  • Learn how to service your Everchill 10.7 CU FT Refrigerator when there appears to be no power to the fridge. Learn how to check power in the back of your 10.7 cu ft Everchill. See our full Everchill collection at www.wayinterglobal.com/collec...
  • ХоббиХобби

Комментарии • 40

  • @seymourscagnetti1413
    @seymourscagnetti1413 Год назад +1

    Super easy hack/fix for the Everchill 12 volt units. Buy the Haier 9.8 cf. 120 volt A/C fridge. Same exact box, but only in a more reliable 120 volt A/C configuration. Hope this helps.

    • @MrKnscarbrough
      @MrKnscarbrough 2 месяца назад

      How much ventilation would a 120v fridge need?

  • @albertberumen3500
    @albertberumen3500 2 года назад

    This video helped me find out that my compressor board had a fault. Found burn marks on connection to compressor. Thanks for your help!

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад +1

      @Albert, sounds like you were able to self-identify some issues. Please contact our team if you need any more help - customerservice@wayinterglobal.com

    • @kim8839
      @kim8839 2 года назад

      Albert, was the compressor board Bad? I too have burn marks on connection to compressor.

    • @albertberumen3500
      @albertberumen3500 2 года назад

      @@kim8839 Yes it was .You can buy one online or request one from the manufacturer. I emailed them and got one shipped to me at no cost .

    • @albertberumen3500
      @albertberumen3500 2 года назад

      @@kim8839 make sure the replacement has the exact model number.

    • @kim8839
      @kim8839 2 года назад

      @@albertberumen3500 Thanks for the quick reply, at least I know I'm on the right track.

  • @bygodsgrace7793
    @bygodsgrace7793 2 года назад

    You have any of these extra parts layn around you wanna get rid of ?? ..
    Terminal block ?
    Main circuit board ?
    Thanks !

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello - Please reach out to customerservice@wayinterglobal.com or call (574) 971 4490 for parts requests.

  • @TDC_Dragon
    @TDC_Dragon 2 года назад +1

    I have the Everchill 12 volt 10.7 cubic foot that I bought recently. It is wired to a 15 amp fuse in the RV with 10 AWG and grounded to frame with 10 AWG. The refrigerator will run and cool perfectly for a day or two and then stops cooling and returns to ambient temperature but the interior lights look normal or sometimes flash. I have replaced the compressor board. If I remove the 15 amp fuse for a couple hours and replace it will start up again and run another day or two before again returning to ambient temperature. I'm at a loss on what to do.

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hi Mitch - We would love to assist you with this issue. Please reach out to customerservice@wayinterglobal.com or call (574) 971 4490 so we can assist you.

    • @paulmello7642
      @paulmello7642 2 года назад

      I have the exact same issue. Did you find a solution? Thank you

    • @JorgeGonzalez-wy2vz
      @JorgeGonzalez-wy2vz 2 года назад

      @@wayinterglobal7898

  • @Northerncannabis
    @Northerncannabis 2 года назад

    Hello. Really struggling with my new fridge that came in my rv. Everchill 12v. It doesn’t cool st all. Already opened a warranty claim and got a new compressor board. But it didn’t fix the issue. The compressor still makes a clicking sound every 2-3 minutes. Any help is really appreciated as this is a pain for our first camping season in our camper

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello Paul - please contact us at warrantyclaims@wayinterglobal.com or call 574-971-4490 to speak to warranty. Thank you!

  • @dannymitchell4033
    @dannymitchell4033 Год назад

    the fan in my everchill WD282 goes on and off every 5 seconds-----WHY

  • @marcmihelich971
    @marcmihelich971 2 года назад

    I feel like the compressor on my 10.7 is getting louder, it's been used Maybe 15 weekend in 4 years. Are there any services issues that could cause this? Or are these things just junk?

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello Marc - There are no service issues that can cause this type of issue. Is the unit level?

  • @JorgeGonzalez-wy2vz
    @JorgeGonzalez-wy2vz 2 года назад

    Hello - I am curious- I am following all you have said and I have voltage everywhere you stated I need to have it - did you say that I need to ground out the bottom terminal (T terminal) which is showing 4.78 volts, I believe I stating this by memory. What is my expected result if I should ground the bottom terminal?

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello Jorge - if you ground the bottom terminal, The compressor should start up and run.

    • @JorgeGonzalez-wy2vz
      @JorgeGonzalez-wy2vz 2 года назад

      @@wayinterglobal7898 thank you for the response - if it starts, that will confirm the compressor board has failed? Also should the red and white wires stay disconnected?

    • @JorgeGonzalez-wy2vz
      @JorgeGonzalez-wy2vz 2 года назад

      Hello, I purchased the compressor board from your company and it arrived. I installed the board and my compressor still doesn’t start. Anything else I should check?? Any assistance with this would be greatly appreciated.
      Thank you,
      Jorge

  • @Noneya1775
    @Noneya1775 Год назад

    Can you tell us how to check the compressor itself? I know there should be a certain number of ohms between each of the three pins….

    • @wayinterglobal7898
      @wayinterglobal7898  Год назад

      Hello - With the compressor board attached remove the bottom wire from the T terminal and attach a jumper wire to the terminal and then to ground to see if the compressor starts. The resistance between each pin on the compressor itself is .5-.6 ohms.

  • @realgagne2956
    @realgagne2956 2 года назад

    My 2019 Everchill 10.7 freezer fan stopped working, thus the coil freeze up all the time. Where can I get that part for model WD-282FWDC

    • @realgagne2956
      @realgagne2956 2 года назад

      Not knowing what the ohms is suppose to be on the motor, but it reads 5.17. In the tiny box at the back inside the freezer where I had to unplug the harness that's about 1/4 inch with 3 pins inside, it wasn't easy to put 2 alligator clips, but it surely didn't read 12 V DC. In this camper it won't be easy to get the fridge out of it's cubby hole that's 2 ft. off the ground. You're saying "board", do you mean control board, cause there's suppose to be 2 boards in here.

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello - For available parts, please reach out to directpurchase@wayinterglobal.com.

    • @realgagne2956
      @realgagne2956 2 года назад

      @@wayinterglobal7898 I called them, and it looks like it's going to take about 1 month to get the parts I need. You would think there's other places to get these parts faster.

  • @terryhosey7098
    @terryhosey7098 2 года назад

    My everchill refrigerator ran good for 22 months and now you can here the fan running but it won't cool down and intermittently the light will flash. Can you tell me a fix for this?

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello Terry - It could be an issue with your compressor board. For help with this, please contact customerservice@wayinterglobal.com or call (574) 971-4490. Thank you!

  • @dotanswisa1442
    @dotanswisa1442 2 года назад

    Where can I order new compressor board?

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello - For available parts, please reach out to directpurchase@wayinterglobal.com.

  • @loganprange
    @loganprange 2 года назад

    My fridge worked great for about 3 months but stopped cooling. I pulled it from the wall today and ran all power tests in the video. I have one volt on the P terminal and 5 volts on the T terminal. My fridge is on a level surface. The fan still blows but my compressor will not run. Please help!

    • @wayinterglobal7898
      @wayinterglobal7898  2 года назад

      Hello Logan - We are sorry to hear about your issues with your Everchill model. Please contact our warranty department at 1-574-971-4490 and they can assist in troubleshooting. Thank you!

    • @justinjones5794
      @justinjones5794 2 года назад

      Seems every person I know, myself included, have problems with these fridges. Customer service is terrible and they clearly know they have a problem with their product.

    • @JorgeGonzalez-wy2vz
      @JorgeGonzalez-wy2vz 2 года назад

      @@wayinterglobal7898

    • @JorgeGonzalez-wy2vz
      @JorgeGonzalez-wy2vz 2 года назад

      @@wayinterglobal7898