You just helped me fix a super nice/free mini fridge! I saw it on the side of the road in a super nice neighborhood with a free sign and hoped that it would work, I was disappointed when I heard the click of the overload switch kick on. I tested for continuity and it was on all 3 poles and also no short to ground. Also tested amperage of the pull and it was well below short. Bypassed the relay like you showed and boom! Compressor rolling perfect and nice cold fridge. Thought it was shitty that the rich bastard put a broken fridge out and just put free without "need tlc" or "needs to be fixed". They knew it didn't work and could have taken it to be recycled, but I am glad they didn't ☺. Their loss is my gain. Replacement relay costs 7 bucks and will be here in 2 days!
Thank you so much for this video. I have an old Frigidaire freezer and the genuine controler relay is discontinued from Frigidaire but worst it is that absolutly unavailable in the aftermarket. So far with your video I was able to start the freezer and save the food inside. I leave it work until it stop then make the contact (as shown) to restart it. I have ordered online another relay (look alike) and according to your indications I should be able to plug it on the compressor and fix this problem. Thanks again.
Thanks you very much Sir! After a long time looking I finally came across a discarded fridge which I was able to salavge the compressor from, and thanks to your video I just tested it and it works perfectly. I'll sort it out with a momentary switch for a quick start and it will be ready to get into work helping me in the shop.
This is good information to know if you are waiting on a new relay and got food in the fridge. I turned my freezer to max so it will stay colder longer between jump starting it. Also filled up some Tupperware containers with water so they turn into big blocks of ice. thanks for this info
@@kadiskartemotv Of course! Your video helped me rule out compressor failure, diagnose the problem as a failed Time Start Device, and implement a temporary workaround to avoid spoiled food pending replacement. I installed the new TSD today and the refrigerator now works perfectly. Thank you again!
Hi, thanks for the video. I have a question. In the uk you have live, neutral and ground which one of these wires do I connect to the common pin?. Thanks
Thanks a lot dude worked well.searched and lokked for lots of videos.but only this worked.i have a questoion.bcs if there is a power cut we must always connect and disconnect that wire what if i put a switch to it
After 20+ videos I found this one about my fridge compressor. I was minutes away from hotwiring it and then it kicked back on. Shot always happens the day after you buy 500$ worth of grocery’s.
The hot wire goes to the middle COMMON pin, the neutral wire goes to the right RUN pin, and the wire spliced into that neutral wire goes temporarily to the left START pin.
The compressor in my GE fridge started without the capacitor, but if yours doesn't and needs the boost, then splice two wires and put the capacitor in parallel with the one that temporarily energizes the start winding.
i tried this on a wine cooler thats not working and the compressor turned on after connecting hot wires to just the common (top prong) and Run (right prong). I did not have to to touch the Start. Does this mean the compressor is bad?
Yes, simply unplug the fridge, make all three connections as described (COMMON, RUN, START), plug in the fridge, and remove the splice wire from the START pin as soon as the compressor starts. Just keep in mind that a) there is no external overload protection (as is typical with a Time Start Device / TSD) and b) when the thermostat sees a low enough temperature, it will cut power to the compressor (normal behavior), but when the temperature rises and it sends power to the compressor again, the RUN winding will be energized but the START winding won't (abnormal behavior), which could damage the compressor. So, when the fridge turns off the compressor, it's best to unplug the fridge, disconnect all wires from the compressor, plug in the fridge, and restart the compressor manually later when you hear the fridge start up the evaporator fan.
Sir yung start at run. Nong denerecta ko sa line.nka fix yung spilceng.bigla nlng umosok sa loob ng compresor.ano dapt gawi sa susunod na conection ko Para dina magkamali.
ka diskarte idol, tanung ko lang halimbawa kpag mag-vacuum dba sa access valve ang connection, saan ang hinihigop nun yung discharge o suction line??reverse ba cycle nya opposite sa cycle ng compressor? ty
Sa suction line po ang hinihigop. Intake sa suction at discharge naman sa discharge line. Continues flow/cycle . Salamat po sa panunuod. Wag kalimutang ilikenm ang video
No. PTC relay will automaticaly energize the compressor without our supervision, doing so will over heat the compressor, as common and run is only needed once once compressor reach atleast 1/4 of its speed,
My compressor started without the capacitor, but if yours doesn't and needs the boost, then splice two wires and put the capacitor in parallel with the one that temporarily energizes the start winding.
Mostly Start is always at left and Run is at right. Try also to check if there is a label at the triangular configuration, if none do the resistance checking
@@alieupaasewe5111 Use an ohm meter to measure resistance between the center COMMON pin and each of the other two pins and compare to the published specifications for your compressor. For example, according to Embraco's documentation for the EM3D60HLT compressor in my GE fridge, the Start Winding Resistance should be 5.66 Ω at 25°C and the Run Winding Resistance should be 4.42 Ω at 25°C.
Idol tanong ko lng po Kung paano madetermine Ang suction at discharge pipe Ng ref compressor..may kinalas po Kasi akong sirang ref nmin..gagamitin ko compressor as air compressor..tatlo Kasi linya Ng tubo eh..tsaka Kung isaksak ko compressor ung isang pipe nagbubuga Ng langis..ok p b compressor ko?..Ang reading Ng C-R= 10.1, C-S= 38.2 at S-R= 46.9..sana po masagot mga tanong ko idol..salamat po
Mine is a defy top frizzer i bought a new thermostart when i try to install it...it blew my overload protector nd i bought the new one also but stil blew it...i suspect the motor..because it wont start when am startin it without relay
@@kadiskartemotv how would we be able to use a relay to go in this circuit? You would be the coolest man on the planet if you were able to explain this to me! I’ll try to research too
Energizing both windings for more than a few seconds will overload the compressor. The START winding should be energized only long enough to get the compressor started so the RUN winding can keep it going alone.
No you can't. On a 12v compressor the three connections are the three windings of a three phase motor. It will only run if you use a 12v 3 phase motor controller.
Because it doesn’t have the relay😂😂 the compressor isn’t meant to be run continuously the relay is there to turn the compressor on and off periodically to prevent from overheating
Good evening sir, yung ref compressor na ginawa kong pang bomba ng gulong, after using continuously for 30 mins (tried to inflate inflatable pool) uminit yung motor at di na umandar. Puede ko kaya sir irekta na lang ito? Thank you very much!
Always line 2 ung common master. same lang procedure nakatap 1 line sa run, tas 1-2 secs tanggal agad pag nag start na sa S. sundin mo lang ubg video master. Salamat sa panunuod
Sir ask ko lng po, about sa thermostat po ng refrigerator, yung papalitan ko po yung thermostat ref WDF 2 7D-EX, anu po po ba pwd ipalit nito sir, kaht anu type lng po ba basta 3 pin po okay lng po ba yun. Salamat😊
Sir tanong ko lang ilang hp kaya gagamitin kong compressor ng ref para magamit pag pintura at magamit sa pneumatic tools 1hp lang kasi meron ako dito sobrang hina 🤣
Use an ohm meter to determine which pin corresponds to C, S, R. There should be no continuity between START and RUN, and the resistance between COMMON and START vs. COMMON and RUN should align with the specifications published for your compressor.
The Embraco compressor in my GE fridge started without the capacitor, but if yours doesn't and needs the boost, then splice two wires and put the capacitor in parallel with the one that temporarily energizes the start winding.
Can you explain this on a 12v DC compressor? I am trying to bypass the on/off switch on my 12v zerobreeze mach1 and I am connecting the controller directly to power and the compressor runs for a short moment then shuts off. Below is a link to what I am working on. ruclips.net/video/jbEaA0Ib1Sg/видео.html
You just helped me fix a super nice/free mini fridge! I saw it on the side of the road in a super nice neighborhood with a free sign and hoped that it would work, I was disappointed when I heard the click of the overload switch kick on. I tested for continuity and it was on all 3 poles and also no short to ground. Also tested amperage of the pull and it was well below short. Bypassed the relay like you showed and boom! Compressor rolling perfect and nice cold fridge.
Thought it was shitty that the rich bastard put a broken fridge out and just put free without "need tlc" or "needs to be fixed". They knew it didn't work and could have taken it to be recycled, but I am glad they didn't ☺. Their loss is my gain. Replacement relay costs 7 bucks and will be here in 2 days!
Thank you for wataching ❤
Thank you so much for this video. I have an old Frigidaire freezer and the genuine controler relay is discontinued from Frigidaire but worst it is that absolutly unavailable in the aftermarket. So far with your video I was able to start the freezer and save the food inside. I leave it work until it stop then make the contact (as shown) to restart it. I have ordered online another relay (look alike) and according to your indications I should be able to plug it on the compressor and fix this problem. Thanks again.
the best video... it helped me to temporary start my refregerator while looking for start relay replacement
Thanks for the Video. Best tutorial I've found on the Internet. Really helped me a lot.
Thanks for watching dont forget to like the video. 🙂
Thank you for the video! I made the harness to bypass my relay/capacitor and determined that something that I had no business trying to fix had died.
Thanks you very much Sir! After a long time looking I finally came across a discarded fridge which I was able to salavge the compressor from, and thanks to your video I just tested it and it works perfectly. I'll sort it out with a momentary switch for a quick start and it will be ready to get into work helping me in the shop.
Thaks for watching
This is good information to know if you are waiting on a new relay and got food in the fridge. I turned my freezer to max so it will stay colder longer between jump starting it. Also filled up some Tupperware containers with water so they turn into big blocks of ice. thanks for this info
Thanks for watching
Thaks for watching
This video was super helpful. Thank you for helping me save a GE refrigerator!
Video is for testing only, please Buy relay at the nearest refrigeration and airconditioning shop
@@kadiskartemotv Of course! Your video helped me rule out compressor failure, diagnose the problem as a failed Time Start Device, and implement a temporary workaround to avoid spoiled food pending replacement. I installed the new TSD today and the refrigerator now works perfectly. Thank you again!
Galing mong turo boss..napakalinaw
Thanks for watching master
Hi, thanks for the video. I have a question. In the uk you have live, neutral and ground which one of these wires do I connect to the common pin?. Thanks
common pin can be connected to your neutral wire :)
@@ElektroySoundsmusic Thank you
When you say "could be" can the live be connected instead of the neutral. Thanks again.
Yes,
Very good explanation. Greetings from creators from Indonesia. And always success
Thank you for watching
Excellent video. Appreciate your help sir.
Thank you for watching
That was great ! A switch tho would be nice …. Subbed as well
Thanks a lot dude worked well.searched and lokked for lots of videos.but only this worked.i have a questoion.bcs if there is a power cut we must always connect and disconnect that wire what if i put a switch to it
Great idea!
@@kadiskartemotv p
Thanks a lot being searching for it👍you got a new subscribe here
Thanks for watching
Is it neutral line that you connected to the run and start pins?
Yap,
So after star you will disconnecte that extra wire is it?
Yes . common and run will remain
After 20+ videos I found this one about my fridge compressor. I was minutes away from hotwiring it and then it kicked back on. Shot always happens the day after you buy 500$ worth of grocery’s.
Thank you for watching
Thankyou sir
Very nice and good
Thanks for watching
hey were does the hot wire go and were exactly does the neutral wire goes just to be on the safe side thanks
Just follow the tutorial, live or hot wire is the same
The hot wire goes to the middle COMMON pin, the neutral wire goes to the right RUN pin, and the wire spliced into that neutral wire goes temporarily to the left START pin.
does it automatically mean the run and start motor is opposite from the one you demonstrated?
There is marking of (C) Common (S) Start (R) Run in the compressor
Thanks for the video
Thanks for watching
hey, thks for the vid. Btw we need a capacitor?
No need sir
oh great! But my compressor just hums and doesn't turn. what to do? if there is capacitor then we can try changing it but there is no cap for it.
If you follow the step on the vid then it only hums,.most probably the motor compressor is stack up
Don't we need a 2nd phase to start it?
very simple thank you
Thank you for watching
Very informative. Thank you
Thanks for the like and watching
My firdge have a capacitor near the compressor. Would this work without the capacitor connected in some way ?
It will not, starting capacitor is important for the optimal performance of compressor, capacitor is very cheap to buy
The compressor in my GE fridge started without the capacitor, but if yours doesn't and needs the boost, then splice two wires and put the capacitor in parallel with the one that temporarily energizes the start winding.
By 'common' do you mean the hot ac line or the neutral ?
Either of the two, but its better to use the live ot hot wire
i tried this on a wine cooler thats not working and the compressor turned on after connecting hot wires to just the common (top prong) and Run (right prong). I did not have to to touch the Start. Does this mean the compressor is bad?
If the compressor produces pressure, then it merely managed to start without the second winding being energized.
thanks zir but can do this jop wile compressor in frige
Yes, simply unplug the fridge, make all three connections as described (COMMON, RUN, START), plug in the fridge, and remove the splice wire from the START pin as soon as the compressor starts. Just keep in mind that a) there is no external overload protection (as is typical with a Time Start Device / TSD) and b) when the thermostat sees a low enough temperature, it will cut power to the compressor (normal behavior), but when the temperature rises and it sends power to the compressor again, the RUN winding will be energized but the START winding won't (abnormal behavior), which could damage the compressor. So, when the fridge turns off the compressor, it's best to unplug the fridge, disconnect all wires from the compressor, plug in the fridge, and restart the compressor manually later when you hear the fridge start up the evaporator fan.
Sir yung start at run. Nong denerecta ko sa line.nka fix yung spilceng.bigla nlng umosok sa loob ng compresor.ano dapt gawi sa susunod na conection ko
Para dina magkamali.
ka diskarte idol, tanung ko lang halimbawa kpag mag-vacuum dba sa access valve ang connection, saan ang hinihigop nun yung discharge o suction line??reverse ba cycle nya opposite sa cycle ng compressor? ty
Sa suction line po ang hinihigop. Intake sa suction at discharge naman sa discharge line. Continues flow/cycle . Salamat po sa panunuod. Wag kalimutang ilikenm ang video
Does this work on the newer type inverter compressor?
No this will not work.n
can i use only capacitor, no need ptc , i try turn on compresor use capacitor , result is working properly , this way can damage compresor?
No. PTC relay will automaticaly energize the compressor without our supervision, doing so will over heat the compressor, as common and run is only needed once once compressor reach atleast 1/4 of its speed,
use the method shown on the video,just for testing, not recommend for prolong use as the compressor turns off and on when the thermostat gives signal
Sir how about a compressor with potential type relay and run/start capacitor . . Do the procedure is still the same .. tnxs
My compressor started without the capacitor, but if yours doesn't and needs the boost, then splice two wires and put the capacitor in parallel with the one that temporarily energizes the start winding.
bro. thanks. so does this mean sira na ang start relay?
Thank you Sir.This is my question to you Sir,do the run and start change position?Or the start always on the left and the run always on right?
Mostly Start is always at left and Run is at right. Try also to check if there is a label at the triangular configuration, if none do the resistance checking
@@kadiskartemotvThank you,but how can I do the resistance check?
Will make video of it
@@kadiskartemotv Thank Sir.I looking forward to it.
@@alieupaasewe5111 Use an ohm meter to measure resistance between the center COMMON pin and each of the other two pins and compare to the published specifications for your compressor. For example, according to Embraco's documentation for the EM3D60HLT compressor in my GE fridge, the Start Winding Resistance should be 5.66 Ω at 25°C and the Run Winding Resistance should be 4.42 Ω at 25°C.
Idol tanong ko lng po Kung paano madetermine Ang suction at discharge pipe Ng ref compressor..may kinalas po Kasi akong sirang ref nmin..gagamitin ko compressor as air compressor..tatlo Kasi linya Ng tubo eh..tsaka Kung isaksak ko compressor ung isang pipe nagbubuga Ng langis..ok p b compressor ko?..Ang reading Ng C-R= 10.1, C-S= 38.2 at S-R= 46.9..sana po masagot mga tanong ko idol..salamat po
Hello i have using my fridge withou relay so the motor wont start what seems to be the problem??
Check the overload protector also or the thermostat,or defrost timer
Mine is a defy top frizzer i bought a new thermostart when i try to install it...it blew my overload protector nd i bought the new one also but stil blew it...i suspect the motor..because it wont start when am startin it without relay
Can we use every day like this ?
No, it will just cause you time trouble, just buy a relay and problem will be fixed
@@kadiskartemotv how would we be able to use a relay to go in this circuit? You would be the coolest man on the planet if you were able to explain this to me! I’ll try to research too
@@toddb6266 Just buy a Time Start Device (TSD) that plugs into your compressor.
Boss ask lang po ako bakit binunot mo yong isang wire after 2 seconds. Ano posibling cause if di bunutin
Pro po pag may relay need din po bang bunotin or di na. Ano po connection if may relay na
Energizing both windings for more than a few seconds will overload the compressor. The START winding should be energized only long enough to get the compressor started so the RUN winding can keep it going alone.
Can you do the same test with a 12v compressor
No you can't. On a 12v compressor the three connections are the three windings of a three phase motor. It will only run if you use a 12v 3 phase motor controller.
Another queston why is the compressor overheating
Because it doesn’t have the relay😂😂 the compressor isn’t meant to be run continuously the relay is there to turn the compressor on and off periodically to prevent from overheating
Thermostat will do the work
@@kadiskartemotv but the thermostat is connected to the relay and the relay then controls the compressor
Thermostat = brain of the system
So that means the Common is connected to the active and Run is connected to the Neutral with Start looping in it
Yes.. just try to follow the video
Can i run my fridge like this
no its just for testing, relay is very cheap you can buy online
Good evening sir, yung ref compressor na ginawa kong pang bomba ng gulong, after using continuously for 30 mins (tried to inflate inflatable pool) uminit yung motor at di na umandar. Puede ko kaya sir irekta na lang ito? Thank you very much!
Lagyan mo lift kapag sa mga gulong sir. At kapag sa mga inflatable pools maliit masyado ung volume ng hangin galing sa compressor.
Wag po irekta delikado po yan. Dapat dadaan parin sa OVERLOAD protector. Para safe tayo
@@kadiskartemotv sir, bakit kaya ayaw nang umandar? Pay plug ko andar lang saglit tapos off na. Di po kaya naubusan ng oil. Thank you!
Check nyu po baka nag hihigh ampere ang compressor palit relay. Kapag pinalitan relay magchange OLP na tayu bala weak na
@@kadiskartemotv thank you very much sir! Ingat kayo dyan! ECQ tayo ulit!
I already try this but the common terminal had become low in reading or low amp.from 56 become 30.
Ano po kaya ang sira ng ref ko,bigl nlng sya namatay ang ilaw . tas dna po nalamig
Check po relay,OLP,thermostat
Sir paano pinning nung isang type? Yung nsa baba ang common?
Always line 2 ung common master. same lang procedure nakatap 1 line sa run, tas 1-2 secs tanggal agad pag nag start na sa S. sundin mo lang ubg video master. Salamat sa panunuod
Paano po gamitin ang ref . Compressor to air compressor ,pwedi ba yan sir ang tanke ay pang 2hr. Power
Tanong ko lang sir kung pwedeng start capacitor ang ikabit ko instead na relay.
Jejerk mo lang ba sir?
Boss.. Kung mai capacitor? Parallel ko nlang ba sa line.?
Pm ka messenser ko send ko sayo connection
DLRE ESCOBEDO ung dalawang bata ang pic. Hindi basta2 yan bawal magkamali
The capacitor should be in parallel with the wire that temporarily energizes the start winding.
Nag aayos kaba ng freezer
If this doesn't work does it mean the compressor is dead?
most probably, stuck up compressor
@@kadiskartemotv thanks for your response.
Sir ung po bang Line 1 ) is ung Live ? And then ung line 2 is for Ground thank you
Yes po,
LINE 1 LIVE AT YUNG LINE 2 IS NEUTRAL
Wala po bang problema kung mabaligtad ung Line 1 or Line 2
!
Sir ask ko lng po, about sa thermostat po ng refrigerator, yung papalitan ko po yung thermostat ref WDF 2 7D-EX, anu po po ba pwd ipalit nito sir, kaht anu type lng po ba basta 3 pin po okay lng po ba yun. Salamat😊
Ang pinaka recomend ko po ay isama sa shop ung sample, at kung paano mag replace .. ito po ung video tutorial ruclips.net/video/TBT1cHtTa48/видео.html
why my compressor is running without tapping the starting
Salamat
Hindi ba masusunog ang motor pag tuloy2 ang andar boss?
Depende kung gaano katagal.master pero kayang umandar niyan 15hrs tuloy tuloy. Salamat sa panunuod
@@kadiskartemotv salamat master. Pag direct ung wiring to 220 kahit wala ng capacitor at thermo protector ok lang ba yan.?
May mga compressor po na need ng capacitor, kaylangan po ng OLP para safe kayo against high ampere.
Gud pm po Sir’ hindi po ba mag kaka problema ung compresor kung walang “ Relay”
Depende po kung anung purpose kung bakit walang relay, dapat po may relay parin,
Sir tanong ko lang ilang hp kaya gagamitin kong compressor ng ref para magamit pag pintura at magamit sa pneumatic tools 1hp lang kasi meron ako dito sobrang hina 🤣
Gamitab mo pressure switch ang tanke master, kahit 1/3 na compressor ok na basta may tanke at pressure switch
Thanks Bro.
Thanks for watching
HELLO SIR NAGREREPAIR PO BA KAYO NG REF. SAAN PO LOC. NYO
Ilocos
Boss patulong naman, yung ref ko hindi na lumalamig, ok naman yung RELAY OLP THERMOSTAT. ano po ang sira boss? Salamat. Sana mabasa mo.
Kapag ok po ang electrical section tulad ng mga nabanggit. Maaring wala ng freon dahil may internal leak ang system,
@@kadiskartemotv maraming salamat boss, god bless
Salamat po sa panunuod. Wag kalimutang ilike ang video
Sir paano po malalaman kung wala ng freon ung ref.
Pakihanap hanap po itong video sa saating video section, paano malalaman kung wala na freon ang refrigerator
Salamat po
My compressor is no starting by this formula 😢
IF THIS DOESNT WORK PRIVBALY YOUR COMPRESSOR IS STUCK UP
Lods pano po ganyan din kasi ung ginawa ko namamatay bigla ras aandar nanaman ganun sir pano po un sana masagut🙏
First is Anu po ba scenario kung bakit natin jinerk compressor niyo?
@@kadiskartemotv ano po ung jenejerk sir biglang namamatay po kasi 5 to 10 sec umaandar nanaman sir
Jerk po is Yung wala po kayo ginamit na relay.
Jerk po is Yung wala po kayo ginamit na relay.
Magcheck po kayo ressistance ng compressor
Paano malaman sir pag wala ang csr na sign
Use an ohm meter to determine which pin corresponds to C, S, R. There should be no continuity between START and RUN, and the resistance between COMMON and START vs. COMMON and RUN should align with the specifications published for your compressor.
Sir pano Po pag may relay
Same din po
pano yung may capacitor?
The Embraco compressor in my GE fridge started without the capacitor, but if yours doesn't and needs the boost, then splice two wires and put the capacitor in parallel with the one that temporarily energizes the start winding.
Pa shot po ako ka diskarte salamat
Samalat sa panunuod master
I heard the cheekins. LOL
thanks for watching
magtagalog kana lang sir hehe
Request ng subscriber natin from bangladesh sir. Salamat sa panunuod. Wag kalimutang ilike ang video hehe
@@kadiskartemotv subscribed! more power sir
Can you explain this on a 12v DC compressor? I am trying to bypass the on/off switch on my 12v zerobreeze mach1 and I am connecting the controller directly to power and the compressor runs for a short moment then shuts off. Below is a link to what I am working on.
ruclips.net/video/jbEaA0Ib1Sg/видео.html
Hindi ba pwede magtagalog pareho Lang Naman tayong pinoy eh...
Request po yan ng foreigner natin na viewer kabayan, puro daw po kasi indiano,
Sir tagalog ka na lang.pinoy ka na man e
Request lang po nuon ng western viewer master.
seriously??? wow
Yes