LVG/EEG- How to Check Gas Pressure

Поделиться
HTML-код
  • Опубликовано: 11 окт 2024
  • Knowing where to check gas pressure on the different model fryers can be difficult to find. In this video we show where to check incoming (static) gas supply pressure and also outgoing manifold (dynamic) pressure.
    (Static) Supply Pressure- LVG/EEG Models
    Nat Gas- 7"-10" IWC
    Lp Gas- 10" IWC
    (Dynamic) Outgoing Manifold Pressure- LVG/EEG Models
    Nat Gas- 3.5" IWC
    LP Gas- 10" IWC
    To find replacement parts for this piece of equipment, please visit www.hennypennyhelp.com
    For further assistance please contact your local Henny Penny distributor www.hennypenny... or our Technical Support team at tservices@hennypenny.com

Комментарии • 8

  • @rghtech30
    @rghtech30 Год назад +1

    Excellent point made on the potential insufficient gas volume issue, often there are significant dynamic pressure drops that are overlooked.

  • @ToddClattenburg
    @ToddClattenburg 10 месяцев назад

    great video. Thank you.

  • @يحيىمحمد-ش3ع2ج
    @يحيىمحمد-ش3ع2ج Год назад

    ممكن التواصل

    • @HennyPennyService
      @HennyPennyService  Год назад

      يرجى الاتصال بموزع Henny Penny المحلي للحصول على المساعدة المحلية. www.hennypenny.com/resources/distributor-service-locator/

  • @hugoperez-zd3pm
    @hugoperez-zd3pm 2 года назад

    Hi my name is Hugo Perez I work for @CFA at Kirby Unit # 01801 we always problem we E 10 the High limit I very happy if you have a Visio who to replaced it because pay to much money, thank you.

    • @HennyPennyService
      @HennyPennyService  Год назад

      Hi Hugo, this is a procedure we recommend to be performed by a trained and qualified technician. Please contact our tech support department at tservices@hennypenny.com for further assistance in preventing high limit damage.