Refrigerator Compressor Wiring Connections are Easy As Using Your Phone

Поделиться
HTML-код
  • Опубликовано: 23 ноя 2024

Комментарии • 191

  • @Nous3rnam3haha
    @Nous3rnam3haha Год назад +6

    Thank you for this easy to follow instructional video on how to test/check a refrigerator compressor. You helped me to understand how to see if a compressor is still good or needs to be replaced. Thank you again and keep up the great content.

  • @nexfierce4924
    @nexfierce4924 Год назад +2

    Thank you so much for sharing this information you've taught me something about the compressor on the mini fridge I just got from a friend. They said it wasn't working and that they have fixed it. However at 5 it's not getting cold enough and the refrigerator seems to be getting hot so I thought to take a look at the compressor and look on RUclips to see what was said about this refrigerator. The compressor has the three pins on the side not on the top it is protected by a box. It looks as though the wires have been chewed by something and it looks like I will soon be rewiring this compressor when I have the money. Hopefully this fixes my problem and I don't have to replace the whole compressor. For now working it just doesn't get very cold. At least I know it's a problem in the wiring back here. I wish I could take a picture to show you or send you some video.😂 I am worried because this compressor is very hot and so was the sides of the fridge. It looks like I'll be doing some work on this one. Thank you so much for being there.

    • @forevertechenglish
      @forevertechenglish  Год назад

      You can send me its photos and videos on facebook page or instagram page

  • @IqbalKhan-hc1hv
    @IqbalKhan-hc1hv Год назад +11

    I have surfed the net and find this video very helpful to determine the weak compressor. It is very informative. Thanks for uploading. Subscribed.

  • @marioalbertojimenezsanjurj3183
    @marioalbertojimenezsanjurj3183 2 года назад +8

    I am just starting to learn about refrigeration.
    And your videos are amazingly useful.
    Thank you for sharing.
    Good vibes for you from México...🇲🇽

    • @forevertechenglish
      @forevertechenglish  2 года назад +1

      Thanks and welcome

    • @jollyscaria1922
      @jollyscaria1922 Год назад +1

      Comerssar is 3terminal refaget....rs ru

    • @jollyscaria1922
      @jollyscaria1922 Год назад +1

      Ruing starting comeing point starting is power giveing ruing is one phase and netarl giveing systomes ruing ...

  • @NCMmixvlog
    @NCMmixvlog Год назад +3

    Very good tutorial, I learn this video. Thank you. Full support from Philippines. God bless.

  • @johnlabuci96
    @johnlabuci96 Год назад +2

    brilliant.. the winding diagram very helpful and you explain it very well

  • @riverbottomband
    @riverbottomband Год назад +5

    AWESOME! Thanks for teaching this. Thanks. I have subscribed for this video alone.

  • @afzaalkhan.m
    @afzaalkhan.m Год назад +1

    Very nicely clarified the pins of a compresser

  • @AbshirAxmed-o4q
    @AbshirAxmed-o4q 7 месяцев назад

    Helpful video forever I have seen experienced tutor thank you alot

  • @peltarlendori7027
    @peltarlendori7027 4 месяца назад +1

    Very good video, well explained and understandable, thank you!

  • @davyjones6387
    @davyjones6387 Год назад

    Saved my life and my fridge.Thanks

  • @kuyar.s
    @kuyar.s Год назад +1

    thank you for sharing this video sir👍👍

  • @علینارویی-غ4ن
    @علینارویی-غ4ن 8 месяцев назад +1

    Thanks for video❤❤ iamfram zahdan iran

  • @irmiyah.mshelia2974
    @irmiyah.mshelia2974 7 месяцев назад

    Very useful, thanks 🙏!

  • @tomdud1259
    @tomdud1259 10 месяцев назад

    Good morning
    Thank you in advance for the video. Individual things are explained nicely.
    Unfortunately, I can't understand some of it. Can I ask for an explanation (description from 4 minutes 19 seconds) of the entry on the left: C=R+S, R=Medium, S=Low.
    What measured values does this apply to (resistance, voltage). The description on the right side C+S=15.3 Ohm, C+R=16 Ohm, S+R=32 Ohm is super explained and clear. I just can't understand the description on the left.
    Regards

  • @bestgameplay365
    @bestgameplay365 9 месяцев назад +1

    Thanks 👍 for this helpful video

  • @RaymondPearce-s7c
    @RaymondPearce-s7c Месяц назад

    After connecting any refrigerator compressor before switching on
    Use a clamp on (amp) meter
    To check the start
    The amp reading will be higher
    To check the run
    The amp reading will be less then starting

  • @alimawali1443
    @alimawali1443 Год назад +1

    It is great information. Thanks indeed.

  • @WalrusHal
    @WalrusHal Год назад +4

    The freezer compartment works fine, but the fridge compartment does not cool at all.
    So I tested the compressor in accordance with your informative guide.
    M-->C=17
    S--->C=30
    S--->M=48
    I guess this means it's time to stick a pipe through the top and use the fridge as a wardrobe.

    • @forevertechenglish
      @forevertechenglish  Год назад +2

      I don't understood the values you wrote, can you elobrate further.

    • @WalrusHal
      @WalrusHal Год назад +2

      @@forevertechenglish
      There are no markings to identify the three prongs on my compressor, but the relay that plugs into the compressor is marked C, S, & M at the corresponding points. I'm assuming M is the same as R. If I were to rewrite this using your terminology:
      C + S= 30 ohms
      C + R =17 ohms
      S + R = 48 ohms
      Between C + S and C + R is a 13 ohm difference. That's bad, right?

    • @forevertechenglish
      @forevertechenglish  Год назад +1

      Your Compressor has gone bad according to the reading you mentioned

    • @WalrusHal
      @WalrusHal Год назад +2

      @@forevertechenglish Yes. It makes a high pitch squeal when starting up, too, so your video helped confirm my suspicion.

    • @andrew_koala2974
      @andrew_koala2974 Год назад +4

      When the FREEZER {compartment} is working as it should
      T%he compressor is functioning normally
      Some Eastern EU refrigerators were more advanced than
      those in the Greedy CORPORATE West - and were built with
      two compressors -
      one for the FREEZER - and
      one for the REFRIGERATOR section.
      I had one decades ago - and it was built in Yugoslavia -
      when the USSR existed
      That refrigerator.Freezer was designed and built to last -
      unlike appliances and devices today - built to last 4 years max ---
      And manufacturers only keep replacement parts for 5 years ---
      then they dump them - SO the consumer is unable to buy replacement parts
      - and is FORCED to spend their income on expensive NEW Junk.
      That is economic slavery.

  • @ramavtar89207
    @ramavtar89207 Месяц назад

    Very good 🕉️🚩🇮🇳🙏

  • @vincentvincent6116
    @vincentvincent6116 Год назад +4

    Running to common is thick gauge winding than starting winding gauge so comon to running winding ohms is less than starting winding

  • @keithburton3713
    @keithburton3713 6 месяцев назад +5

    I’ve been doing refrigeration repairs for 47 years and I never heard of a weak winding. There either open winding. Shorted winding.( internally. ). or shorted to ground. and I call that a multimeter.

    • @forevertechenglish
      @forevertechenglish  6 месяцев назад +6

      The weak winding means that the compressor starts fine and runs fine at the start, but 10-15 minutes later, the compressor heats up more than usual; sometimes, there can be electrical causes the compressor to heat up, but if the electricity is ok, the compressor still becomes so hot that it even trips the protecting thermostat, which stops the compressor. In the area where I am working, the people do not believe you when the compressor starts well and works for a few minutes. At that moment, we used the word "weak" to make them understand that the compressor is faulty.

    • @omarfew3852
      @omarfew3852 3 месяца назад

      I replaced my relay and overload and my refrigerator started working again but after a few hours it stopped working again any suggestions

    • @jollyscaria1922
      @jollyscaria1922 День назад

      High amper comeping not coot what resong

    • @keithburton3713
      @keithburton3713 14 часов назад

      @ could not understand a word you wrote what language is that?

  • @SaladMohamed-n5h
    @SaladMohamed-n5h 7 месяцев назад +1

    Many many thanks to you

  • @prabhanjanraj4381
    @prabhanjanraj4381 Год назад +1

    Good vedio respectfully❤❤❤👍🙏👌👌

  • @tk-jg2bf
    @tk-jg2bf Год назад +2

    Awesome educational video. Thank you for sharing.
    I had a Magic Chef (no short to ground, in ohms) with
    C & S = 12.1,
    C & R = 10.2,
    S & R = 17.4. What might have happened to S & R?
    Also, I believe you mentioned that adding a capacitor to the start or run winding if anyone of them happened to get weak. Do you have another video showing how to determine the proper uf to add and the wiring connection? Regards.

  • @neverwasthere
    @neverwasthere Год назад

    The windings of the compressor on my Whirlpool Fridge (1999 model) are as follows:
    C--S = 6.1 Ohms
    C--R = 1.2 Ohms
    S--R = 7.2 Ohms.
    The freezer temperatures are:
    Settings Temp
    A (left, 10 O'Clock) 14F
    B (middle, 12 O'Clock) -2.7F (recommended setting)
    C (rigfht, 2 O'Clock) -17.4F
    My fridge is working fine currently.
    Based on your teaching, my compressor is bad because the C--R value is way below 3 Ohms than the C--S value or 5X lower?

    • @barrytelesford5265
      @barrytelesford5265 Год назад

      My fridge is working fine currently'' you capacitor is working fine now. when it goes the rest will go with it

  • @lakshmananchandramohan3050
    @lakshmananchandramohan3050 Год назад

    Very clear explanation my friend, thanks

  • @dingnextstop
    @dingnextstop 10 месяцев назад

    Hi, I live on a river boat in uk and run a small mains powered undercounter fridge freezer via an inverter, as you can imagine it pulls my battery bank down quite a bit and I have to charge them regularly every day, my question is , is it possible to convert the Compressor unit to run on 12v? Thanks

  • @mirishumirishu8132
    @mirishumirishu8132 Год назад +1

    De teaching is superb🤞

  • @mixme8655
    @mixme8655 Год назад +1

    Thank you sir new subscriber

  • @padilla7019
    @padilla7019 Год назад +1

    Very important information

  • @mrbhadrashahi720
    @mrbhadrashahi720 Год назад +2

    Thank you dear sir.

  • @MrEldeanyo
    @MrEldeanyo Год назад +1

    Thank you!

  • @cfauvel
    @cfauvel 9 месяцев назад

    Cool...now what color wires go to each terminal?
    I have a guy who installed a different compressor and the pins from the old unit to the new unit are swapped. The original compressor had the single pin at the top the "new to me" compressor has the single pin at the bottom.
    It appears to be that the red wire goes to the overload protector that goes onto the lone pin.
    then I'm left with a pink and light blue wire , that goes to the relay....what color wire goes to Start and/or what color wire goes to Run?

  • @ronevergrow8319
    @ronevergrow8319 Месяц назад

    I have a question?
    Can I run a kitchen refrigerator on a home hi tech touchscreen Alexa thermostat (you see where I’m going with this 😂😁) and how do I do it? I’m thinking a remote wire straight from the home thermostat to the compressor 🤷🏽, or would I run it to the control panel/board and where do i enter/input ( I would rather bypass the panel, but leave it connected so I can run the compressor straight off the thermostat if possible) ?

  • @mathewlopez143
    @mathewlopez143 Год назад +1

    Its nice video content help alot

  • @abrahammayaiarop1191
    @abrahammayaiarop1191 Год назад +1

    very good job its really interested

  • @gechjemaljemal2857
    @gechjemaljemal2857 Год назад +1

    i learn alot tnx

  • @annmn5397
    @annmn5397 Год назад

    Is it ok to use 1/5hp compressor to replace the old one with 1/4hp (310L chest freezer)? Coz after replacement, still not freezing enough. I was told that the new compressor model (1/5hp) is equivalent to the old one (1/4hp).

  • @davisonshimunungu9608
    @davisonshimunungu9608 Год назад

    Thank yu for the detailed work but l wish to confirm if the live is called common because from other videos they refer to neutral as common

    • @forevertechenglish
      @forevertechenglish  Год назад

      Live is called common, The run terminal is neutral and start is joint with run wire, but disconnects when the compressor takes soft start.

    • @manyblue6430
      @manyblue6430 Год назад

      You said, the run terminal is neutral and Start is joint with Run wire, but disconnect when the compressor takes soft start,
      My question is, what will happen if it didn't disconnect?

  • @erjondoko9370
    @erjondoko9370 Год назад

    I have exactly the same problem with the first compressor you have shown. Which capacitor can i put and where please? Ha e you any diagram?

  • @devrishiyadav9904
    @devrishiyadav9904 Год назад +4

    too good helpful

  • @cedrickern6556
    @cedrickern6556 Год назад +1

    Very good ❤

  • @shafimehar4506
    @shafimehar4506 Год назад +1

    If we want connect running capacitor with the first one compressor..quide me the value of running capacitor. Thanks

  • @nejoh713
    @nejoh713 Год назад +4

    Dont make something easy with difficult theory. That is simple work.

    • @jollyscaria1922
      @jollyscaria1922 8 месяцев назад +1

      Comprsdor wiring pointex 230v ok teminal ok 3point ruing starting ok c comon point runing ok

    • @jollyscaria1922
      @jollyscaria1922 8 месяцев назад +1

      Diret starinv point power givd phasd one point ..rpointond powed givd same oint line startinv poing giveing conacting capciter ouf po dischargd c comon poing n.. netusl lind give saterdiret capciyef usinv satartinv pointef ok damgex comprssor replcinv firsg setup g selfy and disconnetinv and gas removeing old comprssof after line cuting or welding and remove sng methad ok renoveinv out tacking ok

  • @mavamQ
    @mavamQ 2 месяца назад

    All of the refrigerator compressors I have checked have 4Ω and 6Ω readings. These are 1/3hp compressors.

  • @nwachukwuchimankpam1687
    @nwachukwuchimankpam1687 Год назад +1

    Excellent

  • @halilarduc449
    @halilarduc449 Год назад +1

    Güzel bilgiler için teşekkür ederim

  • @navahroneentertainment8126
    @navahroneentertainment8126 Год назад +1

    I add up everything like u did in the video c+s and c+r but when I add s+r the values dont match what does that mean.

    • @forevertechenglish
      @forevertechenglish  Год назад

      When S+R don't match it means the compressor winding is bad.

  • @njlarry100
    @njlarry100 2 месяца назад +1

    What does it mean if the readings are near zero ohms on all three pins?

  • @iymind6785
    @iymind6785 Год назад +1

    Good job brother. You seam every where. HNWYS

    • @andrew_koala2974
      @andrew_koala2974 Год назад

      Seem - not Seam
      Seam = Joint consisting of a line formed by joining two pieces
      Seem = Appears to be like ----
      Read more to improve your knowledge of the English language

  • @abshiraxmed6608
    @abshiraxmed6608 2 года назад +1

    Oh dear make more videos from like this electricity

  • @RoyPerera-uq5kx
    @RoyPerera-uq5kx Год назад +1

    Excellent dimo

  • @geoffreydsouza1378
    @geoffreydsouza1378 7 месяцев назад

    Thank you sir

  • @Tiktokviralremix_2024.
    @Tiktokviralremix_2024. Год назад

    Have a nice day,,can we replace an ac compressor not same model ,,but sama LRA or the same Horse power..

  • @aprilsegura2597
    @aprilsegura2597 Год назад +1

    Thank you sir

  • @elohorolokpa
    @elohorolokpa Год назад +1

    Please, i need help here.
    C+S is 19 ohms
    C+R is 13 ohms
    S+R is 32 ohms.
    Is this compressor still good?
    Please, it's urgent i get a response.. thanks

  • @Adam90155
    @Adam90155 Год назад

    Dobry film,mam pytanie jak uruchomić sprężarkę na krótko inwentorową ?

    • @forevertechenglish
      @forevertechenglish  Год назад +1

      Zrobiłem o tym film, oto link do filmu. ruclips.net/video/GHMEl6YQV8U/видео.html

  • @LordWillyGee
    @LordWillyGee 8 месяцев назад

    Yes, My R12 Freezer Compressor after 28.6 years of great services? But I have to replace it with an R12 or R600A Compressor, both are hard to find the BTU & LRA need to match! Oh don't forget the Oil! 4 difference only the MO work in the old Freezer 21 cu-ft upright or chest! Manual Defrost Have I known it bad? Trip the breaker!

    • @LordWillyGee
      @LordWillyGee 8 месяцев назад

      Yes I try it with rco410 buzz & do nothing, rco210 it clicks, and trip the breaker

  • @FATU_G
    @FATU_G Год назад +1

    Thanks

  • @NickAnderson-rc4gt
    @NickAnderson-rc4gt Год назад +1

    I wish to know how may I switch a 220vac compressor into 12vac. How to rewind it, what wire gauge to use, etc. I wand to operate my refreg on battery without using an inverter. Is it possible?

  • @leetvlog5831
    @leetvlog5831 Год назад +1

    The common- starting is higher reading than common-running.

  • @mikejohnson7768
    @mikejohnson7768 Год назад +1

    Would like to fit a danfoss compressor in a 12 volt everchill 11 cu ft, is it possible

    • @forevertechenglish
      @forevertechenglish  Год назад

      Check the specification of the old compressor, means what is its size in its datasheet

  • @zahidmirza5072
    @zahidmirza5072 Год назад +2

    B = C
    W = S
    R = R
    Black is common

  • @paulbush7095
    @paulbush7095 Месяц назад

    For some reason when I am addressed as “friend” by someone whom I’ve never met I always think of the term “comrade”.

  • @khairulanuari5103
    @khairulanuari5103 Год назад +1

    Hi Sir, I tested the compressor accordance with your guide but the result look different
    M-->C=8.8
    S--->C=8.8
    S--->M=9
    do you know why i get this value at my compressor please. Thanks in advance

    • @forevertechenglish
      @forevertechenglish  Год назад +1

      Your Compressor Is BAd

    • @khairulanuari5103
      @khairulanuari5103 Год назад

      @@forevertechenglish im sorry i just watch few more things about compressor..the read like that its because my compressor is inverter compressor the read will be all same..

  • @darrylhamadziripi2224
    @darrylhamadziripi2224 Год назад +1

    I am not looking for resister resistance. I am looking for relay connection on a compressor

  • @Ghedi1965
    @Ghedi1965 2 года назад +1

    Thank you

  • @salmabayrot961
    @salmabayrot961 Год назад +1

    Super

  • @RaeesIsaacs-o3f
    @RaeesIsaacs-o3f 5 месяцев назад

    what size capacitor can
    i use for this

  • @aboodabdul2617
    @aboodabdul2617 Год назад +1

    Great

  • @katinukanalas
    @katinukanalas 7 месяцев назад

    Hey what is the video called where you connect the capacitor

    • @forevertechenglish
      @forevertechenglish  7 месяцев назад

      I didn't made a video on where I have connected a capacitor with a compressor.

  • @KUNHUkozhikode
    @KUNHUkozhikode Год назад +1

    Good

  • @GglSux
    @GglSux 8 месяцев назад +1

    Great Video...Unfortunately the (translated english) narration makes a "dog's breakfast" out of it... which is a bit sad..
    Possibly this can be mitigated as AI translation is getting better and better, best regards)

  • @علینارویی-غ4ن
    @علینارویی-غ4ن 8 месяцев назад +1

    Imsary my language very bad ❤ tank you very much for helping

  • @bushwackingozarks1860
    @bushwackingozarks1860 Год назад

    So what color is the common wire. I have a white one and a red one. Located in the US.

    • @andrew_koala2974
      @andrew_koala2974 Год назад

      Manufacturers unfortunately use any color they choose for that dat.
      Ther is NO Standard-
      And theU.S. is particularly recalcitrant and refuses to follow Worl/EU standard for wiring color.
      And North Americans are so brainwashed and ignorant 0= that they cannot count to 10 without
      using their fingers - BRAINWASHED TO USE IMPERIAL MEASUREMENTS --
      Only the people can FORCE change 0- but they are too dumb and too brainwashed.
      The USA committed to the metric system in 1875 by signing an international agreement.
      'LA CONFÉRENCE DI MÉTRE' in Paris [FRANCE]
      Signed by M. Ashbourne the U.S. Envoy to France
      All its units have been defined to the metric standard since then in the
      USA for Trade and Commerce.
      Search for 'THE CODE OF LAWS OF THE UNITED STATES OF AMERICA'
      §205b clause (1) states:
      To designate the metric system of measurement as the preferred system
      of weights and measures for the United States Trade and Commerce.
      Since 1994 both Metric and US customary units have been required to be
      shown on labels and packaging.

  • @oswaldmelville5939
    @oswaldmelville5939 Месяц назад

  • @ProsperNalindwanamungu
    @ProsperNalindwanamungu Год назад +1

  • @zulfiqarali3243
    @zulfiqarali3243 Год назад

    What is function of run capacitor in refrigerator please?

  • @aravindsundaresh203
    @aravindsundaresh203 2 года назад +1

    Sir I have one issue sir
    In samsung front load diamond model it run fine when without load if I make some load wash circulation it be very low rotate example whithout load it rotate 35 sec right and left. But with load it rotate only 6 sec remining time it wil ideal only I change carbon and tacho also but no use voltage are properly I get .what is the reson sir pls give any idea

    • @jollyscaria1922
      @jollyscaria1922 2 года назад

      Comprssar r power line phase starting point only second giveing power c comon N.only.

    • @aravindsundaresh203
      @aravindsundaresh203 2 года назад

      @@jollyscaria1922 sry sir I can't understand pls give some more detailed information

    • @forevertechenglish
      @forevertechenglish  2 года назад +1

      Is the Pcb fine

    • @jollyscaria1922
      @jollyscaria1922 2 года назад

      Aslom go sloved bai frige not gas tomuch bai jumping removeing alone jobe othegues helping stroey much good good rparing slove gmind usfull and gas systom working no totaly wring parts and capcter rely compant using time bred all chenking not as wer stared mind lockel us somanney unit fee not all out cretive righting ex come all out in afte new systom big eng $$s dicideing not eascy jobe tock but out side jobe mind usfull all

  • @stonedios7076
    @stonedios7076 25 дней назад

    Je suis nouvellement abonnés vous n'avez pas les vidéos en français svp

  • @Tulfonatic-sarcasticsm
    @Tulfonatic-sarcasticsm Год назад +1

    Can u put ctto?

  • @ReneZambe
    @ReneZambe Год назад

    Please i will need some compressor how can i get it

  • @jorgefelixrodriguezcardo9309
    @jorgefelixrodriguezcardo9309 Год назад

    That thing about compressors pin order is not a full true, for sure the start and run pins not always are located as you are saying in your video. Proof of that is for example de LG compresor model ND52LACH 115V/60hZ motor type CSR. In this case the commn pin wich you name as ( C ) is at the bottom but the Start Pin ( S ) is located at the top left and the Run pin ( R ) is located at the top right. So if yo conect that compresor according to your instructions, for sure you will blowup de compressor.

    • @forevertechenglish
      @forevertechenglish  Год назад

      Further In the video, I have also told, how to check the compressor terminals by checking the resistance. One can identify the terminals through the resistance values too.

  • @tbone6354
    @tbone6354 9 месяцев назад

    A helpful tip is to add 50ml of sulphuric acid to the compressor before regassing. This makes it unnecessary to flush or vacuum. The acid keeps the compressor clean.

    • @akshayoval5476
      @akshayoval5476 8 месяцев назад +1

      Wdf r u out of ur mind this will destroy the internals of the compressor 😢😢

  • @cesarorozco8795
    @cesarorozco8795 3 месяца назад

    I get 15.5 on all combinations, why?

    • @mwaseem932
      @mwaseem932 3 месяца назад

      Ur compressor is dc this method is for ac compressor

  • @vidhukrishnan5668
    @vidhukrishnan5668 Год назад

    C-S=34.4
    C-R=8.8
    S-R=43.3
    What's your opinion??

    • @shafimehar4506
      @shafimehar4506 Год назад

      Running winding too much weak.

    • @andrew_koala2974
      @andrew_koala2974 Год назад

      The R winding can be described as WEAK -
      and that means it has SHORTED TURNS.
      Thus the compressor requires replacement.
      This often happens as a result of overheating -
      and often as sporadic winding failure --
      It happens in Transformers also - It's just
      the way it is
      REPLACE THE COMPRESSOR

  • @antoniolopez-x5o
    @antoniolopez-x5o Месяц назад

    Where is the ground connections

  • @brianmccafferty1470
    @brianmccafferty1470 9 месяцев назад

    Volt tim enter ?

  • @Android_Warrior
    @Android_Warrior 2 месяца назад

    Is that the voice of AI???

  • @giovannimiceli8427
    @giovannimiceli8427 Год назад +1

    Ma perché non si traduce in italiano

  • @JamesDevassy-j3i
    @JamesDevassy-j3i 11 месяцев назад +1

    I am sorry you explained to God but don't mention the capacitor connection why?

  • @eleaskipper1980
    @eleaskipper1980 Год назад

    يا اخي لطالما تحكي وتشرح بالانكليزي , ليش تكتب عنوان الفيديو بالعربي؟؟؟!!!

  • @tnation-d28
    @tnation-d28 Год назад +1

    💤😴

  • @cesarorozco8795
    @cesarorozco8795 3 месяца назад

    PLEASE HELP.

  • @nerfarmymedic
    @nerfarmymedic 3 месяца назад +2

    I just can't trust the videos where they won't show their face and they use the canned fake voice. If they knew what they were doing they wouldn't work so hard at being anonymous, would they?

    • @forevertechenglish
      @forevertechenglish  3 месяца назад +5

      Well, this video is a dubbed version in english, the original is on another channel with a different language.

  • @Jimmyjimjimjim
    @Jimmyjimjimjim 2 дня назад

    You ripped this video from someone 😂

    • @forevertechenglish
      @forevertechenglish  2 дня назад

      nope at all, its my own creation, Just translated into english.

  • @rezababaee704
    @rezababaee704 Год назад

    !
    33

  • @TeacherDoug7
    @TeacherDoug7 8 месяцев назад

    If you're going to call your channel "Forever Tech English", you should probably learn English.

    • @forevertechenglish
      @forevertechenglish  8 месяцев назад

      Well, these are old video's which I my self feels have some mistakes grammatically. Well trying to improve day by day.

    • @forevertechenglish
      @forevertechenglish  8 месяцев назад

      Practice makes a man or either you can say the person better.

  • @giovannimiceli8427
    @giovannimiceli8427 Год назад +1

    Non si capisce un tubo