuto kagad kaso wala talaga akong talent when it come to electricity
yun na nga ma'am, hehe, pero thanks for watching.
Maganda yong snake Plant mo sa likod mo kabayan . Nakikinig lang po ako kabayan . No how talaga ako sa ganyan .
tanim ni mother, hehe dami nakakapansin nyan.thank you so much.
Lakers show 👍shout out nman idlo from UAE watching. 👀
sige lods, sa next video. stay saafe tayo sa mga galawang electrical natin.
First
thank you so much ka chismisan
@@galawangelectrical watching here again inulit ko kase ung una play ko lang until ma tapos d ko naring
@@LoveVlog888 thank you so much ka chismisan,
Pwede din naman po wye transformer gagamitin kapg 3phse need ni custumer. Hindi nga lang magagamit ang neuttal terminal.
yes pwedeng pwede naman lods, as long na mabigay nila ang gusto ng costumer, mpa wye yn or delta. sa tapping lang nman yan.
Salamat kahit mabilis mag change image. Milder shifting presentation lodi
try ko ulitin yn ng mas mabagal bagal lods.
Nkka antig tutorial mo brooo
thank you so much,
yan ang hindi ko pa maintindihan yang 3phase na yan. pero baka sa video na ito maunawaan ko na sana.👍
watch mo lng lods, then mag ask ka question.
Sir good morning
good morning to you lods, madami pa tyong mga vieos jan. anu itatanong mo lods?
Bosss thanks sa informatoin.. 😁👌 question lng po ok lng ba yan kahit isa lng ilalagay kung breaker?
sa line to neutral/ground pwede isa lang lods. sa line to line need mo 2, i mean pair.
Idol 3phase na nema breaker gamit ang singel phase power supply pano wiring diagram nun
kung match sya sa wire mo lods, i serries mo lang yung dlwang terminal. lagyan mo ng jumper ang 4 and 5 na terminal ng breaker. kaya ang incoming mo 1 and 3, at ang load side mo 2 and 6.
Lk....21 sbcb 👍🌹🥰 very nice video 👌
Thank you so much 😊
boss any idea wiring ng 3phase breaker to doublepole na 200amper breaker. .. . curios lng boss
yes jan lang din sa video lods, sa 3phase kalang kukuha ng power, para sa 2pole na breaker mo, ano need nilang power? check mo muna line to line ng 3phase mo, ano reading ng line to line? ano reading ng line to neutral. kung anu need na power sa 2pole breaker, yun lang ilagay mo sa 2pole, kung line to line eh 440v, at need ng 440v sa 2pole, so pwede mong gamitin ang line1 or line 2 para sa 2 pole mo, pwede ding L2 and L3, or L1 and L3, pero check mo muna ang mga loads mo, every line, kasi ang laki nyan 200A kelangan maging balance padin ang pag kukunan mo na 3phase.
Good day Sir Knowle's, tanong ko lang regarding sa voltage protector monitoring relay dual display, puwede ba sa isang 3 phase monitoring with power-on-delay and over un voltage protection in 1 device (Taxnele), ikabit-i-input ko ang supply na single phase (condemned ko yong isang terminal ng 3 phase?) at kukuhaan/I-output ko rin ang single phase 220volts line-to-line 2 wires?... Line-to-line kc d2 sa Laguna. Para magiging line-to-line single phase na lang ang 3 phase? ... Thanks
pag mga ganyn lods na 3phase na monitoring, hindi yan pwede sa single phase, meron ksi yng phase sequence, hindi yan gagana kung hindi 3phase ang ilalagay mo at kung mali ang phasing ng nilagay mo. every phase kasi ang minomonitor nyan. madami sa online nabibili mga pang single phase.
@@galawangelectrical 👍Thanks Sir Knowley's
Sir paano suplayan ang 3 pole na breaker ng singe phase na generator
ang breaker ai switching lang din yan lods, kung 3pole ang breaker, para ka lang nag switch ng 3 sabay sabay, ganun lang yan. now ang magiging supply mo incoming ai single phase galing sa genset. ang out mo ai single phase lang din, 2 wires yan, 2 wires lang din out nyan. so kung nag IN ka sa breaker 1&3 ng genset mo. so lalabas yan 1&3 din. walang laman ang 2 ng breaker.
Lods tanong ko lang po ulit 220 po ba ung boltahe ng 3phase circuit breaker na ginagamit sa mga conviniance store?
kung 3phase ang power source ng isang convenience store makikita mo agad yan sa service entrance lods, kung 3phase 4 wires yan or 5 wires. sa pinas 220v ang single phase na ginagamit dito satin. kung galing sa 3phase yan, gagamit ka lang ng 2 wires para sa single phase mo na 220. pero kung may pag kamitan ng 3phase, 3phase gagamitin. nag papalagay sila ng 3phase source kasi need nila may pag gagamitan or masyado madami ang load, kaya 3phase ang ginagamit. kaya pag ganyan kelangan may volt meter ka lagi.
Sa 3 phase+ ground sir line 1 at line 2 is 220v Yung ground wire sir pede I connect sa 3 prong outlet
yes lods, grounding yun. pero check mo maige lods, use volt tester. delta connection yan 220v 3phase. line to line ai 220v. means walang neutral yan. pwedeng naka HOT LEG yan. sa isang line naka bond ang ground. mostly mga industrial ang may mga power na ganyan, saan ba yang tinatanong mo?
pwde ba boss ung 3phase breaker sa poste gwin main breaker?
yes pwede yan basta kasya sa box nya. pwedeng 2 terminal lang gamitin mo. pwede yang 3 terminal gamitin, pwede din.
Hello help naman po..may spiral mixer po akong nabili 380V 3phase kw 1.8 A 4.7 ano po magandang gawin...
kung may nag co convert ng 3phase to single phase, pa convert mo yung mixer, option 1 yn, option 2 bili ka ng transformer. bk my nabibiling single phase to 3phase .
paps good evening try lo lang ask kung nag ccoconvert ka ng welding
machine 440v 3 phase to 220v single phase kung hindi kindly advise po sir kung anong gawin ko pra magamit ko ang weldin machine Raynaldo Dasoc Tanza cavite maraming salamat sa sagot
hindi ako nag coconvert ng ganyan lodi, inverter type ba welding machine mo? yung mga ganyan is ginawa for 3phase talga, now kung i convert yan, sa analyze ko is hihina ang welding machine, kung ma convert man.
Kuys, tanong ko lang po. Papaano po malalaman kung balanced pa yung connection mo. May video na po ba kayo? kung wala pa, pa explain naman po. Thank you.
wala pa akong video ng ganun lods, mejo busy tyo sa installation. panu natin malalaman kung balance pa, means matagal ng naka isntall ang panel na 3phase, pag bago palang makita mo yan sa blueprint nyan load schedule, makita mo jan kada phase. pero kung matagal na like nga yung tinatanong mo, is kelangan mo ng amp meter, or clamp meter. every phase is kelangan mo i check L1 L2 L3, dun mo makita kung balance pa o hindi na. may time makikita mo yan na hindi na balance, may cause din nyan is yung nag loose na ang connection, kaya may preventive tayo.
@@galawangelectrical Kuys maraming salamat sa sagot na to. Sobrang laking maitutulong sakin nito. Solid ka kuys
sir. L1 L2 L3 live wire po
3 phase panel po gamit
need ko lang 220v
bypass ko ba po L2 L3.
L1 lang po gagamitin ko
jumper na lang sa L2 at L3
wala kng i jumper sa 3phase lods, sabog ka jan. may volt meter kaba? check mo muna line1 at line2, line2 line 3, line3 line 1. pag na reading mo 220v lahat, jan ka kukuha ng 220 sa line to line. pag mataas ang reading mo, check mo line1 at neutral, line 2 at neutral then line 3 at neutral. pag na reading mo 220v. jan ka kuha ng 22o mo. line 1 at neutral. or line2 at neutral or line3 at neutral. ganyan ang 3phase power lods.
DO you have solutions for a line to line generator producing 220V to change it to line and neutral pls? My inverter would never read power from this type of generator! And I badly need to charge my Tomatech 7400 Hybrid Solar Inverter?
for what i know about generators, generators are mechanically operated. it generates power mechanically to electricity. so if it is designed for line to line output, you cannot change it. other wise you can use transformer,
lodi...ask ko lang po..bakit po nag sasabay mag trip off ung 3 cut off switch ng 3 transformer....
3phase lods. pg unbalance na. at malaki ng ang unbalance, matic trip.
Sir sana masagot po Ano ba ang tamang pag sukat or standard based on PEC niyan sa utility box ng mga c.o,switch,acu switch and panel board gitna ba or sa ilalim or ibabaw ng utility ang pagsukat and panel board??salamat po
sa gitna ang sukat lods, pero mag depende yan sa gagawaan mo, kung mag request sila na taas or babaan, gawin mo. may mga factor din bakit nababago ng ganyan. may ibang area prone sa flood. kaya mas gusto nila na mas mataas. kung walang sinasabi. standard gawin mo. sukat sa gitna lods.
@@galawangelectrical salamat lods opo naka depende nga pero akin lang po malinawan man lang halimbawa stadard 140cm sa switch ay gitna pala ang sukat,,salamat lods
@@paanovlog3296 yes lods gitna lagi ang sukatan
👍👍👌👌♥️❤️
thank you so much friend
Sir kong 3phase main power sa main cb.ang branches single phase cb.wala npo polarity.line to line.salamat sa reply
walang polarity ang AC power lods, sa 3phase power system may tinatawag na delta at wye connection. ang delta ai 3phase power 3wires plus ground. ang wye ai 3phase plus ground and neutral 5wires. so pag sinabing 3phase pwedeng delta pwedeng wye. now sa sinabi mo 3phase ang main breaker then branches single phase. mag babase ang single phase mo sa gamit mong system xconnection ng power, delta or wye. kung 3phase delta ka, ang branch mo ai line to line. meaning L1 at L2 or L2 at L3 or L3 at L1 ang single pahse mo. now sa wye system power system. pwede kang gumamit ng Line to line kung kelangan mo ang voltage na ganun para sa single phase, at pwede ka din kumuha ng single phase na line to neutral. meaning pwede ka mag line to line or line to neutral. depende sa voltage na gagamitin mo.
sir ano pwede gamitin na breaker 3phase to line to line single phase connection. Meron siyang 7 aircon at ano kaya breaker gagamitin?
kung 3 phase line to line power nyo, at need nyo ng single phase lang, depende sa output ng line to line at line to ground. kung line to line ang gagamitin mo, 2pole breaker gamitin mo lods. ang ampere depende sa AC na ilalagay mo. ilang HP ba?
Pa help naman boss pano ang wiring ng 3phase service entrance hanggang panel board line to neutral..ilang wire ang lalabas sa service entrance
pag 3phase line to neutral lods, 5wires yan. 3phase + neutral +ground
Sa 3phase bos main line..wla ba problema kng individual pvc Ng wire example 100mm ground flor papunta 2nd flor..or dpat sabay ang 2wires sa pvc. ..
dapat mag kakasabay sila lods, kung magkahiwalay, yung pagitan nyan is nag kakaroon ng reaction lalo n akung mataas ang load, tas kung may metal sa pagitan nila is may posibilidad na mag init. kaya dapat sama sama.
Panu yun lods ang abang is 3tubo #2 bali mgkatabi lng lahat..My cause din ba mg init
@@elmerespana7232 kung mag kakatabi naman lods wala namang maging cause yan. wag lang yung masyado mag kakalayo, depende rin naman yan dun sa loc. yung pinanggalingan yung pinag akyatan. isa din yung mga yon sa factor na maging cause. anu yung lugar ng pinag daanan ng pipe, then sa riser anung lugar ba yun. sa tingin ko naman di naman yan padaanin ng nag layout nyan, kung talaga may risk. kaya ok lang yan lods.
@@galawangelectrical aq ng abang lods kaso dq alam my ds advnce sa 3phse pala kng mgkahiwalay sa pvc..salamat sa idea lods..dagdag knowledge..
Pede ba gamitan Ng 3phaae busbar Ang 3 phase mdp para sa tatlong panel board at mabalance Ang load example MDP then busbar to 3 panel board
pag mga ganyan lods, malalaking panel yan. like mga switch gear. busbar ang mga ginagamit na main jan. para mag distribute per panel. kung maliit na panel, pwede namang wire din ang gamitin. so from main distribution mo, pa punta sa panel1 mo or pati sa panel2. pero need mo ng tamang size ng wire para jan. check mo yung total load ng kada panel, yun ang pag babasehan mo ng size ng wire.
@@galawangelectrical thanks sir
@@christian714 welcome lods
4:29 boss good day po, ask ko lang kung jan ba output na black and yellow pareho ba yan hot wire din? halimbawa po pareho ba yang black and white ng voltage tulad ng 120-120?
yes lods, jan is line to line yan, parehas hot. kung 3phase 220, kung line to neutral 110 to 120. parehas meron,
@@galawangelectrical samalat boss
@@BossKajo your welcome lodi
@@galawangelectrical mali yata lodi...L-N 120V , L-L 208V at L-N 110V , L-L 190V...L-L 220V , L-N 127V
Sir yung tnatawag bang 3phase 220v yun din ba yung 380 delta?
pag sinabi mong 3phase 220 is phase to phase nya is 220 lods, kung 380, phase to phase 380.
Sir, pano wiring diagram may generator ako 380V 5kva. Gusto ko gamitin sa bahay. Pwede ba ako makakuha 220V dun?
3phase ba lods? kung 3phase ang genset mo, baka maka kuha ka ng 220v jan, kelangan mo ng volt meter para sure ka.
Lods ilang volts poba ang L1,L2,L3 sa 3 phase papuntang mainbreaker
depende sa provider lodi. depende sa pangangailangan sa pag gagamitan. lahat ai nggaling yan sa 3phase. pero sinusukat yan by phase. pag sukat or metering ai lagi 2 wire ang i meter natin. may multi meter ka, i test mo voltage, 2 test probes mo black and red sa L1 & L2, or L2 & L3 or L3 & L1. jan mo pwede sukatin ang voltage. now kung may power voltage ka ng 220v 3phase, meaning pag nag test voltage ka L1 L2 dapat 220v yan kung L2 L3 dapat 220v pdin ayn kung L3 L1, the same padin dapat. may iba ibang power voltage may 220v 3phase, may 380v 3phase, may 440v 3phase, merong matataas pang voltage depende nga sa pag gagamitan. then may 3phase 3wire may 3phase 5wires means my neutral.
Ask ko lang newly.. pag 3phase line wire san kalimitan ginagamit..?
then ang mga appliances naman ay dalawang linya lang.. ang kailangan L1 and L2.. (except sa ground)..?
Explain..
ang single phase or 2 wire na gingamit natin normaly sa mga bahay eh galing yan sa 3phase lods. maliit lang ang demand sa mga residentials kaya hinahati hati nila yan para sa mga kabahayan. kung line1 line2 ang ginagamit mo, ang kalapit mong baranggay line2 line3 naman ang gamit, then sa sunod na baranggay line3 line1 naman. yan yung balance ng 3phase power. kaya minsan mapansin mo pag brown out may time sa inyo walang koryente sa ibng baranggay meron, pag nag punta ka sa kalapit baranggay mo na line2 line3 ang gamit, dimo iisipin na line2 line3 yun, ang alam mo lang line1 line2 din yun katulad ng ginagamit mo sa baranggay nyo, same thing din pag nag punta ka dun sa susunod na baranggay. yun ang basic ng electricity ng single phase power source. kaya mapa line to line or line to ground parehas lang yan na 2wires. parehas galing sa 3phase. sino gagamit ng 3phase? yung nangangailangan ng mataas na demand. like mga pabrika, mga buildings, ang jollibee gumagamit nyan. may mga gamit kasi na 3phase ang need na power. sana eh na enlighten kita sa paliwanag ko lods. pag may di ma gets, tanong ka lang uli hanap natin ng ibang way na paliwanag i try ko sa ubod ng aking kakayanan. stay safe sa galawang electrical.
Sir sa line to neutral na connection po sa service entrance. Kapag ginagamit na po ba yung mga load sa bahay may dadaan na rin na current sa neutral wire? Ganun po ba yun? Hehe 😁
kung wala pang load is naka stand by na sila jan lods, so from service entrance bumaba ng cutout, pumasok ng panel mo then nag distribute sa mga outlet, is anjan na ang power lodi naka stand by na. once na nag ka load yan is gagana na ang power, ang kuryenta para mapagana ang load. ang kuryente is going out to source the returning to the source, kaya gumagana ang load. kung single phase line to neutral/ground kayo, ang neutral nyo is naka bond sa ground yan, kahit kapitan mo yan kahit naka apak ka sa gorund is dika ma shock. pero once na madikit ka sa hot line yun yung line 1, is ma shock ka, so hindi lumalabas ang power sa line 1 at sa line1 or neutral, kundi yung sabi ko nga before, ang kuryente is leaving the source then returning to source, paikot ikot lang yan habang may load. kaya tayo nakaka consure na current.sana na gets mo lods, if hindi, ask ka lang then elaborate pa nating maige hehe.
Paano yung 400 volts kinakaya ba ng mga outlet yun dba masyadong malakas
Yung red yellow blue 400v or 380v ba lahat yun?
Idol pano tong elisi namin tatlo wire kaso yung pag kakabitan nya dalawa lang
baka ground yung isa yan lods, pwede na dimo na ikabit yan kung wala at dalawa lang pag lalagyan.
Taga US ako. Can that be transformed to 120. I want to create 120v plugs for my USA units. That way no need for a transformer.
yes lods, sa US 2 lines 1 neutral. if you use 1 line then neutral you can get 120v and if line to line 240v, but much better to check first in the panel lods, kung may multi meter ka, check mo voltage.
@@galawangelectrical you didn't answer my question. Are you an electrician? Can I wire the panel to get 120v was my question.
Malinaw pagkkapaliwanag kaso masyadong mabilis dpat konting hinay lng lalo sa mga baguhan mahirap sundan
napansin ko nga yan lods, sa pag kaka edit ko, mas yado ko kina cut kaya tuloy tuloy salita ko hehe. noted yan thanks sa feedback.
G'd eve Lodi... P2ro nman Lodi... Kc ung main breaker nmin nka 3 phase sya... Pro manga brandches nya nka single phase siya... Gz2 ksi ng my Ari Lodi mag lgay kmi ng 3 phase... Pno connection Lodi... Sna m2lngan m ako slmat Lodi...
kung 3phase ang power source nyo, so need nyo ng 3phase na branch din. line to neutral ba ang single phase nyo? kung line to neutral ang mga single phase nyo, means single breaker lang gamit nyo. ok yan makaka kuha kayo ng 3phase na branch jan, o 3 breakers lang gagamitin nyo. mas ok kung mya multi meter kayo madali nyo ma check. check mo uli yung video lodi,
brod masyado ka mabilis masalita. maging mas better and video mo kung medyo lagyan mo ng pause ang salita mo. para kasi nagmamadali ang dating mo...maganda na presentation mo pero halata na binabasa mo ng derederetso kasi walang pause and parang robot na derederetso...
thanks for watching lods, madami pa tayong mga videos jan. comment lang like & share. thanks.
Boss tanong ko lng po sana. .pano po ikabit ung single phase line ng bahay to 3 phase ng generator. .salamat po
single phase lang din gamitin mo sa generator mo lods, anu yan gamitan mo ba ng transfer switch? yung single pahese mo hindi mo pwede gawin 3phase lods, ang 3phase pwede mo gawing single phase. kung anu supply sa bahay yun lang kunin mo sa generator, kung line to line 220V yun gamitin mo.
Sir pwede ko pa ba gamitin ko ang 3 phase dito sa probinsya namen na line to neutral ?
diba line to neutral naman kayo jan, line to ground tawag jan sa inyo. naka wye ang system nyo, kaya naka ground ang neutral. yes pwede kayo gumamit ng 3phase, mag request lang kayo sa provider nyo lods.or mag apply kyo ng 3phase.
Boss Lodi magkano per day mo? As electrician salamat idol sa reply...❤
depende lods, 800 to 1k. oncall labor. kung may mga i check trasing. pag installation works iba naman yan lods lalo na pag malakihang work kino kontrata na yan.
Thank u lods more vlog pa ha para may idea n Ako 👍🙏
Idol lods tips naman.. bibili kasi ako welding machine pero ung model na bibilin ko is dalawang klase meron syang 220v only 1 phase at 3 phase meron 220/380 at 440v ata.. mahal ng konte ung 3 phase.. alin kaya maganda bilin? Or alin malakas 3 phase o 1 phase
wala kang pag saksakan ng 3phase lods, pang industrial lang yan. kung sa bahay or workshop mo lang gamitin, or na ngontrata ka. single phase lang bilihin mo lods. para kahit san mo dalahin magamit mo single phase.
Isang 350amp tig weld kasi bibilin ko lods pero 3 phase sya tas isang 230a tig 1 phase ung 1 phase pag outdoor ung 350amp sa bahay lng need b electrician para baguhin electric wire sa bahay para maging 3 phase?
@@djerwin1975 ang 3phase is apply yan sa service provider, di magawa ng electrician yan.
@@djerwin1975 kung papabago mo yan, papalitan ang service entrance mo, ang meter. meralco ba kayo? may mga nakikita akong converter type na mga tig and mig 220v lang.
@@djerwin1975 pero kung need mo talaga ang 3phase power, apply ka sa provider nyo, sabihin mo pababago mo from single phase to 3phase.
Panu po ma convert ang 3phase 440v to single phase 220v
kung delta ang power source mo, dika maka kuha ng 220 lods, pero kung naka wye ka, pwede ka maka kuha ng 220, isang hot line at neutral lods.
nag.mamatter bah kung 220v or 380 or 440v Yung 3phase to single phase?
yes lods, its matter. specially sa wye , may neutral kung single phase ang gagamitin. pwede ka kasi mag single phase sa line to line, pwede ka mag single phase sa line to neutral. depende sa gagamitin mo.
master pag 3phase ung service entrance...anung meter base Ang ginagamit...salamat
may 7jaws na ginagamit lods square box, para sa 3phase.
@@galawangelectrical slamat master
@@nitzmendoza3675 walang anuman lods
Sir my generator ako 3phase e connect ko sa single phase line to neutral connection
check voltage ka lodi, check mo line to line, at line to neutral first. para sa voltage na need mo single phase.
sir pag single phase line to neutral.. sa panelboard po idadaan parin ba sa breaker yung neutral?
pwede na hindi padaanin sa breaker ang neutral, sa 3phase ang neutral is 0 yan, naka bond din yan sa ground. sa single phase at ang line2 mo is 0, neutral/groubd , pwede mo dina padaanin ng brekaer lods.
@@galawangelectrical thank you engi
@@keithcmd9431 your welcome lods
Paano mg line ng 110 sa line to neutral
sa single phase line to ground system. dika na makaka kuha ng 110v lods. need mo na mag step down transformer.
Boss lods Anu po b single phase
Anu sukat ng panel single phase
single phase yung mga pangkaraniwang ginagamit sa residentials lods, single phase lang yan. sa size ngpanel eh mag bbase yan kung ilang brekers ba kakailanganin mo, kung isang main at isang brach lang kailangan mo so maliit na panel lang yan.kung need mo ng maraming breaker so malaking panel ang need mo, so kung need mo 8ways panel, sa single pole 8 breakers yan, sa double pole 4 na double pole yan. meron 8ways , merong 12ways meron 16ways.