Sir bon can you enligthened me about the earth leakage detection? im having same trouble with what you are vlogging right now E2. i just don't understand why i can't change the mode of wired remote from fan mode to cool mode is it in lock mode?
I've experience trouble error E2-01 VRV 4 model RXQ14TY14 base on manual is earth leakage sencor detected, so how to solve problem like this? Is that same problem VRV 3 ? Thank's
Hai sir .i need your help.can you tell me vrv 4 indoor model number FXMQ 63PAVE (indoor pcb model number 4018526).i replaced indoor pcb board.aftrer replaceing (AJ) alarm coming..can you tell me how to set adaptor setting 🙏🙏🙏
@@BonMj .they sended only pcb.they not sended bypass wire.thats why i 'm try repair bypass wire.because i dont have this by pass wire resistance .do you have any idea this wire resistance ????
@@vedatkulli6296 if the indoor to outdoor connection cable is on, one can turn on, but if both indoor cables are combined there will be an error, one must turn on and there will be no error
Te sigo de argentina, estoy trabajando con vrv y gracias por todos estos aportes
I am from India, your video very good, one by one word came understanding.
Thanks
How to check earth leakage? Same E2 error but high pressure sensor is good
I know there is a wire that goes to ground with a resister. It that resister fails it’ll turn on the red light on the HPS board.
Love your video bro it’s so great and the way you explaining it’s awesome please keep continue
Thanks
@@BonMj yes i agree with him you help fix my aircon
@@joellannevlogs Thanks
How do you know what the Ohms on the HPS suppose to be to determine if they are good or not?
Hi bon, can you make a video how to check between outdoor pcb and indoor pcb not communicating, and know which pcb is faulty thanks
Sir please show me how to commission the vrv 4.your videos help us to improve more.thanks
Very good job your NO1
ok.thank for this sir. i am follow you.
Sir, how you resset error codes it's manually or just power shut
Great video, thank you! Once the new sensor is in, how do you change the board settings back?
always wanted to know this question
Thanks for your new update video sir
Thanks
thank you i have this error code you fixed well dkne love the videos 👍
Thanks
Good information
Thanks
Thank you Sir
,👍good job! Thank you
Super 🔥🔥🔥🔥
If bypass the Master CDU, Standard 1&2 compressor working or not. and then after we repair the error, how to set the normal condition. Thank you bon.
By pass master cu is whole cu not working.
Sir bon can you enligthened me about the earth leakage detection?
im having same trouble with what you are vlogging right now E2.
i just don't understand why i can't change the mode of wired remote from fan mode to cool mode
is it in lock mode?
E2 please check high pressure sensor coil reading.
nice job bro 👍👍👍👍
Thanks
NOTE: Daikin doesn't recommend you code out condensers for more than 10 days. Too much stress on the other condensers.
Thanks
why still set the settings to 18 ? the system is under capacity , i think its bad for the sytem
Indoor only 50%running.
Hello sir, Do you know how much is VRV 3 noise PCB board?
I not sure.sorry
What is the purpose of use by pass master unit please explain sir
So he can have the slave units working
Emergency setting means any compressor and sensors,high pressure switch faulty ,may i do this same setting sir please reply me
Can.if multi outdoor unit
@@BonMj what is mean by by pass ? Temporarily not function the unit right sir
@@peramaraj2763 yes
E202 alaram Daikin VRV4 please help me what is problem.
Outdoor single ho to setting kya hogi sir
Set what?
Hi bon
If red and black 90k ohm
Red and White 45k ohm
Black and White 1.5k ohm
Is this faulty?
Red and white is M ohm.
This coil reading abnormal
I've experience trouble error E2-01 VRV 4 model RXQ14TY14 base on manual is earth leakage sencor detected, so how to solve problem like this? Is that same problem VRV 3 ? Thank's
Check high pressure sensor reading or may be compressor
Error code E2-02what happen bro
May be same problem.
E2-02 is outdoor slave 1 CU
My experience is master inv.compressor no.2 for E2-02, earth leakage sensor detected.
圧力センサー
Please guide E2 error on VRV4 daikin
Check high pressure sensor or gas pressure
How about error a5 daikin
Try check the indoor drain pump and float switch
Hai sir .i need your help.can you tell me vrv 4 indoor model number FXMQ 63PAVE (indoor pcb model number 4018526).i replaced indoor pcb board.aftrer replaceing (AJ) alarm coming..can you tell me how to set adaptor setting 🙏🙏🙏
Check indoor pcb X23A the by pass clip.
Clip the by pass wire.
The wire come with new pcb
@@BonMj .they sended only pcb.they not sended bypass wire.thats why i 'm try repair bypass wire.because i dont have this by pass wire resistance .do you have any idea this wire resistance ????
@@tharindumadushan477 just a looping wire
AC technician VRV E3 error code
Check gas pressure
ok boss
Hi sir how are you
I m good.thanks
Request Error U4
Communication error check wiring conections most likely you need to power cycle the unit if
@@vedatkulli6296 if the indoor to outdoor connection cable is on, one can turn on, but if both indoor cables are combined there will be an error, one must turn on and there will be no error