Nice simple easy explanation. Keep up the great videos. I wish RUclips was around when I was learning to become an electrician. Is a great reference point.
Hi. Many thanks, I shoot my videos at 7.30 in the morning all alone in my workshop so support is most welcome... wish my learners would watch them. All the best Gaz
👍. I used to have a 4.0 mm single earth wire that I attached to the draw tape first . This 4.0mm was then used to pull in the other cables to avoid putting to much strain on the draw tape and damage it . Keep up with the videos.
When I look back wish RUclips was out when i was learning about electrics it was all books then I'm retired spark now 65 love to keep the grey matter working tho great presentation
This is the standard installation practice in Europe usually with flexi conduit chased in the typical masonry walls. I believe its also mandatory in Ireland? It does make rewiring so much easier.
Greetings, I do enjoy looking at your video's. While this does apply to to the UK, I thought i would give you an idea of what they use here in the Philippines. Normal light circuit is single cables, NO CPC used, the use cable called THHN 2mm Sq. Stranded, you also can get solid core. Power outlets, Receptacles, Single wires, use CPC, cable called THHN 3.5mm Sq, Stranded, you also can get solid. Scary part is many power outlets do not have Earth (CPC), so only 2 pin sockets, but of course you also have 3 pin with CPC, a lot of it is based on the USA system, but using 230 volts, plus you also get a different plugs, some round European type and and some straight (USA Type), you can get global power outlets which will take any plug, there are very common. The light sockets, switches, power outlets us push in fittings, there is no screws. So you cut the wire to correct length and push in the socket, switch or whatever. One very good brand is Panasonic, but of course lots of cheap rubbish on market also. Basically no such thing as RCB or RCBO only circuit breaker, as you can imagine lots fires every year because of electrical wiring. Cheers.
Great video, thank you. One question; if the nearest neutral for the second light was in the CU, can you take the neutral to the neutral bar in the CU? E.g. if the second light was on the left of the CU.
Excellent video as usual. You make a throw-away comment at about 3 minutes in about not needing to use a draw line as the runs in this case are so short. But for longer runs do you have any tips about how to attach multiple singles to the draw line, without increasing the cross-sectional area or stiffness of the bunch (e.g. by using too many wraps of insulating tape) - maybe it's covered by another video which I haven't yet found ?
I have a young guy working with me 2 days a week for experience, he is doing his 2365 L3, sadly his college is pretty useless and I have had him watch your videos and he learns a lot more from your videos than at college!, the college teach him to pass exams but no actual work skills or real world scenarios. Do you teach your students to take the feed to switch rather than the ceiling rose? as its a good basis before going onto conduit.
Hi. Thanks for the kind words. New learners are taught the standard 3 plate loop in method for pvc/pvc wiring and conduit loop in method in conduit. However I have covered feeding the switch with all my learners as it is so common in industry hence the videos on it. Hope this helps Gaz
Another great tutorial. Can you get junction boxes that fit the conduit incase you were making a three plate connection to an LED batten? The only boxes I've seen don't seem to match the conduit. Kind Regards
@@GSHElectrical Thanks for the speedy reply. So how do you use conduit to protect a lighting circuit if you want to use anything other than a bulb holder which has the junction box integrated into the base?
Absolutely brilliant video Gaz. However, I’ve made a little rig board exactly like yours, but the only difference with mine is, is that I’ve started with a one way lighting circuit, extending another two circuit which is a two way circuit taking the feed from my original one way circuit and then terminate my cpcs into maintenance free connectors, but when I tested the circuits and flick the switches into opposite positions I don’t seem to get a on and off operation. I check to see if there’s any default wiring but all fine. I’m just a bit confuse in the sense that it’s all wired properly but not working on the strappers. Any ideas on how to approach this. Lincoln
why not pick up the live neutral from the first junction box by using a terminal block? If I understand the 18th correctly, creating a branch off the main spur would be allowed provided it would only feed one end point? It would certainly make wiring it up easier and you essentiallyalready do this with the neutral?
Enjoyed that totally different from the domestic cable wiring, but I can see why you don’t need the sheath protection because the conduit does that job. Could it not be wired with cables as this way seems a lot more work and fiddly or is the point to reduce No of cables at the lights etc. Also most importantly you did your send off too quickly at the end. It’s meant to go. I hope this video has been…….pause some help with a big thumb love that don’t lose it or sell it to anyone else that’s your signature. Cheers for another good explanation.
@@GSHElectrical thanks for the speedy reply Gaz. I would have definitely assumed there would be some labelling, would save testing the cables (if you were taking over the job at the point you get up to in this video for example and weren't able to see the cable runs etc.)
Are there any limitations for using singles in conduit for connecting together 2 outside flood lights on the same circuit. I know metal is best practice but I have not seen anywhere saying its absolute.
Will you show wiring 2 way switches in singles and emergency lights with switched fittings on same circuit and key switch,I get confused with singles,Great informative videos,Thanks.
I don't know if it's code in the UK to have to wire this way but it seems like you're wasting about 20% of your wire having to backtrack with your ground/CPC and your Hot/PermLine wire Again I don't know if it's code but making a junction inside the lighting box with your ground/CPC and your Hot/PL wire would save having to go down and back to the switch Like I said I don't know what code is in UK maybe they don't allow Junctions inside boxes that carry fixtures If you could clarify it would be greatly appreciated. Thank you. Also, I realize this video is 3 years old.
i'm a bit confused why you're putting a cpc down to the switch and then another one back up when theyre all connected. when youre using steel conduit as a cpc you dont put a piece of conduit going down and then another one going back up
Hi. You will have to hunt around to find a training provider that will allow you to sit the exam without training.... try a online training provider e-qualified.co.uk around £130 teach yourself at home package 👍then sit the exam. All the best Gaz
Is it permissible to use plastic conduit to supply outdoor lighting say floodlights? Is there anywhere in the regs that deals with outdoor light fittings?
+ryewashere_ Thank you for that, is it necessary to glue the fittings together? I am only asking because some videos I have seen seem to suggest that glue is not necessarily required which seems rather strange to me :)
why do u need a cpc in a switch. the box doesnt seem to be metallic. in india we only have L & N. CPC is given if the SB have sockets in them( yes we wire sockets and light switches together). what function does the CPC have in the switch.
Hi. The cpc is at the switch in case it is replaced with a metal one therefore making it an exposed conductive part. ruclips.net/video/o72z_p8FIBQ/видео.html All the best and thanks for commenting and watching GSH Electrical
Hi. The exam question is what size cable as a minimum do you wire lights when they are installed in conduit answer 1.5mm2. The reasons for this I explained in my video. 👍GSH Electrical
Great job very clear
Thanks for the kind words GSH Electrical
i know I'm kind of off topic but does anyone know of a good place to watch new movies online?
@Vihaan Matteo i would suggest FlixZone. You can find it on google =)
@Vihaan Matteo i watch on FlixZone. Just search on google for it =)
@Vihaan Matteo Try FlixZone. You can find it by googling :)
Great guidance
Thanks
Nice simple easy explanation. Keep up the great videos. I wish RUclips was around when I was learning to become an electrician. Is a great reference point.
Hi. Many thanks, I shoot my videos at 7.30 in the morning all alone in my workshop so support is most welcome... wish my learners would watch them. All the best Gaz
Where are you based?
👍. I used to have a 4.0 mm single earth wire that I attached to the draw tape first . This 4.0mm was then used to pull in the other cables to avoid putting to much strain on the draw tape and damage it . Keep up with the videos.
very good, i learn so much from your video's, they are excellent
Very clear, think i had a moment before xmas trying to do this in the class room.!
Wonderful video and great explanation. Wish i had come to your Academy.
When I look back wish RUclips was out when i was learning about electrics it was all books then I'm retired spark now 65 love to keep the grey matter working tho great presentation
Massive thanks for the message of support 👍🏻
This went a long way for me; in this particular day of this particular year❤️
Thanks 👍🏻
You make it look so easy
Your video are so thorough great teacher
Massive thanks 🦾👍
This is the standard installation practice in Europe usually with flexi conduit chased in the typical masonry walls. I believe its also mandatory in Ireland?
It does make rewiring so much easier.
very concise and helpful
Very good and clear
Great video 👍 many thanks.
Thanks for the supportive comment 👍
A very informative and well presented video for learners, cheers.
No problem 👍
Great video gaz hope ur well mate
Greetings, I do enjoy looking at your video's. While this does apply to to the UK, I thought i would give you an idea of what they use here in the Philippines. Normal light circuit is single cables, NO CPC used, the use cable called THHN 2mm Sq. Stranded, you also can get solid core. Power outlets, Receptacles, Single wires, use CPC, cable called THHN 3.5mm Sq, Stranded, you also can get solid. Scary part is many power outlets do not have Earth (CPC), so only 2 pin sockets, but of course you also have 3 pin with CPC, a lot of it is based on the USA system, but using 230 volts, plus you also get a different plugs, some round European type and and some straight (USA Type), you can get global power outlets which will take any plug, there are very common. The light sockets, switches, power outlets us push in fittings, there is no screws. So you cut the wire to correct length and push in the socket, switch or whatever. One very good brand is Panasonic, but of course lots of cheap rubbish on market also. Basically no such thing as RCB or RCBO only circuit breaker, as you can imagine lots fires every year because of electrical wiring. Cheers.
Wow thanks for taking the time to put together your message. You bring up some interesting points. Thanks again and keep watching Gaz
Thank you 🙏
Thanks for this great video ... most of the Information in this video i do it in my work from 6 year becuse i use the bs 7671 regulations.
احمد الكهربائي العراقي Ahmed electrician of iraq حبيبي احمد أنت وين عايش ؟
@@aalazawi7287
انا عايش بالعراق /ديالى /بعقوبة
Great video, thank you. One question; if the nearest neutral for the second light was in the CU, can you take the neutral to the neutral bar in the CU? E.g. if the second light was on the left of the CU.
Thank you ☺️
Nice one man
Excellent video as usual. You make a throw-away comment at about 3 minutes in about not needing to use a draw line as the runs in this case are so short. But for longer runs do you have any tips about how to attach multiple singles to the draw line, without increasing the cross-sectional area or stiffness of the bunch (e.g. by using too many wraps of insulating tape) - maybe it's covered by another video which I haven't yet found ?
Nicely done sir
I have a young guy working with me 2 days a week for experience, he is doing his 2365 L3, sadly his college is pretty useless and I have had him watch your videos and he learns a lot more from your videos than at college!, the college teach him to pass exams but no actual work skills or real world scenarios. Do you teach your students to take the feed to switch rather than the ceiling rose? as its a good basis before going onto conduit.
Hi. Thanks for the kind words. New learners are taught the standard 3 plate loop in method for pvc/pvc wiring and conduit loop in method in conduit. However I have covered feeding the switch with all my learners as it is so common in industry hence the videos on it. Hope this helps Gaz
Another great tutorial. Can you get junction boxes that fit the conduit incase you were making a three plate connection to an LED batten? The only boxes I've seen don't seem to match the conduit. Kind Regards
Not that I know of... massive thanks for commenting and watching 👍
@@GSHElectrical Thanks for the speedy reply. So how do you use conduit to protect a lighting circuit if you want to use anything other than a bulb holder which has the junction box integrated into the base?
Absolutely brilliant video Gaz. However, I’ve made a little rig board exactly like yours, but the only difference with mine is, is that I’ve started with a one way lighting circuit, extending another two circuit which is a two way circuit taking the feed from my original one way circuit and then terminate my cpcs into maintenance free connectors, but when I tested the circuits and flick the switches into opposite positions I don’t seem to get a on and off operation. I check to see if there’s any default wiring but all fine. I’m just a bit confuse in the sense that it’s all wired properly but not working on the strappers. Any ideas on how to approach this.
Lincoln
ruclips.net/p/PL2Ea5r9gxUUevU9gv8lizD53aYvwiJ5qr
Hopefully this playlist might help 👍. Gaz
why not pick up the live neutral from the first junction box by using a terminal block? If I understand the 18th correctly, creating a branch off the main spur would be allowed provided it would only feed one end point? It would certainly make wiring it up easier and you essentiallyalready do this with the neutral?
Enjoyed that totally different from the domestic cable wiring, but I can see why you don’t need the sheath protection because the conduit does that job. Could it not be wired with cables as this way seems a lot more work and fiddly or is the point to reduce No of cables at the lights etc. Also most importantly you did your send off too quickly at the end. It’s meant to go. I hope this video has been…….pause some help with a big thumb love that don’t lose it or sell it to anyone else that’s your signature. Cheers for another good explanation.
Thanks for the detailed comment Robert 👍🏻
Nice videos thank you very much
Hi. Many thanks for the support GSH Electrical 👍
Do you identify (mark up) the switch line with any tape? As there are 2 brown cables? What would best practice be for that?
Hi. No identifying required. Thanks Gaz 😁👍
@@GSHElectrical thanks for the speedy reply Gaz. I would have definitely assumed there would be some labelling, would save testing the cables (if you were taking over the job at the point you get up to in this video for example and weren't able to see the cable runs etc.)
Are there any limitations for using singles in conduit for connecting together 2 outside flood lights on the same circuit. I know metal is best practice but I have not seen anywhere saying its absolute.
Will you show wiring 2 way switches in singles and emergency lights with switched fittings on same circuit and key switch,I get confused with singles,Great informative videos,Thanks.
I don't know if it's code in the UK to have to wire this way but it seems like you're wasting about 20% of your wire having to backtrack with your ground/CPC and your Hot/PermLine wire
Again I don't know if it's code but making a junction inside the lighting box with your ground/CPC and your Hot/PL wire would save having to go down and back to the switch
Like I said I don't know what code is in UK maybe they don't allow Junctions inside boxes that carry fixtures
If you could clarify it would be greatly appreciated. Thank you. Also, I realize this video is 3 years old.
i'm a bit confused why you're putting a cpc down to the switch and then another one back up when theyre all connected. when youre using steel conduit as a cpc you dont put a piece of conduit going down and then another one going back up
what is the difference with Live cable in domestic dwellings. Its wired exactly the same.
Holle see fixtures PDF 🤞🤞🤞🤞🤞
Hi. Just a quick one. When the 18th edition is out, is it mandatory to do the course before the exam or is it possible to do the exam only? thanks
Hi. You will have to hunt around to find a training provider that will allow you to sit the exam without training.... try a online training provider e-qualified.co.uk around £130 teach yourself at home package 👍then sit the exam. All the best Gaz
Why did you pull an extra cpc in when you already had one?
I always run a CPC but in theory everything is double reinforced insulated so need no earthing.
👍🏻
Explain for 2intermidiate 2way 2way and 1 socket outlet
Is it permissible to use plastic conduit to supply outdoor lighting say floodlights? Is there anywhere in the regs that deals with outdoor light fittings?
+ryewashere_ Thank you for that, is it necessary to glue the fittings together? I am only asking because some videos I have seen seem to suggest that glue is not necessarily required which seems rather strange to me :)
+ryewashere_ Fantastic, thank you very much.
Hi. Black PVC conduit and try and avoid direct sunlight (south facing walls).... correctly IP rated and fitting and seals as well. Thanks Gaz
why do u need a cpc in a switch. the box doesnt seem to be metallic. in india we only have L & N. CPC is given if the SB have sockets in them( yes we wire sockets and light switches together). what function does the CPC have in the switch.
Hi. The cpc is at the switch in case it is replaced with a metal one therefore making it an exposed conductive part.
ruclips.net/video/o72z_p8FIBQ/видео.html
All the best and thanks for commenting and watching GSH Electrical
You can buy 1mm singles, why do you say 1.5mm is the minimum in conduit?
Hi. The exam question is what size cable as a minimum do you wire lights when they are installed in conduit answer 1.5mm2. The reasons for this I explained in my video. 👍GSH Electrical
See?!!!!!!
But in the real world are you pulling singles through by themselves? Surely not.