Ideal Logic / Vogue No Hot Water - How To Test - Plumber

Поделиться
HTML-код
  • Опубликовано: 13 июн 2024
  • Ideal Logic No Hot Water. Ideal Vogue No Hot Water.
    How to test an ideal logic and ideal vogue.
    Today we have an engineer from Ideal Boilers to show us how to test an Ideal Logic and Ideal Vogue correctly.
    Gas Engineer from Ideal Boilers showing us how to repair boilers.
  • ХоббиХобби

Комментарии • 158

  • @AllenHart999
    @AllenHart999  3 года назад +3

    Please send your videos in WhatsApp 07725 692699 Thanks.

    • @richardpayne2456
      @richardpayne2456 3 года назад +2

      Hi Alan brilliant video need more like this for ideal logic

    • @AllenHart999
      @AllenHart999  3 года назад

      @@richardpayne2456 Thanks.

  • @rajan246
    @rajan246 Месяц назад

    I may not quit tomorrow because of this helpful video.
    Dankje

  • @andrewmason143
    @andrewmason143 3 года назад +11

    As someone who has just qualified and don't have the fault finding experience these videos are brilliant for me 👍if we can get more that would be great thanks

  • @GeeDee70
    @GeeDee70 3 года назад +1

    Your videos are so helpful allen... have used them for reference many a time. Its so much easier watching a video of how to do stuff. Opposed to reading from the manufacturers instructions.

  • @tanjirokomadoGD
    @tanjirokomadoGD 3 года назад +1

    This is great video content. I've been a gas engineer for 8yrs and do mainly installing but have never gone down the breakdown route. Now thanks to your videos I can now begin this route.
    Many thanks!

  • @smellslikethinice1107
    @smellslikethinice1107 3 года назад +1

    As per usual, and I am not tired yet of saying it....Thank you Allen, and Ideal Boilers.

  • @johnboy1232
    @johnboy1232 3 года назад +1

    The beauty of this job Allen is you learn in this job from the day you start to the day you retire . When I started it was bymetalic strips and pilot lights now you need to be electronics technician as well .

  • @britishstudio1825
    @britishstudio1825 3 года назад +1

    Great video Allen. I love your style, very professional. We want more videos on Ideal. Thank you.

  • @user-ro9vg5ii8f
    @user-ro9vg5ii8f 3 месяца назад

    Extremely good explanation!! Very professional 👏

  • @jeanstmartin2396
    @jeanstmartin2396 3 года назад +1

    Thanks for the detailed video. As a plumbing and heating technician these types of videos are very useful. I would love to see one on Viessman detailing how to test all the components.

  • @darrenclarke161
    @darrenclarke161 3 года назад +2

    Great vid as usual Allen. Love the technical ones .👏👍

  • @jayhambleton5834
    @jayhambleton5834 3 года назад +1

    Top video Allen, keep these technical ones coming 👍🏼

  • @avnishkumar9118
    @avnishkumar9118 3 года назад +1

    Great video!very informative.love to see more diagnostic videos like this.thanks

  • @jackhoskins722
    @jackhoskins722 3 года назад +2

    Great video I’m terrible with a multi meter doing a baxi course Thursday love these type of videos

  • @martynlewis4344
    @martynlewis4344 3 года назад +1

    Excellent video, thank you Alan and thank you Ideal engineer.

  • @davidrussell3890
    @davidrussell3890 3 года назад +1

    Great informative vid Love these types of instructional vids

  • @experienceb4bob
    @experienceb4bob Год назад

    Simple and brilliant video

  • @32dartsking
    @32dartsking 3 года назад +1

    very informative as always thanks Allen

  • @rhys6264
    @rhys6264 3 года назад +1

    Very good video. More videos like this would be very beneficial

  • @user-xf3en5gs2e
    @user-xf3en5gs2e 3 года назад +2

    Very nice Allen. Would be perfect to have some kind of collection of videos about most common boiler issues from your own experience and possible testing and solutions for them. Well done mate 👍

  • @jamesparry175
    @jamesparry175 3 года назад

    Another brilliant video thanks Allen

  • @carriesparks8434
    @carriesparks8434 3 года назад +1

    Brilliant Allen ...thank you

  • @all4heatinggaslimited40
    @all4heatinggaslimited40 3 года назад +1

    Thank you Allan
    For sharing

  • @michaelrose5040
    @michaelrose5040 3 года назад +1

    Great video Allen just what I need
    Thanks

  • @bluedwarf8858
    @bluedwarf8858 3 года назад +7

    It's a good idea for ideal to do this as baxi have done it for a while so would be good to know how to diagnose and fix different parts on an ideal boiler. Maybe if ideal use a camera man so the engineer can show us properly

  • @adriatikqypi9356
    @adriatikqypi9356 3 года назад +1

    Great video Alan as usual. 😀

  • @farzaneh8458
    @farzaneh8458 6 месяцев назад

    My stupid ideal combi boiler keeps doing this every couple months it’s so annoying! I have ti keep coming to this guy’s videos god bless him!

    • @ImranKhan-hz8jy
      @ImranKhan-hz8jy 3 месяца назад

      Are you engineer aswell??
      Do you repair boilers.

  • @train4905
    @train4905 Год назад

    Superb demo sir

  • @veronicahart450
    @veronicahart450 3 года назад +5

    👍 very good video Allen

    • @AllenHart999
      @AllenHart999  3 года назад +3

      Thanks, mum

    • @dando1898
      @dando1898 3 года назад +2

      You’re never too old for your mam to be proud Allen and rightly so. Top man.

  • @chriscars3578
    @chriscars3578 3 года назад +1

    An other fantastic video again Allen

  • @carlwhiston9388
    @carlwhiston9388 3 года назад +1

    Great video. Very useful info for proper testing. Good work 👌

  • @joncoke8208
    @joncoke8208 3 года назад +1

    Great video allen! Keep them coming would love to see how to test the gas valve on an ideal i24

  • @TedMcCarthy95
    @TedMcCarthy95 3 года назад +1

    Great video Alan I have been watching you for ages you are great 👌

  • @alexhaley6271
    @alexhaley6271 3 года назад +1

    Yes more fault finding allan keep up the great work 👌

  • @alondon9421
    @alondon9421 3 года назад +1

    You such a good man Allen

  • @suheilhanna873
    @suheilhanna873 3 года назад +1

    Would very appreciate this type of videos as trainees and faults finding, would love if one day could make video on the EBUS on vaillant please. .
    You are a star , very appreciate your hard work

  • @shaunhartnell2696
    @shaunhartnell2696 3 года назад +1

    Great video... keep those coming!

  • @greghepple5778
    @greghepple5778 3 года назад +1

    Excellent stuff.

  • @danfulton3426
    @danfulton3426 Год назад

    Great video

  • @luktrucking5057
    @luktrucking5057 2 года назад

    Super test please more like this!!

  • @32dartsking
    @32dartsking 3 года назад +1

    thanks great info again

  • @keithtitley9452
    @keithtitley9452 3 года назад +1

    Great tip

  • @jameshawkins5280
    @jameshawkins5280 2 года назад

    Great video used this information today top man mr ideal .

  • @davidspencer8968
    @davidspencer8968 Год назад

    Again a great vid

  • @johnlafferty5425
    @johnlafferty5425 3 года назад +1

    Great stuff Alan

  • @kamilziolkowski3099
    @kamilziolkowski3099 3 года назад +1

    You Are 🌟 star and yes please more videos thank you

  • @timothylindop484
    @timothylindop484 3 года назад +2

    Hi Allan. Once again great video, i found it interesting that he was looking for an ac voltage coming out off the flow switch? in my limited experience on other types of boilers you normally get 5v dc going into the flow sensor and if the turbine or sensor is working correctly you normally get half the voltage dc out (2.5vdc) is this just the case for ideal boilers or that type of sensor or have I got it completely wrong?
    Thanks keep up the good work 👍🏻

  • @Oleg85ful
    @Oleg85ful Год назад

    Thank you

  • @scobeno1911
    @scobeno1911 3 года назад +2

    Good vid.
    If you want to find out if the Dhw pipes are crossed just run heating for 5 seconds then open hot tap, you’ll feel cold pipe getting hot for a few seconds. Diagnosed in less time than it takes to get multimeter out.

  • @waseemkhaliq933
    @waseemkhaliq933 3 года назад +1

    Hi Allen great informative video.is their any chance of you doing similar videos but on the vaillant ecotec!!!!

  • @jasonthompson615
    @jasonthompson615 Год назад

    Exceptional

  • @MSKChess
    @MSKChess 3 года назад +1

    Yeah more diagnostic vids please!

  • @andythomson5309
    @andythomson5309 3 года назад +1

    Great video Allen , My logic 24 combi the heating flow pipe gets hot when the hot tap is running would that be the diverter valve or the flow turbine 🤔

  • @EPEBLTD
    @EPEBLTD 3 года назад +3

    Really nice video Allan
    Be nice for us trainees to see more like this on how to test different things within a boiler mainly with the common boilers
    Maybe how to test a fan on a worcester green Star or the fan on the ideal as they are a great boiler

  • @ryantomkinson776
    @ryantomkinson776 3 года назад

    Thanks 😊

  • @smalik695
    @smalik695 3 года назад +1

    Very nice 👍🏼

  • @muhammadafzalkhan2278
    @muhammadafzalkhan2278 2 года назад +1

    Thanks

  • @grahamknox9626
    @grahamknox9626 3 года назад +1

    Will the boiler regulate the heat engine depending on a lower/higher voltage/hz signal or is the signal simply an on/off ‘switch’ with heat then regulated by the thermistors in the boiler? Thanks

  • @jeremywithers3879
    @jeremywithers3879 3 года назад

    Thankyou for this video, replaced a turbine today. My god it was tight to release the turbine from its housing at one point I thought it ain't going to move, but got it out eventually. New one in, water on job done.

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      Did you diagnose the fault using this video?

    • @AllenHart999
      @AllenHart999  3 года назад

      Thanks very much for your comment, please consider subscribing to support the channel 🙂

  • @easternise
    @easternise 2 года назад +1

    Which heat plate exchanger is easier to access, ideal logic (not vogue) vs Worcester junior greenstar. Thank you.

  • @SalimKhan-gk1fh
    @SalimKhan-gk1fh 3 года назад +1

    It’s virtually the same flow sensor as the viessmann 050 model boiler
    thankfully ideal boilers have switched over to grundfos quality water housings now so we should see no more problems!

  • @TheFazpatel
    @TheFazpatel 3 года назад +2

    Got a give 5start to ideal for efforts they put into to support and training they provide to installer

  • @leejones6579
    @leejones6579 3 года назад +1

    When checking voltage going back to turbine you changed from dc to ac voltage, is this the same for othe makes of boiler. Awesome video 👍

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      I would say that no, they are would work slightly different and have different voltage readings back to the boiler. But the main principles are the same, you would have to call the technical line and get the info from them.

  • @aliones
    @aliones 3 года назад +2

    is that your workshop?
    you have a lot of videos with boilers hanging on osb walls.

  • @johnburns4017
    @johnburns4017 3 года назад +1

    Great vid. Two components, a flow turbine and a hall sensor. A but. How do you determine if the turbine or the hall sensor is defective? Obvious once you know. The new to this may do a wrong diagnosis.

    • @kevincranfield5235
      @kevincranfield5235 3 года назад +1

      If your getting a Hz frequency signal, a stable one, but you are not getting the AC voltage back to the pub then you probably have a bad Hall sensor, Also if you pass a magnet over the Hall sensor back and to quickly it should activate the Boiler, if it does not then it is probably faulty, I wanted to keep it simple and not shove too much info in the vid. There is always more you can do but the basics are all in there.

  • @WoodomainJeremyBroun
    @WoodomainJeremyBroun Год назад

    Its not clear what you ar referring to at 1:20 - floater..?.sensor?

  • @robertdowling7620
    @robertdowling7620 2 года назад

    This is what's happening to mine I have to turn bath tap and sink on then off sometime it works but takes ages to go blue with d

  • @markcliff9923
    @markcliff9923 3 года назад +1

    Excellent video again Allen, Ideal really have upped their game since the Isar and Icos days, terrible appliances👍

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Very easy to change that as well. The first one I have done.

    • @johnboy1232
      @johnboy1232 3 года назад

      The isar and it's brothers and sisters were without doubt the worst boilers of there type .I retired three years after the logic and they were starting to show the same repetitive faults like popping heat exchangers etc.

  • @georgiangelov2764
    @georgiangelov2764 2 года назад

    Hi I have ideal boiler esp1 35. My boiler is 3 years old and I head engineer twice already. First time he come when the boiler was brand new we move into the property and the water was giving. The engineer coming in with new pump. Open the box in the property and he realise this is a wrong pump. He go back to the van and straight away come back with already openbox. Second time the same problem and engineer and you've done exactly open the box in the property and realise this is the wrong pump go out and come back with open box. And this is engineer with 20-years experience. And now I haven't exactly the same problem. I just wanted to find out how many types of water pumps have for this thank you

  • @Lutonman2010
    @Lutonman2010 3 года назад +7

    Here’s another tip for guys just starting out on fault finding. This video shows the later composite water set on a Logic. The models before used a brass water set and the Hall effect sensor clips on. This older hall sensor has a small red LED built into it. Each pulse of the magnet rotation causes the led to light. If the turbine is spinning correctly with a decent flow demand, these pulses should made the led seem continuously lit. If you see this led flashing at all whilst the tap is turned on, there’s a very good chance the turbine is sticking. Hope this helps someone one day!

    • @obuchalki
      @obuchalki 2 года назад

      Did you mean if led not flashing at all?

    • @Lutonman2010
      @Lutonman2010 2 года назад

      @@obuchalki hi. If the turbine is jammed then the LED will not light at all. If the LED seems to flicker on and off then there’s a good chance the turbine isn’t freely rotating but not completely stuck. If the turbine is ok then the pulses of the LED will be so fast that it will look like it’s continuously lit. 👍🏻

    • @obuchalki
      @obuchalki 2 года назад +1

      @@Lutonman2010 yes, so far i know. I mentiones as in your previos reply is saying if led does, instead of doesn't.
      But in my case exactly led is flashing regularly and change frequency accordind hot water tap position. But boiler not igniting. However CH is working fine and ignition get on and off in time

    • @Lutonman2010
      @Lutonman2010 2 года назад

      @@obuchalki could be a pcb issue/stat issue if you’ve ruled out the turbine/hall sensor. If you call ideal tech then they can get you to check the voltage on the board from the hall sensor. I can’t remember which terminals you have to check. I think on that model it’s on the DC side.

    • @obuchalki
      @obuchalki 2 года назад

      @@Lutonman2010 i found terminals from manual. Do you think possible that pcb doesn't receive signal from hall sensor, if sensor led is flashing?

  • @davidb2464
    @davidb2464 3 года назад +1

    Hi Allen, are all of these parameters in the MI's accompanying the boiler, or would we be calling their techy's?

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      I could be wrong because I don’t read the instructions left with the boiler, but I don’t think you get really in-depth readings measurements in them, technical helpline will give you all that you need though,

    • @davidb2464
      @davidb2464 3 года назад

      @@kevincranfield5235 Hi Kevin, that's what I thought, I've got a copy of one of the MI's, and most things are the basics, but also informative. The good thing is, the tech guys on all of these boilers are really helpful, and they give the dogs b's of info most of the time.

  • @colinfleming2244
    @colinfleming2244 3 года назад +1

    What you think of new logics with the plastic front covers just think they're going to break at hinges at top over time wonder how much to replace it. Better tell anyone got one not to lean to hard on it🤔🤔🤔

    • @AllenHart999
      @AllenHart999  3 года назад

      Colin fleming They seem a lot better than the ones of the Baxi TBH

    • @colinfleming2244
      @colinfleming2244 3 года назад

      @@AllenHart999 never seen the baxi one yet something to look out for

  • @TheDickPuller
    @TheDickPuller 3 года назад +1

    Very informative Allen. However, I maybe colour blind or missed something, but the guy from Ideal said Black wire several times, I can’t see a Black wire at the Hall sensor or PCB?!!

    • @kevincranfield5235
      @kevincranfield5235 3 года назад +1

      It is black with a green stripe on it, maybe should have mentioned that.

    • @TheDickPuller
      @TheDickPuller 3 года назад

      Kevin Cranfield Thanks Kevin👍👍👍👍

  • @faridratni6799
    @faridratni6799 3 года назад +2

    Thank you is the cable was testing red and green because I couldn't see the BLACK cable or is it my eyes

    • @AllenHart999
      @AllenHart999  3 года назад +1

      I will check next time i do one. Thanks.

    • @davidb2464
      @davidb2464 3 года назад

      Yeah, I thought it was green, but at the PCB, it did look black, strange!!!

  • @g5lak
    @g5lak 3 года назад +1

    Hi mate I have this new boiler September2019 the radiator are working but no hot water coming out of the taps

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Give ideal a call as it will be under warranty. Thanks.

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      You will have turned off the cold water inlet valve when topping up the pressure. Second valve in front the right, blue handle, pull in down and all should be o.k.

  • @lickopotamusslurperton1944
    @lickopotamusslurperton1944 3 года назад +1

    How important is it to get the best multimeters in these jobs? Flukes aren't cheap. Can you get by with a budget multimeter?

    • @AllenHart999
      @AllenHart999  3 года назад +1

      I am not sure. I would only buy good quality multimeters myself. Thanks.

    • @TheRantyMan
      @TheRantyMan 3 года назад +2

      Check out john Wards video on multimeters.

  • @johnburns4017
    @johnburns4017 3 года назад +1

    Multi meters that measure Hz are usually _expensive._

  • @ryanharding6926
    @ryanharding6926 3 года назад +1

    Hi guys, I was changing one of these yesterday but the clip was from the bottom not the side of the turbine and I broke the clip and the wires actually came out of it. that's the first time I've ever done this but I'm sure I'm not the first, is this fixable? really not sure where you would get a replacement clip head its never something you think about until it happens. any help would be really appreciated guys thank you

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      If what your saying is true, you must be talking about a different boiler than an ideal logic, as the clip only goes into the top and i find it hard to believe e that you broke the metal clip, that would take some doing. Can you confirm the make and model of the boiler and exactly what you mean by the clip broken and wires damaged

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      Unless your talking about the wiring harness connection?

    • @ryanharding6926
      @ryanharding6926 3 года назад

      @@kevincranfield5235 yes the wiring “clip” from the pcb board, didn’t know what else to call it as it clips in and out of the component

    • @kevincranfield5235
      @kevincranfield5235 3 года назад

      Your gonna need a new harness then pal, give me the serial number and I will give you the part number?

  • @YoutubeHero666
    @YoutubeHero666 3 года назад +3

    Is it me as I see blue red and green?

  • @aurimaspuscius7175
    @aurimaspuscius7175 Год назад

    Boiler transducer disconnected makes boiler run.
    Error 5. And F1.
    Valves working.
    System 2bars.
    Passive expansion 1.5bar.
    Where is a fault

  • @billrankin
    @billrankin 3 года назад +1

    Should be under warranty lol, good video though

  • @SuperWayneyb
    @SuperWayneyb 3 года назад +1

    👍🤓👍

  • @ImranKhan-hz8jy
    @ImranKhan-hz8jy 8 месяцев назад +1

    What if Ideal Logic boiler is giving hot water but not high temperature in the bathroom.
    I’ve come across two boilers replace all sensors but no luck
    Ending up replacing them finally.
    Can anyone tell what it could be please?

    • @AllenHart999
      @AllenHart999  7 месяцев назад +1

      Plate heat exchanger or maybe flow too high, do you set boiler.

    • @ImranKhan-hz8jy
      @ImranKhan-hz8jy 7 месяцев назад

      @@AllenHart999 thanks for replying hot plate replaced flow checked and reduced but no luck even Ideal techinical team couldn’t figure out

    • @ImranKhan-hz8jy
      @ImranKhan-hz8jy 7 месяцев назад

      What it used to do that giving high tempreature in the kitchen but low in bath room in all taps.

    • @tk4270
      @tk4270 5 месяцев назад

      Did you get this sorted. I'm having same problem after Plate heat exchanger cleaned and no fault codes.
      ​@ImranKhan-hz8jy

    • @ImranKhan-hz8jy
      @ImranKhan-hz8jy 5 месяцев назад +1

      @@tk4270 i couodnt get it sorted so finally replace the boiler but my experience says after doing all this that flow turbine is slow or rotten inside not spinning fully and Gas valve is not providing full Gas to the burner. This is the last option if you don’t get it sorted replace the boiler. But i tell you i never checked the flow turbine but you do please.

  • @manjsingh6500
    @manjsingh6500 2 года назад

    Blue red green wires on turbine. Yet blue Red black on test on pcb.

  • @sheilaglewglew131
    @sheilaglewglew131 Год назад

    A spanner is showing and FI

  • @whizzkid182
    @whizzkid182 9 месяцев назад

    I have this boiler and no water is coming out of the hot water tap, nothing, the heating still works though, so I’m stuck having cold showers 😂

    • @AllenHart999
      @AllenHart999  7 месяцев назад

      I assume you fixed it; I also assume you had tried to top it up and turned the hot off. Thanks.

  • @32dartsking
    @32dartsking 3 года назад +1

    lol looks like i watched this vid 4 months ago

  • @Gius3pp3K
    @Gius3pp3K 8 месяцев назад +1

    Poor design and parts used by Ideal

  • @sr11rami78
    @sr11rami78 7 месяцев назад +1

    I think if trainer speak a bit louder it will be much more understanable.