4 head PFE-500/PFG-600 Lid Spring Replacement
This is an updated version of our original lid spring video with a few minor changes. One thing this new video shows is loading the new black lid spring.
The lid spring is the component of the lid assembly in 4-Head pressure fryers that allow the lid to stay up when open. If your pressure fryer lid won't stay up or stays half way up then it is time to replace your lid spring.
In this video you will learn the easy steps involved in replacing the lid spring. Please ensure that you use the required lid spring removal tool P/N 14960 that you can purchase from your local Henny Penny distributor or any authorized parts retail partner.
To find your local HP distributor please click here: www.hennyp...
Просмотров: 169

Видео

OGA/OEA 320 Series Actuator Update
Просмотров 8414 дней назад
This video describes the differences in the new actuator compered to the previous offering as well as what to look for when installing it.
Flex Fusion Comi Oven- No Gas -Troubleshooting
Просмотров 3012 месяца назад
Flex Fusion Comi Oven- No Gas -Troubleshooting
Flex Fusion Gas Co2 Adjustment Procedure
Просмотров 2805 месяцев назад
This video shows how to adjust the gas valve settings to get the Co2 Analysis correctly set.
Co2 Gas Analysis Process
Просмотров 2625 месяцев назад
This video shows how to do the gas flue analysis that is performed during a start-up of new equipment, annual inspection and preplacement of a gas valve.
Evolution Elite Gas Fryer (EEG) Gen 4 Selector Valve Info and Replacement
Просмотров 2,2 тыс.Год назад
In this video we explain a few differences with the new Generation 4 selector valve motor compared to the previous gen 3 motor and also the replacement procedure for units in the field. To find replacement parts for this piece of equipment or operational information, please visit www.hennypennyhelp.com For further assistance please contact your local Henny Penny distributor www.hennypenny.com/s...
E-20D How to clean the flame sensor
Просмотров 2,3 тыс.Год назад
In this video we show how to clean the flame sensor and pilot assembly in the event that you don't have available access to a new pilot assembly. This can sometimes get you by and get the customer up and running until you can get the necessary parts.
Auto Translate YouTube 00m 28s
Просмотров 1,1 тыс.Год назад
How to use the Auto-Translate Feature on RUclips videos on your laptop in 28 seconds! No Sound.
How to watch our videos in any language on your smart phone! Auto Translate Feature
Просмотров 1,5 тыс.Год назад
This video shows how to use the Auto-translate feature within RUclips to watch our videos in other languages on your smart phone. If the CC is greyed out on a video then the Auto-translate feature is not available. Este video muestra como activar subtitulos en otros idiomas.
How to view the pressure in the fry pot on Velocity fryer in the info screen
Просмотров 318Год назад
Since the Velocity fryer doesn't have an external pressure gauge, this video shows you how you can see the pressure inside the fry pot when cooking, by checking it in the info screen. Also, learn a hidden tip to lock that screen on for a longer period of viewing. To find replacement parts for this piece of equipment, please visit www.hennypennyhelp.com For further assistance please contact your...
Evolution Elite- How to check the Drain Pan Switch in the Control Panel!
Просмотров 1,6 тыс.Год назад
Checking the drain pan switch can be easy when using the control panel. In this video, Senior Technical Trainer Scott Hughes shows us how to use the control panel to check the drain pan switch. This can be useful before even getting out your multi-meter. A reason you might need to use this feature is if the customer is seeing a message on the screen that keeps telling them to change their filte...
LVG/EEG- How to Check Gas Pressure
Просмотров 3 тыс.Год назад
Knowing where to check gas pressure on the different model fryers can be difficult to find. In this video we show where to check incoming (static) gas supply pressure and also outgoing manifold (dynamic) pressure. (Static) Supply Pressure- LVG/EEG Models Nat Gas- 7"-10" IWC Lp Gas- 10" IWC (Dynamic) Outgoing Manifold Pressure- LVG/EEG Models Nat Gas- 3.5" IWC LP Gas- 10" IWC To find replacement...
How to Troubleshoot the Velocity E 82 (selector valve failure) Error Code
Просмотров 1,5 тыс.Год назад
When it comes to troubleshooting the E-82 error, there are a several things you need to know to make your troubleshooting easier and more efficient. In this video Technical Trainer Randall Eby shows us 2 different ways to troubleshoot the error code as well as an explanation of logic behind the error code. To find replacement parts for this piece of equipment, please visit www.hennypennyhelp.co...
2 Ways to Check Microamps on Henny Penny gas fryers!
Просмотров 3,2 тыс.Год назад
Depending on what Henny Penny gas model fryer you are working on, it can be difficult to check microamps depending on component location. So, in this video we show 2 different methods of checking microamps so that you can decide which is easiest for the model you're working To find replacement parts for this piece of equipment, please visit www.hennypennyhelp.com For further assistance please c...
Troubleshooting the E-83 (pressure too high) error code on LVG and EEG fryers.
Просмотров 5 тыс.Год назад
Troubleshooting the E-83 error code can be tricky. Knowing which direction to go in your troubleshooting and the components involved can save you lots of precious time. In this video, Technical Trainer Randall Eby shows the 2 different methods to troubleshooting and the logic behind the error code. To find replacement parts for this piece of equipment, please visit www.hennypennyhelp.com For fu...
Troubleshooting the E-60 (communication failure) error code on LOV and Evolution Elite fryers.
Просмотров 6 тыс.Год назад
Troubleshooting the E-60 (communication failure) error code on LOV and Evolution Elite fryers.
Filter Pump Motor- High Voltage to Low Voltage Conversion
Просмотров 2,3 тыс.Год назад
Filter Pump Motor- High Voltage to Low Voltage Conversion
How to Check Drain Switch without using a Multimeter!!
Просмотров 2,5 тыс.2 года назад
How to Check Drain Switch without using a Multimeter!!
How to Check Error Code History!!
Просмотров 1,7 тыс.2 года назад
How to Check Error Code History!!
Easy Lid Gasket Install Tips for the 4 Head Pressure Fryer
Просмотров 1,1 тыс.2 года назад
Easy Lid Gasket Install Tips for the 4 Head Pressure Fryer
How to separate the lid and crossarm for a bent lid latch pin.
Просмотров 2 тыс.2 года назад
How to separate the lid and crossarm for a bent lid latch pin.
How to test components in Tech Mode
Просмотров 6 тыс.2 года назад
How to test components in Tech Mode
Learn how to troubleshoot W-7 & E -27 Low Amps on 4HD PFE 500 Hybrid Control
Просмотров 3,3 тыс.2 года назад
Learn how to troubleshoot W-7 & E -27 Low Amps on 4HD PFE 500 Hybrid Control
Henny Penny Help Part # Search
Просмотров 2,4 тыс.2 года назад
Henny Penny Help Part # Search
How to Troubleshoot W-1 Low Voltage Error Code - Henny Penny Chick-Fil-A Fryers
Просмотров 2,2 тыс.2 года назад
How to Troubleshoot W-1 Low Voltage Error Code - Henny Penny Chick-Fil-A Fryers
Henny Penny 900 Series Door Gasket Replacement - Henny Penny Holding Cabinets
Просмотров 9232 года назад
Henny Penny 900 Series Door Gasket Replacement - Henny Penny Holding Cabinets
3 Simple Relay Board Test Under 3 minutes - Henny Penny FlexFusion Combi Ovens
Просмотров 4942 года назад
3 Simple Relay Board Test Under 3 minutes - Henny Penny FlexFusion Combi Ovens
4 Status Menus for EASY Troubleshooting in 4 minutes - Henny Penny FlexFusion Combi Ovens
Просмотров 4382 года назад
4 Status Menus for EASY Troubleshooting in 4 minutes - Henny Penny FlexFusion Combi Ovens
Hybrid Control Setup - Henny Penny Chick-Fil-A Fryers
Просмотров 1,4 тыс.2 года назад
Hybrid Control Setup - Henny Penny Chick-Fil-A Fryers
Randall Eby Welcome to the Channel
Просмотров 2,6 тыс.2 года назад
Randall Eby Welcome to the Channel

Комментарии

  • @z.tworld2522
    @z.tworld2522 День назад

    Very nice thanks

  • @jalalammar2917
    @jalalammar2917 6 дней назад

    0:24 hi,i need all code henny penny 410/420 ckick flea Gray board Thank you .

  • @jesseyoungberg5533
    @jesseyoungberg5533 12 дней назад

    Very well done and clearly explained video 👏

  • @gonzales2901
    @gonzales2901 26 дней назад

    What if the error happens as they’re using the fryer at random points did the oil get too low?

    • @HennyPennyService
      @HennyPennyService 14 дней назад

      HI @gonzales2901 if this is on a gas fryer, we can see this error happen more often throughout the day if the oil is low. The unit heats for several minutes, but never sees a temp rise at the probe because the oil is not touching the temp probe. If this is on an electric fryer and you get intermittent E-22 errors through the day, then check if power cords are plugged in all the way or unplugged. LOVs in some countries pull voltage to the controls through a separate cord. Even though the control is working, the large 3 phase power cord may not be making connection or plugged in. Hope this helps.

  • @poludnik
    @poludnik 27 дней назад

    Hi guys, do you have any personal experience with this procedure? How much time does it take in real conditions? Is it work for one person? Thanks for sharing your experience.

    • @HennyPennyService
      @HennyPennyService 14 дней назад

      It's a good question. Using the procedure in this video, many techs who do this solo. The method used in this video was actually a tip we got from a tech in Australia to perform this solo. If you have full access to the fryer, this is about 1 hour job (plus travel). Plan on a little longer if it is the first time you do this procedure though. Hopefully that helps!

  • @jabroski69
    @jabroski69 28 дней назад

    Gtfobeen cleaning flame sensors with sandpaper for years

  • @jamesthegrower2.0
    @jamesthegrower2.0 Месяц назад

    I can change these without taking the lid off and turning it upside down , don't have time for all that lol i also don't take the side screws out all the way saves a bunch of trouble trying to get em back in

  • @jamesthegrower2.0
    @jamesthegrower2.0 Месяц назад

    What if you clean everything solenoid steam box drain tube and the tube going across the back, and it's still slowly to release pressure? I even took the steam box apart and cleaned the tube inside with the holes in it. It's a henny penny computron 600 . I work for a grocery store food market( we have 17 stores )and we have henny penny fryers mainly in our deli's ,I'm a tech also. This is on a fryer I was working on yesterday

    • @HennyPennyService
      @HennyPennyService 14 дней назад

      Good question. Depending on the cook cycle and the amount of moisture in the product, you should have anywhere between 30 seconds and one minute to release pressure if the plumbing from the frypot through to the condensation box is fully open to its 1/2" diameter. If this is taking longer, then the tubing or solenoid valve partially obstructed and not open to its full 1/2" diameter.

  • @JayJay-lt3vh
    @JayJay-lt3vh Месяц назад

    Amazing job mate

  • @islamdubai6922
    @islamdubai6922 Месяц назад

    Hi sir i need mantinac guyz

  • @AndrewDaley-zt8kc
    @AndrewDaley-zt8kc 2 месяца назад

    Thanks Randall! This video absolutely saved one of my techs on a weekend call! love the resources you guys have been pumping out.

  • @Akronkangaroo
    @Akronkangaroo 2 месяца назад

    Why does that fuse on the electric one have to be at the bottom like that?😂

  • @serajahmed6301
    @serajahmed6301 2 месяца назад

  • @serajahmed6301
    @serajahmed6301 2 месяца назад

  • @CanadianBrewingChannel
    @CanadianBrewingChannel 2 месяца назад

    You guys make amazing troubleshooting videos! Also love your training facility. Have not been to Eaton for a while.

    • @HennyPennyService
      @HennyPennyService 2 месяца назад

      Awesome! Thank you! We look forward to having you again!

  • @LuisArenas-ey4he
    @LuisArenas-ey4he 2 месяца назад

    Buenas tardes por favor si es posible en español también muchas grcias 4:22

  • @gilbertcristobal5463
    @gilbertcristobal5463 2 месяца назад

    How do you change product

  • @justinodias7266
    @justinodias7266 3 месяца назад

    como ligar este motor para dar no sendo anti horário necessário para a esquerda.

  • @kevin24k32
    @kevin24k32 3 месяца назад

    Also is you change out for refurbished processor and you don’t have a selector motor you can go into tech mode and go to T4 and if it says YES switch to NO

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 3 месяца назад

    What about the middle one with the oil pump in front of it.

  • @Goldstacker1972-kp2bh
    @Goldstacker1972-kp2bh 3 месяца назад

    What about the middle one where the pump sits Do you have to take anything else apart to get it out with it being so close to the pump?

  • @EightysMinions
    @EightysMinions 4 месяца назад

    just dealt with this today after watching this video. Remove the gas line secured it back on correctly - restarted - and all three of them ignited and it worked great The gas line was not open all the way. so, by saying to remove the gas line, I was able to notice that. Just a manager, so it helps to be able to to give a heads up on these errors before my repairman comes. Ty

  • @atputhanathanshanmuganatha6050
    @atputhanathanshanmuganatha6050 5 месяцев назад

    All parts 3:37

  • @christ2694
    @christ2694 5 месяцев назад

    I experience that error lov 203 with pilot but still igniting..any advice

  • @Bassinkevinw83
    @Bassinkevinw83 5 месяцев назад

    Very helpful in changing out my lid assembly for the first time. Thanks for the video!

  • @savannaclaude4808
    @savannaclaude4808 5 месяцев назад

    'Promo SM' 😚

  • @sam009sam
    @sam009sam 6 месяцев назад

    But why we do that

  • @leediamond3120
    @leediamond3120 6 месяцев назад

    Thank you!

  • @mdzahid9633
    @mdzahid9633 6 месяцев назад

    If the Solenoid valve does not work, will the pressure fryer work?,,,sir plz reply 🙏

  • @mdzahid9633
    @mdzahid9633 6 месяцев назад

    Sir please reply,,, If the Solenoid valve does not work, will the pressure fryer work?

  • @michaelcaplinger5115
    @michaelcaplinger5115 6 месяцев назад

    It’s 4:00 on a Friday and this is what I’m about to dive into

  • @terranceburgess9170
    @terranceburgess9170 6 месяцев назад

    I changed the selector valve and calibrated fryer then I got E 82 D on all 3 fryers then a 93 A 24 volts tripped

  • @johnsanchez8029
    @johnsanchez8029 6 месяцев назад

    I had a weird issue yesterday. I had an e20d error on a vat. Both pilots were sparking but the only the right burner was struggling to come on. I did check orifice for obstruction and I also had the 3.5”WC. This was only happening a few times a day. Solenoid obviously works if left burner is lighting. Ignition module obviously works if there’s spark. Gas pressure reading indicates there’s obviously gas flow. What else could it be?

  • @smamas114
    @smamas114 6 месяцев назад

    Looking for e60 bmw error and found this 🤦‍♂️😂

  • @faisalfaisy9515
    @faisalfaisy9515 7 месяцев назад

    sir i need this tool what is the rate for it.. i am in saudi arabia... give me your whatsapp no

  • @ToddClattenburg
    @ToddClattenburg 7 месяцев назад

    great video. Thank you.

  • @Nandao_Vs
    @Nandao_Vs 7 месяцев назад

    Thanks for the valuable information!

  • @brandon5118
    @brandon5118 7 месяцев назад

    Easy money! 💵

  • @ashiqhussain9591
    @ashiqhussain9591 7 месяцев назад

    Hi can you help i have used 6 units CFA computer how to program them

  • @user-yw4sb3bb3o
    @user-yw4sb3bb3o 9 месяцев назад

    How to replace the start display. instead of henny penny scroll in the display, I would like to program my personal name scrolling in the display it is posible?

  • @davidflores5761
    @davidflores5761 9 месяцев назад

    Hello What might be the cause of my issue? Motor can't make spin the pump rollers are brand new. It's stuck. I already degrease and clean the pump. Help me, thanks!!!

  • @eddieeeeee7157
    @eddieeeeee7157 9 месяцев назад

    11221122 doesn’t work. Is there another code?

    • @Arvolash
      @Arvolash 7 месяцев назад

      I hope you found your answer already , but there’s two different tech/service menus

  • @hybrid98
    @hybrid98 10 месяцев назад

    Saved me a bunch of money! Thank you!

  • @fairplay8378
    @fairplay8378 10 месяцев назад

    What is a hi reading on the microamp reading? As another henny penny video says anything over .75 means the ignition control is at fault ?

  • @fairplay8378
    @fairplay8378 10 месяцев назад

    When measuring microamps what causes the the icm to go above the.75 ? What is the cause if this fault ? As I have swapped both controllers but still got around 3 instead of the .75 ? This was on a evolution 242 . Thanks

  • @ChaoticZim
    @ChaoticZim 10 месяцев назад

    For anyone struggling to get tension on the spring to remove it, make sure the bottom piece on the removal tool goes BEHIND the bottom of the spring.

  • @ashtonhawkins3546
    @ashtonhawkins3546 10 месяцев назад

    is there an installation video for the solenoid valve?

  • @user-vj6hy7wq7q
    @user-vj6hy7wq7q 11 месяцев назад

    ممكن فديو طريقه فتح برنامج بورده 8000اذا تم تغيير الباسورد

  • @rghtech30
    @rghtech30 Год назад

    Excellent point made on the potential insufficient gas volume issue, often there are significant dynamic pressure drops that are overlooked.

  • @JulianFigueroa-no2rx
    @JulianFigueroa-no2rx Год назад

    Good video