DIY PANO GAWING SAFE ANG UNGROUNDED CONVENIENCE OUTLET Basic Electrical #24

Поделиться
HTML-код
  • Опубликовано: 11 окт 2024
  • In this video i will show you all Lods, How we can make the Ungrounded Convenience Outlet to a much and safer Outlet, But for the GFCI you need to have the grounding for it. so all the ungrounded outlet that is loaded in the GFCI will be safe to use.
    DISCLAIMER!!! I am not a professional, but I can contribute my gathered knowledge, Experience, and skills in this video
    If you have any questions, feel free to comment down below.
    PA LIKE COMMENT & SHARE NALANG MGA LODS, SALAMAT
    CHANNEL MEMBERSHIP / @galawangelectrical
    #GFCI
    #BasicElectrical

Комментарии • 205

  • @ellusion3725
    @ellusion3725 3 года назад +2

    Nice tutorial lodi
    Very helpful anf useful tips at napakalinaw ng pag kakapaliwanag. Dropping my support here
    Keepsafe always

  • @jatag
    @jatag 3 года назад +1

    Very useful talaga to Lods para Iwas accidents like nung bata .. very helpful talaga ang mga blogs mo.

  • @papapiggytvintheuk2257
    @papapiggytvintheuk2257 3 года назад +1

    Salamat mate sa isa na namang makabuluhang tutorial and tips good morning...

  • @rowenalagria6253
    @rowenalagria6253 3 года назад +1

    Thanks for sharing this paano gawin safe ang ungrounded convenience outlet.

  • @sofiaandcheryl
    @sofiaandcheryl 3 года назад +1

    Kailangan tlaga sakto standard pra Wla n ma kuryente. Very helpful tips.

    • @galawangelectrical
      @galawangelectrical  3 года назад +1

      yes tama lods, iba nag nasa standard ang ginagamit and work. thanks for watching!

  • @coolettes1323
    @coolettes1323 3 года назад +1

    very helpful po ito... para iwas sakuna. Loved your videos po!

  • @ReynaandKeithCanada
    @ReynaandKeithCanada 3 года назад +1

    Maganda tong tutorial mo lods very helpful sa kababayan natin
    Tibay ng mga ads

    • @galawangelectrical
      @galawangelectrical  3 года назад

      yes lods, para ma open na dito para sa mga standard na dapat gamitin. hehe anu mga ads jan?

  • @SamanthaUyTV
    @SamanthaUyTV 3 года назад +1

    Iwas alsidente, napakagaling mo kapatid mag inform about home electricals

  • @ngocvanleusa3678
    @ngocvanleusa3678 3 года назад +2

    Underground wire outlet tips are very helpful enjoy it fully as always thanh you my friend

  • @LivingwiththeGoodman
    @LivingwiththeGoodman 3 года назад +1

    glad to be back here again my freind
    watching here always with your very useful ideas when it comes to electric outlets
    Happy wednesday

  • @bongcuartousaamericanpinoy2517
    @bongcuartousaamericanpinoy2517 3 года назад +1

    You are doing a great job kabayan 👍 Malaking tulong sa lahat na nagnanais matuto sa Electrical 😉

  • @willycanlas9393
    @willycanlas9393 3 года назад +1

    thanks Lodi sa new tutorial 👍👏 GFCI safety sa mga childrens.♥️

    • @galawangelectrical
      @galawangelectrical  3 года назад

      your welcome lods, thanks for watching!

    • @willycanlas9393
      @willycanlas9393 3 года назад

      @@galawangelectrical 👍♥️

    • @MaryannDeocariza
      @MaryannDeocariza 10 месяцев назад

      Ask lang ako lodi,, hindi ba nakaka kuryente ang mga outlet pag may GFCI??

  • @NaningFrancisco
    @NaningFrancisco 3 года назад +1

    Lodi, dito po sa hk, sa mismong electric box my circuit breaker na sya,tapos may kanya kanyang outlet kung yun linya kusina halimbawa my ng apoy na adaptir, magbreak yun automatic

    • @galawangelectrical
      @galawangelectrical  3 года назад

      yes lods, tama dito din sa pinas if nasa standard ang sundin ganyan din yun lods, iba iba circuit, hiwahiwalay, para di apektado lahat. then kung anong breaker ba ang dapat, iba iba kasi ang type ng breakers, kay adepende sa pag gagamitan depende sa location. thanks for watching lods.

  • @e-benguetlynden2323
    @e-benguetlynden2323 3 года назад +1

    Wala na ako masabi idol, you are the man.

  • @KataTukuTV
    @KataTukuTV 3 года назад +1

    Ang galing lodi salamat sa walang sawang tutorial mo

  • @LoveVlog888
    @LoveVlog888 3 года назад +1

    Lods Pinanood ko ulit at share ko sa kapatid ko kase nag viral sa social media yong batang nakuryente dahil sa pag saksak ng kutsara kaya sabi ko panoorin ito at gawin sa bahay nila

    • @galawangelectrical
      @galawangelectrical  3 года назад

      thank you so muc sa share ka chismisan, thanks din sa laging pag suporta god bless ang hava a great day sa inyo jan!

  • @rubygemstoneshares
    @rubygemstoneshares 3 года назад +1

    Nice. Thank you for sharing, friend. Have a nice day!

  • @titodudblaggerrr3274
    @titodudblaggerrr3274 3 года назад +1

    Salamat dito lods, gamit to para sa may mga anak. Salamat sa pagshare and stay safe

  • @luisarielsalvacruz5151
    @luisarielsalvacruz5151 10 месяцев назад

    Nice one sir ganun pala gagawin kesa magpakabit pa ng wire para sa ground ng pangkalahatan

    • @galawangelectrical
      @galawangelectrical  10 месяцев назад

      ok din yn lods, khit mahal sure nman na safe. basta i test lng monthly

  • @amytyson3164
    @amytyson3164 3 года назад +1

    HELLO BROTHER YOUR VERY GOOD DOING THIS THANKS FOR YOUR SHARING

  • @indaymaria2255
    @indaymaria2255 3 года назад +1

    another safety tips thanks for sharing very helpful for us

  • @winaflorstv
    @winaflorstv 3 года назад +2

    Wow brothaaa napakagaling mo thank you for sharing this one

  • @LifeTogether000
    @LifeTogether000 3 года назад +1

    This is so interesting and very informative thanks for sharing

    • @galawangelectrical
      @galawangelectrical  3 года назад +1

      Glad you enjoyed it, thank you so much for dropping by!

  • @RenAnneJ
    @RenAnneJ 3 года назад +2

    Tamang tama ito lods para safe sa mga bata

  • @ufofamvlogs2431
    @ufofamvlogs2431 3 года назад +1

    Thanks lodi sa pgtuturo malaking tulong to sken

  • @juliesdiary7229
    @juliesdiary7229 3 года назад +2

    wow grabe ang galing mo friend

  • @JRALMANONCHANNEL
    @JRALMANONCHANNEL 3 года назад +1

    So informative Kasuki.Salamat

  • @joverossuk5421
    @joverossuk5421 3 года назад +1

    As usual very informative and great tutorial kapatid

    • @galawangelectrical
      @galawangelectrical  3 года назад

      Glad you liked it ma'am Jove, thank you so much for watching!

  • @meralynparisvlogs7328
    @meralynparisvlogs7328 3 года назад +1

    Very informative video lodi. Keep it up.

  • @LocalElectricianPH
    @LocalElectricianPH 3 года назад +1

    Fully watched lods. Pati ads😎

  • @PRAYAGRAJVIDEO
    @PRAYAGRAJVIDEO 3 года назад +1

    Great video! Thanks for sharing. New friend here!

  • @CloverSkyblue
    @CloverSkyblue 3 года назад +2

    Meron lang ako tanong, Why is it too expensive to have the electric lines transferred to another house from old house?

    • @galawangelectrical
      @galawangelectrical  3 года назад

      it depend on the service provider ma'am, and sa gagawa, sa place nyo its to expensive talga mag hire ng electrician, here sa pinas, kung malapit lang palgipatan is kaya na ng electrician ilipat, kaya naka menos sa rent.

  • @NovieTubeChannel
    @NovieTubeChannel 3 года назад +1

    Watching here po ang galing naman.

  • @vergievilandovlog120
    @vergievilandovlog120 3 года назад +1

    Done all bell my friend thanks for sharing

    • @galawangelectrical
      @galawangelectrical  3 года назад

      thank you so much lods, yes done nadin lods, thanks for watching

  • @FaluBloggers
    @FaluBloggers 3 года назад +1

    replay kapatid

  • @helenaquejano2930
    @helenaquejano2930 3 года назад +1

    naku ang galing mo kami nag babayad pa ng gumagawa nyan

    • @galawangelectrical
      @galawangelectrical  3 года назад

      thanks you so much for watcing, yes kaya nga. atleast may idea kyo about outlet.

  • @gwapangmarias993
    @gwapangmarias993 3 года назад +1

    Thnks for sharing good job

  • @rudelinocencio9481
    @rudelinocencio9481 Год назад +1

    Good morning Sir ask ko lang kung wala talaga ground (line to line po kami) pwede po ba maglatag ng linya ng ground then using the ground po ng PLDT o gumawa o magbaon ng another ground rod? Salamat po.

    • @galawangelectrical
      @galawangelectrical  Год назад

      watch mo to lods, ruclips.net/video/tIP-uXh38Cgh/видео.htmlttps://ruclips.net/video/YimXNBOi7uo/видео.html
      ruclips.net/video/Q18zB5_EPGU/видео.html

    • @rudelinocencio9481
      @rudelinocencio9481 Год назад +1

      @@galawangelectrical salamat sir

    • @galawangelectrical
      @galawangelectrical  Год назад

      @@rudelinocencio9481 walang anuman lods, tanong ka lang lods kung my dika maintindihan jan.sagutin ko yan.

  • @vergievilandovlog120
    @vergievilandovlog120 3 года назад +1

    Hello I am a new here thanks for sharing

  • @Mstrknk
    @Mstrknk 3 года назад +1

    for safety, great job here

  • @Hobichngoc25
    @Hobichngoc25 3 года назад +1

    good, thanks for sharing

  • @RobelynThiel
    @RobelynThiel 3 года назад +1

    watching here kapatid!!

  • @eliazargarcia2513
    @eliazargarcia2513 Год назад +1

    Lods, paano kung line to ground ang linya. Paano ang wiring sa line side ng gfci?

    • @galawangelectrical
      @galawangelectrical  Год назад

      ang principle ng electricity ai parehas lang sa single phase lods, 1 wire going out from the source, 1wire reterning back to source. sa panel mag ba bond ka ng isang terminal para sa grounding. ang grounded conductor at terminal. grounded conductor ai yan ang pinaka neutral or line2 ng single phase mo. sa line to ground system. iba kasi ang trabaho ng grounding lods, saka yung grounded conductor. so maging 3wires na yan. pag nag karuon ng leak sa line1, dadaloy yun sa grounding at yun ang masasabi sa GFCi naunbalance na yung current. kaya i trip na nya ito. now yung grounded conductor ang nag karuon ng leak. the same padin yan, kasi electricity going out from the source then returning from the source. mag kakaruon pain ng unbalance yan. kasi gawa ng principle.

  • @LoveVlog888
    @LoveVlog888 3 года назад +1

    Watching pa Lods

  • @Fernando-z2z
    @Fernando-z2z Месяц назад

    Salamat idol sa kaalaman

    • @galawangelectrical
      @galawangelectrical  Месяц назад

      walang anuman lodi, dami pa tyong mga videos jan. tanong lang kung may di ma gets, sagutin natin yan.

  • @lrvslimbibbo2803
    @lrvslimbibbo2803 3 года назад +1

    Full watched for u, this is amazing 😻

  • @JojoCruzSolano
    @JojoCruzSolano 10 месяцев назад +1

    sir papano yung mismong saksakan walang ground mga aircon at ref lang kasi meron ok lang ab yun

    • @galawangelectrical
      @galawangelectrical  10 месяцев назад

      para saan ba yung grounding lods? binibigyan safety nito yung gumagamit, yung bahay. nakokoryente tayo minsan pag nahahawak tayo sa mga bagay ng metal like ref, rice cooker, washing machine. kung may mga ground fault ito at walang grounding, may posibilidad tayo na ma shock kung mahahawakan natin yung metal na may ground fault. kaya mas ok kung malalagyan natin yung outlet na sinasaksakan ng appliances na metal ang mga housing or chasi.

  • @jomariesanchez5080
    @jomariesanchez5080 2 месяца назад

    Question po. installed na ung grouding ko sa outlets ko.
    kapag ung AVR or UPS or extension wires ay walang ground pin hindi po gagana ung grounding ng equipments na nakasaksak doon ?

    • @galawangelectrical
      @galawangelectrical  2 месяца назад

      yes lods, kelangan continous yan from equipment pa punta sa AVr mo, then pa outlet mo na my ground, and dapat yung ground ng outlet pa punta panel palabas sa ground rod, at ground ng service drop.

  • @SurpriseHunters
    @SurpriseHunters 3 года назад +1

    excellent upload dude! you keep posting these amazing videos!

  • @winaflorstv
    @winaflorstv 3 года назад +1

    Tambey here bro ulit 😇😇

  • @norbertgali9664
    @norbertgali9664 8 месяцев назад +1

    lodi pwede ba gamitin ang GFCI outlet para outlet ng shower heater

    • @galawangelectrical
      @galawangelectrical  8 месяцев назад

      ganun ang dapat na outlet ng mga heater as per code require. pero check mo kung pasok sa rating amp yung gfci na ilagay mo lodi, ilang amp yung heater mo? dapat the same din yan ng outlet.

    • @norbertgali9664
      @norbertgali9664 8 месяцев назад +1

      3.5kw po kc yung shower heater

    • @galawangelectrical
      @galawangelectrical  8 месяцев назад

      @@norbertgali9664 halos nasa 16A ang 3.5kw lods, kung maka kuha ka ng 16A or more than, mas ok lodi. pwede mo ilagay sa gfci. kung wala may breaker na gfi lods pwede din yun. pero sa normal operation kasi yung ordinary na outlet 16A yan uubra pa yan. kasi minimal naman ang gamit ng heater dito satin sa pinas. kaya pwede yun hanapin mo lods gfci 16A.

  • @ItsaBingThing
    @ItsaBingThing 3 года назад +1

    May natutunan na naman tayo Kapatid

  • @fretzcustodio5056
    @fretzcustodio5056 2 года назад

    lods gud am! thru n thru pla ung connection nyan. ty!

    • @galawangelectrical
      @galawangelectrical  2 года назад

      yes lods, pero may line in yan at my load side. pag gusto kasama sya sa safety ng GFCI sa load side ka mag dagdag, pwede kasi dimo padaanin sa safety, sa line in ka mag lalagay.

  • @carlotarog7471
    @carlotarog7471 Год назад +1

    Bro kapag may gfci na po ba, iwas electric shock na po halimbawa sa laptop habang nakacharge merong electric shock sa metal surface ng laptop..??

    • @galawangelectrical
      @galawangelectrical  Год назад

      ang GFCI lods ai para lang ma lessen then i trip yung device. ang advisable na location ng GFCI ai sa matutubig na lugar lang. like sa kitchen, sa toinlet, sa labas ng bahay na prone sa ulan na mga outlet. let say may GFCI ka sa room then grounded ang iplug mo, mag trip lang ang GFCI. kung makapitan mo may dadaloy padin sayo may shock padin. pero depende yan gaano ka tuyo or ka basa yung connection nung ground fault. mas tuyu mas ma feel mo yung shock mas basa mabilis mag trip ang GFCI. pero yan sinasabi na may problema kaya nag trip. yun ang need na ayusin. ang mga ganyan lods eh parang first aid lang yan. hindi nyan gagamutin ang sakit.

    • @CedieObrero
      @CedieObrero 6 месяцев назад

      Ano po maganda solusyon pag may electrical shock sa metal cased laptop when plugged in?

  • @blaiseculong3187
    @blaiseculong3187 Год назад +1

    Pwede po bang saksakan ng UPS yung GFCI na outlet?

    • @galawangelectrical
      @galawangelectrical  Год назад

      ang mga GFI or GFCI ai may tamang location ng pag lalagay. mostly sila sa mga matutubig na lugar. like kitchen or bathroom. or sa labas ng bahay na pwede maulanan. sa tingin ko di ka mag lagay ng UPS jan sa mga lugar na yan.

  • @sofiaandcheryl
    @sofiaandcheryl 3 года назад +1

    First like

  • @emmanuelespinola1911
    @emmanuelespinola1911 3 года назад +1

    Paano po ikabit ang ground sa breaker ng aircon ? Wala kasi akong makita clip para sa I connect ang ground. Pls answer my question thanks.

    • @galawangelectrical
      @galawangelectrical  3 года назад

      hindi nilalagyan ng ground ang breaker lodi,

    • @emmanuelespinola1911
      @emmanuelespinola1911 3 года назад +1

      @@galawangelectrical para san yun may sign na ground sa circuit breaker ng aircon.? San nilalagay yun ground sa aircon,?

    • @galawangelectrical
      @galawangelectrical  3 года назад

      @@emmanuelespinola1911 ang circuit breaker ay power na nag supply sa aircon lodi, sy ang protection mo pra sa short circuit at over current, ang ground is ground, kelangan mo ikabit sa ground lodi, sa earth. yung mga sign na ganyan is dun mo ikakabit sa earth. makikita mo ang ibang metal na chasing ng mga gamit like nga aircon or ref, or mga oven or washing machine, is may green na cable naka kabit sa metal na chasing ng equipment ntin, kelangan naka ground yan lodi, sa earth. sa FB may page ako lods, same din mga electrical din andun, knowleys din name ko, pede mo ako pm dun, pra mas malinawan ka mag send ako ng mga sample ng drawing.

  • @OniBaal-d3s
    @OniBaal-d3s 4 месяца назад +1

    Paano ka lods kung pang ilang electrician kana?yong na unang Ng install Hindi nilagyan Ng ground?Ani Gawin ka lod?

    • @galawangelectrical
      @galawangelectrical  4 месяца назад

      depende sa maging trabaho. kung palit outlet lang, ok lang naman sa gfci kahit walang grounsing lagyan mo lang ng label na no grounding. now kung ang work eh re wiring na. dun kana mag dagdag ng pwede mo i install. like additional wire nga para sa ground.

  • @AlyzaMarieBeloncio
    @AlyzaMarieBeloncio 3 месяца назад

    Pede Po ba Ang gfci sa 30ahm breaker with #10 wire for shower heater? Pansin ko kasi puro 20ahm lang mga outlet

    • @galawangelectrical
      @galawangelectrical  3 месяца назад +1

      pag convenience outlet matic yan 20A yan. ang heater outlet ay hindi convenience outlet, special porpose outlet yan o SPO, ky malaki ang wire nyan ky mataas ang breaker nyan. so depende sa wattage ng ipapakabit mong heater. pwede nman mg GFCi outlet pero check mo ang Ampere Rating. kung ano kc ang demand ng heater na wattage rating, yung ang kelangan sa gfci din. kung mataas, meron din breaker na gfci pwede din yon lods. as long na papasok sa rating ng heater ang bawat isa ang wire ang outlet ang breaker.

    • @AlyzaMarieBeloncio
      @AlyzaMarieBeloncio 3 месяца назад

      @@galawangelectrical bale Yung heater Po is 5500 watts mag lalagay Po Ng sariling breaker sa main breaker na 30ahm TAs wire nya is 10. Anong receptacle Po Ang need ko? Wala pong 20ahm na receptacle.

    • @galawangelectrical
      @galawangelectrical  3 месяца назад

      @@AlyzaMarieBeloncio mas ok kung i direct mo yung wire sa heater lods, sa loob ng heater may sarileng breaker yan. dun mo ilagay yung wire na #10. watch mo itong video ko na to. ruclips.net/video/BqrP8F6aDUU/видео.html

  • @AlfredoAmbulencia
    @AlfredoAmbulencia 5 месяцев назад +1

    Pwede bng gamitin Ang GFCI sa water heater

    • @galawangelectrical
      @galawangelectrical  5 месяцев назад

      depende sa water heater lodi, may mga water heater na may breaker sa loob at ang breaker nun eh may ground fault protection na. kung wala ang di plug ang heater pwede naman lods, safety padin nya yan.

  • @boyigna424
    @boyigna424 2 года назад +1

    Thanks

  • @jovenalsultan1435
    @jovenalsultan1435 Год назад +1

    Lodi, o lang ba na walang ground aircon outlet

    • @galawangelectrical
      @galawangelectrical  Год назад +1

      kung walang maging fault, ok lang. ang ground naka stand by yan lods, para kung mag karuon ng fault ang AC, dun palang gagana yan.

  • @vincecipriano2632
    @vincecipriano2632 3 года назад +1

    Thanks idol sa info tanong ko lang san po ba makabili ng gfci outlet

    • @galawangelectrical
      @galawangelectrical  3 года назад +1

      sa ace hardware meron lods, san ba location mo, pinas kba? wilcon meron din jan.

  • @kdmmixideas9821
    @kdmmixideas9821 Год назад +1

    OK lng po b kung walang ground? Salamat po

    • @galawangelectrical
      @galawangelectrical  Год назад

      sa mga naka tuhog sa gfci , ok lang wala, pero sa gfci dapat meron lods.

  • @rj4073
    @rj4073 26 дней назад +1

    pwede po ba yan kahit walang ground yung outlet na paglalagyan?

    • @galawangelectrical
      @galawangelectrical  26 дней назад

      yes pwede naman lods, pero may difference sila. pg merong grounding matic mag off yan pag nag ka tuon ng ground falt. sa walang grounding. ikaw or yung taong maka kakapit ng my ground fault ai pwede ma ground muna bago mag trip yung device. yun pag kakaiba nila.

    • @rj4073
      @rj4073 25 дней назад +1

      @@galawangelectrical di ko na gets sir. iba po ba ang kahulugan pag nakuryente na tao kumpara sa na ground na tao?

    • @galawangelectrical
      @galawangelectrical  25 дней назад

      @@rj4073 nakuryente ka kasi naka ground ka. ang tinatanong mo kasi ai kung pwede walang grounding wire. sabi ko pwede. kaya lang. pag wala. ikaw ang mag silbing ground wire. so makokoryente ka. compare sa merong grounding wire. dimo p nahahawakan yung my fault eh mag trip na kasi nga may ground wire. yan ang trabaho ng mg aground wire lods.

    • @rj4073
      @rj4073 23 дня назад +1

      @@galawangelectrical maraming salamat sir. na gets ko na. may mairerekomenda ka bang libro para mabasa.

    • @galawangelectrical
      @galawangelectrical  21 день назад

      @@rj4073 di ako gaano nag babasa ng books lods, mahirap intindihin pag pa basa. pwede pabasa na may halong watching ka ng video lodi. yung may paliwanag. pero ginagawa kong reference yang books lods, nec lang naman pinag babasehan ko. same din yan ng pec na addapted natin sa nec. ky ok lang na nec.

  • @hermansogue9179
    @hermansogue9179 Год назад +1

    Master ilang outlet Ang kaya Ng Isang GFCI?

    • @galawangelectrical
      @galawangelectrical  Год назад

      ang gfci ai design lng sa dump location, walang maraming location sa bahay na ganito maliban lang sa cr at sa labas ng bahay. kaya dirin malagay ng maramihan ito kung mag load nga tayo dito ng mga outlet. para sakin 5 lang, mas lalayo yung outlet na ikabit mo sa gfci, mag kakaruon na ng resistance yan. means hahaba na yung dadaanan ng fault bago maka rating sa gfci. bago ny i trip yun.

  • @Aquaticwonderstv
    @Aquaticwonderstv Месяц назад

    Lods okay lang ba yan GFCI kahit walang earth grounding? Dalawang wire lang kasi kinabet mo lods

    • @galawangelectrical
      @galawangelectrical  Месяц назад

      sa NEC pwede nman lods, pero dapat my level, my nksulat na ungrouded. ano yung difference ng meron sa wala? sa meron stand alone ma detect ng gfci yung ground fault i trip ny yung outlet. sa wala, pwedeng ikaw yung maging path ng fault. means makoryente ka din then sukatin ng gfci yung triping current imbis na yung sa wire. then sk nya i trip yung outlet. mabilis nman yan lods seconds lang yan.

  • @lifemotivationtv.8578
    @lifemotivationtv.8578 9 месяцев назад +1

    Lodi ilan outlet kaya niyang isama sa connection

    • @galawangelectrical
      @galawangelectrical  9 месяцев назад

      pag sa ordinary laki ng bahay lods, kaya nya yan isang buong circuit. pero check mo yung capacity ng gfci. kung 20A pwede mo ilagay sa isang buong circuit. pero kung 16A or 10A lang. pwede yan kalahati ng bilang ng outlet mo sa bahay.

  • @ronaldcajiles
    @ronaldcajiles 7 месяцев назад

    Lods so pede kahot walang ground wire kc wlng abang eh safe pa din at gagana pa din gfci

    • @galawangelectrical
      @galawangelectrical  7 месяцев назад

      dun sa walang abang ok lang lods, pero sa gfci dapat meron, pero sa tingin ko gagana naman kahit walang grounding, kasi nag a unbalance ang current.

  • @christian714
    @christian714 Год назад +1

    Sir ok lang ba na walang ground wire Yung gfci

    • @galawangelectrical
      @galawangelectrical  Год назад

      GFCI dapat meron lods, yung sa mga load na outlet, pwede na wlaang ground dun. dun din kasi ang daan nun sa GFCI.

  • @lharachastyyumul3653
    @lharachastyyumul3653 Год назад +1

    Pwede po ba gamitin yan sa shower heater kahit wala po groundings ang buong bahay?

    • @galawangelectrical
      @galawangelectrical  Год назад

      pag gfci need may groundng wire lods. jan sa video eh yung mga existing na outlet na wlang ground, naka kabit yan sa gfci na naka ground. so kung mag lagay ka nyan para sa shower heater, need may ground wire

  • @acemoordaliposon3809
    @acemoordaliposon3809 3 года назад +1

    Isang gfci ilang piraso outlet box pwede edogtong lodi?tnx

    • @galawangelectrical
      @galawangelectrical  3 года назад

      kung sa ordinary na bahay lods, mostly sa sala is may 3 to 5 na outlet, iba pa yung sa mga room, hahaba na kasi kung lalahatin pa natin, baka pwersado na yung unang outlet at wire, kasi tuhog tuhog nga diba, kaya para sakin gang 5 outlet lang lods.

    • @acemoordaliposon3809
      @acemoordaliposon3809 3 года назад +1

      @@galawangelectrical tnx lodi

    • @galawangelectrical
      @galawangelectrical  3 года назад

      @@acemoordaliposon3809 your welcome lods,

  • @moisesmoises-t3v
    @moisesmoises-t3v 4 месяца назад

    pano kapag nauna yang mga outlet bago gfci ok lang din ba gamitin? wala na bang lagayan ng ground yang gfci? kasi needq sa pc na grounded

    • @galawangelectrical
      @galawangelectrical  4 месяца назад

      pwede nman kahit sa huli yan, yan lang yung mag karuon ng protection. and mali yung term na need mo sa pc na grounded, pg grounded my problema. nag lalagay tyo ng ground, nk stand by lang yan, once na nag karuon ng problem sa unit mo ganing grounded means my partly positive na dumidikit sa kaha ng unit na metal, dun palang gagana yung ground wire dun tutulay yun imbis na sayo pg nahahawakan mo yung unit mo. so dapat my ground wire oitlet mo pa punta dun sa panel at papunta dun sa grounding rod nk baon.

  • @marioespolon3880
    @marioespolon3880 Год назад +1

    Kung sakali walang grounding ang naka connect sa gfci safe ba yan?

    • @galawangelectrical
      @galawangelectrical  Год назад

      kung mag karuon ng fault sa outlet na wlang ground, ang takbo nung fault sa gfci padin, may current transformer jan na pag nag karuon ng unbalance i trip padin yan. mag kkaruon yan ng difference pag sobra malayo yung outlet na load ng gfci. kung sa bahay lang siguraduhan lahos mag kakadikit lang yan. dun sa tanong mo, yes safe pa yan lods.

  • @jessiejhames973
    @jessiejhames973 Год назад +1

    lods yung existing wires ng convenience outlet pwedeng baliktaran yun kapag ikakabit sa line 1 and line 2 ng cfgi?

    • @galawangelectrical
      @galawangelectrical  Год назад

      yes pwede namna lods, pero we try dun sa best practices para sa work natin.

    • @jessiejhames973
      @jessiejhames973 Год назад

      @@galawangelectrical salamat sa sagot lods.may isa pa ako tanong lods.yung existing wires sa convenience outlet may naka splice.ok lang ba na hindi ko alisin yun kapag magpalit ako ng cfgi outlet?

  • @jamesianbracero1005
    @jamesianbracero1005 2 года назад +1

    boss pag wala po bang ground ung GFCI , functional parin po ba safe parin po ba?

    • @galawangelectrical
      @galawangelectrical  2 года назад

      kelangan meron grounding ang GFCI lods, jan kumukuha ang sensor kung balance pa yung current.

    • @jamesianbracero1005
      @jamesianbracero1005 2 года назад +1

      @@galawangelectrical bat po need pa ng grounding? kasi sa pag kaka intindi ko once mai unbalance sa current mag t trip ung GFCI. Sample pag ung isa line nabasa e nag cacause un ng unbalance so ayon trip agad c GFCI.

    • @galawangelectrical
      @galawangelectrical  2 года назад

      @@jamesianbracero1005 watch mo to lods, ruclips.net/video/l2rQgi4e34s/видео.html kahit hindi GFCI need padin ng ground. yes kung nag unbalance sa GFCI i trip nyan yan.

  • @johncruz1644
    @johncruz1644 3 месяца назад

    Sir, bakit po kaya dito sa pinas ay 2 prong lang lagi sa outlet, wala yung pang ground na makikita sa 3 prong.
    Safe pa rin pa po ba yun or possible naman lagyan ng neutral sa outlet pag nagpagawa ng bahay?

    • @galawangelectrical
      @galawangelectrical  3 месяца назад +1

      nuong araw khit sa america my mga old houses na walang ground lods, then unti unti nlng na momodified yn. sa ngayon nirerequired na sa ibang bansa yn. dito sa pinas ganon din yn nuong araw wla nman ganyan, pero sa ngayon unti unti ndin nilalagyan yun nga lng di ganon ka bilis ang panahon dito satin. isa ndin dahilan nagtitipid, keso nung araw nman daw eh wala non. sa ngayon pwede nman piliin lng yung dapat lagyan nyan. like nga yung mga sinasaksak ntin na metal ang housing like ref, oven. kc yun ang ms prown na pwede ntin mkpitan at ma ground tyo. ky ok lng sa mga outlet na 2prong lng. then dun k nlng mg lagay sa mga may metal housing like ref nga or washing.

    • @johncruz1644
      @johncruz1644 3 месяца назад

      @@galawangelectrical ganun po pala, gets ko na po.
      salamat po sa napakalinaw nyo po na pagkakaexplain.

    • @galawangelectrical
      @galawangelectrical  3 месяца назад

      @@johncruz1644 walang anuman lods, dami pa atyong mga videos jan.

  • @godofredocortina2925
    @godofredocortina2925 5 месяцев назад +1

    Bakit walang gruonding yan sir?

    • @galawangelectrical
      @galawangelectrical  5 месяцев назад

      pwede naman walang grounding lodi. basta markingan lang na ungrounded. na dedetect padin ng GFCI ang unbalance current kahit walang grounding.

  • @TonyBangayan-cp5uj
    @TonyBangayan-cp5uj Год назад +1

    Pag gfci ba no need na ang ground

    • @galawangelectrical
      @galawangelectrical  Год назад

      gfci need ng ground, kung ang mga i load mo dito na convenience eh mga dati ng walang drounding, sa tingin ko pwede. basta ang gfci naka ground.

    • @TonyBangayan-cp5uj
      @TonyBangayan-cp5uj Год назад +1

      Salamat I dol

    • @galawangelectrical
      @galawangelectrical  Год назад

      @@TonyBangayan-cp5uj walang anuman lods

  • @johndelacruz9837
    @johndelacruz9837 Год назад +1

    Pwede pala kahit walang ground?

    • @galawangelectrical
      @galawangelectrical  Год назад

      sa magiging load ng GFCI pwede wala. ang gfci ang dapat naka ground.

  • @jesusbalaba2456
    @jesusbalaba2456 Год назад +1

    Ilang outlets sa Isang GFCIpwede

    • @galawangelectrical
      @galawangelectrical  Год назад

      kung sa ordinary na laki ng bahay lods, mallapit lang naman yan. kahit 5 ok yan. ang mga gfci lods, mas ok gamitin yan sa mga lugar na malapit sa may tubig lods. jan effective yung gfci.

  • @kimbaroquillo975
    @kimbaroquillo975 5 месяцев назад

    Ilan co ang pwede i connect sa gfci boss?

    • @galawangelectrical
      @galawangelectrical  5 месяцев назад

      depende lods, ang gfci ai mas recommended yan sa may frecence ng tubig, toilet kitchen outside. pwede mo ikarga lahat ng conviniece outlet mo jan, yun nga lang apektado sila lahat pag nag karuon ng problem, kaya sa mga piling outlet lang mas ok na mapalagay yan.

  • @didingandamygonzgamixedvlo3959
    @didingandamygonzgamixedvlo3959 3 года назад +1

    👍👍👌👌👏👏👏

  • @ulupongz5229
    @ulupongz5229 Год назад +1

    May fb ka ba? Pa assist naman sir 😊

    • @galawangelectrical
      @galawangelectrical  Год назад +1

      meron lods, the same account name ang channel ko sa fb page. check mo yung knowleys sa fb page

  • @herouzzaltv5465
    @herouzzaltv5465 3 года назад +2

    নাইচ ভাই

  • @oseng0010
    @oseng0010 2 года назад +1

    Walang grounding?

    • @galawangelectrical
      @galawangelectrical  2 года назад

      yes lods yung mga outlet sa bahay na walang grounding, para sa load ng GFCI, pero dapat lagyan ang GFCI lods, kahit isa lang sya lang ang meron.

  • @fernandoalejandro8234
    @fernandoalejandro8234 3 месяца назад

    Sir tanong lang po magkano GFCI?

    • @galawangelectrical
      @galawangelectrical  3 месяца назад

      mejo mahal gfci na outlet lods, yung nabili q ai 1k+ siguro yung iba baba gang 900 or gang 800 depende sa brand. mga ganyan presyuhan nyan.

    • @fernandoalejandro8234
      @fernandoalejandro8234 3 месяца назад +1

      @@galawangelectrical sir alin ga magandang transformer ga tawag dun O GFCI? salamat sa sagot. Bumili kc Ako Ng ref. Sabi Nung salesman di pwede yon akin extension maliit , bumili Ako Ng wire #10 at plug ikakabit Kona sana, e napanood ko blog mo na kailangan sa mga appliances GFCI.

    • @galawangelectrical
      @galawangelectrical  3 месяца назад

      @@fernandoalejandro8234 ang laki naman ng wire mo lodi, #12 lang ok na sa ref. ang ref di na need ng GFCI lodi. ang gfci nillagyan lang dun sa mga outlet na malalapit sa water like lababo o sa labas ng bahay o sa banyo. di na kelanga i gfci yan lods.

  • @drock276
    @drock276 4 месяца назад

    Maybe I don't understand all Tagalog but the gfci won't work as designed if not grounded. If there is a surge the outlet will not be able to ground. Never install if you don't have hot, neutrol and ground wires.

    • @galawangelectrical
      @galawangelectrical  4 месяца назад +1

      but in NEC you can replace an receptacle that has no grounding, with gfi outlets. stated that you will mark up it, ungrounded.

  • @jared3396
    @jared3396 8 месяцев назад

    parang wala nmn difference ung old outlet n nkakabit sa gfci kung magsisilbing breaker cya. Ang old outlet kung nagkaron ng problema dba magtrip ung breaker? Ang main reason nmn kaya may gfci e pra maiwasan danger ng may malikot n bata magpasok ng bagay sa outlet. Hndi nmn naiwasan ng pagkabit sa gfci ng old outlets kc wla sila nung safety features n d maipsok ang isa bagay pag hndi dlawa on tatlo prong na maipasok

    • @galawangelectrical
      @galawangelectrical  8 месяцев назад

      kung parehas sila ng function dina gagawa ng GFCI lodi. mag ka iba ang function ng GFCI sa ordinary breaker. sa ordinary breaker need pa nya ma abot yung limit nya na talagang baka ikapahamak mo kung tao ang makakahawak ng fault, pero ang GFCI mas ginawa nilang mas safe ito sa tao na makakahawak ng fault. sa pag kaka alam ko .003A ai mag trip na ang GFCI sa ground fault lodi. ang mga FGCI ai mas kelangan gamitin sa mga matubig na location. yan ang dapat pinag lalagyan nyan. for safety nga. yung sa butas ng prong, may nabibili na meron may na bibili na wala lods. tamfer resistance at non tamfer.