Installing a Daikin Ductless Mini Split
HVAC⎪HVACR⎪REFRIGERATION VIDEOS
In this video I replace a Mitsubishi Electric Air Conditioner with a Daikin. Enjoy the video.
Просмотров: 2 619

Видео

How to test Daikin PCB for Communication Faults.
Просмотров 1,7 тыс.День назад
In this video I show you how to test if a Daikin PCB is communicating normally or abnormally.
Diagnosing Daikin E5 Error
Просмотров 3,8 тыс.День назад
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I diagnose what's wrong with a Daikin Air Conditioner displaying an E5 fault code. Marac Services Pty Ltd Located in Sydney.
Actron Air Conditioner displaying E9 Fault
Просмотров 1,7 тыс.14 дней назад
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I attend a job where the customer has said that the Air Conditioning system has been working fine on cooling but since using it on heating, has been coming up with an E9 error code.
Mitsubishi Electric Air Conditioner displaying P8 Fault
Просмотров 1,9 тыс.Месяц назад
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I try to find out why this Mitsubishi Air Conditioner isn't running.
Re Installing Daikin Air Conditioners
Просмотров 2,1 тыс.Месяц назад
HVAC ⎹ HVACR ⎹ REFRIGERATION VIDEOS In this video I return to a job to re connect the customers Air Conditioners. I disconnected them so they could get their house cement rendered.
I CAN'T BELIEVE that this has happened AGAIN!
Просмотров 3,3 тыс.Месяц назад
HVAC⎪HVACR⎪REFRIGERATION VIDEOS In this video I come across an issue with this unit. What's weird though is that I fixed the exact same issue one and a half years ago on this exact system. What is causing this to happen again? Watch on to find out what the issue is.
Fujitsu Air Conditioner not working
Просмотров 3 тыс.2 месяца назад
HVAC | HVACR | REFRIGERATION VIDEOS In this video I fix an Air Conditioner that was making a loud noise and not working properly. The problem was the inverter PCB.
Actron Air Conditioner | Fans running but not blowing cold air
Просмотров 1,4 тыс.2 месяца назад
This is a video where I remove an Actor Soft Starter and replace it with a contactor. I also replace the 80uF capacitor to get this unit running again for the customer. Marac Services Pty Ltd (Sydney Metro) 0416 378 527
Replacing the compressor on a Temperzone Air Conditioner.
Просмотров 3,3 тыс.5 месяцев назад
Replacing the compressor on a Temperzone Air Conditioner.
Temperzone Air Conditioner tripping the circuit breaker.
Просмотров 2 тыс.6 месяцев назад
Temperzone Air Conditioner tripping the circuit breaker.
ACTRON AIR CONDITIONER NOT COOLING!!
Просмотров 3,8 тыс.6 месяцев назад
ACTRON AIR CONDITIONER NOT COOLING!!
ACTRON AIR CONDITIONER NOT BLOWING COLD AIR?
Просмотров 3,2 тыс.6 месяцев назад
ACTRON AIR CONDITIONER NOT BLOWING COLD AIR?
INSTALLING AN R32 DAIKIN DUCTED AIR CONDITIONER
Просмотров 3,2 тыс.7 месяцев назад
INSTALLING AN R32 DAIKIN DUCTED AIR CONDITIONER
How to clean a Ductless Mini Split.
Просмотров 2,1 тыс.7 месяцев назад
How to clean a Ductless Mini Split.
HVAC VAN BUILD⎟Episode 5
Просмотров 1,4 тыс.7 месяцев назад
HVAC VAN BUILD⎟Episode 5
INSTALLING A DAIKIN R32 DUCTED AIR CONDITIONER AND WHY I USE 'MyPlace' from ADVANTAGE AIR.
Просмотров 11 тыс.8 месяцев назад
INSTALLING A DAIKIN R32 DUCTED AIR CONDITIONER AND WHY I USE 'MyPlace' from ADVANTAGE AIR.
Repairing Daikin UF Error
Просмотров 2,2 тыс.8 месяцев назад
Repairing Daikin UF Error
INSTALLING AN R32 DAIKIN DUCTED INVERTER AIR CONDITIONER
Просмотров 7 тыс.8 месяцев назад
INSTALLING AN R32 DAIKIN DUCTED INVERTER AIR CONDITIONER
ALL THIS COULD HAVE BEEN AVOIDED!
Просмотров 1,5 тыс.8 месяцев назад
ALL THIS COULD HAVE BEEN AVOIDED!
Diagnosing Daikin U2 Error | # 2
Просмотров 8 тыс.8 месяцев назад
Diagnosing Daikin U2 Error | # 2
Diagnosing Daikin UF Error
Просмотров 3,5 тыс.8 месяцев назад
Diagnosing Daikin UF Error
Repairing Panasonic F91 Error
Просмотров 4,9 тыс.9 месяцев назад
Repairing Panasonic F91 Error
INSTALLING A DAIKIN R32 INVERTER MINI SPLIT AIR CONDITIONER
Просмотров 14 тыс.9 месяцев назад
INSTALLING A DAIKIN R32 INVERTER MINI SPLIT AIR CONDITIONER
HOW TO INSTALL AN R32 DAIKIN DUCTED AIR CONDITIONER?
Просмотров 10 тыс.9 месяцев назад
HOW TO INSTALL AN R32 DAIKIN DUCTED AIR CONDITIONER?
How to Cut 90 ⁇ Bends on Metal trunking
Просмотров 2,3 тыс.10 месяцев назад
How to Cut 90 ⁇ Bends on Metal trunking
Installing the DAIKIN R32 INVERTER UNDERFLOOR AIR CONDITIONER with AirHub Linear Zones.
Просмотров 4 тыс.10 месяцев назад
Installing the DAIKIN R32 INVERTER UNDERFLOOR AIR CONDITIONER with AirHub Linear Zones.
ACTRON AIR CONDITIONER NOT WORKING?
Просмотров 3,9 тыс.10 месяцев назад
ACTRON AIR CONDITIONER NOT WORKING?
Installing an R32 Daikin Multi Lite Ductless Mini Split Air Conditioner.
Просмотров 4,3 тыс.10 месяцев назад
Installing an R32 Daikin Multi Lite Ductless Mini Split Air Conditioner.
HOW TO FIX DAIKIN DUCTLESS MINI SPLIT R32 AIR CONDITIONER WITH NO FAULT CODES.
Просмотров 2,4 тыс.10 месяцев назад
HOW TO FIX DAIKIN DUCTLESS MINI SPLIT R32 AIR CONDITIONER WITH NO FAULT CODES.

Комментарии

  • @mattandreatta
    @mattandreatta 20 часов назад

    Appreciate the video mate. Fixed in less than a minute, including Google search.

    • @maracservices
      @maracservices 19 часов назад

      @@mattandreatta no worries mate 👍🏻

  • @bibeksingwxhbibeksingh5101
    @bibeksingwxhbibeksingh5101 2 дня назад

    5 ton o general Ac duct types I need to get work

  • @bibeksingwxhbibeksingh5101
    @bibeksingwxhbibeksingh5101 2 дня назад

    O general duct types 4 ton right 👍

  • @bibeksingwxhbibeksingh5101
    @bibeksingwxhbibeksingh5101 2 дня назад

    I need work brother I know this works HVAC vrf also duct types I have good experience

  • @defuzd
    @defuzd 3 дня назад

    G’day Mitch, what’s the most common reason why the internal circuit breaker trips!?? Other than ceiling filters… cheers thanks legend!

  • @nanbinwang692
    @nanbinwang692 3 дня назад

    use 20mm saddles

  • @BrentLambert-u1x
    @BrentLambert-u1x 4 дня назад

    G’day Mitch, I’m happy to report that it has been smooth sailing since you left our place. We haven’t tried the ESP setting as yet - we might give it a whirl this week. Can’t thank you enough - your time here, along with your diagnosis, has given us complete peace of mind. Thank you very much!

  • @musakavalci9470
    @musakavalci9470 4 дня назад

    Very nice work. 👌🏼

  • @salvatoregiovanni8967
    @salvatoregiovanni8967 4 дня назад

    Just fyi, at 6:03 you forgot to say “That’s not going anywhere.”

    • @maracservices
      @maracservices 3 дня назад

      @@salvatoregiovanni8967 haha I thought it though haha. I just didn’t “say” it!

  • @moisander8858
    @moisander8858 4 дня назад

    All Mitsubishi Electric minisplit indoor units open that way, old and new. Newer ones have detachable corner pieces, which makes it much easier to open

    • @maracservices
      @maracservices 3 дня назад

      @@moisander8858 ah okay. If the sides detach, that’d be easier!

    • @moisander8858
      @moisander8858 3 дня назад

      @@maracservices Yeah, on older ones if they are not going to be re-installed, i just hammer or cut the corners so i can get my fingers under

  • @TheRealJRC
    @TheRealJRC 4 дня назад

    The music isn’t helpful. Would be nice to hear your thoughts on the units and hear them.

  • @nailgunana2902
    @nailgunana2902 4 дня назад

    this motor, from inverter Daikin?

  • @stephenlawlor3973
    @stephenlawlor3973 5 дней назад

    Winter in Oz and a clear blue sky, you wearing shades, shorts and a t-shirt, meanwhile in Ireland its 11c , raining and miserable and its the summer😢

    • @maracservices
      @maracservices 3 дня назад

      @@stephenlawlor3973 haha ireland sounds like a real hoot 😂 I’d be there to if my grandparents weren’t convicts lol

  • @musakavalci9470
    @musakavalci9470 5 дней назад

    Worth paying the little extra for quality. Mitsubishi electric for me!

  • @musakavalci9470
    @musakavalci9470 5 дней назад

    Great stuff as always. Thanks 👍🏼

  • @MentalLapse09
    @MentalLapse09 5 дней назад

    Hey mitch. Not a big daikin man, but I've heard warranties being knocked back by their agents for using the blue interconnects. You hear of this?

    • @maracservices
      @maracservices 3 дня назад

      @@MentalLapse09 I haven’t but to be fair, I do my own Daikin warranty so i just do what I want and it’s no questions asked. If I got someone else to do it, maybe they would question it. I have heard that using 3 core and earth cable isn’t ideal so I should probably change cables but I’ve never heard of anyone actually running unit Daikin warranty problems. It wouldn’t surprise me though.

  • @timhutton1818
    @timhutton1818 5 дней назад

    Just found your channel mate, great informative videos, have already learnt afew things (and ive been on the tools for years) thanks, keep it up

  • @craigladewig3158
    @craigladewig3158 5 дней назад

    I use a cable tie to unclip, slide the "head" of the tie behind the unit and pull

    • @maracservices
      @maracservices 3 дня назад

      @@craigladewig3158 that’s a good idea mate

  • @gokhanturkyilmaz3443
    @gokhanturkyilmaz3443 5 дней назад

    You could always measure from centre to exit hole. Then use stud finder. This will save a little time also and not have to drill then move

  • @jixia676
    @jixia676 5 дней назад

    Thanks Mitch, Do you know how to confirm if its the ourdoor PCB problen or indoor PCB problem?

  • @robalexander7348
    @robalexander7348 5 дней назад

    A nice neat job Mitchel, as always, i did miss Tom operating that lifting hoist 😉 😉 👍

  • @jimmyteesahn
    @jimmyteesahn 5 дней назад

    I keep an offcut of solder in the toolbag bent into a little hook for unclipping the bottom of those indoor units 🤙🏻

    • @Bertjanvandermeer
      @Bertjanvandermeer 5 дней назад

      I use two tie-wraps.

    • @maracservices
      @maracservices 3 дня назад

      @@jimmyteesahn thanks for the tip mate. I’ll be doing the same haha.

  • @dylb8801
    @dylb8801 6 дней назад

    Just got the going out outfit on ready for a cute date after lol

    • @maracservices
      @maracservices 5 дней назад

      @@dylb8801 what haha. It’s the same gear as always, just was wearing shoes instead of my boots. The boots we soaking wet so left them out to dry lol

    • @dylb8801
      @dylb8801 5 дней назад

      @@maracservices Just stirring Mitch. Seen the fresh white Nikes and thought you were just smashing out a install before heading out lol

    • @maracservices
      @maracservices 5 дней назад

      @@dylb8801 haha all good mate !

  • @paulbrown1079
    @paulbrown1079 6 дней назад

    Greetings from London England not wearing flip flops sunshine your letting your country men down . Great video and loved the hydraulic lifter for the roof and big shout out for installation of a isolator .

    • @maracservices
      @maracservices 5 дней назад

      @@paulbrown1079 flip flops haha you definitely are from England. They’re called thongs mate. Cheers mate, that lifter was a good investment. Definitely comes in handy!

  • @groodman1
    @groodman1 6 дней назад

    Could you send me a link for the isolator ? Thanks

    • @maracservices
      @maracservices 6 дней назад

      @@groodman1 directwholesale.com.au/products/clipsal-wha116rg-isolator-ip66-1p-16a-250v-wha-series-r-g/?gad_source=1

    • @maracservices
      @maracservices 6 дней назад

      Once again, this is a random link. I didn’t buy it from these people. I just get it from my electrical wholesaler.

  • @groodman1
    @groodman1 6 дней назад

    What type of lift is that ?

    • @maracservices
      @maracservices 6 дней назад

      @@groodman1 this is a random link that shows you what lifter it is. I didn’t buy it from these people though. Cheers www.material-lifts.com/product/genie-model-gh-3-8-super-hoist-material-lift/

    • @andyjones7836
      @andyjones7836 5 дней назад

      Nice job, what gas do you use for the lifter (CO2 or is that nitrogen)? Cheers

    • @maracservices
      @maracservices 5 дней назад

      @@andyjones7836 thanks mate, it’s a CO2 lifter.

  • @dylb8801
    @dylb8801 6 дней назад

    Doctor cross thread

  • @juanantoniog5875
    @juanantoniog5875 7 дней назад

    Muy buenos vídeos para cuando el canal en español????

  • @juanantoniog5875
    @juanantoniog5875 7 дней назад

    Gracias por compartir sus conocimientos

  • @dar9433
    @dar9433 7 дней назад

    Hi Mitch, I'm not sure if you mentioned it in the video, but the ESP mode is external static pressure mode , so the board will have sensors mounted in the supply and return ducts to measure this pressure difference and then controll the fan speed to maintain this setting, my thinking on this would be with all zones open the fan is moving more air easier so to speak , max duct area available, so the ESP is lower , ie difference between supply and return duct pressure is say , 0.3 inches of water column we'll call this the setpoint, and full air volume being moved.When a zone is closed , the difference between supply and return duct pressure increases , say to 0.5 inches of water column, due to less area available for air to move thru, say 75% available as it's only operating on 3 of the 4 zones. The board now sees the 0.5 water column, with a 0.3 setpoint , so it reduces the fan speed to reduce the ESP back to setpoint. This then reduces the air volume across the coil and causes the unit to trip on HP. I wonder is this a newly installed unit or possibly your first visit?. You were correct in shortening the ducts and making smooth bends where possible, I think the unit is oversized for the ductwork, or another way of saying it, the ductwork is undersized for the unit. You hit the nail on the head with your diagnosis.. Is there variable speed on the outdoor unit fans?.. Great content, keep it up...

  • @andrewkofi7938
    @andrewkofi7938 7 дней назад

    Good jobs

  • @richardbartlett6932
    @richardbartlett6932 7 дней назад

    Just seen this, sticking your leak tester up the insulation would have shown you the leak straight away.. This should be part of any leak test before you get to the pressure testing stage. however we have had loads and loads of linesets failing . Cheap Chinese copper is to blame.

  • @jamesmccann8896
    @jamesmccann8896 7 дней назад

    @maracservices Hey mate! The 7 on the remote is actually a T for test! With an e5 fault the high chance of compressor seizure with your failed board, good call with the condemn of unit Would have been good to see if you had a strong insulation resistance reading or not

  • @CapitalCoastHVAC
    @CapitalCoastHVAC 7 дней назад

    How do you go with the cover he he.

  • @eliaskoch5604
    @eliaskoch5604 8 дней назад

    if there is 45 dc and 0dc then is it the indoor bord faulty and if it 10dc then 0dc is it the outdoor bord faulty ????

    • @boulmo9167
      @boulmo9167 7 дней назад

      It depend If that happen then you probably have to check indoor and outdoor board check the fuses it could be both board that’s bad but usually outdoor bad board are the common one

  • @michaelburns5680
    @michaelburns5680 8 дней назад

    Not sure if you have one but the most valuable piece of hardware you can have for checking Daikin residential equipment is the Daikin Transmission Checker (I don’t even know if they sell it anymore). It hooks up to 1,2,3 terminals and it tells you all the indoor data such as sensors and requested capacity sent to the outdoor. On the outdoor side it tells you sensors, outdoor fan data, compressor hz etc. If it doesn’t pick up the indoor or outdoor on the transmission checker it generally sends you in the right direction to go checking.

    • @maracservices
      @maracservices 6 дней назад

      Interesting, I can’t say I’ve seen one of those. Sounds pretty handy!

  • @rhyscarnell137
    @rhyscarnell137 8 дней назад

    How do u get the fan barrel out of those Fujitsu models

    • @maracservices
      @maracservices 7 дней назад

      The evaporator needs to slide up to get good access to everything. You don’t need to remove the board on the side which is good.

  • @CapitalCoastHVAC
    @CapitalCoastHVAC 8 дней назад

    Thats an old pup.

  • @maxd4968
    @maxd4968 8 дней назад

    My Daikin sounds like that and has for well over a decade. Still works fine tho so we never fixed it

    • @maracservices
      @maracservices 8 дней назад

      @@maxd4968 this actually still worked fine as well. It was just annoying the customer to much.

    • @AussieHVAC
      @AussieHVAC 8 дней назад

      @@maracservices Nice work Mitch, it’s an easy one for a rookie to trip up on as it can sound like it requires a new fan motor when all they need is a good clean out . The cleaning bags and portable pressure cleaner have been game changers since coming on the market. Unlike the old days of pumping unit down, disconnect, remove from wall & clean out etc. 👍❄️

    • @AussieHVAC
      @AussieHVAC 8 дней назад

      That would do my head in listening to that frequency, sounds like an A/C in a computer server room that’s been running 24/7 not stop .

    • @maxd4968
      @maxd4968 8 дней назад

      @@AussieHVAC it dose run a lot and we are just so numb to it now we don’t even notice it.

    • @AussieHVAC
      @AussieHVAC 8 дней назад

      @@maxd4968 Yeah your probably right, Im like that with the noise our kids make as it just blends into the background 😂

  • @GeneralAvitation
    @GeneralAvitation 8 дней назад

    Very unhappy bearing i hear there 🤔

    • @maracservices
      @maracservices 8 дней назад

      @@GeneralAvitation yeah mate it was screaming out to be replaced

    • @GeneralAvitation
      @GeneralAvitation 8 дней назад

      @@maracservices poor old thing 🤣

  • @robalexander7348
    @robalexander7348 8 дней назад

    Explained well Mitch, so handy for the boys entering into the A/C game 👍

  • @anothaparson
    @anothaparson 9 дней назад

    ruclips.net/video/4WCnz34SiX8/видео.html

  • @Optuss
    @Optuss 9 дней назад

    Thanks Mitch. What would you expect to see for the low/high readings with bad boards?

  • @kamalhamdi6739
    @kamalhamdi6739 9 дней назад

    شكرا على المعلومات القيمة والشروحات خالد من المغرب الدار البيضاء متعلم مبتدىء

  • @user-og6hm2fv4n
    @user-og6hm2fv4n 9 дней назад

    Really liked this video! Very informative. Thank you Mitch!

  • @boldizsarnovak9037
    @boldizsarnovak9037 9 дней назад

    Really informative video! Thank you and keep up the good work!

  • @user-gk2ck4pr4g
    @user-gk2ck4pr4g 9 дней назад

    It's a very easy-to-understand explanation. There are so many types of multimeters. If there is a particularly recommended multimeter, I would like to see that video someday.

    • @craigladewig3158
      @craigladewig3158 9 дней назад

      Cant go wrong with a Fluke - Costly but well worth it, you could be risking your life using a cheap tester

    • @maracservices
      @maracservices 6 дней назад

      I recommend the fluke kit that’s designed for hvac. It comes with the multimeter you see in this video and another one that can measure amps. Cheers mate

  • @technicsortechniques6373
    @technicsortechniques6373 9 дней назад

    appareil photo e5 mechanical compressor lock possible to turn off the device is closed electrical switch in off mode in more than 6 hours after turning on your device it was working. 

  • @mazayamazayanadira6862
    @mazayamazayanadira6862 9 дней назад

    Im 🙏from indonesia teknical mate, Good job mate❤😊