Daikin | How to rectify error code JA

Поделиться
HTML-код
  • Опубликовано: 16 июл 2024
  • Brand : Daikin (Super inverter)
    Model : RZQ-125PV4A
    Error : JA
    Method of Malfunction Detection ;
    Malfunction is detected from the pressure detected by the high pressure sensor.
    Malfunction Decision Conditions ;
    When the high pressure sensor short circuit or open circuit
    Supposed Cause ;
    1) Detect of high pressure sensor.
    2) Connection of liw pressure sensor with wrong connection.
    3)Detect of outdoor unit PCB
    #Daikin #VRV #bonmj

Комментарии • 70

  • @uyexdu4646
    @uyexdu4646 2 года назад +2

    Thank you for sharing your skills sir, I am also hvac technician maintenance but i am not more knowledgeable of electronic split unit... I've been there in Singapore very nice place and very good people . I hope i can find work there...

    • @BonMj
      @BonMj  2 года назад +1

      Thanks

  • @TheBL1tZKrieG
    @TheBL1tZKrieG 2 года назад +2

    Thankyou for the video! I was looking to replace this sensor and I wasn't sure if it needed to be pumped down or not, glad to see there is a stop valve in the stem.

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @laworder6092
    @laworder6092 2 года назад +2

    Hi Bon Mj
    Thanks for sharing your real world troubleshooting.

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @UmarTeknikOfficial
    @UmarTeknikOfficial 2 года назад

    Sangant bermanfaat bosqu..

  • @mdsaifmdsaif3328
    @mdsaifmdsaif3328 2 года назад +1

    You are a good man and also a good engineer😂👌❤️

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @Official_ranjeet_763
    @Official_ranjeet_763 Год назад +1

    I like your work full care and understanding good
    Keep up the good work sir

  • @osmarradansantos8483
    @osmarradansantos8483 2 года назад +2

    Hello Mr thanks for you information,,,, excelente!!!!👍🏻

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @karimchiu7527
    @karimchiu7527 Год назад +1

    Thanks Sir Bon

  • @Steven-vy7en
    @Steven-vy7en Год назад +1

    Tq for sharing the video Mr Bon🙏🙏🙏

  • @maracservices
    @maracservices 2 года назад +1

    Love it 👍🏻

    • @BonMj
      @BonMj  2 года назад

      Thanks bro

  • @airconditionertech7178
    @airconditionertech7178 2 года назад

    Thanks for sharing video

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @airconditionertech7178
    @airconditionertech7178 2 года назад

    Super sir

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @mehedihasanasheek2518
    @mehedihasanasheek2518 2 года назад +1

    ❤❤❤

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @user-ck8lb6dt3q
    @user-ck8lb6dt3q 2 года назад +1

    Hi Bon, thanks for sharing, could you please let us know what website you are using for explaining the error code?

  • @learnmore2301
    @learnmore2301 2 года назад +1

    👍

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @msaeed589
    @msaeed589 2 года назад +1

    Hi bon I need ask about a dressing of indoor unit in new commissioned Fujitsu vrf

  • @janshaw5472
    @janshaw5472 2 года назад

    老师,pressure sensor 只有大机器才有是吧!

  • @amilawijedasa
    @amilawijedasa Год назад +1

    Great video. Do you know where I can buy this spare part? Online.

    • @BonMj
      @BonMj  Год назад

      Only Daikin

  • @tamilmelodylovers...5108
    @tamilmelodylovers...5108 3 месяца назад +1

    Sir this type no need to keep gas for open the HPS?

    • @BonMj
      @BonMj  3 месяца назад

      Yes

  • @karaors8970
    @karaors8970 2 года назад +1

    +1

    • @BonMj
      @BonMj  2 года назад +1

      Thanks

  • @aungpyaephyo-bn7bz
    @aungpyaephyo-bn7bz 3 месяца назад +1

    Hello sir, please let me know, what's the E4 error for VRV3-S ceiling suspended unit.

    • @BonMj
      @BonMj  3 месяца назад

      Check gas pressure or low pressure switch

  • @ARSHADkHAN-sd8zb
    @ARSHADkHAN-sd8zb 2 года назад

    Hii Sir

  • @ARSHADkHAN-sd8zb
    @ARSHADkHAN-sd8zb 2 года назад

    Can u tell me model number I think saudi Arabia not available this model

  • @kywong6213
    @kywong6213 2 года назад +1

    would you mind to tell me how many times that you press reset button to reset the system ,Thank you

    • @BonMj
      @BonMj  2 года назад

      By Dsikin Press more than 5second.
      We sometimes will press more after the 5second

  • @BangYudie88
    @BangYudie88 2 года назад +1

    Mister help answer and question,,am technician air conditioner,,Mister is the same problem with error codes J1 and JA and their fixes

    • @BonMj
      @BonMj  2 года назад

      Similar.

    • @BangYudie88
      @BangYudie88 2 года назад +1

      @@BonMj oke,,Thanks Mister 🙏

    • @BonMj
      @BonMj  2 года назад

      @@BangYudie88 welcome

  • @rajputnitesh3123
    @rajputnitesh3123 Год назад +1

    Rxmq6tv6 .....U2 error code show compressor . invter cierict bord replace but U2 not solved what is problem

    • @BonMj
      @BonMj  Год назад

      Voltage , fan motor, fan pcb

  • @albonceasar5770
    @albonceasar5770 Год назад +1

    L1 error boss,floor mounted?

    • @BonMj
      @BonMj  Год назад

      Outdoor fan motor
      Inverter pcb

  • @viewofnature3375
    @viewofnature3375 2 года назад +1

    Hi, Bon.Fujitsu vrf error code 9U. pls help me

    • @BonMj
      @BonMj  2 года назад +1

      Outdoor unit miscellaneous error,try reset

    • @viewofnature3375
      @viewofnature3375 2 года назад +1

      @@BonMj thank you

    • @BonMj
      @BonMj  2 года назад

      @@viewofnature3375 👍

  • @fatkee2152
    @fatkee2152 2 года назад +1

    Please let me know the outdoor unit Model no?

    • @BonMj
      @BonMj  2 года назад

      Check the description

    • @fatkee2152
      @fatkee2152 2 года назад +1

      Do the low pressure sensor have the resistance when good?

    • @BonMj
      @BonMj  2 года назад

      @@fatkee2152 yes

    • @fatkee2152
      @fatkee2152 2 года назад +1

      Thank your video

  • @ffsurajityt7313
    @ffsurajityt7313 2 года назад +1

    Sir help me Daikin vrv 4 E9 error code

    • @BonMj
      @BonMj  2 года назад

      Check Y1E ~ Y7E outdoor LEV

    • @ffsurajityt7313
      @ffsurajityt7313 2 года назад

      Chaking 2 eev

    • @ffsurajityt7313
      @ffsurajityt7313 2 года назад

      Machine power just supply ,led show E9

    • @BonMj
      @BonMj  2 года назад

      @@ffsurajityt7313 measure EEV coil reading

    • @ffsurajityt7313
      @ffsurajityt7313 2 года назад +1

      48 k ohm

  • @abdallamouktar3086
    @abdallamouktar3086 Год назад +1

    Nice 👍👍 ihave some problem in daikin mashin can call you phone Whatsapp

  • @hafeezdaikin2517
    @hafeezdaikin2517 2 года назад +1

    👍

    • @BonMj
      @BonMj  2 года назад

      Thanks