Walk in freezer getting warm

Поделиться
HTML-код
  • Опубликовано: 13 апр 2023
  • What the heck is going on here, I'm back at this same location for a very similar issue
    Please consider subscribing to my channel and follow me below
    Social Media
    Facebook profile.php?...
    Instagram / curioushvacguy
    For any inquiries please contact me at
    curioushvacguy@gmail.com

Комментарии • 17

  • @Matthew456E
    @Matthew456E Год назад

    "Summer time has finally arrived" lol back in the 50s, low 60s for high.

  • @Brisket9392
    @Brisket9392 Год назад

    That evap looks real nice. Guessing the original one was leaking from the coil and got replaced. I would have thrown a peanut on this one. We back in the low 30s in Michigan. LOL.

  • @mekyleavacadogaming7354
    @mekyleavacadogaming7354 11 месяцев назад

    Sounds like a Monday call

  • @oldmetalguy4577
    @oldmetalguy4577 Год назад +1

    All this Waygu talk has me wanting a steak.😀

  • @kurtweck2276
    @kurtweck2276 Год назад +2

    So here's an old school rule we usta use, this is so old I'm taking r12, r22, r502 stuff and it always worked with condenser fan cycling switches. What ever pressure corresponded with 105' F you set the switch to close at 25# over, and open at 5# under. Fan cycling causes head pressure to swing up and down, not good for can compressors. Gives them a short life. That compressor your working on looks like an old Copeland semihermetic. Those things were nearly bullet proof . I've seen those flipped upside down on a roof from the wind and were still running and maintaining temp.

  • @shine-cg9uf
    @shine-cg9uf Год назад +1

    ❄️💪🇺🇸👍 tough times in restaurant biz. Maybe just swap out fcs b4 fall /winter. 404a is a blend n they can show bubbles n during low load conditions.

  • @markcotter2355
    @markcotter2355 Год назад

    good job. I enjoyed the diagnostic. That is a crusty old B. hopefully they will upgrade soon.

  • @amadeusrocks4967
    @amadeusrocks4967 Год назад +1

    wago connectors do pop apart sometimes. have had issues with them

  • @bigdaddy4975
    @bigdaddy4975 6 месяцев назад

    Anytime there’s a hot box a load on the box the sight glass will flash until that temp comes down to around 45 degrees

  • @winkhvac62
    @winkhvac62 Год назад +1

    I have a call back on wego connector

  • @HVACRNorth
    @HVACRNorth Год назад

    🤘🙌

  • @juan251100
    @juan251100 Год назад

    How do you like that adjustable wrench? I’ve seen them but hesitant to buy them.

  • @R290s_biggest_fan
    @R290s_biggest_fan Год назад

    Wouldn't the efficiently be greater at night with a lower temp liquid?

  • @analogmoz
    @analogmoz Год назад

    Wagyu nuts are for effete technicians.
    I am an effete tech.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Год назад

    Put an ICM fan speed controller on it. Much better than off/on. Nothing is as good as a headmaster though. Just a thought.

  • @bigdaddy4975
    @bigdaddy4975 6 месяцев назад

    Give it 15 mins or so