  • @Zanelancaster20074
    @Zanelancaster20074 Год назад +3

    I quite like this unit. The indoor and outdoor are very stylish. Good video as always!!

  • @joserosan3587
    @joserosan3587 11 месяцев назад +1

    Perfecto
    Sin palabras
    Y muchas gracias

  • @suldaancooling4207
    @suldaancooling4207 2 года назад +1

    Excellent 👌so good job my friend

  • @riley_roach
    @riley_roach 2 года назад +2

    So if the fan is still working does that automatically mean its a PCB issue? Was the fan on this unit just not working at all? Thanks!

    • @maracservices
      @maracservices  2 года назад +3

      The fan on this unit looked visually perfect. I replaced the fan motor and it hasn’t missed a beat since. You should look into “Hall effect”, and to be honest so should I but basically if these fan motors are spinning less compared to what they were originally when the unit was installed then it may trigger an E7 fault. I’d download the Daikin equip app and just measure the output on the PCB from where the fan gets plugged into. That will tell you if the board is faulty.

  • @jessedc
    @jessedc Месяц назад

    I replaced the fan motor after finding a melted connection at the back of the motor but my unit still shows the E7 error. I had a tech out and he recommended replacement of the PCB and to replace the motor again at the same time as the PCB could have damaged the new motor. Is there any way to test the new motor is fine and just replace the PCB or do I need yet a third fan motor?

    • @maracservices
      @maracservices  Месяц назад

      @@jessedc you can just test the fan motor before ordering the board.
      ruclips.net/video/JSEAsi994dc/видео.htmlsi=HQn4_2cFCJqk8z7d

  • @tckchannel4435
    @tckchannel4435 Год назад +2

    A detailed step by step repair shown in the video...What was the total cost of changing to a new condenser fan in your currency?

    • @maracservices
      @maracservices  Год назад

      The DC Fan Motor is $141.40 (list price) from Daikin. I got a trade discount but I can’t remember how much the discount was. Thanks.

  • @HailStonE999
    @HailStonE999 2 года назад +2

    In what scenario would a PCB fault to E7 with fan normal... How to check ???

    • @maracservices
      @maracservices  2 года назад +2

      In my experience, iv only ever experienced an E7 fault when the fan is faulty OR the Fan/s and the PCB is faulty together. I personally haven’t come across a scenario where the PCB is randomly producing an E7 fault without the fan having a problem.

    • @moodynewdy
      @moodynewdy 10 месяцев назад

      I had a similar experience with my Daikin 1.5 ton unit. Replacing the fan motor fixed my E7 error code. Fan motor shaft didn't spin smoothly when I tried turning it by hand after removing the fan blades from the shaft. Fortunately Daikin had a 5 year warranty on the outdoor unit built 02/2020 so cost of a replacement fan motor was covered at no cost. Getting the part was a challenge bc seemingly no one had the motor except Refrigeration United but they won't work with homeowners, instead selling to only HVAC techs.

  • @SpectraV4
    @SpectraV4 2 года назад +1

    Usually just a hall ic in there goes out of cal. Motor is fine but stil faults. Board outputs fine. Had it many times

    • @maracservices
      @maracservices  2 года назад +1

      Makes sense. To smart for its own good 👍🏻

  • @SoutheastHVAC
    @SoutheastHVAC Год назад +1

    I wish they made decent work vans in American like they do in the UK

    • @maracservices
      @maracservices  Год назад

      I love the Volkswagen transporters shape

  • @karlasilva2459
    @karlasilva2459 2 года назад +1

    I have a mabe model mini split and at first the E1 code showed up and so I just cleaned it and checked the wiring and the fan was working but now the E7 code is showing and I waited for about 2-3 minutes and the fan never turned on... could it be the same thing?

    • @maracservices
      @maracservices  2 года назад +1

      E1 means faulty outdoor PCB. E7 could be the fan motor or faulty outdoor PCB (I have another E7 video where the problem was the outdoor PCB). So without testing your Air Conditioner, it sounds like the outdoor PCB is dead and possibly the outdoor fan motor 😬

    • @karlasilva2459
      @karlasilva2459 2 года назад

      @@maracservices thank you I'll check on that and will look for your video... thank you again

  • @heriirsandy1425
    @heriirsandy1425 11 месяцев назад

    Is that a unrepairable motor?

  • @Rayray_unicornplayz567
    @Rayray_unicornplayz567 2 года назад +1

    Why is the outdoor unit not aligned?

    • @maracservices
      @maracservices  2 года назад

      Sorry what do you mean not aligned?

    • @Rayray_unicornplayz567
      @Rayray_unicornplayz567 2 года назад +1

      @@maracservices 1:48 it is not strait like most outdoor units.

    • @CT-vm4gf
      @CT-vm4gf 2 года назад +1

      The outdoor unit is level, it’s everything else that’s on an angle. Optical illusion I think.

    • @maracservices
      @maracservices  2 года назад

      @@Rayray_unicornplayz567 the outdoor unit is actually dead level. It just looks off because of the timber cladding.

    • @maracservices
      @maracservices  2 года назад

      @@CT-vm4gf exactly

  •  9 месяцев назад +1

    What motor number?

    • @maracservices
      @maracservices  9 месяцев назад

      What’s the model number of the condensing unit you’re putting it into?

    • @kingjmes01
      @kingjmes01 7 месяцев назад