REPLACING THE CONTROLLER OF REEFER CONTAINER | ETO TROUBLESHOOTING

Поделиться
HTML-код
  • Опубликовано: 24 янв 2025

Комментарии • 68

  • @DANI-ru3vt
    @DANI-ru3vt 4 года назад +3

    Without tr.eto you are doing all this job. I am really appreciate you sir.. One of the best honorable ETO. I am waiting for your next reefer knowledge sharing video. Plenty thinks I am learning from your videos only..Thank you so much sir.

  • @pabalarox8853
    @pabalarox8853 3 года назад +1

    Thank you lecky for your information . I also reeferman. I wish your future

    • @leckyjake
      @leckyjake  3 года назад +1

      Thank you for the support

  • @janehidalgo3724
    @janehidalgo3724 4 года назад

    Thank you sir same pag share palagi ng video, it helps more... Good bless always...

  • @PracticalMECEngineStudy
    @PracticalMECEngineStudy 3 года назад

    Much appreciate your effort in making such a nice and step by step troubleshooting video

  • @ahmedbaqi540
    @ahmedbaqi540 10 месяцев назад

    Your videos are fantastic! I love how you start each one with a scenic view of marine industry. It really sets the tone. However, I think the intro scene could be a bit shorter to keep viewers' attention. Thank you for sharing your knowledge 🙏

  • @sadroolhaque
    @sadroolhaque 4 года назад +1

    Thank you Sir, Your video helps me to learns lots of things.

  • @musakavalci9470
    @musakavalci9470 2 года назад

    Another excellent video. Well explained and keep them coming👍🏼

  • @jaimebernales5164
    @jaimebernales5164 4 года назад +1

    New subscriber here, thank you for the information this will help me for my future career.

  • @edilbertohermosa8908
    @edilbertohermosa8908 3 года назад +1

    Boss i dont have expercience in reefer but i saw your video i learn lot and understand coz im working at ammonia industrial refrigeration i want to experience in reefer can you advice me what i can do first to join reefer same like you

  • @juancarlosisaza8066
    @juancarlosisaza8066 3 года назад

    el mejor tutorial que he visto felicitaciones ,estamos en contacto
    estoy en colombia y soy tec reefer

  • @brahim21261
    @brahim21261 3 года назад

    Very good excplenation thank you my friend. 👋👋👋👌🏼

  • @biniyamdesalegn7385
    @biniyamdesalegn7385 4 года назад +1

    Thank you, Sir... Fair winds and following seas!

  • @RyanDuran-hz5tk
    @RyanDuran-hz5tk Год назад

    do they alo have extra harness or connector?

  • @jobztv534
    @jobztv534 3 года назад

    Nice video lecky

  • @joelboyd9266
    @joelboyd9266 2 года назад +1

    I have a reefer starcool that’s displays no phase detection 423 starcool unit unit has been running fine for a week now in range did my Morning round this morning aboard ship noticed unit off turned it back on and got that alarm in the past most time I could switch two leads on the plug or change it out and be good no dice so I changed the power measuring board cable to the unit also bypass the fc still no dice show I had a spare cable I ran just to test to see if it was the cable k got 440 across each phase but I am still displaying 330 across each phase on the display Do YOU think it might be the controller

    • @leckyjake
      @leckyjake  2 года назад

      just go to the configuration and choose phase detection to CW or CCW depending on the correct rotation of your fans.

  • @sivaprsads8567
    @sivaprsads8567 4 года назад

    Thank you sir for making such videos

  • @Sim-x5i
    @Sim-x5i Год назад

    Jack... Can you please tell about tech work squad on a cruise ship position...
    What is the duties and responsibilities of a that position ( tech work squad)

  • @Arunkumar-lp1pk
    @Arunkumar-lp1pk 4 года назад

    Awesome video sir!!

  • @johncantrell614
    @johncantrell614 2 года назад

    Do your ship normally have a large amount of these kinds of spare parts on board for these refer boxes, and do you sometimes have to deal with boxes of other brands, or are they mostly the same manufacturer used?

  • @sagkatv1929
    @sagkatv1929 2 года назад

    Pa content po yung CI or cold ironing. Thanks.

  • @gabgilgabgid3599
    @gabgilgabgid3599 4 года назад

    Thanks for sharing sir.

  • @dilipsangada6691
    @dilipsangada6691 4 года назад

    Nice sir

  • @aungkowinkyi8549
    @aungkowinkyi8549 2 года назад

    Tks you very much indeed.

  • @16valve64
    @16valve64 3 года назад

    Thanks a lot

  • @life_xplorer
    @life_xplorer 3 года назад

    Very nice video.. promote channel to next level.
    Sir NSK YSK meas
    And sir please make video on how and what controller settings we have to do for dikine reefer.

  • @TOMATO49911
    @TOMATO49911 4 года назад +2

    Good info lecky! 👏 But why you did not call the port reefer technician, instead?

    • @leckyjake
      @leckyjake  4 года назад +1

      It was the second to the last container that was loaded hence no more time to call for technician

  • @puneethk3851
    @puneethk3851 4 года назад

    Great content @leckyjake ,is eyesight or lasik acceptable in merchant navy

  • @REC1GOTADREAM
    @REC1GOTADREAM Год назад

    Hello I have a question . My display is not getting any power . Tryed my other control and still not working . Followed it back to K11 any help ?

  • @AAminy
    @AAminy 9 месяцев назад

    thanks

  • @brahim21261
    @brahim21261 2 года назад

    I have Al J291 Daikin LXE10E 136A
    I cant find it the problem

  • @jecsonfanergo8653
    @jecsonfanergo8653 4 года назад

    sir good day. i have a problem i hope u help me. it regards. in generator set. cummins faraday. if the gen set alarming. the error indicates in module display. is over voltage what is cause problem.

  • @AAminy
    @AAminy 9 месяцев назад

    THANKS

    • @سيدسيد-ض6غ
      @سيدسيد-ض6غ 5 месяцев назад

      هل لي ان اتواصل معك سيدي
      انا اعمل في هذا المجال
      واريد التعلم منك
      اذا تسمح لي

  • @matandemtech4404
    @matandemtech4404 4 года назад +1

    Master pwede b I convert ung daikin EEV into other EEV and what brand can fit to daikin EEV

    • @leckyjake
      @leckyjake  4 года назад +1

      Mag emergency cap/magnet ka nalang

  • @meetsunder
    @meetsunder 3 года назад

    please make a video on how to run reefer in controller bypass mode

  • @chathutangakumara3615
    @chathutangakumara3615 4 года назад

    thank u sir

  • @uolevejsaibesa2230
    @uolevejsaibesa2230 3 года назад

    Sir how about the model of CA controller magkaiba ba un sa ibang controller ng starcool, nag palit kc ako ng controller ng CA unit ang pinalit ko is SMC 6.2
    pero after ko ikabit nakalagay sa display not same program..
    Ano dapat ko gawin sir dapat ba iprogram ko un kc hnd ako marunong mag program

  • @venkatavala4284
    @venkatavala4284 4 года назад +1

    Good information sir , but one thing after immediate loading , if any alarm is there , can we call techn.

    • @C.Stenley.M
      @C.Stenley.M 3 года назад

      Or unloading this unit to ashore back 🤣🤣🤣

    • @ivanfmartinezm
      @ivanfmartinezm 3 года назад

      All those reefer containers has been checked previously no fail should occur

    • @leckyjake
      @leckyjake  3 года назад +2

      They running machineries that can get malfunction at any given time, especially transporting from the port, to track and loading to the vessel, lifting them up maybe 30-50 meters high and put down from that height. The bang, vibration and shock it may happen.

    • @C.Stenley.M
      @C.Stenley.M 3 года назад +1

      @@leckyjake that is true jake... after load just checked unit not running.... open panel and found all contactor was not attached well... some fuse torn out... yeah 🤭🤭

    • @venkatavala4284
      @venkatavala4284 3 года назад

      @@leckyjake good job ... videos are reference to us

  • @maksymmorga9423
    @maksymmorga9423 3 года назад

    👍

  • @muneerkhan8127
    @muneerkhan8127 3 года назад

    By checking resistance how you find out that pressure switch is closed I could not understand? what's the relation ?

    • @leckyjake
      @leckyjake  3 года назад

      if alarm is active but the pressure switch resistance is closed then the alarm should not be there.

    • @muneerkhan8127
      @muneerkhan8127 3 года назад

      @@leckyjake what do you mean by pressure switch resistance is closed?

    • @lousassole9339
      @lousassole9339 2 года назад

      @@muneerkhan8127 Well if the pressure switch is open then what resistance would you expect?

  • @fahimjamader9830
    @fahimjamader9830 6 месяцев назад

    Why don't you make more videos on Reefer Container ?
    We are waiting for your new videos.❤

  • @cyrildelacruzjr4365
    @cyrildelacruzjr4365 4 года назад

    Keep SAFE 🙏

  • @satyendramishra8312
    @satyendramishra8312 3 года назад

    satayendra Kumar mishra

  • @satyendramishra8312
    @satyendramishra8312 3 года назад

    reefer container technicians

  • @srirambalajir237
    @srirambalajir237 4 года назад

    It is dangerous to work in ship as ETO officer

  • @ivanfmartinezm
    @ivanfmartinezm 3 года назад

    I think this ship have a reeferman onboard because you have too many job onboard without enough time to attend every thing i believe this ship is very huge about 8000 Teus or more imagine 1000 reefers containers onboard to you alone

    • @leckyjake
      @leckyjake  3 года назад

      We have a ship that has the capacity of 1, 707 reefer containers alone. The biggest we have is having 19,600 TEUS.

    • @ivanfmartinezm
      @ivanfmartinezm 3 года назад

      Good afternoon Mr. Jake i would like speak to you about job right now i'm unemployed could you please send to me any contact way??? Thank a lot in advance take care of yourself

  • @paulalvarez4385
    @paulalvarez4385 Год назад

    The unit continue AW307 😅 UNIT STOP

  • @kowalski8
    @kowalski8 Год назад +1

    Why this loud music? Why?