Actually the accumulator is located after the condenser right and it's purpose is use to store excess liquid refrigerant...so then y the accumulator connection is given after the evaporator and at the outlet of the evaporator it will be vapour right??
After condenser is liquid reciver usually used fo storing refrigerant during pump down and during normal cycle it lets refrigerant in liquid state to pass to dryer. On suction before compressor Is accumulator it only let's refrigerant in vapor state enter into compressor, to prevent any damages to compressor.
The accumulator placed before the compressor, suction side of the compressor is connected to the accumulator , and it helps in two ways , 1. excess oil won't come to compressor 2.cooled liquid won't come to the compressor, if it is directly connected the compressor would die
good day sir... anu kaya probable cause n nwala ung oil at refregerant s AC nmin onboard..we already check the possible leak pro wala kmi makita..any suggestion guys..salamat
Sir hnd bumababa temp ng meat at fish kulang sa lamig pero ang veg ok nmn tpos wlang ice build up sa evaporator ung refrigerant is half level is it txv replace or adjust?? Or what other causes bkt d lumalamig ok nmn watertight doors sealed
@@leckyjake bale nung nalaman ko na d nag low temp ang reading at -2 at -3 lng ang meat at fish nag ice kunti ang evaporator then binanlawan ko mbuti aun hanggang -9 at -12 lng nag bago nmn kht kunti tpos pumapara na ung sa meat pag na reach nya ung -9 nkita ko pumara solenoid then again hanggang -9 pa din after
@@leckyjake nagsimula sya nung nag provision kmi 5 hours un nkapara ang pinara ko lng is liquid solenoid valve switch hnd ko na pinump down kc gnun dn nmn gngawa ko before ok nmn
napakahusay malinaw madaling intindihin at tamang tama lang ang boses sir maraming salamat at laging ingat sir. More power.
awesomem, i’m korean and apparentice engineer. keep up the good work bro.
Mr. Secretary grabi ka banggi itan sa technical ba.. recommend ko dha beh 😊😁😁
Thanks for such usefull video! Respect
Sir ..plz discuss about refrigeration back pressure valve and unloader valve
Hello boss, what is the reason our provision freezer breaker always trip? Just we finish clean this freezer cooler yesterday
you better do an insulation and continuity test on your compressor and evap fan motor
Kung electrical ka check mo compressor gumamit ka meager tester kung meron ka.. Pati fan motor evaporator tester mo kung grounded..
Very nice video thanks!
thanks
Actually the accumulator is located after the condenser right and it's purpose is use to store excess liquid refrigerant...so then y the accumulator connection is given after the evaporator and at the outlet of the evaporator it will be vapour right??
it is for the compressor oil that gets to the system
After condenser is liquid reciver usually used fo storing refrigerant during pump down and during normal cycle it lets refrigerant in liquid state to pass to dryer. On suction before compressor Is accumulator it only let's refrigerant in vapor state enter into compressor, to prevent any damages to compressor.
The accumulator placed before the compressor, suction side of the compressor is connected to the accumulator , and it helps in two ways ,
1. excess oil won't come to compressor
2.cooled liquid won't come to the compressor, if it is directly connected the compressor would die
Thank you for the usefull video sir
good day sir...
anu kaya probable cause n nwala ung oil at refregerant s AC nmin onboard..we already check the possible leak pro wala kmi makita..any suggestion guys..salamat
Sir can you please make video on how to do transformer changeover onboard. ??
sir paano po yung pag umandar po meron freon sa condenser tapos kapag pumara na or pump down wala po nakocollect na freon po?
Sir hnd bumababa temp ng meat at fish kulang sa lamig pero ang veg ok nmn tpos wlang ice build up sa evaporator ung refrigerant is half level is it txv replace or adjust?? Or what other causes bkt d lumalamig ok nmn watertight doors sealed
Ilan temp
@@leckyjake -12 fish -9 meat then hanggang jan lng po
@@leckyjake bale nung nalaman ko na d nag low temp ang reading at -2 at -3 lng ang meat at fish nag ice kunti ang evaporator then binanlawan ko mbuti aun hanggang -9 at -12 lng nag bago nmn kht kunti tpos pumapara na ung sa meat pag na reach nya ung -9 nkita ko pumara solenoid then again hanggang -9 pa din after
@@leckyjake nagsimula sya nung nag provision kmi 5 hours un nkapara ang pinara ko lng is liquid solenoid valve switch hnd ko na pinump down kc gnun dn nmn gngawa ko before ok nmn
Baka naman naka set ka ng ganyan sa thermostat mo na - 9? Pm mo pictures sa leckyjake fb page.
Fish room temp. Not reaching up to -18dig. Only up to -13dig. Please advise
Same situation here ..any advice
Sir lecky,, ano po ang nag pa trigger ng compressor para umandar? Salamat
Hello hvac technician din ako same lang tayo ng binabantayan child water
Leckyjake you too much
sir mechanical enguneer ka po ba ?
Pls make video for charging gas in reefer container
How to apply?
Sir Saan pwde kumuha ng training na ito
Ganda naman ng mga ginagawa mo sir
Thank you sir
Continuation, pls.
nice
Hai
👌👍👍💯
sir baka pwde proper procedure ng pag pump down.
salamat
Madali lang po ang mg pump down sir
Hindi ako naka subok ng mga ganyan