  • Опубликовано: 7 апр 2013
  • Watch this video first. The video explains how to determine the type of wiring you have, how to remove your existing thermostat, and how to install your new Wi-Fi smart thermostat if you have a C-wire. If you do not have a C-wire, you'll be directed to videos for installations with other wiring options.

Комментарии • 16

  • @lynnkvamme
    @lynnkvamme 8 лет назад

    Finally found my thermostat! Very helpful video. its not hard, but one is reluctant to do something wrong, so its great to have the video!

    • @lynnkvamme
      @lynnkvamme 8 лет назад

      No, I just had issues trying to get it open to change the battery 😊

  • @CherylNoyer
    @CherylNoyer Год назад

    i love honeywell wifi thermostats

  • @ramongarcia6996
    @ramongarcia6996 5 лет назад

    How do I add a red link outdoor lock out sensor for heat pump with this thermostat

  • @superdlucks
    @superdlucks Год назад

    Hoe do I find the mac address after the installer failed to set up my wifi?

  • @williambonney3749
    @williambonney3749 4 года назад +1

    I want to replace a Honeywell Chronotherm III with the Honeywell RTH9585WF thermostat. In the existing thermostat I have, C, R, Y, G & W2 wires. I also have E and O wires, which are connected to the thermostat. . Any idea on what they would correspond to on the RTH thermostat? The system is a Trane heat pump.

    • @Oneklickmedia
      @Oneklickmedia 8 месяцев назад

      Ever find solutions? I have the same trane and heat not coming on after I install it.
      I have 6 wires: C,W/E,G, Y, O/B and RC.

  • @Aleron82
    @Aleron82 8 лет назад

    The links mentioned in the video no longer go anywhere. I get a 404 - Page Not Found error.

  • @WarlockCore
    @WarlockCore 8 лет назад +1

    Question for anyone who can answer, I have a wire labeled RH and RC, none labeled just R , is that the same, my guess is that it is but just want to be sure, thanks

    • @romarisewilliams7429
      @romarisewilliams7429 7 лет назад

      WarlockCore did you ever get a response? I have the same issue and it looks like my RC and RH are connected then its one wire going into RH

    • @WarlockCore
      @WarlockCore 7 лет назад

      Romarise Williams hi, no I never did get a response but my guess was correct, it is the same , I installed it and works perfectly, hope that helps ):)

    • @humbertopicardi9440
      @humbertopicardi9440 6 лет назад +1

      This is an old post but just in case it helps someone. Rh (also called R) is the live wire for the 24V transformer for your heating system. Rc is the live wire for the transformer in your cooling system. If you have one wire labeled RH and another Rc (not clear from your question), connect RH to R terminal, Rc To Rc terminal AND REMOVE THE JUMPER. If you have a single wire labeled RH/RC or R, that means both your cooling system and your heating system share a single transformer. In that case connect the single wire to the R terminal AND LEAVE IN THE JUMPER AS IT COMES FROM THE FACTORY.

    • @iambigd
      @iambigd 5 лет назад

      Thanks Bert

  • @WarlockCore
    @WarlockCore 8 лет назад +1

    horrible and useless customer tech support, not only was the guy hard to understand due to not being able to speak English, he had no clue what I was talking about and just kept repeating to get a contractor, totally useless