How to find a number of bars in column | column'ல் எத்தனை கம்பி போடுவது என்று கண்டுபிடிப்பது எப்படி?

Поделиться
HTML-код
  • Опубликовано: 27 авг 2024

Комментарии • 80

  • @varunkarthik6024
    @varunkarthik6024 17 дней назад

    Arivu kanna Theranthudenga ivloooo Yelimaiya ...Thank you brother keep Teaching always...na ungala en master ah select panniten 😅♥️🙌🙌🫂🔥🔥🔥🔥🔥

  • @nottoday9014
    @nottoday9014 Год назад +7

    Vera level la teach panringa sir.ivlo naal unga videos lam RUclips la recommend eh pannala

  • @bharathrambabu
    @bharathrambabu Год назад +1

    Supera solli kuduthinga gurunatha nee valga

  • @subramaniyanshanmugam6186
    @subramaniyanshanmugam6186 2 месяца назад

    Thanks bro hru 🎉❤ kovilpatti garpender❤

  • @vigneshbalaji591
    @vigneshbalaji591 Год назад +1

    Good explanation bro..oru building manual ah structural design panni podunga bro

  • @sharanr1569
    @sharanr1569 5 месяцев назад

    💆‍♀️finally i got your videos

  • @rathishb4849
    @rathishb4849 Год назад +1

    Bro....Elevation low budget la super ah irukanum athuku ethuna tips video podunga

  • @fgasathish288
    @fgasathish288 Год назад +2

    Andha load calculation pathiyum podunga bro .........detail ah explain panni

  • @samvignesh620
    @samvignesh620 7 месяцев назад

    Super explain bro thank you so much

  • @ashoksethupathy2189
    @ashoksethupathy2189 Год назад +4

    Kindly do videos related to rebar drawings, like how to draw rebar in pile cap, pier, etc

    • @civilonlycivil
      @civilonlycivil  Год назад +1

      Sure we will discuss about pile and pile cap soon☺

  • @dhileepan8706
    @dhileepan8706 Год назад +2

    Super bro
    Load calculation podunka

  • @KumaranMuthaiya
    @KumaranMuthaiya Год назад +1

    Clg la kuda ipdi explain pannala. 👏👏👏

  • @ashoksethupathy2189
    @ashoksethupathy2189 Год назад +1

    Great brother

  • @ramaaravinth004
    @ramaaravinth004 Год назад

    spr bro very useful keep posting these kind of quality contents

  • @mohana3983
    @mohana3983 9 месяцев назад

    நன்றி தம்பி

  • @SamuvelK
    @SamuvelK Год назад +1

    Centre line method estimate video podunga bro

  • @sendilpadu5072
    @sendilpadu5072 Год назад +1

    Very very useful vedio sir thanks how we can find the loud in the colum

  • @learncivilengineering2927
    @learncivilengineering2927 Год назад +2

    bro estimation series video podunga bro neraiya bbs laam pathi solli kudunga bro

  • @fgasathish288
    @fgasathish288 Год назад +1

    Bro super bro

  • @rameshmmr4848
    @rameshmmr4848 Год назад +1

    Bro 800kn load eppudi one column ku varuthunu oru video podunga bro

  • @laadulabakkudossmemes1360
    @laadulabakkudossmemes1360 Год назад +1

    Roof concrete podrathu...Ready mix concrete(RMC) best'ah illa Hand mix concrete best'ah. Which is economical??? Video podunga bro...its usefull to everyone

    • @civilonlycivil
      @civilonlycivil  Год назад

      Sure 🥰🥰

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Год назад

      Bro both cost will be similar only 5k difference will come. Manual mixing is best from my view

  • @nisha536
    @nisha536 Год назад +1

    Structural drawing epdi podanum nu A to Z fulla solli kuduga anna

  • @Keerthi-nt2ko
    @Keerthi-nt2ko Год назад

    Bro same steel design beam ku oru video podunga bro

  • @PradeepPradeeppitchai-xd9sh
    @PradeepPradeeppitchai-xd9sh 11 месяцев назад

    Tq you bro.

  • @risvanahamed9113
    @risvanahamed9113 10 месяцев назад

    Oru slab oda dead load yeppudy calculate pandrathu athuku column yeppudy Design pandrathu

  • @nagendranradhakrishnan4764
    @nagendranradhakrishnan4764 Год назад

    Storage of building roll in column pl explain.

  • @Manidhan-om2ih
    @Manidhan-om2ih Год назад +1

    Bro 6* 9* inches column podalamnu sollirukanga appadi podalama illa 6* 12 podalama 6 rod sollirukanga (4x12mm 2x10mm )
    Hollow bricks la katturom

    • @civilonlycivil
      @civilonlycivil  Год назад

      Illa, puriyala..

    • @Manidhan-om2ih
      @Manidhan-om2ih Год назад

      1/2 * 3/4 size column podalamnu mester solluranga appadi podala illa 3/4 * 1 feet podalama column la 4*12mm rod 2*10mm rod podalamnu sollirukanga

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Год назад

      @@Manidhan-om2ih minimum column size 9"x 9" ithuku keela poga kudathu.

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Год назад

      @@Manidhan-om2ih athey maari column ku minimum vertical bar 12mm provide pananum.

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Год назад

      @@Manidhan-om2ih Mullion ku matum 10mm use panalam athu wall length 3m ku mela pogum pothu Mulion provide panuvanga. Athu column illa but appdi act aagum for additional support.

  • @vijaycivil3987
    @vijaycivil3987 Год назад

    Super teach

  • @manikandanmani-zb1tl
    @manikandanmani-zb1tl Год назад +3

    ப்ரோ , காலத்தில் stirrups கொடுக்கும்போது நடுப்பகுதியில் அதிகமான spacing,கீழ் மற்றும் மேல் பகுதியில் குறைவான spacing ஏன் கொடுக்கிறார்கள்

    • @civilonlycivil
      @civilonlycivil  Год назад +3

      Shear force supports la adhingavum, mid space la kammiyavum irrukum so apdi tharanga..

    • @manikandanmani-zb1tl
      @manikandanmani-zb1tl Год назад

      Ok bro, அந்த stirrups இடைவெளியை எவ்வாறு கணக்கிடுவது?

    • @civilonlycivil
      @civilonlycivil  Год назад +1

      13:06

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Год назад +1

      @@manikandanmani-zb1tl roof height la irrunthu l/4 split pannikonga antha length ku mattum stirrups spacing 100mm maintain panunga both floor and roof L/4 la balance area la stirrups spacing maximum aa irukalam but not exceeding 200mm.

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Год назад +1

      Example floor to roof height 3m
      3/4 is 0.75metre
      So floor bottom to 0.75metre ku close spacing of stirrups provide pannanum.
      Same roof side also.

  • @Ravismadurai
    @Ravismadurai Год назад

    Bro chat gpt la intha answer varuthu bro kongam clarification Pannu ga bro
    Steel reinforcement for column
    
    Calculate the diameter and number of steel reinforcement required for a column size 230 × 300mm carrying an ultimate axial load 800 kN and the great of the concrete is m20 and Fe550d
    To calculate the diameter and number of steel reinforcement required for the given column size and load, we need to perform the following steps:
    Step 1: Calculate the cross-sectional area of the column.
    The cross-sectional area of the column can be calculated as follows:
    Area = Width x Depth Area = 230 mm x 300 mm Area = 69,000 mm²
    Step 2: Determine the compressive strength of the concrete.
    The grade of concrete given is M20. According to the IS 456:2000, the characteristic compressive strength of M20 grade concrete is 20 N/mm².
    Step 3: Determine the yield strength of the steel reinforcement.
    The grade of steel reinforcement given is Fe550d. According to the IS 1786:2008, the characteristic yield strength of Fe550d grade steel reinforcement is 550 N/mm².
    Step 4: Calculate the area of steel required to resist the given axial load.
    The area of steel required to resist the given axial load can be calculated using the following formula:
    Ast = (Pu x 1000)/(0.87 x fy)
    Where,
    Ast = Area of steel required (mm²) Pu = Ultimate axial load (kN) fy = Characteristic yield strength of steel reinforcement (N/mm²)
    Plugging in the values, we get:
    Ast = (800 x 1000)/(0.87 x 550) Ast = 1687.29 mm²
    Step 5: Calculate the diameter and number of steel bars required.
    Assuming that we will use only one steel bar, we can calculate the diameter of the steel bar required as follows:
    Area of one steel bar = (π/4) x d²
    where d is the diameter of the steel bar.
    Plugging in the values, we get:
    Area of one steel bar = (π/4) x d² 1687.29 = (π/4) x d² d² = (4 x 1687.29)/π d² = 2151.05 d = 46.37 mm (approx.)
    Therefore, we can use a steel bar with a diameter of 46 mm.
    Now, we can calculate the number of such steel bars required as follows:
    Number of steel bars = Ast/Area of one steel bar
    Plugging in the values, we get:
    Number of steel bars = 1687.29/((π/4) x 46²) Number of steel bars = 3.52
    Since we cannot use fractional steel bars, we need to use 4 numbers of steel bars.
    Therefore, the diameter of steel reinforcement required for the given column size and load is 46 mm and the number of steel bars required is 4.
    
    Calculate the 12mm diameter and number of steel reinforcement required for a column size 230 × 300mm carrying an ultimate axial load 800 kN and the great of the concrete is m20 and Fe550Sd
    2 / 3
    To calculate the number of 12mm diameter steel reinforcement required for the given column size and load, we need to perform the following steps:
    Step 1: Calculate the cross-sectional area of the column.
    The cross-sectional area of the column can be calculated as follows:
    Area = Width x Depth Area = 230 mm x 300 mm Area = 69,000 mm²
    Step 2: Determine the compressive strength of the concrete.
    The grade of concrete given is M20. According to the IS 456:2000, the characteristic compressive strength of M20 grade concrete is 20 N/mm².
    Step 3: Determine the yield strength of the steel reinforcement.
    The grade of steel reinforcement given is Fe550Sd. According to the IS 1786:2008, the characteristic yield strength of Fe550Sd grade steel reinforcement is 550 N/mm².
    Step 4: Calculate the area of steel required to resist the given axial load.
    The area of steel required to resist the given axial load can be calculated using the following formula:
    Ast = (Pu x 1000)/(0.87 x fy)
    Where,
    Ast = Area of steel required (mm²) Pu = Ultimate axial load (kN) fy = Characteristic yield strength of steel reinforcement (N/mm²)
    Plugging in the values, we get:
    Ast = (800 x 1000)/(0.87 x 550) Ast = 1687.29 mm²
    Step 5: Calculate the number of 12mm diameter steel bars required.
    We can calculate the area of one 12mm diameter steel bar as follows:
    Area of one 12mm diameter steel bar = (π/4) x d² Area of one 12mm diameter steel bar = (π/4) x 12² Area of one 12mm diameter steel bar = 113.1 mm²
    Now, we can calculate the number of 12mm diameter steel bars required as follows:
    Number of 12mm diameter steel bars = Ast/Area of one 12mm diameter steel bar
    Plugging in the values, we get:
    Number of 12mm diameter steel bars = 1687.29/113.1 Number of 12mm diameter steel bars = 14.92
    Since we cannot use fractional steel bars, we need to use 15 numbers of 12mm diameter steel bars.
    Therefore, the number of 12mm diameter steel reinforcement required for the given column size and load is 15.

    • @civilonlycivil
      @civilonlycivil  Год назад +1

      in video what did i explain sample the AI Repeats.
      1. The load acting on the column,
      2.Area of column
      you will get ast.
      with the help of ast
      3. area of bar using.
      proved the bar as per ast requirement

  • @rockyrajesh317
    @rockyrajesh317 Год назад

    Bro complete structural design for residential building notes...pdf..book .... Ethachu iruka bro..?

  • @saravananbe1830
    @saravananbe1830 Год назад

    Super bro
    Footing design videos podunga

  • @spmanicivil001
    @spmanicivil001 Год назад

    How to calculate p value

  • @ramasamyv7697
    @ramasamyv7697 Год назад

    Bro main rod ahh column la entha direction la kudukanumnu sollunga bro..
    Example ahh ippo oru 1x.75 post kku 6number of 12 mm kudukuromna atha 0.75 pakkam kudukanuma illa.... 1 pakkam 3 rod kudukanuma sollunga bro... Plz

    • @civilonlycivil
      @civilonlycivil  Год назад +1

      Perpendicular to Longer span (unsupported length). 4 side la entha side la support oda distance adhigamo athuku perpendicular ah Rebar vara mathiri pathukalam.

    • @ramasamyv7697
      @ramasamyv7697 Год назад

      Bro atha pathiyum detailahh video podunga bro....

    • @civilonlycivil
      @civilonlycivil  Год назад

      @@ramasamyv7697 sure sure

    • @ramasamyv7697
      @ramasamyv7697 Год назад

      @@civilonlycivil thank u bro

  • @Thamaraiselvan-jm2ze
    @Thamaraiselvan-jm2ze Год назад

    Do more videos

  • @dhanushkodi7861
    @dhanushkodi7861 6 месяцев назад

    Bro 12"×9" column la 15 feet distance vidalama..?

  • @manigandan2016
    @manigandan2016 Год назад

    Bro job vacancy eruntha solunga

  • @shalomp1861
    @shalomp1861 Год назад

    One KN என்பது எத்தனை கிலோ

  • @yasaramanisha6285
    @yasaramanisha6285 Год назад

    Spacing for beam also same method bro????

    • @civilonlycivil
      @civilonlycivil  Год назад

      column ly spacing kandupudika innum silla methods irruku heavy structures vera mathiri dhan spacing provide pannanum.

  • @ramasamyv7697
    @ramasamyv7697 Год назад

    Ninga use pannirukka formula axial loaded column kku mattum than use akuma

    • @civilonlycivil
      @civilonlycivil  Год назад +1

      Apdi illa, ella column ku ore formula dhan, but corner illa side la vara column ku unga load la irrunthu some % of the amount load increase pannaum.
      4 corner column mella vara load kooda, athanodala irrunthu 15 to 20 % load oda add panikanum , side la vara column ku mella vara load kooda athanoda load la irrunthu 11 to 15% ungaloda load kooda add panni kanum. Then atha P (load) ah unga formula la use pannanum.

    • @vigneshbalaji591
      @vigneshbalaji591 Год назад +1

      @@civilonlycivil bro center la vara columnku thana load athikam varum corner la irukara columnku kammiyathana varum?

    • @civilonlycivil
      @civilonlycivil  Год назад +1

      @@vigneshbalaji591 most of the case la apdi la dhan, but water tank la vara apo corner column hum athigamana load ah handle panna vendi irrukum. Corner column ku moment aagra thamai athigama irrukum adhanala antha load oda antha percentage of loads ah addition pannanrom.

    • @vigneshbalaji591
      @vigneshbalaji591 Год назад +1

      @@civilonlycivil nice explanation bro .. detailing ungala maari solla mudiyaathu..oru building manual ah load calculation panni video podunga bro

    • @civilonlycivil
      @civilonlycivil  Год назад

      @@vigneshbalaji591 thank for the feedback bro i try my best. 🥳

  • @rajavinothkumar1960
    @rajavinothkumar1960 Год назад

    Sir teach column position

  • @fakrudinahmed5141
    @fakrudinahmed5141 Год назад

    Boss i will pay ur fees can u teach me design

    • @civilonlycivil
      @civilonlycivil  Год назад

      Actually I was making a course, soon I will announce. 💓