  • @lee4741
    @lee4741 5 месяцев назад +20

    Switches are are 1200 to top of box not centre and sockets 450 to bottom of box

    • @jonathanrose456
      @jonathanrose456 5 месяцев назад

      450-1200 is the heights between which the bottom of a plug top & top of the switch will sit on the finished faceplate. The box height is important as it facilitates those heights. Switchgear including consumer units should be placed between these heights & 350mm away from corners. Exclusions apply in industrial & commercial applications where other safety concerns take precedence. The customer can also request for switchgear to be placed outside of said zones but, get a written request. Exclusions can also apply where local isolation is required for maintenance.

  • @25zerotwo
    @25zerotwo 5 месяцев назад +8

    Lights on the outside is f'ing mental. Do what the customer wants, but makes no sense at all, even with smart switches.

  • @RB-xg2vz
    @RB-xg2vz 5 месяцев назад +10

    Nick I don’t think you should belittle Adam by calling him your apprentice, he’s your minion 😂😂😂

    • @lonewolfgeoff
      @lonewolfgeoff 5 месяцев назад +4

      thought he looked a bit yellow! 😂😂😂

  • @freeitstafford
    @freeitstafford 5 месяцев назад

    I joined the dead dad club a week before christmas, it's still incredibly raw and we havent even buried the man yet. But, I hope one day to be as candid about it as you are, it's an inspiration that you are able to joke about it now, it makes me crave to be that guy, and gives me a ray of hope that it will get better. In some weird way it's actually helping me to tell people that I'm in that "club" as humour tends to be my go-to for dealing with things like bad news, illnesses and bereavement anyway (hard to at the moment though). Bravo.

    • @NBundyElectrical
      @NBundyElectrical  5 месяцев назад

      Ah mate I’m so sorry to hear ❤️ it’s shit but it gets better bud

  • @Fishbait075
    @Fishbait075 5 месяцев назад +1

    20/10 for Adams safety squint, when firing the cable stapler. Literally twice whatever the highest score could ever be!

  • @sbmorris2k6
    @sbmorris2k6 5 месяцев назад

    If you divide the remaining gap between wall and centre light by number of lights in the row that will give you your gaps for light spreads.

  • @Mattyysimpsonphotography
    @Mattyysimpsonphotography 5 месяцев назад

    "That hurt my knee because I'm over 30" is the most relatable thing you said 😢

  • @AndrewLumsden
    @AndrewLumsden 5 месяцев назад +1

    It would seem sensible to put the shaver socket at chin or at least shoulder height. - Codes permitting!

  • @MrLegend139
    @MrLegend139 5 месяцев назад +1

    I’m sorry but I had to laugh at the dad joke with Adam 😂 my missus does that to me all the time as she lost her dad 11 years ago. Her way of dealing with it I guess. Anyho great video as always Nick keep it up 👍👍

  • @firsteerr
    @firsteerr 5 месяцев назад +2

    Adam isn't "sunning himself" he is going to the pest to get wreaked and a dose of the clap ,. get in in Adam !!!!!!!!!!!

  • @andy69607
    @andy69607 5 месяцев назад

    If the floor is level, i use a piece of lath with the socket and switch hights marked...

  • @effervescence5664
    @effervescence5664 5 месяцев назад +4

    Nick it's a new build, use your 360 laser and just mark on the floor where the downlights are going, you'll be back before the finished floor is laid otherwise someone has messed up their time line for trades.

  • @scott4shell
    @scott4shell 5 месяцев назад

    Bro what size cable you putting in been on a new build site where they made the contractors Rewire the sockets in 4mm because of all the thermal insulation

  • @stephenwelham
    @stephenwelham 5 месяцев назад

    Three way switching whats wrong with dropping a twin at the first switch then loops three core between switches one,two and three job done

  • @jonathanrose456
    @jonathanrose456 5 месяцев назад

    Builder is gonna love you 😂
    OSB isn’t structural or fire rated

  • @Gjbsecurityandalarms
    @Gjbsecurityandalarms 5 месяцев назад

    What gloves you both wearing

  • @davidetherington3756
    @davidetherington3756 5 месяцев назад +1

    You'll definitely be moving those bedroom light switches in the future 😂

  • @scottsparky1
    @scottsparky1 5 месяцев назад +4

    120 top of light switch. 45 bottom of socket box

  • @timothyroper1897
    @timothyroper1897 5 месяцев назад

    you paire are a great team, nic what happend to the unilight give away??? iv been hopping for a win!!

  • @AndrewLumsden
    @AndrewLumsden 5 месяцев назад

    Mill-war-key - Simples!! 😂😂

  • @mckayrd
    @mckayrd 5 месяцев назад

    Anyone who has seen Waynes world knows its "Millie-Walk-A" as the Indians say

  • @david1977m
    @david1977m 5 месяцев назад

    @NBundyElectrical and ​​⁠​⁠@Alexander_sparky : I’m confused with this one so paused the video to check. I’m a 46 year old doing my 2365 and am confused as it’s not just you I’ve heard say grey as common on videos. However in the On-site guide pg. 95 and the IET Students guide pg. 174 it shows the black as common. Someone please let me know as were not back to college until January.

    • @sbmorris2k6
      @sbmorris2k6 5 месяцев назад

      Black as common if you do any pre flexed lighting plugs like flex 7 4core plugs come pre wired with black as em/perm

  • @Vii7aL
    @Vii7aL 5 месяцев назад

    Actually think that cable stapler slows you down, so bulky. Unless you are putting 3/4 cables in one staple I could do it faster with a hammer

  • @markdenny7324
    @markdenny7324 5 месяцев назад +1

    I work for the health and safety executive, we will be in touch regarding a few incidents in this video

  • @JoeJSE
    @JoeJSE 5 месяцев назад +1

    You lads have made me question my life as a mechanical engineer. I’m 28 years old and I’m looking to retrain. I want to be a sparky. I have booked my 18th for 3rd of April. Any advice on gaining experience and qualifications to become a competent electrician? Thanks lads 👍

    • @JoeJSE
      @JoeJSE 5 месяцев назад +1

      Also if any advice on any apprenticeships or routes into being an electrician would be greatly appreciated.

    • @simiiee
      @simiiee 5 месяцев назад

      You can do it 💪 I'm 31 only qualified. Watch all these videos and learn about testing and fault finding even watch videos on them and pay attention to concept of electricity don't just focus on first fix and second fix work. Fault finding and testing keep your mind focused on the concept of electricity and how it flows and its resistance

    • @JoeJSE
      @JoeJSE 5 месяцев назад

      @@simiiee what qualifications did you get mate? Did you go to night college? Or a apprenticeship?

  • @davidexley3110
    @davidexley3110 5 месяцев назад

    1200mm for a light switch is the maximum height to the top of the switch, not the centre of it so just put it a dry-lining box in just below the noggin.

  • @ForTheBirbs
    @ForTheBirbs 5 месяцев назад

    The dynamic duo! Two heads are better than one... Oh dear, oh dear

  • @jackisherwood7072
    @jackisherwood7072 5 месяцев назад

    (8.54) Aliens 👽

  • @edglue6138
    @edglue6138 5 месяцев назад

    If a client said they want bedroom switches on the outside of the room. I would say you couldn’t because of the regs.
    They will thank you in the end. TW@‘s

    • @anthonybragg
      @anthonybragg 5 месяцев назад

      What regs? can you explain?

  • @neilhowarth9362
    @neilhowarth9362 5 месяцев назад +1

    Why is there osb and plasterboard

  • @liviumariandavid2006
    @liviumariandavid2006 5 месяцев назад

    Hi Adam , i got a question to ask pretty simple so i work as an apprentice for a guy etc i been working for him for about 2 months and a half but I'm getting paid pretty bad for all the stuff i do in my opinion he's paying me 5£ an hour and i work for 10 hours a day total 50£ only two days a week so i was thinking of asking someone who knows more than i do should i ask him to increase my salary from 50£ a day to 65£ ? And also im 17 just to let you know 😅

    • @chrisyoung7362
      @chrisyoung7362 5 месяцев назад

      No harm in asking lad. Maybe ask "how do you think my progression is going" and "what opportunities do I have to sort of pay rises can I expect ". If it falls on deaf ears then get outa there 😂

  • @alexxxmatthews4586
    @alexxxmatthews4586 5 месяцев назад

    120 top

  • @tonywatson1412
    @tonywatson1412 5 месяцев назад +2

    When will people catch on . this led lighting in bedrooms is not good... we're obsessed with the stuff....just wait...in the future it'll go down like Mexican pine furniture... you couldn't give it away

  • @arniewheeler4673
    @arniewheeler4673 5 месяцев назад +4

    1200 max ....

  • @Alexander_sparky
    @Alexander_sparky 5 месяцев назад +2

    Grey as common?!

    • @NBundyElectrical
      @NBundyElectrical  5 месяцев назад +1

      yes mate

    • @williamcuthbertson4903
      @williamcuthbertson4903 5 месяцев назад +1

      I've never seen grey used as common, always been the black.

    • @Alexander_sparky
      @Alexander_sparky 5 месяцев назад

      I’m just winding up! Any can be used as long as it’s the same everywhere - and sleeved up Nick is a top spark 🔥🔥🔥

  • @bencrabb303
    @bencrabb303 5 месяцев назад +4

    Yeah just put the switch lower, no point faffing about

  • @O.i5
    @O.i5 5 месяцев назад +3

    As a new build electrician, i can honestly say that job between 2 people is 7 hours max, do better 🤦‍♂️ 😂

    • @SparkyUK365
      @SparkyUK365 5 месяцев назад

      7 hours 2 man I agree! thats 1 actual apprentice and 1 electrician.

    • @smellproofpirate1859
      @smellproofpirate1859 5 месяцев назад +3

      I've seen the electrics in new builds looks like they have thrown the wiring in, so yeah I'd agree with you 😂😂

    • @AndrewLumsden
      @AndrewLumsden 5 месяцев назад +2

      Most of their time is taken up doing these videos!! 😂

    • @justinHTE84
      @justinHTE84 5 месяцев назад

      @@smellproofpirate1859I was going to say the same thing 😂

    • @O.i5
      @O.i5 5 месяцев назад

      @@smellproofpirate1859 trust me it would look better than this, depends on the electrician but i actually make my work neat and to standard, and running across walls even if its in zone is a nono for longer than a half metre distance, thats just asking for a customer to put a nail in it

  • @Romeworld95
    @Romeworld95 5 месяцев назад +1

    Yeah between 450 and 1200. 1100 would suffice. Anything in-between would suffice.
    Truth is, client won't like the 1200 as they're real low. But requirements...

  • @amfcontractors
    @amfcontractors 5 месяцев назад +2

    Mans on over the 100k subscribers I’m barely on 80 lol. This stuff isn’t a walk in the park

  • @Damopatrick
    @Damopatrick 5 месяцев назад

    Wiring first fix Dali system at work with motion sensor finding it difficult as 1st year apprentice understand circuit for sensor and Dali as switch and sensor both get separate feeds from the board as it’s phase colours we can’t use different colour for sensor feed so think that is causing me get confused. 🫤