Parallel batteries: one bank keeps charging when all the others are already full. But why???

Поделиться
HTML-код
  • Опубликовано: 4 янв 2024
  • After a short break over the Christmal Holidays, I'm finally back in the Off-Grid Garage!
    Today, we are having a closer look at a strange phenomenon that has haunted my battery shelf for a long time. When fully charged, the middle battery keeps charging far longer than the other two batteries even they are all in parallel!
    I made you an awesome white board drawing where we discuss both speculative causes: is the internal resistance in this battery higher or lower?
    After measuring the internal resistance, the answer is clear. Clear as mud!
    Battery resistance tester:
    off-grid-garage.com/measureme...
    Upgrading to Aluminium Busbars. Will this solve the issues?
    • Upgrading to Aluminium...
    Please subscribe and join me on my journey of the Off-Grid Garage!
    For more information, please check out my website with links to all the batteries, materials, devices and products I have used in my videos: off-grid-garage.com
    The 'Buy me a Beer🍻'-link is here (on the website, scroll all the way down):
    off-grid-garage.com Thank you for your support!
    You can also click on the Thanks button under the video to support the channel. Thank you, if you have already!
    T-Shirts, caps, mugs and more in our merch-shop:
    off-grid-garage.com/merch
    **** These are the batteries you are looking for ****
    🔋➡EVE LF280/304 LiFePO4 cells 3.2V/280+304Ah: off-grid-garage.com/batteries/
    🌞➡Solar charge Controllers, Inverters and accessories: off-grid-garage.com/solar-cha...
    🔧➡Tools, Analysers and Testers: off-grid-garage.com/equipment/
    📈➡ Battery Tests and Results: off-grid-garage.com/battery-d...
    🔌➡Batteries, charger and accessories: off-grid-garage.com/batteries-3/
    ⚡➡Cables, Inverters and Electronics: off-grid-garage.com/electronics/
    The Sunfunkit DIY battery. Great product to build your own 12V battery. Use OGGA at checkout to get 6% off. More info here: off-grid-garage.com/diy-kits/
    Video review: • The Sun Fun Kit Experi...
    Best prices for Victron gear in Australia: Auto Parts Co has you covered.
    www.autopartsco.com.au/?pd_pr...
    (they have 4WD parts and accessories too)
    Take a live sneak peek at the Off-Grid-Garage in the Victron VRM World (link at top of the page):
    off-grid-garage.com/victron-c...
    Here is my Tesla referral link, if you want to buy any Tesla accessories or even order a vehicle. This is a great way to support my channel. Thanks a lot to everyone who have used it so far 🙏 www.tesla.com/en_au/referral/...
    My other (German) RUclips channels:
    / offgridgarageaustralia
    Please don't leave any links in your reply. RUclips will not publish your comment in this case.
    If you decide to send me an email, I really appreciate your time and effort for doing this. However, please consider leaving a comment under my videos instead as I may not be able to reply to your email due to the sheer number of messages I'm receiving.
  • НаукаНаука

Комментарии • 266

  • @cristof48
    @cristof48 6 месяцев назад +18

    I think the problem comes from the chemistry of the cells, they are not the same brand, therefore different manufacturing, the chemistry must vary. It would be necessary to make a charge/discharge curve of one of the cells of each pack and check if the absorption duration varies between the cells.

  • @trevortrevortsr2
    @trevortrevortsr2 6 месяцев назад +21

    Andy look to your Mosfets - Not all Mosfets are equal - BMS with Mosfets have different forward resistances and/or different numbers of Mosfets in parallel will have different resistances - older cheaper Mosfets tend to have higher forward resistant which get worse as the heat up - a crude test would be to check which BMS get hot under similar high loads - Hugs from UK

    • @marklockwood7592
      @marklockwood7592 6 месяцев назад +3

      I agree with Trevor. Also, the on resistance of Mosfets is non-linear over current. In other words, you will get different resistances at different currents.

    • @trevortrevortsr2
      @trevortrevortsr2 6 месяцев назад +1

      @@marklockwood7592 That's so right- there have been a lot of advances in Mosfet' design and material purity in recent years - I imagine not all manufactures have caught up - some e-bikers have pepped up their bikes by the simple expedient of changing the Mosfets in their controllers.

    • @diyEVguy
      @diyEVguy 6 месяцев назад

      @@marklockwood7592 Intersting. Maybe use three identical BMSs as proposed by @stefanvanzyl9090 to see how things change.

    • @wg6215
      @wg6215 6 месяцев назад +7

      I would think that he could swap bms to see if the condition migrates with it. That might shed some light on the issue.

    • @trevortrevortsr2
      @trevortrevortsr2 6 месяцев назад

      @@wg6215 Sounds like a plan

  • @PVProDK
    @PVProDK 6 месяцев назад +8

    Have a look at cell 11 in the middle shelf. At 87% SoC it is already above 3.45V. I believe this single cell causes the internal resistance of the whole battery bank to be higher than the other banks, resulting in this "problem".
    I have two Seplos banks (with NEEEEEEEY active balancers) where I observe similiar behaviour, when charging with 100-140A (50-70A per bank on average) cell 9 in bank 1 goes to much higher voltage than the others. When discharging at moderate Ampeages the voltages are fairly equal, but when discharging with >100A the same cell has the lowest voltage.
    Highest voltage when charing and lowest when discharging means the weakest cell. I also observe that the bank with the weak cell charges slower than the other bank.

  • @TheDefpom
    @TheDefpom 6 месяцев назад +3

    I think it is due to the balancer, the middle shelf will have a more even cell capacity and so they all reach 100% at about the same time, meaning it can absorb more energy, the other two shelves will be more imbalanced so once ONE cell is at 100% the overall current will drop because of them all being in series, even though the other cells may only be at 95% or so.

  • @kencompton2742
    @kencompton2742 5 месяцев назад +2

    I've got to say, these JK Inverter BMS are nice, I've got 3 running in parallel right now, soon to be 5. Andy, you have helped me a lot in understanding these BMS and how to connect them and get them working right, thank you from sunny Nevada USA.

  • @marcoarpago
    @marcoarpago 6 месяцев назад +1

    I think is the BMS not the batteries, I think the JK will get more current when you are almost fully charged (say 55.0). But we will see that in your next video. Thank you for doing all the hard work for us !

  • @acinfla9615
    @acinfla9615 6 месяцев назад +1

    Good to see you again Andy!
    Glad you had a nice break with the family 😊

  • @stefanvanzyl9090
    @stefanvanzyl9090 6 месяцев назад +21

    Andy, I believe that the middle battery pack is better balanced than the other two, which causes it to have a slightly higher resting voltage than the other two banks. When you slowly discharge them, the middle pack then discharges more as it has a SLIGHTLY higher voltage overall for the first few minutes/ Ah discharged
    When you do a higher discharge rate, the overall voltages of each pack are dragged down into the flatter portions of the curve, which will then make the battery packs all supply similar current, hiding the higher resting voltage.
    Since you are working with 4 sets of variables here: cell size (304 vs 280), cell busbars (CU vs AL), bmses and the effects of longer cabling for the lower packs, I propose that you fit 3x identical BMSes for 1-2 weeks - preferably connecting them to your raspberry Pi / VRM to allow for logging and totalizing - This is "easy" since you already have all these new JKbmses which were bought at the same time and can run the same firmware.
    My hypothesis is that the higher trailing charge rate for the middle pack will disappear after 3-5 cycles

    • @upnorthandpersonal
      @upnorthandpersonal 6 месяцев назад +5

      Agreed. Eliminate some variables, and my guess would be the same as yours.

    • @houseofancients
      @houseofancients 6 месяцев назад +2

      Agree with this statement

    • @houseofancients
      @houseofancients 6 месяцев назад +1

      The voltage difference at charging is the key give away..
      Top and bottom pack have a higher pack voltage when charging, there for are less balance.
      Furthermore, as you paralleled 3 packs, once the difference between the packs becomes more than 2 mv, the batteries will try to balance out ( from my own exp.)

    • @ascii892
      @ascii892 6 месяцев назад +1

      @@houseofancients It looks like the top and bottom batteries have a lower delta voltage in the cells. at 9:58 the top and bottom battery have a delta of 25mV and the middle battery has a delta of 62mV. Although that might be because of the higher current in that battery. I wonder if the battery cells were balanced if this issue would be solved.

    • @noxikid
      @noxikid 6 месяцев назад

      Aaaannnnnd. Balancing is wasting some energy right? 😊 So little bit here and little bit there. My opinion is that with such count of variables this "problem" not worth another try/guess. It may still end up with a wrong conclusion. Thanks Andy for all the good work!

  • @ivoscuka8537
    @ivoscuka8537 6 месяцев назад +2

    Just to the side of the discussion. I use the YR1035 to quickly test the internal resistance of LiFePo4 cells. I then tested the same cells in a combination for battery banks via the EBC-A20 PC software and finally the same application with the EBC-A40L. All these tests were performed on dozens of Winston 60Ah cells and 16x EVE 304 Ah cells. All the Ohm values were completely different from each other even for single cell. Often even orders of magnitude different. You perform this task with the YR1035 for all three banks, so the implication of the instrument will most likely be very similar for all measurements. However, please remember that the real internal resistances will MOSTLY be quite far away from the results you define.👋Anyway Thank you.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      Yeah, if you use different devices to measure the resistance, you will most likely get different results.

  • @ricky786
    @ricky786 6 месяцев назад +7

    Hi Andy, try to measure the voltage drop across the battery bank BMS during discharging and charging. Maybe the BMS internal resistance changes/different during discharging and charging.🙂

    • @user-qg3qq2vz9e
      @user-qg3qq2vz9e 6 месяцев назад

      also measure the voltage drop across each bms at high current level and see if it has high deviation berween 3 bms (at same current)

  • @marktheunitedstatescitezen185
    @marktheunitedstatescitezen185 2 месяца назад

    I’m doing something similar but 7s 24v 280AH my BMS is a Seeplos 3.0 7s 24v 150A I have a stand - up battery case ! You are 1 of the top people on earth in knowledge about this !

  • @josee.torres764
    @josee.torres764 6 месяцев назад +1

    Happy New Year Andy!!! ...and from us in the Caribbean.... Happy Three Wise Men Day!!!

  • @edwardvanhazendonk
    @edwardvanhazendonk 6 месяцев назад +1

    Happy new year Andy and community. Can you also measure the battery bank itself, this way you have your bank and BMS resistance. There could be a difference. Maybe also validate with the same clampmeter what the real current and voltage is, set the BMSes accordingly. Keep up the good work this year! Thanks for all your efforts in debunking all myths and issues related to batteries, chargers etc🎉

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад +2

      Thanks Edward and Happy New Year to you as well.
      Yes, some have mentioned that here that the BMS could interfere with the measurement. I'll do more testing.

  • @wayne8113
    @wayne8113 6 месяцев назад

    Thanks Andy

  • @vp3319
    @vp3319 6 месяцев назад +1

    Thank you for sunny Australia.

  • @typxxilps
    @typxxilps 6 месяцев назад +2

    I guess the Battery Shelf 2022 might deserve its own video about the performance and cycles in the past 2 years I guess.
    And then it might also deserve a protection well known as DENKMALSCHUTZ cause it is so iconic cause everyone can recognice the long and winding road back then.
    And it is clean and nice - compared to the collection of batteries that appeared seconds later.
    After a long and winding road with EVE LF160 cells grade B we finally got a set of 16 x EVE LF280K grade A from a german electrician shop in Hannover.
    Grade A means in this case: all produced on tthe same day same production site and a row of serial numbers with a 305 Ah result for each cell over 3 single discharging test with EBC A40L in a heated room with 25°C according to EVE 's test procedure described in their 20 page long description.
    305 Ah means they are also running quite close from top to bottom with the Seplos BMS balancing close to nothing cause max deviation is about 0,002 V but only 2 are better cause 13 are 0,001 .
    And that is most likely not a cell difference but caused by the position in the battery cause when I mixed it up the results were not the same and the worst became the best. When I put it back in the previous order I got the same result as before, this time again the worst cell in the battery, whicch means from best to worst it is just a question where the cell sits in the battery cell chain. And the top balancing is a rather short procedure till its done.
    This is a complete different result and world compared to the LF160 Grade B cells (have been lasered and produced within about 7 months).

  • @LibertyDIY
    @LibertyDIY 6 месяцев назад +7

    I have a similar situation between my 4 parallel batteries. Two of them are CALB329Ah and two of them are envision 306Ah and 308Ah. The Envision batteries seem to get full first and under certain conditions they can even backfeed energy into the CALBs. I assume it has to do with slightly different voltage curves And as you said it's not an issue in practice.

  • @joulessolar8082
    @joulessolar8082 6 месяцев назад +1

    The explanation might be easier to explain using the charge curves of the batteries.
    When we build these batteries we found that matching charge curves for the 16 cells is more important than the internal resistance of the cells (importance of using same manufactured batch).
    What you have is a slightly different charge curves beween the batteries at the 3.35V-3.48V cell voltage range. Thus at the "knee" of the curve the middle battery is just a bit slower to get to the bend. It actually means that the cells used in that battery is better matched. The benefit is not huge but if you do the calculations the capacity would be 0.25-0.8% better than the bottom battery.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      Yes, that is a very good point. If the charge curves are different. the banks will charge/discharge differently.

  • @tonydickerson999
    @tonydickerson999 6 месяцев назад +3

    Measure the voltage drop across the positive connections and then the negative connections (input to output) of each bms with the same current flowing through each to see if the BMS is causing the issue (maybe the FETs have a higher forward bias)

  • @ellingolsen3194
    @ellingolsen3194 6 месяцев назад +2

    I have some Jakiper JK48V100PRO batteries. With one of the packs, I observe some of the same as you do. That is the oldest pack and it has slightly different cells inside. Different model cells and possibly from a different manufacturer. Possibly with a slightly different charging curve? But as you said, it is not a problem.

  • @donbaggarlysr
    @donbaggarlysr 9 часов назад

    Why is there only 91k subscribers? He is super informative!

  • @robertgoldman5129
    @robertgoldman5129 6 месяцев назад +1

    Hi Andy Really enjoy your video info and style and may have partial answere to above glitch (not seen in comments). Following things I have learnedfrom LIPO ebike builds. First, assume things you can't change are valid/the same (cell chemisty, internal resistance, etc.). Next, make similar the controllable variables such as: cell temps, BMS model, BMS voltage calibration, lead length/size, cell SOC, etc. This would mean manual "balance" to actual full capacity or SOC, replacing vertical bus bars with equal length cables (maybe only for test) or at least connecting to bottom of one of them), measuring internal resistance at actual usage high current dc level vice ac impedance, replacing aluminum bars with same copper, and NO balancing during test. This should point to most of cause if ONE variable at a time changed. Or, since that would take a long time, just ignore it but keep in mind for next time 3 or more banks need to be in parallel. Can't find it right now but correct way to parallel 3 batteries/banks really looks weird (SLA but LFP also due to flat charge/discharge curve). Keep up the good work please and cold one sent., Dick

  • @etusuku8848
    @etusuku8848 4 месяца назад

    Hi Andy! I have been figuring out the daisy chaining batteries and the different voltage losses in those parallel connecting cables. If you think about battery voltage difference with almost empty and almost full battery bank. That voltage difference is much more than the voltage difference caused by the non equal battery cables. So the small voltage difference caused by the cables is not so big deal. The batteries will become almost empty and almost full :)

  • @FutureSystem738
    @FutureSystem738 6 месяцев назад +1

    Glad you had a great family Christmas Andy, you deserved it. 👍
    Happy 2024, and have great year.
    Interesting… I’m still watching the video but my speculation: maybe different BMSs are not such a great idea??

  • @matija3791
    @matija3791 6 месяцев назад +1

    When you swap out the bmses, please redo the impedance measurement to check for the influence of the bmses!

  • @marktheunitedstatescitezen185
    @marktheunitedstatescitezen185 2 месяца назад

    I love this Battery bank Self !

  • @neduodumbu1969
    @neduodumbu1969 6 месяцев назад

    I think the different charging current is as a result of the availability of internal active balancer in the JK BMS.
    All the cells in the JK BMS bank are balanced and takes the all the energy they can store.
    I suggest you verify the overall Watts hour stored in each bank and compare with the rated capacity.
    Thank you for all the good work you are doing.

  • @StarJackerSRL
    @StarJackerSRL 6 месяцев назад

    That is why i use different solar and charger array for each battery bank, and combine the battery banks through diodes so no power is transmitted from one battery bank to the other. Will be making some videos about my system soon. Amazing work Andy. I love your channel and your expertise. Keep it up 👍

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      The balance current from one bank to another is not a problem with LiFePO4. It is very small or even non existent. Depending on your system size, you can install separate chargers and arrays for each battery as you did.

    • @StarJackerSRL
      @StarJackerSRL 6 месяцев назад

      With my system it is better with the diodes because the BMS's control solar charging for each battery bank but all BMS's control the inverter, so if one cell would fail without the diodes all power would go to the failing cell and fire/explosion could erupt.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      @@StarJackerSRL That will not happen. that's what the BMS is for. If one cell fails, the BMS will disconnect this bank from the system. The diode will not help.

    • @StarJackerSRL
      @StarJackerSRL 6 месяцев назад

      @@OffGridGarageAustralia 123SmartBMS does not do that on it's own.
      My BMS only controls the inverter and incoming charging from solar panels, that is why i use Victron diode battery combiner.

  • @balanwyt
    @balanwyt 6 месяцев назад

    Thanks!

  • @junkerzn7312
    @junkerzn7312 6 месяцев назад

    Happy NewYears!

  • @leandrotorquato3606
    @leandrotorquato3606 3 месяца назад

    Sou do Brasil tenho um sistema off grid e adoro seus vídeos parabéns !

  • @Lancemanion
    @Lancemanion 6 месяцев назад +1

    I have noticed the very same thing with my system.
    In particular my 1 bank of 3P x 16s Identical cells (EVE 280's), identical BMS x 3 packs wired similar to yours.
    All batteries were from a single batch, BMS's from same production run. Active balancers also same production run. All were installed and commissioned within days of each other.
    In my case (and yours) cell capacity matching of the banks is the only difference. The best "capacity matched" bank, takes the longest to discharge and recharge as compared with the others. In your situation, you could also add the small differences within your different bms's.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      Thanks for sharing. I have also the aluminium bus bars, so more variables to play with. I really don't think it's the BMS...

  • @Der_Hannes
    @Der_Hannes 6 месяцев назад +1

    Hey Andy,
    when you switch the BMSs, you should check the Resistance of the Breakers too (measured after the Main Breaker).
    It would be also interessting if the effect can be observed if you charge to a higher voltage. I think it could also be a slight difference in chemistry of the cells.
    Looking forward to see what you can figure out there!
    🐸

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад +1

      Yes, breaker could play a role but I doubt that would make such a huge impact.
      Charging to a higher voltage shows the same with the middle battery still charging longer.

  • @universeisundernoobligatio3283
    @universeisundernoobligatio3283 6 месяцев назад

    Merry Christmas and a happy hangover.
    Did you zero the low ohm meter?
    How repeatable is the zero measurement?
    How repeatable are the resistance measurements?
    How matched are all the cells?

  • @curacao11
    @curacao11 6 месяцев назад +1

    happy new year😎

  • @davidpenfold
    @davidpenfold 6 месяцев назад +1

    The one symptom I noticed was the middle shelf having a slightly lower voltage than the other two when charging above 3.4V, which explains why it charges for longer.
    But as to why it has a lower state of charge, I guess you'd need to look at each variable in isolation, such as swapping out the cell busbars or the BMS with one of the other batteries etc.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад +1

      There could be a small difference in measuring the voltage across the three different BMS. Some here have seen a slightly higher voltage, you see a smaller one...
      I have more insight in one of the next videos...

  • @clarencewiles963
    @clarencewiles963 6 месяцев назад +1

    I don’t know if one of the battery cables has one more strand of wire or a thickness and size of the aluminum bars. But I will check out a cold beer 🍺 and get back with you 😊

  • @CantFindInYoutube
    @CantFindInYoutube 6 месяцев назад

    Andy regarding alu or copper the thickness is important but also the contact area and material of the bolts count. I have a similar situation, need to find time to investigate since it stress more one of the batteries.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад +1

      Well, the contact area is not too important if the torque is sufficient. Whe have tested this here and could push over 230A through the tiny contact area of terminal and bus bar: ruclips.net/video/VPQvs-2YYzA/видео.html
      And I'm still running this exact setup in the top and bottom battery.

  • @peetbraun9439
    @peetbraun9439 6 месяцев назад

    Hi,
    the different impedeance would cancel out during an discharge/charge cycle, but you have not taken into account:
    a) if discahrged, (and then leaving idle during the night) the banks will equalice by voltage and so charge the bank witch was discahrged most du to lower resistance.
    b) your top bank has higher capacity, and so lower resistance provinding more power

  • @SebastianHeld
    @SebastianHeld 6 месяцев назад +1

    I don't think that this impedance measurement can be used to explain anything. As you mentioned: it uses a 1 kHz signal to evaluate the impedance. Your BMSs will have some capacitors across the rails and therefore disturb the measurement. Finally, it is the resistance at DC, which steers the current, not an impedance at 1 kHz.

  • @timchambers5242
    @timchambers5242 6 месяцев назад +1

    Powerwall turned 2yo, time to help the toddler to talk to you.

  • @user-ji8ws6sm6r
    @user-ji8ws6sm6r 6 месяцев назад

    I'm almost sure that the problem arose because of BMS
    Because every BMS measures current based on the voltage drop on both ends of a resistor (that is, within the internal design of the BMS, resistors of a small value are placed to measure the current).
    It seems that JK BMS uses resistors to measure current that have a lower value than other companies
    A while ago, I had a similar problem, and the reason was the internal resistance of the multimeter (for measuring current).
    You can confirm that this is actually the cause of the problem by placing the JK BMS in the lower or upper battery pack and observing the results

  • @pulsedmotor
    @pulsedmotor 6 месяцев назад

    It's because the three bms's are fighting each other. For power. ❤❤

  • @philiptaylor5130
    @philiptaylor5130 6 месяцев назад

    Sorry that sounded a bit rude, I'll try again....
    Hi Andy,
    I think it could be Calibration of the different BMS's If you check voltage at each battery bank voltage will be same. but JK BMS is showing lower hence will keep charging as it thinks it's at a lower voltage.
    I have a 5 bank that did the same thing.
    And keep up the great work Best channel on here.

    • @Der_Hannes
      @Der_Hannes 6 месяцев назад

      Hi there,
      but the actual voltage on all BMSs is the same - and non of the BMSs is limiting the current or stops charging the battery. The measurements of the BMS does not matter at all.
      What do you think about that?
      Greetings

  • @elmer665544
    @elmer665544 6 месяцев назад

    First see if it follows the BMS when swapped. If not, I would set up a high current flow and measure for voltage drop in the milliamp range on both the positive and negative cable paths of the middle battery. That is how I found a weak connection on my solar system.

  • @ThanosSustainable
    @ThanosSustainable 6 месяцев назад

    My take is that the middle battery has more losses for some reason. Hence, when discharging it is discharging a bit more than the other two, and it has to recover more energy on its charge cycle.

  • @HermitHippy
    @HermitHippy 6 месяцев назад

    The difference may be in the bmses themselves. It would be worth checking the impedence across the bms alone, then the battery banks alone.

  • @USL.Website
    @USL.Website 6 месяцев назад +1

    Hey Andy, Happy New Year! Just wanted to ask about the 3D printer update and if you share any of your STL files you designed or find useful?
    Always enjoy your videos and congratz on the boat!

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад +1

      Yes, I will share all the STL files. I haven't done any printing since but will be designing some stuff in the near future.

    • @USL.Website
      @USL.Website 6 месяцев назад

      @@OffGridGarageAustralia Thank You!! cant wait :)

  • @zeropointbalance7366
    @zeropointbalance7366 6 месяцев назад

    First, please notice the charge voltage and the voltage at the battery
    At 8:09 they match for each battery (approx), - the 55.2V to 54.8V offset is due to the bus-bar-to-battery drop at 80A?
    V1 V2 V3
    Batt V 54.84 54.82 54.8

  • @retrozmachine1189
    @retrozmachine1189 6 месяцев назад

    My goodness.
    Battery current diverging during charging as each battery comes up to fully charged at a different time due to variations in manufacture, wiring etc etc, leaving the one with a lower relative SOC to soak up potentially undesirable levels of current in a system that does not monitor individual battery current? That can't be right as it's been stated a few times in the past by the channel operator that he's checked and his batteries don't have this problem. I do remember some guy banging on about this in the past and that seemingly cluey guy also said that it happens to pretty much every battery system out there which is why the commercial setups monitor this sort of thing. We're not quite there though as apparently it's not really a problem, but give it a couple of years and we'll see how the story evolves.
    It is true what they say. You can lead a horse to water but you can't make it drink. You just have to leave the horse there and hope it eventually works it out for itself.

  • @tomassliauteris884
    @tomassliauteris884 6 месяцев назад

    Dear Andy, what I found in my shelf, that when charging with Jk weeker cell goes higher voltage, then active balancer takes out energy, but when current go's down at 55.2 this weeker cell starts to use more ampers and, and active balancer put back energy to weeke for absorption. While pasive balancer was not able to make so big trouble for weeker cell.
    So, my prediction is that please change active balance current from 2A to 0.1A and look for a few days. You will be surprised that weeker current is enough.

  • @greg6609
    @greg6609 6 месяцев назад

    Different BMS, different circuitry. I have 4 batteries and made them with identical cable lengths, cells and BMS, I do have some variation between the batteries during use, but only minimal - up to 5% of the charged status maximum.

  • @chuxxsss
    @chuxxsss 6 месяцев назад

    More storms here tomorrow, 35 mm, maybe tomorrow. I'm still working out my system. The room is very cool now for my batteries. 😊

  • @uksa007
    @uksa007 6 месяцев назад

    Can I hedge my bets:
    Guess 1: I think it may be related to bus bars, thicker does not always equal lower overall system resistance, as there are small contact areas and the issues with corrosion.
    Guess 2: Overall ESR of the battery is just higher due to the goop they used.
    Guess 3: The BMS has a higher resistance.
    Swap the BMS around, if it doesn't follow the BMS, replace the bus bars with same as the other packs.
    Only way to be sure, nuke it from orbit :-)?

  • @Raphael_Hofmann
    @Raphael_Hofmann 6 месяцев назад

    I think your guess is right. The middle battery get's fully charged last and the top and bottom absorb earlier. But it could also be the cells or the BMS voltage drop 🥴

  • @technician1974
    @technician1974 6 месяцев назад +1

    Hi Andy , hace meses te sugerí usar una misma marca de BMS , solo estás haciendo que algunas baterías trabajen más duro que otras 😅

  • @KevIsOffGrid
    @KevIsOffGrid 6 месяцев назад +1

    Is the middle shelf the 280K and the bottom 280 not-K and of course the 304's are also non-K type. Just a subtle difference in electrolyte and therefore a slight change to the charge curve?
    Like you say, its not causing problems, and other than swapping round BMS's or busbars eliminate those variables its the only difference other than capacity - unless the middle shelf were B-grade, or a different factory or batch is maybe all it takes to shift the charge curve a little.

  • @rudydepooter9513
    @rudydepooter9513 6 месяцев назад

    Hi Andy, Switching bms could be a good test to see what is happening.
    My 2 cent is simply cell. You don't have 3 batteries but 48. Over 48 cells, they are suffering differently over the time.

  • @upnorthandpersonal
    @upnorthandpersonal 6 месяцев назад +4

    How long until the middle bank catches up? I can't imagine it being more than a minute or so? Do you see the same if you charge to 3.5V? If you do, how long does it take to equal out now?

  • @mfgxl
    @mfgxl 6 месяцев назад +1

    Smart Wife. More on the Boat please.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      It's on the other channel. Video will be coming out Monday 5am AEST 😉

  • @MrCadilLACI
    @MrCadilLACI 6 месяцев назад +2

    please test us some NA-ion 220Ah batteries! PLEEASEEE

  • @henvern
    @henvern 6 месяцев назад

    The higher the current the higher the battery temperature and lower the internal resistance. Lower the resistance, current gets even higher. So one battery always wins the charging race. Adding series resistance (thinner cables) will help to balance the charging rates.

  • @CaptBill69
    @CaptBill69 6 месяцев назад +1

    Interesting Topic, ... as I have three 24v 280 Ah Eve battery banks (purchased one or two years apart), that all have the same 3 BMSs; with one battery bank charging or discharging at lower amps. I have suspected difference in individual battery cell chemistry and internal resistance; not sure. Was going to switch battery bank positions and keep bms positions while cleaning all bus bars and bms wire loom connects (someday), .. as a test for learning more all the time ... for later. Not immediate concern as my setup is working good. Look forward to your next discovery on this topic. 🐾🐾🎶🌠 15:26

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад +1

      OK, so, if your banks are from different age, they may charge a bit different. That will be quite normal. Calendar age takes its toll. But yeah, swapping the positions can mitigate that.

  • @GrahamPearce-ib9om
    @GrahamPearce-ib9om 6 месяцев назад

    As the charging voltage applied to the shelf is the same for the three banks, for more current to flow through the middle bank its resistance must be lower. Using ohms law actually calculate it rather than dicking around trying to measure it. Use your amp meter to confirm readings and Swap the shunts around after checking all connections to confirm that there is no variation between them..

  • @awesomusmaximus3766
    @awesomusmaximus3766 6 месяцев назад

    Cool

  • @Pimpasxx
    @Pimpasxx 6 месяцев назад

    I recently measured the impedance of my paralleled batteries with JK BMS (100A and 150A). I found out that one battery has an impedance of 4.8 milliohms while the other has an impedance of 5.0 milliohms. I used the original copper busbars with a torque of 11Nm.
    I was surprised when you mentioned that your impedance was 10mOhms. It seems that you did not pay attention to the length of cables, good contacts, and too many breakers. I suggest that you retighten all your busbars yearly with a minimum torque of 10Nm for better performance.

  • @chrisgroothoff2611
    @chrisgroothoff2611 6 месяцев назад +1

    I am going to suggest that changing the BMS on the middle shelf is not going to change the charging behaviour.
    Andy confirmed that there is very little difference in the battery resistance which just means that the batteries are of a similar condition. It is possible that the each BMS will also have slightly different, but I think that will have very little impact on the charge times.
    Is it possible that the actual internal chemistry of each of the battery type on each shelf is slightly different even though the batteries are charging with similar charge current, the time it will take to charge the differnet battery types will be different.
    Using the same argument, each battery type will also discharge differently which will then impact the charge time required to fully charge the batteries again.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      I don't think it's the BMS either. My bet is on the bus bars and connection to the aluminium terminals of the cells...

  • @johngreen6484
    @johngreen6484 6 месяцев назад

    It is because of the active balancer, it is lowering yhe voltage when balancing this causing more amps to flow.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      The passive balancer will do the same. And even worse than the active balancer.

  • @aftabmaqsood
    @aftabmaqsood 6 месяцев назад

    i would just say the middle one has different charge and discharge curve around that voltage 55

  • @fredflintstone1428
    @fredflintstone1428 6 месяцев назад

    Hey Andy, Happy New Year. Would you believe it, but I've just ordered SIX Seplos Mason 15kWh batteries for an electric catamaran I'm completing! I'm thinking of powering it with four EPropulsion Navy 6.0 motors. It looked like your boat maybe had an EPropulsion motor too

  • @nikola611
    @nikola611 6 месяцев назад

    Andy, it's because the Australian sun doesn't like the middle pack 😅 or maybe the solar panels are misbihaving.

  • @jimduke5545
    @jimduke5545 6 месяцев назад

    I’m a bit puzzled: By not measuring the impedance from each busbar across the cables into each MCB, through each MCB, and across each battery, you still have 3 unknowns (at least, unmeasureds) in the system-the Positive busbar to MCB positive output and negative MCB output to negative busbar for each of the 3 batteries. This might explain higher resistance and lower voltage of the middle shelf battery.
    A second source of variation in resistance could be your busbar connection configuration. I’d have to go back and see the video(s), but I think you did use a diagonal config and kept the MCB to busbar positive cables equal length (to each other) and negative cables equal length (to each other). In theory, each of the unmeasured cable/busbar cumulative resistance should be the same if you used diagonal wiring and had same distance between each battery cable.
    Unmeasured Sources of variance could be torques, washers, crimps, different wire chemistries, corrosion, and-outside the wiring-the MCBs when closed.
    If, after you have done the swapping of the BMS’s (I’m assuming YT production times and you’ve already done the swapping), and the slower charge/load rate doesn’t follow the middle BMS, you might look at these things which are currently assumed.

  • @jeffschroeder4805
    @jeffschroeder4805 6 месяцев назад

    Would measuring and recording the voltages across each individual bank with an accurate DMM while simultaneously recording the amperages, either charging or discharging, allow you to use ohms law to determine the overall resistance of each bank? I imagine each bank uses different sensors to evaluate the amperage going in and out of the battery banks? There might be some significant variance between them as well, particularly at high or low charging rates. Their response may not be as linear as one would like. It would also be interesting to check the voltage differences at different locations on the bus bar - at high amperages, even small resistances could cause significant, and therefore measurable, voltage drops.

  • @marcobrian1619
    @marcobrian1619 6 месяцев назад

    Hello Andy, and happy new year....
    Just a down side to things......here in UK ....our days are getting longer and yours are getting shorter......ha ha
    (Don't pay it back in 6mths)
    I take it all your BMS have same settings, but as you said in last minute of video.....
    You have different BMSs and all 3 are working on 3 different banks....
    Ok top back is 305ah
    Bottom 2 are same but with different bus bars and different BMSs.......for get the top one.
    Now the lower 2..... different BMSs, different bus bars , different temperatures (due to hight day night thing)
    Different age.
    I'm thinking it be something simple.... forget data thing......also middle one is first of the 280 ah cells connected to dicarcarge point???
    Is it as simple as this bank is next low ah bank and so discharge a little more everyday than bottom bank????
    I know you have built a fantastic battery bank and its well perfectly well laid out.....
    You do have a Mish mash of cells BMS and bus bars.....
    If it was all the same.....then I would ask the question as you have.
    I'm a fitter on plant equipment......you can have two machines.....but both are not alike...
    Never over look the basics.....forget data.
    I don't think it will help, but thats how end up fixing faults.
    Sorry for going on Andy.
    Look fwd to out come.

  • @pw5548
    @pw5548 6 месяцев назад

    I have the same but i am using 3 identical jk bms. But my cells have a different manufaktorer. My CATL cells still take Power even if the eve and the rept stopped.

  • @offgridwithpojectham
    @offgridwithpojectham 6 месяцев назад

    Hi Andy!

  • @SOLAR-cr5dp
    @SOLAR-cr5dp 5 месяцев назад

    What about the individual battery isolators’ contact resistances? You might want to test them also.

  • @KB-lj4vk
    @KB-lj4vk 6 месяцев назад

    The middle bank cells have degraded less over time. Do a capacity test on each bank and see which one is closest to the original capacity.

  • @garys-half-baked-offgrid-dream
    @garys-half-baked-offgrid-dream 6 месяцев назад

    I speculate the Heltec BMS will be swapped out for a DALY😂😂😂
    I haven't a clue about your battery shelves, I just hope it isn't the JK BMS as I have only just finished my battery shelf and turned my JKs on 😱
    Cheers
    Gazza 🏴󠁧󠁢󠁳󠁣󠁴󠁿

  • @crazyproject6019
    @crazyproject6019 6 месяцев назад

    Maybe you need to check voltage lost on cable.some time resistance can increase when voltage flow.

  • @zisaurierzisaurier9286
    @zisaurierzisaurier9286 6 месяцев назад +1

    You should give your family not only one photo, even not two. For next christmas: give them a tablet with your channel in repetition mode! And the year after a webcam into your garage.

  • @stephenhickman9502
    @stephenhickman9502 6 месяцев назад

    I love your channel. I've been slowly building myself an off grid system. I have learned lots from you, Will, and some others. I still have many questions do to being inexperienced. That being said, I am a journeyman electrician here in South Carolina. 99% of my experience is A/C. Is there any e mail or something where I can ask questions about my system? Thank you in advance either way.

    • @egg399.
      @egg399. 6 месяцев назад

      Drop your questions in the comments. The community will be glad to help I’m sure. Andy does look through comments but as you can imagine he can’t get to every one.

  • @itsdouetthierry
    @itsdouetthierry 6 месяцев назад

    Hello Andy! Happy New year ! Can you install a Victron Battery Balancer? Would that help?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      That would not help as the batteries are in parallel all the time anyway,

  • @zisaurierzisaurier9286
    @zisaurierzisaurier9286 6 месяцев назад +1

    How long does the middle takes longer? How much energy more or less or equal? Complete curve of middle and bottom in direct compatison?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      I would say around 10min until it catches up with the other two banks. At an average charge current of ~25A that could be 5Ah. Seems excessive to me...
      I don't really have a device which can measure the charge curve of a whole bank... wait.... maybe...💡

  • @potetespammare7361
    @potetespammare7361 6 месяцев назад +1

    Hi Andy, I have the same question as you! I connected two battery packs, each with 16s 280Ah, using the same BMS (which don't communicate with each other), cables of the same length, an equipotential bar, and the same brand of cells. The only difference is the production date of the cells. I also tested the resistance by measuring voltage drop. But nothing! I just can't figure out why the cells are behaving so strangely. Sometimes they seem perfectly synchronized, other times one discharges much more than the other. I think there are many factors at play, including cell temperature. However, it seems more like a theoretical question because, in practice, the system works. Overall, the cells seem to work similarly over time, so I assume aging will be similar. Thanks and greetings from Italy!

    • @Juergen_Miessmer
      @Juergen_Miessmer 6 месяцев назад +1

      I have EVE LF280k from different production lines and only a few days apart. They have in average around 4Ah difference in capacity, but they have diffrent charge curves. Seems there are big tolerances in materials and manufactoring.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      The charge curve could be what is different here.
      Even having a 100Ah and 280Ah in parallel did not show such a result as the 280Ah bank always charges/discharges faster and they meet again at the end.

    • @potetespammare7361
      @potetespammare7361 6 месяцев назад

      @@OffGridGarageAustralia In reality, the behavior seems completely random, as batteries often reverse roles. Is it not related to the quality of the cells? It appears to be linked to random factors.

  • @cascallana2626
    @cascallana2626 6 месяцев назад

    We miss you

  • @kurayamix
    @kurayamix 6 месяцев назад +2

    Yeah swap bms would tell if bms is the cause.
    But i guess it is because of the active bms method.
    Maybe it will waste more energy than passive and take longer to fully charge. 😅

    • @stefanvanzyl9090
      @stefanvanzyl9090 6 месяцев назад +1

      passive balancing discharges higher voltage cells via resistors - throwing away energy as heat.
      Active balancing discharges a higher voltage cell into a capacitor, and then uses the stored energy to charge up a lower cell - less heat overall

    • @LibertyDIY
      @LibertyDIY 6 месяцев назад +1

      ​@@stefanvanzyl9090in theory, but maybe in practice the JK pulls more power over time?

    • @stefanvanzyl9090
      @stefanvanzyl9090 6 месяцев назад +1

      @@LibertyDIY BMS power consumption by itself is in the order of a few milliamps. These packs are cycled daily and the behaviour is highly repeatable one day to the next -even a 20mA consumption/wastage difference over 24 hours is only a 0.48Ah difference, which would be replenished in less than a minute at this 40A charging rate difference

  • @MrSummitville
    @MrSummitville Месяц назад

    So, what is the title of the video that answers the question presented in this video? The next videos appear to discuss the "reset" issue with the JK Inverter BMS.

  • @MrButuz
    @MrButuz 6 месяцев назад

    It looks like its a combination of the higher resistance (so harder to charge) and the active balancer (which is constantly bleeding off some current 24 hours a day) means the middle pack is effectively getting less into it. Because they are in parallel, you can't really "see this" on the voltage as the voltage will always automatically equalise between all 3 packs - but it appears it manifests as strange but repeatable differences in current? Very interesting and to be honest it doesnt really matter as long as all packs do charge to 100% and all cells are kept equal in each pack? Also I don't think you can see internal resistance during discharge as the cells can effectively discharge instantly (if you short them)?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      The active balancer is only working if one cell hits 3.45V. It does not work 24/7 as most other balancer will.

  • @mikekimble6084
    @mikekimble6084 6 месяцев назад

    I noticed this same current change between Daly and JK. Fixed it, I put JK in as they arrive😂

  • @ascii892
    @ascii892 6 месяцев назад

    The only thing I can think of is there is a slightly higher self discharge on the middle battery. Is there a difference if the time between full charges is long or short?

    • @stefanvanzyl9090
      @stefanvanzyl9090 6 месяцев назад +1

      Since the start of summer, these batteries see full charge almost every day

  • @team13thirteen
    @team13thirteen 6 месяцев назад

    Voltage Current Calibration of the BMS! I use 3 Pace BMS after calibration oft the BMS on 3,65 Voltage everything is spot on! Also The Neey Balancer can be calibrated… I tested 10 Neeys on 1 Battery at 58,4V they are all slightly off 😉 after calibration everything is good… balance Leeds calibrated is also possible!

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      But this would not explain, why the middle batterie charges longer if the BMS is slightly uncalibrated.

  • @IanNature7
    @IanNature7 6 месяцев назад +1

    🦦 Happy new Year lovely Andy 🎉 so first question of the year whats that -🫃🏼eh 😵‍💫 no but when are we going to test the sodium ion batteries 🫣🥰🙏

  • @jimdangle4579
    @jimdangle4579 6 месяцев назад

    I think manufacturers have varying charging curves so your results don't seem too odd. Would be more odd if you were using the same BMS brand across all three batteries with mirrored settings. Are all of your BMSs set to the correct chemistry?

  • @lotsad1234
    @lotsad1234 6 месяцев назад

    The jk battery was unbalanced, so only 1 cell was full, raising the voltage. This happened to me when put toguether a battery with 15 cells from one batch and 1 from another that was quite a lot more charged..

  • @Ilnostroamicosole-Casa-offgrid
    @Ilnostroamicosole-Casa-offgrid 5 месяцев назад

    Hi Andy, what if the problem was the real capacity of each battery?
    maybe as the years go by they have different abilities that bring you this problem.
    I don't think the problem is the BMS.

  • @danieljaros7143
    @danieljaros7143 6 месяцев назад

    Different capacity is the answer to the question why.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  6 месяцев назад

      Top battery has the highest capacity by far. So should this not charge longer?

  • @marco1862
    @marco1862 6 месяцев назад

    Did you calibrate the Voltage measurement of the JK BMS? There is an option in the settings to calibrate it. It could be your just thinking it is not fully charged?

  • @MaximaleCoolness
    @MaximaleCoolness 6 месяцев назад

    Hallo Andy, ich weiß nicht ob ich es abschließend richtig verstanden hab, aber den Stromfluß zu deinen Batteriebänken bestimmt grundsätzlich mal der Spannungsunterschied. Die Zellen haben beim Laden eine bestimmte Spannung erreicht (z.B.55,0V). Der Unterschied oder die Differenz zur eingstellten Ladespannung (55,2V) beträgt nur noch 0,2V. Wären jetzt alle Innnenwiederstände gleich, würde überall der gleiche Strom fließen. ABER, die Spannungen der Zellen (Bänke) sind unterschiedlich, verrechnet mit dem jeweiligen Innenwiederstand bekommt man einen anderen Stromfluß bis zur vollen Aufladung. Am Ende der Aufladung haben alle Bänke die gleiche Spannung. Aber bis dahin ist das Verhältnis aus unterschiedlichem Innenwiderstand und Spannungsunterschied der Bänke mit der Ladespannung entscheidend. Nur ein Spannungsunterschied treibt den Strom durch einen Widerstand. I=U/R also "Spannungsunterschied, geteilt durch den Innenwiderstand = der aktuelle Strom" oder 0,2V/0,011Ohm=18A, was deinen Beobachtungen nahe kommt. Kannst gern auf deine Batteriebänke umrechnen. VG Jan

  • @GregOnSummit
    @GregOnSummit 12 дней назад

    Did you ever get an answer to this? I was thinking the "Profile" that each BMS has in the firmware.