Samsung HVAC Service Tools S Net Pro 2 Demonstration

Поделиться
HTML-код
  • Опубликовано: 17 окт 2024
  • YOU CAN FIND ME HERE @ .......
    Facebook / taddydigest
    RUclips / @taddydigest
    Patreon www.patreon.co....
    Instagram / taddydigest
    My Music
    CD Baby store.cdbaby.c...
    Spotify open.spotify.c...
    Amazon www.amazon.com...
    #SamsungHVAC #SamsungDVM
    Go visit my Patreon www.patreon.co...
    In the field using S net pro 2 Service software made by Samsung.
    Here is the link for the fitting you can use to attach your gauges to the service port.
    www.amazon.com...

Комментарии • 31

  • @johnnyfuller9769
    @johnnyfuller9769 2 месяца назад

    Can I use a tablet or a phone? Can you send a link to buy it? Thx

  • @paky66
    @paky66 Год назад +1

    Can you please explain how 2-line comm is used? What do you select in the software?

    • @TaddyDigest
      @TaddyDigest  Год назад +1

      Yes I have a video on that I will send you the link

    • @paky66
      @paky66 Год назад

      @@TaddyDigest Thanks in advance! I tried looking for it in your videos, but I couldn't find it

  • @rockypointhvac
    @rockypointhvac Год назад +1

    hello where can you buy the s net?

  • @kcomfortsystemshvac7060
    @kcomfortsystemshvac7060 5 лет назад +1

    Nice video,,Teddy,,,how much,,dos cost,, S- Net box whit kit cable everything,,? I do lots work in Samsung too,,,

    • @TaddyDigest
      @TaddyDigest  5 лет назад

      Samsung MIM-C02N S-Converter Service Tool For PC Connection is in the $600 range.
      A Samsung distributor should be able to help you
      Thanks for watching and commenting

  • @tfoutfou21000
    @tfoutfou21000 Месяц назад +1

    for the future people , you don't need the special Samsung box to run SNET PRO , i have been running SNET PRO for years !
    A generic RS485 to USB converter on Amazon or china do the same job perfectly well for under 10 dollars

    • @TaddyDigest
      @TaddyDigest  Месяц назад

      True that. You can go to amazon or you can go to wave share.They have a converter box that will work.That's like twenty dollars

  • @AntholynJr.Pedroza-dr2qw
    @AntholynJr.Pedroza-dr2qw 11 месяцев назад +1

    good day...boss would u mind telling where i can buy snet converter tool?

    • @TaddyDigest
      @TaddyDigest  11 месяцев назад

      Hey brother hit me up on my email tadfuller1@gmail.com

  • @nabinsilakar2441
    @nabinsilakar2441 4 года назад +1

    which websites can get s net pro 2

    • @TaddyDigest
      @TaddyDigest  4 года назад +1

      S net pro can be downloaded from samsung hvac downloads.

  • @MegaDanny561
    @MegaDanny561 5 лет назад +1

    your 05 option series is not configured (not a big deal).

    • @TaddyDigest
      @TaddyDigest  5 лет назад +1

      Thanks

    • @MegaDanny561
      @MegaDanny561 5 лет назад +1

      @@TaddyDigest Great video, the s-net have lot of options.

    • @TaddyDigest
      @TaddyDigest  5 лет назад +1

      @@MegaDanny561 thank you Danny I like using it for fan speed adjustments
      It's so much easier through SNet

    • @MegaDanny561
      @MegaDanny561 5 лет назад

      @@TaddyDigest yes i know i use the s-net almost everyday. the diagnosis is so much easier with s-net

  • @blueromeo1974
    @blueromeo1974 Год назад +2

    Nice

  • @Enigma312
    @Enigma312 4 года назад +1

    I'd like to buy the convert Samsung

    • @TaddyDigest
      @TaddyDigest  4 года назад

      I can send you one

    • @Enigma312
      @Enigma312 4 года назад

      @@TaddyDigest good how match

    • @TaddyDigest
      @TaddyDigest  4 года назад +1

      $657.00

    • @Enigma312
      @Enigma312 4 года назад +1

      @@TaddyDigest The method of paying the money and the way of shipping to Egypt

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 4 месяца назад +2

    inverter systems need to b weighed in.

    • @TaddyDigest
      @TaddyDigest  4 месяца назад

      Absolutely I agree
      And add for additional line sets and indoor coils

  • @bradgeary3467
    @bradgeary3467 2 года назад +1

    why should eva in\out temps be close together? i understand why they should not be that far apart but 5 degree????… if system is multi zone or VRF how do you check if charge is low? correct charge calculated and added at startup but there is no good way to determine if a system is low over the years if a charge issue is suspected or add gas every time ass hole came along at some point and over charged. these kinda systems are the future. has to be way to check charge. too many bad companies out there going to be screwing these systems up and manufacturer will look bad as a result if you are in a situation where charge may or may not be wrong and owner is told we can’t check charge, and we must rule it out as possibility so we want to spend all day removing a crap ton of expensive gas from your system just to see how much there is. then we want to crawl all your your building trying to get idea of pipe length and identify all your equipment to calculate how much gas there should be. then when we as service company find the charge correct or not we will keep trying to trouble shoot your system to find it was an install/ startup issue the whole time. that’s not going to work out well. 😂

    • @TaddyDigest
      @TaddyDigest  2 года назад

      I agree
      That's why it's good to stick with the company that knows what they're doing
      Most big VRF systems have software and they have a piping layout that can be printed off and kept with the equipment that shows the additional charge as well as factory charge

    • @bradgeary3467
      @bradgeary3467 2 года назад +1

      @@TaddyDigest heat recovery is becoming more and more common in residential where i’m at. We both know why it’s good to stick with a company that knows what’s up, and we both very well know that’s not always going to happen. Heck. what if an installer blows a factory charge off by stupid mistake somehow. i’ve seen it done on my own job

  • @cprcosta55
    @cprcosta55 2 года назад +1

    To power