Fault Finding Electrical Circuits - Electrician Life

Поделиться
HTML-код
  • Опубликовано: 19 авг 2020
  • Fault Finding Electrical Circuits - Electrician Life
    Join me as I trace a fault with a tripping RCD!
    Subscribe to our RUclips Channel for more great electrical content: ruclips.net/user/artisanelectr...
    🔔 Subscribe to TOOLS4SPARKS RUclips Channel 👇
    I Also Have A Dedicated RUclips Channel About Tools:
    ➤ / tools4sparks
    ✅ Check Out All Our Favourite Tools Here 👇
    ➤ www.amazon.co.uk/shop/artisan...
    --MY ENERGY PROVIDER--
    Bulb - Use this referral link and we will both receive £50! www.bulb.me/andrew8530
    🏷️ DISCOUNT BUSINESS SUPPLIES 👇
    ➤ www.amazon.co.uk/tryAB/?tag=a...
    -----TRADES INSURANCE DISCOUNT-----
    If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
    🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
    ➤ www.rhinotradeinsurance.com/quote
    📞 or call 01162437904.
    📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
    📸 Artisan Electrics Instagram Account 👇
    ➤ / artisanelectrics
    🐦 Artisan Electrics Twitter Account 👇
    ➤ / artelectrics
    📓 Artisan Electrics Facebook Account 👇
    ➤ / artisanelectrics
    This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
    #FaultFinding #ElectricianLife #ArtisanElectrics
  • НаукаНаука

Комментарии • 516

  • @artisanelectrics
    @artisanelectrics  3 года назад +23

    Watch the follow up video to this where I rewire the faulty cable here: ruclips.net/video/tUyvLSfB3qE/видео.html

    • @chazvirdee2012
      @chazvirdee2012 3 года назад +2

      What pliers do u use

    • @Lewdacris916
      @Lewdacris916 2 года назад

      @@chazvirdee2012 looks like knipex multi pliers

  • @Improveng1
    @Improveng1 Год назад +16

    Nice one Jordan. As a retired industrial maintenance engineer, I really appreciate a thorough, methodical, approach to fault finding, and, you definitely fall into that category. It's a big thumbs-up and a sub from me.

  • @jesperrasmussen9624
    @jesperrasmussen9624 3 года назад +51

    That is why we in sweden use pipes, so you can change the cables.

    • @tommymack3210
      @tommymack3210 3 года назад +6

      Tjena kungen!!
      Yes we use corrugated pipes in Norway too. Super flexible and bendable, if installed properly. Rewiring will be no problem

    • @PurityVendetta
      @PurityVendetta 3 года назад +14

      Unfortunately the UK hasn't caught on to common sense things like this. I've lived and worked in a few European countries and they all used some type of plastic conduit.

    • @tahirahmad4682
      @tahirahmad4682 Год назад +2

      we in Asia india Pakistan Bangladesh China. ...use conduit plastic pipes. rewire is so easy. but Indian domestic dwelling termination is a lot of doggy using tape on wire joints without wagos, connectors ...and open conductors everywhere around and above your head . ....

    • @npr1300A8
      @npr1300A8 Год назад +4

      @@PurityVendetta The one thing the UK leads with is the sockets. The European round pin system and the US flat pin systems are awful. The fact that each plug top is fused is also a great safety feature.

    • @PurityVendetta
      @PurityVendetta Год назад +2

      @@npr1300A8 I grant you the UK domestic three pin plug is the best in the world if properly fused. The only thing I've found not to like is accidentally treading on one in the dark with bare feet 😵
      Not the plug's fault but I do notice that many aren't appropriately fused as in fuse value.
      Great channel you have there Paul. I subbed and think I'll have to do a bit of binge watching 🙂

  • @TheTruthSeeker235
    @TheTruthSeeker235 3 года назад +6

    Licensed Electrical Engineer here. This is why I love my line of work. I get to troubleshoot and design.

  • @anatoljan5412
    @anatoljan5412 3 года назад +35

    I somehow stumbled upon this channel... and I am happy to do so... My father was an electrician... I was, and still am, interested in electricity and how it works (Dad passed away before I could ask him anything, but was always watching him while he was fixing stuff)... so thank you for making my "learning" easier and based upon real-life examples. You just got one more subscriber :D

  • @flawmore
    @flawmore 3 года назад +16

    Here is some bonus info from an electrician from another country.
    Every installed thing has a leak current, which is normal. But if too many devices are running through the same RCCB, it can add up to the point where it trips, even though there is no short circuit anywhere. A rare thing, but when it happens it's likely in a place like a restaurant kitchen or similar, where they have machinery that consumes a lot of power running over the same RCCB. Good to know if you end up in this situation, it may not be the first thing that comes to mind. Recommended max MCBs per RCCB where I live is 9. And that is for a normal household.

    • @JWu-jt7fz
      @JWu-jt7fz Год назад

      IET tells us to design based on 30% of the RCCB's rating (which is very conservative). The schedule of fault current based on device type can be found online too

  • @TeamSimpsonRacing
    @TeamSimpsonRacing 3 года назад +1

    Nicely done 👍. Very brave giving a time limit on fault finding. I always say it X for the first hour and then X per hour after and just keep the customer upto date with the progress.

  • @thomasbyles3075
    @thomasbyles3075 3 года назад +8

    Love these style videos they really help my training. Thanks Jordan

  • @leeturner3262
    @leeturner3262 3 года назад

    I am liking these sub-30min videos, there is something about having them less than 30min which makes me feel like they are easy to watch.

  • @adrianraith3831
    @adrianraith3831 3 года назад +1

    I had one just a few weeks ago on an overhead crane (I do industrial maintenance) with 2 separate S/Cs; one on motor wires snagging on a DIN rail, the second on a catenary cable - I think it was just pot luck which SC was tripping it at a given time....
    A 24vdc pilot lamp blowing fuses on a vacuum pump supply is another personal "favourite" find.
    I've seen also SCs where cables have been carelessly stripped and the insulation nicked ever-so-slightly with pliers / snips.

  • @Rob-bh2rx
    @Rob-bh2rx Год назад +1

    Brilliant fault finding. I never thought of using the multifunctional tester set on continuity, testing between each CB for the short circuit fault. Also giving the high and low resistance readings. I think I would of just used a continuity tester. Brilliant videos! 😊

  • @ddwalkerjr
    @ddwalkerjr 3 года назад +1

    It's remarkable how different the electrical terms and abbreviations can be so different. I am able to follow along, but without the visuals I wouldn't be able to lol

  • @floppyhammer5704
    @floppyhammer5704 3 года назад +1

    I work on public lighting and we use similar methods to find a short so we can replace that connection with new cable. Its realy fun and intresting, sometimes it can take us a cople of hours to zero in on problem if the street is long.

  • @rickycunningham6368
    @rickycunningham6368 3 года назад +3

    Great insight into the thought process you sparks have , I'll definitely be using this process when my rcds next trip

  • @giuseppe9145
    @giuseppe9145 Год назад +1

    Enjoyed your fault finding..
    I love fault finding really gets your brain going..
    In Italy we use corrugato..which i think translated Is conduit..easier to change or modify lighting..

  • @earthrelated
    @earthrelated Год назад

    You do the best troubleshooting videos man.Thank you!

  • @phillee2171
    @phillee2171 3 года назад +7

    Before I see the fault I was guessing a cooked cable in the vaulted ceiling with the halogen GU10s. Kingspan insulation and 50w halogens with cooked cables I have seen so much in recent years

  • @jacooosthuizen2977
    @jacooosthuizen2977 3 года назад +18

    Great insight into your process Jordan enjoyed it very much.

  • @ianjrivers
    @ianjrivers 3 года назад +4

    Damaged cable by another trade at the time of construction, most likely. It never ceases to amaze me how other trades think that pvc unarmoured cable is invincible. One time a plumber roasted in service lighting cables nearby to pipework, with his blowtorch, while installing a shower. The Insulation resistance readings weren't good....☹️

  • @jeffreytran9354
    @jeffreytran9354 3 года назад +1

    European electrical Main GFI. What a pain. You are an awesome electrician. I can see nothing wrong in the way you troubleshoot finding the ground fault. Customer going to have to live without three lights, until he is willing to tear the ceiling open and fix the wiring. Great job!

  • @devontegordon6606
    @devontegordon6606 3 года назад +1

    Bro i just saw this video and subscribed after watching it ..... I’m learning alot thank you 🙏

  • @munafmufc01
    @munafmufc01 3 года назад +1

    As always, enjoy watching your videos. Always informative. Your explanation is clear. Your a professional Jordan. Would like to see more fault finding vlogs. BTW where can I buy the cutter/snips you're using?

  • @johnyearsley7970
    @johnyearsley7970 3 года назад +1

    Well done Jordan. I am a qualified house electrician and then worked on heavy commercial vehicles and like you loved fault finding and as you said being s detective gave me such a buzz especially when you find the fault. Kind Regards John (love your programme especially how you started off being an electrician)

  • @Alan96555
    @Alan96555 3 года назад

    For some reason the youtube algorithm brought me here and I'm not disappointed! Good video!

  • @kingtawa
    @kingtawa 2 года назад +1

    Wow, learnt a lot from your video. Though I am not an electrician, I am happy that I would start trouble shooting from RCD just like you did. :)

  • @alexanderpye2509
    @alexanderpye2509 3 года назад

    Exactly the same as we do it over here 🇦🇺. Great watch mate and good find 👌🏼

  • @andrewdobson3518
    @andrewdobson3518 3 года назад +17

    I like your methods for fault finding. The only thing I would do differently is a full test of the rcd first on x1/2 then x1 and x5 and then a ramp test to make sure the rcd is going faulty under load. Once the rcd passes all tests I move on to the circuits as you did 👍
    Good job buddy

    • @artisanelectrics
      @artisanelectrics  3 года назад +1

      Andrew Dobson thanks!

    • @Ragnar8504
      @Ragnar8504 3 года назад +5

      Tripping when the customer plugs something in screams N-E fault so I'd probably check that before I did anything else.

  • @zamanraja9531
    @zamanraja9531 2 года назад +2

    Bro loving the video! You are helping a lot of young sparks like me man ! 💯 I’ve had an old consumer ( pull out fuses instead of Mcbs; and no rcds) so basically the lighting circuits of ground and 1st floor were wired in together like a ring. So I upgraded the CU first and separated it. However now I’m getting fault on ground floor. Downstairs is kitchen, bathroom and living room. LR is perfect however first thing is there is no live going to the switch ( I havent checked the actual light fitting to see if there is current going there). But even so I am totally baffled as a young sparky why it’s tripping 😅could you offer some help please and some advice on which tests to do?

  • @TLk36
    @TLk36 2 года назад

    ive only started wtahcing in the past month but this is so weird seeing how diffrent jordon is hes so much more calm you can tell in more current videos he became more confident

  • @RuffleCoptah
    @RuffleCoptah 3 года назад

    When I do this, I like to go to the first junction box from the central, and start disconnecting from there rather than going about trying to find a socket or switch thats faulty. It's down to a lot of luck, but I like this way of doing it too. Thanks for the information,.

  • @pauljones908
    @pauljones908 3 года назад +9

    I thought neutral to earth when you said it was tripping as soon as they plugged in 😁. I would have gone for the screw on the switch plate nicked a neutral when pushing it back or a metal light fitting with the same 😁. I do love a bit of fault finding! Loving the vids Jordan. Keep them coming 👍😁

  • @neilhoganwa
    @neilhoganwa 3 года назад +16

    I like fault finding as well. Gives you buzz when you find the fault. I would have tested the last switch before you had cut then to save more work.

    • @silverback6451
      @silverback6451 2 года назад

      It's better to not get a buzz when fault finding :D

  • @indefence7214
    @indefence7214 2 года назад

    Awesom!
    Thanks for sharing your knowledge.

  • @cheghegerhard5075
    @cheghegerhard5075 5 месяцев назад

    Thank you. This has enlightened me.
    There is an apartment being used as a Lounge which has been a headache for me. It's wired with a 3-phase supply.
    The 3phase main differential breaker trips periodically within the day. I've been on it for days to no avail in tracing the fault which I suspect to be leakage.
    I believe testing like you have should bring me positive results.

  • @CoolerQ
    @CoolerQ 3 года назад +6

    Love a good fault finding in the morning! 🙂

  • @petercarter5732
    @petercarter5732 Год назад

    I like how you broke down the wiring
    I would always check the RCD before going outside the board
    Recently had a similar fault it was the last light I checked
    Fault was a mouse had nibbled through the insulation cut out some nibbled cables fault sorted
    Thanks Jordan

  • @SuperPsychoDave
    @SuperPsychoDave 3 года назад +31

    I was screaming STOP in my head when you did the second cut on the cables behind the switch at the stairs. You could have done a quick measurement on the cables as they were and saved yourself some extra work.

    • @robertwheeler8476
      @robertwheeler8476 3 года назад +1

      I agree with you David... Just remove the lamps and drivers.... You could then find it in 10 minutes
      Why is no one trained properly... I ain't a electrician but all the video's I see just show incompentence ..... The issue is not the cable but what is connected to the cable... All he has to do is disconnect one leg ... either live or neutral and he would of found the fault..... Is it me or have we trained everyone with no simple diagnostic skills... I WILL SAY THIS AGAIN.. THE PROBLEM IS NOT A CABLE FAULT BUT WHAT IS CONNECTED TO THE CABLE... HE SHOULD BE FORCED TO RETRAIN... RANT OVER

    • @artisanelectrics
      @artisanelectrics  3 года назад +17

      It was a cable fault not a problem with anything connected you clearly haven’t watched the follow up video.

    • @Chequr_Prostate
      @Chequr_Prostate 3 года назад +2

      I love electricians who are perfect lol. I employed hundreds over the years, but sadly never met any, except me of course. 😉

    • @stuartmc18
      @stuartmc18 3 года назад +3

      @@robertwheeler8476 You're not an electrician, indeed. I am. When fault finding never assume anything. Break down the circuit methodically to find the fault. Also, removing lamps and drivers is often an absolute pig of a job especially crappy old halogen units. You end up with damaged ceilings where the heat from the light fitting has dried out the plasterboard. Awful things. Hooray for LEDs!

    • @robertwheeler8476
      @robertwheeler8476 3 года назад

      @@stuartmc18 I would guess a very poor electrician. I suspect you are a cable puller!!!

  • @doctorelectric470
    @doctorelectric470 3 года назад +33

    you done well to find that in 1 hour

    • @tommymack3210
      @tommymack3210 3 года назад

      Fault finding can vary very much! Me and a colleague spent 4 hours finding an earth fail, we found the fuse and there many old light fittings on that fuse. We took a guess that it was the source.
      But nooo, the very old light fittings were all good but there was 1 socket on that light circuit where an amateur had connected on that socket and he had screwed the wires to a pinch in the box..

  • @johnrumbles3068
    @johnrumbles3068 4 месяца назад

    This is pretty much the fault I have, even down to having the same consumer unit !!!! An electrician is coming tomorrow, and thanks to this excellent video, I have a very good understanding of what he will be doing. Top video, and now subscribed :-)

  • @carljames1134
    @carljames1134 2 года назад +1

    Mate between you and nick bundy, you give me, at 57 a new lease of life and getting back into sparkying.

  • @g1fsh
    @g1fsh 3 года назад

    Nicely worked out. Well done and quick too.

  • @terrytugwood7848
    @terrytugwood7848 3 года назад +7

    Great find and all within an hour, you’re good 👍

  • @mrcurely
    @mrcurely 2 года назад

    I like the thought process, so simple

  • @SqwarkParrotSpittingFeathers
    @SqwarkParrotSpittingFeathers 3 года назад

    Enjoyed that puzzling riddle. Lesson for today; can now have a nap.

  • @justme5384
    @justme5384 2 года назад

    I'm really thankful that we here mostly use ducted installations and usually have a junction box in the ceiling that is like switch box you use, inside the ceiling but accessable from the room under a lid. And usually the mains come from the board to that junction box, from there either to all lights separately or from box to first light and then from that light to the next. Might be without ducting between the lights but here if you do ductless cables they cannot be secured to anything, they must be able to move if a screw or something is screwed where the cable goes behind the plaster board or something. Not sure if anyone understands how I mean but I like our way. We also in older homes mount the cables on the surface, we might use MPLM cable for it with Schneider TKK fastenings

  • @g7eit
    @g7eit Год назад

    Great video and fault finding. I’m subscribing. Like how you pocketed the shield cuttings, I’d have thrown them in the bed 😂.

  • @howtogetajob4006
    @howtogetajob4006 3 года назад +3

    I loved fault finding, so satisfying when you find it.

    • @PM-vb4od
      @PM-vb4od 3 года назад +3

      I think you mean satisfying

  • @topgazza
    @topgazza 3 года назад +2

    Good common sense fault finding. I’m now a happy subscriber. Love your attitude and approach

  • @leonardcharlesnew1591
    @leonardcharlesnew1591 Год назад +7

    Don,t forget to rub your chin for a few seconds when customer asks how long it will take to do the job. When customer asks how much it will cost, turn the chin rub into a few seconds of scratching.. 🤔

  • @currentsolutions8467
    @currentsolutions8467 3 года назад

    Enjoying the videos mate. Thanks

  • @mathman0101
    @mathman0101 3 года назад +3

    Definitely a good one Jordan what’s exasperating is not fixing it in the time allocated and you know with the location fishing a new cable gonna be a nightmare. Possible nick when the boards were put up my guess and then heat damage from the halogens a distant second. I have to say it’s gonna be a bigger fix. A TDR or a Savary special could narrow the exact location of the fault with a bit of math. Then the option would be what we would do here in use cut the board at the location to get to the problem would help with fishing new wire as well. That way repair to the plasterboard would be less significant.
    The point is that issue has to be fixed sooner or later not sure kicking the can down the road by the customer solves anything other than leave himself with a headache.

    • @mathman0101
      @mathman0101 3 года назад +1

      Get to know a great plasterer that way you could get to price these jobs more effectively and broaden the scope of work you would want to do.

  • @MCKINJO
    @MCKINJO 3 года назад

    I've had that with Doncaster cables the neutral inside the cable had a slash in the sheath and was intermittently touching the earth in a kitchen, luckily an easy fix as it was just a leg between 2 sockets. But when you moved the cable the fault cleared. Its mad to think that it probably passed an initial eicr or not

  • @kaveengoonawardane9651
    @kaveengoonawardane9651 2 года назад

    Super useful video. Thanks mate.

  • @Blackf1ngers
    @Blackf1ngers 3 года назад +4

    I always keep a few 3.5mm pins in my pocket and a threading tool in my tester box. I spend pretty much all day testing social housing so I come across stripped screws several times a day.

  • @berenscott8999
    @berenscott8999 3 года назад +1

    Just wanted to ask a question. I'm starting a business from home that will use a lot of power, and I'd like to kind of work out, which household plugs are for each 10 amp circuit. What's the best way to do this? I mean, just plugging something in to each plug and having only one circuit turn on?

  • @elektrikeren5049
    @elektrikeren5049 3 года назад +2

    Classic fault finding process.💪🏻🇩🇰

  • @gainmaster1
    @gainmaster1 3 года назад

    Done plenty of this, good video

  • @colinpenfold2971
    @colinpenfold2971 3 года назад +2

    Good logical process. Nice work.

  • @3l511
    @3l511 3 года назад

    This was awesome man

  • @georgeedwards6620
    @georgeedwards6620 Год назад

    Hi Jordan I am a fan of your work just a quick question on insulation resistance test. Don't you have to remove bulbs and other electronic devices connected to the circuit before carrying out your insulation resistance test in the Distribution board circuits.

  • @mostlikelywedoitservices6926
    @mostlikelywedoitservices6926 2 года назад

    Nicely done.

  • @tigerteff015
    @tigerteff015 2 года назад

    As a retired service engineer always get as much info from the customer before fault finding as sometimes that points to the problem if not done already.

  • @mrm.k7655
    @mrm.k7655 2 года назад

    Did you hear about cable tracer its a kit that makes thing very easy to find the cable where it goes. Up to testing switching was fine after that i would disconnect all the lighting in that room tracing cables and insulation test each at the same time. You would save time in that way

  • @amarcy5369
    @amarcy5369 3 года назад

    Hi Is there mouse lose about this house 🤣 great job of detecting the fault . Admittedly the additive they put in cables is a deterrent to rodent damage. I have had a problem were a cable was damaged by a screw . But became problematic over time because of thermal movement in the property . O the joys of being an electrical contractor Best wishes Mike in the U.K. 👍

  • @nickhubbard3671
    @nickhubbard3671 3 года назад +22

    I like your testing - I would not have snipped the neutrals at 13:36 - I'd re-checked for the CPC neutral short first.
    Good fun - thanks.

  • @plunder1956
    @plunder1956 3 года назад

    Well found. You might get lucky catching and re-running the duff line, but it's a swine of a job.
    Loft conversions are a major source of wiring faults because each successive trade covers the fault with their work.
    I wish people would run conduit and individual wires (they insist on that in some EU countries).

  • @ionutonea1537
    @ionutonea1537 Год назад

    Lovely ! GOD bless you !

  • @nicolaj3799
    @nicolaj3799 3 года назад

    Excellent work proces

  • @MrMrutube1987
    @MrMrutube1987 3 года назад

    I'm not electrician but if i were id hate to watch one of your videos and think to myself.. hmm that house looks familiar lol.. and ur fixing my work lol 🤔🤫😂🤣

  • @stuartandrews4344
    @stuartandrews4344 3 года назад +4

    Mice,rats,bats,squrriels, birds in roof!Even seen a nail through roof batten & into a cable clipped to side of rafter,plasterboard nails/screws through plasterboard into cables, have always like fault finding,the fun you can have..A inspection camera,a very useful tool to have,can be a great help at times looking into cavities,etc.

  • @lukecrowther8130
    @lukecrowther8130 Год назад +1

    Favourite type of video, its was like watching a story unfold! Thanks

  • @gminor680
    @gminor680 Год назад

    Loving the videos, even though I am not in any way a trained electrician - so, I hope my question is not too daft. As the transformers do not have an earth cable to connect, would it be acceptable to disconnect the earth cables from where the fault occurs? I know that there "should" be an earth on lighting circuits, but as there is technically no need in this case, would it be a problem?
    (Accepting that the earth is shorting with the neutral.)

  • @harmonsalmon3313lfj
    @harmonsalmon3313lfj 3 года назад

    Nice work Jordan....

  • @latitudeash
    @latitudeash Год назад

    You did well to find the problem. I would do the same thing as you. How would I replace the wire? I will pull a new cord or chop plasterboard out using an obsoleting saw. Easy to patch back up but time consuming

  • @delchaspmedia5099
    @delchaspmedia5099 Год назад

    Well done 👍

  • @edlowry1
    @edlowry1 3 года назад

    Troubleshooting 101, good job

  • @farmerdave7965
    @farmerdave7965 3 года назад +32

    Someone probably put a nail or screw through the wiring. Time to remove drywall and do rewiring. Expensive repair.

    • @rongray4118
      @rongray4118 3 года назад

      Good point! Even when conduit is used...it happens on occasion with a wild drywaller!

    • @OprichnikStyle
      @OprichnikStyle 3 года назад +2

      well they did the best to let it happen. wires all hanging there not even in a propper conduit like a pvc tube.

    • @samwood34
      @samwood34 3 года назад +1

      Iván Pstyga in the UK it’s not required to have any protection on cables buried in the walls

    • @OprichnikStyle
      @OprichnikStyle 3 года назад +1

      @@samwood34 in my country there are a few ways but the most used is placing pvc tubes and I must only use up to 35% of the section area of the tube* the rest should be free to dissipate any heat that could occur. What I dont understand is if your breakers are unipolar or bipolar for 220V they really look like only 1 slot for the phase

    • @maa1649
      @maa1649 3 года назад

      @@OprichnikStyle Yes totally agree must be a nightmare to come across something like that especially for the customer. In other countries pvc tubes are used unilaterally everywhere so its as easy as pulling new wires through and connect and of you go.

  • @JimBlair
    @JimBlair 7 месяцев назад

    Nice video Jordan. I too love fault finding, but since i'm not a certified electrician, I'm not clear what your terminology means...would you consider making a short schematic of the circuits and talking your debugging strategy over the schematic, so someone that understands electrical circuits understands the underlying implementation architecture? (or maybe an idea for future debugging scenarios?) Thx, Jim

  • @martinwragg8246
    @martinwragg8246 3 года назад +2

    I used a small neo magnet tapped to a nylon garden twine, then a very strong neo magnet to pull it across 10 metres of plasterboard ceiling, then tie on cable and pull in.
    Jobs a good en ! 😉

  • @stikndip
    @stikndip 2 года назад

    Great stuff but invest in a battery driver!
    What's that plier/stripper tool you use, btw? Looks great!

  • @fredziffle1991
    @fredziffle1991 Год назад

    I had a job where the customer (a mate at work) had had a garage workshop installed and it was powered up then when they plugged a lawn mower in it tripped. The lecy who installed the garage system said your mower is faulty but did not come to site.
    I looked at the install and found the lecy had put the neutral in the wrong side of the split load board back in the house.! Moved it across to the neutral bar on the same side as the live. Job done!!!!
    Foot note: the mower was fine it tripped as soon as you plugged in anything....

  • @pjvenda
    @pjvenda 3 года назад

    When you mentioned it was a modern build and therefore switches were wired to neutral ... What did you mean by that?
    One thing I think I spotted was absence of rose joints, so live and neutral come from switch box. Is that what you meant by modern wiring?

  • @ImranKhan-cf8gs
    @ImranKhan-cf8gs 3 года назад

    Very good way of finding a fault quality work sparks

  • @MrRdt1970
    @MrRdt1970 3 года назад +1

    Good vid keep it up 👍

  • @chrishulshof8162
    @chrishulshof8162 3 года назад

    In the Netherlands we have a max of 5 mcb's behind a RCD. More mcb's means more RCD's . In you case to much leakage of the single RCD

  • @mikewilkinson7802
    @mikewilkinson7802 3 года назад +7

    You could use Nick Bundy’s spare plasticon and surface mount it😉😂

  • @donnierobertson3088
    @donnierobertson3088 3 года назад

    Great job and video

  • @jonahfernandes8885
    @jonahfernandes8885 3 года назад +1

    I m a Electrician and i find fault finding, but in my country in India some Electrician who do the original wire up create such a mess to trace the fault it becomes difficult but after all thats the best part of the job.

  • @jamespetre
    @jamespetre 3 года назад +1

    When you zoomed in on that junction box I had a flashback to when thousands were used on 2 sites that I was on. They’re Hager and have even been stripped and connected in the same way. Personally, I always thought it better practise to bring more of the outer insulation in and loop them into a ‘J’ shape so that the Line & Neutral T&E would go into the terminal at the bottom of the terminal rather than at the top.

  • @dannylad1600
    @dannylad1600 3 года назад

    I'd love to work in electrics. I find it so interesting especially the problem solving side of it.

    • @jasonhounsell3297
      @jasonhounsell3297 3 года назад

      Aye, wait until your on a timescale, and in a house and can’t find the fault, and your like an idiot not being able to find it and the customer knows it 😂😂

    • @dannylad1600
      @dannylad1600 3 года назад

      @@jasonhounsell3297, yeah you're probably right. I should have probably said I'd love to work in electrics while knowing what I'm doing.

    • @alexpryce555
      @alexpryce555 3 года назад

      That's why i never give a timescale for fault finding 😂

  • @gamleole9568
    @gamleole9568 3 года назад +1

    You might wanna search for dry wall screws with a magnet perhaps. Who knows, you might get lucky.
    You could perhaps use a cable finder to track the cable if you open it in both ends (to check for screws in its path)

    • @leetaylor5988
      @leetaylor5988 Год назад

      The cable finder always works for me simple and effective, then you can work most things out off the back of that ....

  • @tompickford2697
    @tompickford2697 3 года назад +48

    Turn the plate screws upside down and put through the faceplate so you don’t have to go looking through your pockets!

    • @1jim58
      @1jim58 3 года назад +8

      Wind them a couple of turns into the back box.

    • @The160879
      @The160879 3 года назад

      @@1jim58 taught that day one keeps them from getting lost

    • @NicosHalvatzis
      @NicosHalvatzis 2 года назад

      Very clever,, I learn something today, thanks

  • @francescodifoggia2373
    @francescodifoggia2373 2 года назад

    Could i please know the clamp model you are using? It looks like very professional.
    Thank you.

  • @bartrazin
    @bartrazin Год назад

    7 MCB´s on a single RCD? In The Netherlands there is a maximum of MCB´s you can put on a RCD and that is four. My humble switchboard has two RCD,,s with six MCB´s with one being a combined group for an induction cooker(2 Phase/@ Neutral).
    Earth leakages are some of the most difficult malfunctions in an installation esspecially in a house where everything is covered up. Great stuff!

  • @MrRdt1970
    @MrRdt1970 3 года назад +2

    Bit dusty but put new lights cable in use mini saw DreMel type then seal and plaster over trace done lots of times

  • @petermugambi9122
    @petermugambi9122 9 месяцев назад

    I normally use an ohmmeter and it works fine, but we hardly use RCDs in Kenya, a double pole isolator and Mcbs is all you will get in a consumer unit.

  • @bartholomewkangyi4702
    @bartholomewkangyi4702 3 года назад +1

    Thanks for sharing Nice video. Pls I want a support with electrical tools to also start with practicals.

  • @leonblittle226
    @leonblittle226 3 года назад +2

    That's one of several things to hate about downlights, you have a set of christmas tree fairy lights and transformers and junctions strung in the roof rather than a simple pendant and switch live. At least with these new wireless light offerings you have a central junction point and feeds out from there.

    • @tommythomson99
      @tommythomson99 3 года назад

      I absolutely love the wireless switches. Total godsend 👍

  • @northy3217
    @northy3217 3 года назад +4

    Grab yourself an earth leakage tester Jordan do your 1st process with the Mcbs then if the RCD resets clip the earth leakage on and switch off one by one till it drops saves ages.

    • @artisanelectrics
      @artisanelectrics  3 года назад

      Northy 32 nice tip! I do have one but forgot to use it! Thanks

    • @lorzor9182
      @lorzor9182 3 года назад

      @@artisanelectrics i have the 1664fc and i have had mixed results with the ramp tests. They are never ever consistent, I have ended up chasing my tail with it. I hardly ever use it to be honest and I don't think it would have saved much time.

    • @lifter98
      @lifter98 2 года назад

      It could be the case though, that when you switch an MCB off and the leakage reading drops, it's a neutral fault, the fault could be on another circuit?

  • @ReneUnderby
    @ReneUnderby 3 года назад +5

    your'e doing a great job but at 15:15 i would have removed one of the lights at the back of the room cutting the string of lights in 2 parts after that i would have probably gone for the one in the middle on the left side.

    • @elg281
      @elg281 3 года назад +1

      Thats my method.