- Видео 111
- Просмотров 859 743
Working Man🛠️Ron Doyle
Добавлен 11 мар 2013
Electrician and Home Improvement Contractor
T-770 Bobcat 100 hr. review & operating cost to rent one🤔
Edited by YouCut:app.youcut.net/BestEditor
The untalked about expenses of rental equipment. What you can expect to pay for on your next project.
Reviewing a machine and my experience renting a Bobcat T-770 track loader from Equipment share of Seafood Delaware.
I hope you liked the video 👍 If you did , please comment and subscrib. Until the next time stay safe and God bless you all!
The untalked about expenses of rental equipment. What you can expect to pay for on your next project.
Reviewing a machine and my experience renting a Bobcat T-770 track loader from Equipment share of Seafood Delaware.
I hope you liked the video 👍 If you did , please comment and subscrib. Until the next time stay safe and God bless you all!
Просмотров: 228
Видео
Blind spots on a Bobcat T-770 (installing a rear view mirror)
Просмотров 5714 дней назад
Edited by YouCut:app.youcut.net/BestEditor
Just-in-case track tension 🔧 for Vermeer CTX-100 &160
Просмотров 1662 месяца назад
For those Just-in-case situations, you need to get your tracks back on and your nowhere near your main tool box. This wrench is handy in a pinch. This wrench will fit the Vermeer CTX -100 and the CTX -160 in the loader's hydraulic safety holding device. I hope you liked the helpful tip. If you did? Please comment and crash that like button 👍 .If you liked the video, please consider subscribing ...
Hidden tool storage on a Vermeer CTX-160🧐
Просмотров 1092 месяца назад
Hidden tool storage for those just in case moments of needed 🛠️ repairs ⚙️. If you need a more indepth of measurements on making one of these tool boxes for yourself? Please comment below! If i get enough replies, I'll shoot another video of making another one. Thanks for watching 👍. You'll have a blessed day 🙏
Vermeer CTX -160 getting tracks replaced after 347Hrs. of use ⚙️(total cost)🤮
Просмотров 7032 месяца назад
I busted a Camso track at 346.5 hours of use. Total track, sprocket and lug nuts replacement on this 2021 Vermeer CTX -160 mini-skid steer machine. Cost of replacement to do so. I hope this video is helpful and informative to you'll. If you'll experienced early track failure, please comment below to inform others of your experiences no matter what machine you own! Let us know. Thank you for wat...
Camso Track failure on a Vermeer CTX-160 🧐
Просмотров 2673 месяца назад
Early track failure on a Vermeer CTX-160 🧐! Is 373.5 hours to early for track failure??? I think so!!! Stay tuned for part two- Track & sprocket ⚙️ replacement. It will be an informative video! You not gonna want to miss it! What do you all think? Please comment below what is average track life for the brand and what machine your using them on? Looking forward to reading the comment section. Th...
How to clean a Quadra-Fire pellet stove 🧐
Просмотров 4096 месяцев назад
How to clean a Quadra-Fire pellet stove 🧐
Delmarva Model Railroad club's 🚂 open house 2024
Просмотров 1536 месяцев назад
This video is for the model train kid in👉🏻 you 👈🏻 A must see attraction on the Eastern Shore of Delaware. This event is scheduled four weeks out of the year, so don't hesitate to look up Delmarva Model Railroad club 🚂 on Facebook It's housed at the old Delmar firehouse in Delmar Delaware. Free to the general public. Donations are accepted!!! But not required. If you liked this video 🤔 please cr...
The Best way 🤔 to pull Mule tape into a conduit raceway.
Просмотров 4,6 тыс.6 месяцев назад
The Best way to pull mule tape into a conduit raceway. No matter the size 🤔 This seams to be the fastest way. Master electrician Ron Doyle here on Maryland's Eastern Shore will show you how to speed up your production time in getting it done. This very simple trick of using plastic shopping bags from your local grocery store a large shop vacuum to, suck it up buttercup 🤠 lol.... In this video I...
Footer preparations for an 🤔 easy conduit riser installation
Просмотров 3567 месяцев назад
In a perfect world 🤔Builders, Mason's and Electrician would know where the Meter sockets would land on a house that hasn't been built yet. Well we're not in that world, but I wished we were! If your planning on building a house and have a sight plan drawn up. Talk to one of the utility companies sight engineer's to come up with a game plan on which side to bring the power in on. Then talk to th...
Firewood measure sticks🤠repurposed broken fish sticks
Просмотров 1427 месяцев назад
Firewood measure sticks🤠repurposed broken fish sticks
Greenlee (Fish sticks)& Klein tools accessory kits proprietary🤔
Просмотров 2237 месяцев назад
Greenlee (Fish sticks)& Klein tools accessory kits proprietary🤔
C.I.D. Attachments Skid-steer bucket (fixing a problem)
Просмотров 1908 месяцев назад
C.I.D. Attachments Skid-steer bucket (fixing a problem)
Milwaukee 52" high capacity work bench 🤔 I bought it cheap!
Просмотров 4259 месяцев назад
Milwaukee 52" high capacity work bench 🤔 I bought it cheap!
36" Bobcat Brand Industrial grapple bucket 🐂 is a Beast!
Просмотров 50710 месяцев назад
36" Bobcat Brand Industrial grapple bucket 🐂 is a Beast!
Electricians choice for Best exterior-in-use electricial boxes 🤔
Просмотров 4,8 тыс.Год назад
Electricians choice for Best exterior-in-use electricial boxes 🤔
Modifications on a Titian stump bucket & put it in action 🤔
Просмотров 935Год назад
Modifications on a Titian stump bucket & put it in action 🤔
Problem🧐with 14/2 NM Southwire Romex Brand Simpull Wire
Просмотров 1,9 тыс.Год назад
Problem🧐with 14/2 NM Southwire Romex Brand Simpull Wire
My Electrical inspection Failed🤔Box set-back issues!
Просмотров 1,6 тыс.Год назад
My Electrical inspection Failed🤔Box set-back issues!
Installing Service disconnect on vinyl siding for HVAC condenser unit🤔
Просмотров 70 тыс.Год назад
Installing Service disconnect on vinyl siding for HVAC condenser unit🤔
Vanity lights 💡💡💡 relocating to center!
Просмотров 10 тыс.Год назад
Vanity lights 💡💡💡 relocating to center!
Klein tools 17qt. Tradesman cooler Review & Lifetime Warranty 🤔
Просмотров 4 тыс.Год назад
Klein tools 17qt. Tradesman cooler Review & Lifetime Warranty 🤔
How to identify 🤔 clear (translucent) wire on pendant💡lighting
Просмотров 2,8 тыс.Год назад
How to identify 🤔 clear (translucent) wire on pendant💡lighting
Fellowship at the Furnace Featuring Easton Made 🪓 Log splitters
Просмотров 2,2 тыс.Год назад
Fellowship at the Furnace Featuring Easton Made 🪓 Log splitters
Fellowship at the Furnace (Brad's 1st open house)
Просмотров 419Год назад
Fellowship at the Furnace (Brad's 1st open house)
Adding Old-work🤔 recessed lighting in a drywall covered ceiling
Просмотров 894Год назад
Adding Old-work🤔 recessed lighting in a drywall covered ceiling
Range, refrigerator and the kitchen sink all in one appliance 🤔
Просмотров 680Год назад
Range, refrigerator and the kitchen sink all in one appliance 🤔
Defective 🤔 Square D 200 amp main breaker What ever happened to (Quality Control)?
Просмотров 4,7 тыс.Год назад
Defective 🤔 Square D 200 amp main breaker What ever happened to (Quality Control)?
Sheet rock covered boxes🧐tips & tricks to find and fix them
Просмотров 618Год назад
Sheet rock covered boxes🧐tips & tricks to find and fix them
One of the best video and presentations on RUclips….definitely subscribed
Thanks for watching and comment. I really appreciate it 🤠
Thank you for a thorough, well paced tutorial with lots of electrician's tips. Also, very thoughtful of you to record the video at a higher speed. This can save the viewer valuable time especially when they re viewing several of these videos (because they're learning). The viewer can reduce the playback speed (via Settings) if they find the speed too fast.
Thanks for watching and the compliment. I really appreciate it Steve.
Did he check for afci breakers in all dwelling areas?????
Thanks for watching and commenting on the video. Yes, he did. No stones left unturned. He was a great inspector.
Have to be 100 feet from a pop machine
Very informative video, could not for the life of me figure out how to get the cover down so thank you for makin’ this
A shame about the clamp on meter. Fluke has replaced a tester/meter or two for me but they don't like doing it. Tools are an investment, but now we are in a disposable society. Now I keep cheap knock off meters around for spares.. They make you do it.
"within 18"of the wall
Hi Ron! I just moved into my new place and noticed that these lights weren’t turning on. Turns out, there was just straight up no light bulb inside 😂. I was able to get the cover down without any sort of thin blade, but your advice on where to press helped a lot. Thanks so much!
Are you related to the “hawk toah” girl? 🤣
Get a friend with a 3D printer. Could have fixed you up for pennies.
That harbor breeze armitage iii
Running my wire is the easy part, the thing I'm not understanding is how you mount the box using the spacers, if you run the bottom screws in, than take them out to put in a spacer, doesn't the spacer just push the siding, if the screw made the hole, and the screw fits in the spacer, how wouldn't the spacer just push the siding back against the wood, don't you need to enlarge the screw holes in the vinyl for the spacer to fit in. I don't see how the siding could move back and forth like you said, how could it do this with the top screw in a hole that it made, the hole is not slotted for the vinyl to move left and right, other than that, I don't see the benifit of a mounting blick, I don’t see how they would prevent water from running back behind the vinyl without caulking the top and sides.
Thanks for watching and commenting. Great questions. The main purpose of the video was to express the importance of mounting a service disconnect securely to a wall. The spacers aid in the requirements of securely mounted disconnects. The vinyl sides can still expand on the right and left sides of a securely mounted disconnect if done properly.
“National Electrical Code”, not National electric code!😅
When wiring the back of the range, what would happen if you reverse the Black and Red wires?
Thanks for watching and commenting. That's a good question. If the range is listed for 240 volt single phase? It won't matter if the red and black are switched. Red to black and black to red. They are both 120 volt to ground each. And 240 volt hot to hot .
Yo! Just keep doing the dam thing. Good job.
I learned some great tips from you today. Thank you for sharing your expert knowledge.
best video on wiring and placement of a disconnect. Many thanks!
Cap
You can just order a key for like $6 🤣
Thanks for watching and commenting. 🤔 I thought so too. Milwaukee Rep told me the number on the key was not the key cut. I would have to order the whole cylinder with keys for the fix. I had a hunch they were in there.
Bought my scaffolding from Harbor Freight, and leveling jacks from Tractor Supply - Metaltech Set of Hollow Levelling Jacks on Base Plate, M-MBSJP24HK4. You can also ratchet straps to reduce spreading at bottom. I need to figure at a DIY safety rail for the HF Franklin set.
Am I seeing CPVC? That's surprising for a 2-year-old house.
Thanks for watching and commenting. I would say 99% of all the residual houses on the eastern shore have cpvc piping. And the houses that don't are converting to it over time.
@@workingmanrondoyle3287 Really?? My 1994 house is all CPVC. And that stuff is BRITTLE. It's fine as long as I don't touch it. But kid gloves are required when mods are needed. I thought EVERYONE was moving from CPVC, to PEX. Especially for new construction.
Pex is making a comeback around here but not as popular as cpvc .
Yes, really. This area had two large home manufacturer years back and Pex is all they used, hooked to a Man-o-block valve system. Over time the these systems failed causing lots of mixed feelings about Pex piping causing damages. Most plumbers in this area don't like or use Pex now.
How does the siding move after putting 3 screws in it? I guess I dont get it. Serious question.
Thanks for watching and commenting. Great question. Vinyl siding expands as it gets warmer throughout the heat of the day. That's why siding manufacturer's require it to be nailed loose so as it can expand through heat cycles without buckling. Siding blocks are made and recommend for all exterior penetration. But in a lot of new construction, scheduling different contractors on one job to work together is difficult. That's why a lot of people have resorted to direct fixture placement on vinyl siding covered walls. If done correctly, will not cause problems. If a service disconnect, one (fixture) is mounted tightly on a wall, allowing the ends to float freely is a must to prevent buckling of the siding.
The 2023 NEC no longer requires island or peninsula receptacles, and installing 1 could open you up to liability if someone hooks a cord and gets hurt. They now want counter top rated receptacles where no wall exists. And no, I'm not providing a reference number.
Thanks for watching and commenting. The 2023 code only requires, ( a wire in a box under the cabin for future provisions). No outlets required.
Well done
Thanks for that. I gotta check mine now. I gotta about the same amount of hours
I just ordered one. She ain't gonna get beat on to bad so hoping shel hold up.
So it looks to me the sprockets wear caused excessive damage to the track then the bolts/nuts...wouldn't it make sense say to replace the sprockets say at 150 to 200 hours to prolong life of the other components? I'm guessing the sprockets get red hot causing the rubber to melt and release the metal component. How long did it take to get to 347 hours use? Are you hard on the machine? Would do you budget for maintenance in your hourly rates...I'm guessing this adds $10 per hour alone. Still looks like the machine will do the work of ten men easy...lol Is it the speed going forward thats causing shit to get hot and wear? Can you slow the speed down to help? I see what ya mean..the sprocket teeth need to be longer.
Hey Mark. Thanks for watching and commenting. Great questions. Those hours were put on the Vermeer in a 3 year period of time. I'm moderately hard on the machine. Sprockets never get hot, way to slow for that to happen at 4 mph. It's a true turtle but will outwork 5+ guys all day long. I figured up the track and sprocket maintenance to be $13.00 per hour. That's not counting idler's and undercarriage. I'll be doing an updated 400 hour review this you.
Can I T out of one of my smoke alarms or does it need to be in series
Hey Bill, thanks for watching and commenting. Yes, you can absolutely tee off of a smoke for a sprinkler relay or smoke, carbon monoxide detector. Just make sure your not going over the wire count listed in the back of the box.
@@workingmanrondoyle3287 thank you so much I’m a owner builder and the fire chief requires everything connect and my fire sprinkler installer didn’t even know how to do it. I think you are the only one that does. Thanks again for sharing your knowledge.
Seems like a lot of work for such low hours. Perhaps the weight of this machine exceeds the capacity for this track system.
Thanks for watching and commenting. You maybe right about that. Going off of what other owners with the same machine have said, lots of early track failure. I do believe the drive sprockets should have been designed better.
Just doing some wiring the other day and noticed this. Thought I had a bad roll, I guess not. No more Southwire for me.
Great video 👍🇦🇺
Very cool tool. I wish i knew how to weld
Great review! Do you know if they have fixed the issues in manufacturing now in 2024? Did you add the lights and the side step? Whats the side step for? Thx
Thanks for watching and commenting. I've only had a few people people reply with the same problem of the loader arm rubbing issues. I added the five work lights and steps. The steps are for temporary ballist weight. (Humans) lol.. I've only had to use them once to lifting a car from a ditch.
This is a guy that genuinely cares about his workmanship. Its more then chasing a paycheck. He’s thinking of consequences(good and bad) that others will have to deal with years down the road, that are made by good or bad work done today.
Curious- can the fan cover be removed for cleaning?
Thanks for watching and commenting. Yes, the fan can be removed from cleaning fairly easily by removing the inner fan plate. Sometimes the plate is secured by one ¼" hex headed screw. I hope that helps you.
Beautiful, wonderful , amazing job 🙏🌹✌️
Very nice job! I learned alot from this Ron. I have the same machine. Thanks
Thank you for all the detail in the video!!
What would cause molding to settle around the edge of ceiling where this is mounted against?
Thanks for watching and commenting. For as many years as I've been replacing bathroom exhaust fans, I've not seen mold growth around them.
This was so helpful! Thank you!!
nice!
Thank you!
I am a cabinet installer and also a handyman that does projects like this. You are the most conciencious electrician I have seen. Not only did you care for the electrical installation but also the cuts in the cabinet. Can't tell you how many times I have had to go in and reskin a cabinet back or side panel or floor because some careless plumber or electrician didn't care about anything but their installation. I have also seen bad cabinet installers do poor cuts in cabinets to allow for existing pipes or outlets so I know it goes both ways. I appreciate your craftsmanship. Well done on the video too. NEC 2023 actually now does not require an outlet in peninsulas or islands. They are also suggesting installing pop-ups in countertops if customer still wants an outlet. They have seen enough kids and adults walk by a plugged in hot plate or coffee pot, catch the cord and pull the small appliance down resulting in burns.
Thanks for watching and commenting. I appreciate the compliment. Your right about the code changes for 2023. Maryland is stuck on the 2017 codes lol...
job well done Ron ! Thanks for the video! You may want to spray some WD40 on the plastic bags before. See the difference.
I got rid of the pins that join the ladder sections... they are 5/16" pins in 1/2" holes, that sloppiness adds a lot of the shakiness, which compounds as you add levels. I use 1/2" x 2-1/2" bolts with flat washers and locknuts. Yeah, it takes a bit longer to set up the scaffolding, but it's well worth the added stability, and it eliminates the issue of someone tampering with the pins. That, along with using ratchet tie down straps in the X pattern on the sides, makes for a very stable setup.
Thanks for watching and commenting Henry. Great ideas for gaining stability 👍 Thanks for the tips.
Can I get your information to contact you I have some questions I’m a electrician
Hey Hector, you could commit here so others can chime in. Or message me through email: rondoyleatdms@gmail.com
Very helpful video 👍
Saw that in Washington state.
One very important thing to note regarding threads. 8-32 is not "eight thirtyseconds". It is a #8 screw with 32 threads per inch
Stay Safe. Thank You for the tips!