FLAME SENSOR FLAME RECTIFICATION. EXPLAINED . TROUBLESHOOTING.

Поделиться
HTML-код
  • Опубликовано: 13 июн 2024
  • In this video I will explain how the flame sensor works. How flame rectification works. Polarity and in phase and grounding will be explained
    IMPORTANT CORRECTION. IN MINUTE 7:52 WE HAVE TO READ VOLTAGE IN PARALLEL. ONE LEAD TO FEMALE CONNECTOR AND THE OTHER LEAD TO GROUND. ( I PUT IT ON THE SPADE OF THE SENSOR, (SERIES)AND THAT WAS WRONG). IT GOES TO GROUND. IT GAVE ME THE NUMBERS I WAS LOOKING FOR BECAUSE THE ROD IS JUST A PIECE OF METAL AND THE ROD WAS GROUNDED. PLEASE MAKE NOTE OF THAT.

Комментарии • 31

  • @nowavenyone
    @nowavenyone 3 месяца назад

    Excellent... Thanks for the perfect explanation

  • @seshachary5580
    @seshachary5580 4 месяца назад

    very educative. Thank you regards

    • @alexthehandyman3494
      @alexthehandyman3494  4 месяца назад

      Thank you so much. Please don't forget to like and subscribe .

  • @vioreltorj
    @vioreltorj 6 месяцев назад

    Thank you Alex,
    You did really good explaining.Good instructor 😊

    • @alexthehandyman3494
      @alexthehandyman3494  6 месяцев назад

      thank you so much. It means a lot coming form you!! Please don't forget to like it.

  • @philspargo9543
    @philspargo9543 5 месяцев назад

    Alex,
    In minute 13:40, you are talking about microamps... You said : "a microamps is one billion of an amp".
    A microamp is ONE MILLIONTH of an amp! A microamp IS a microamp!
    Good video! Thnaks!

    • @alexthehandyman3494
      @alexthehandyman3494  5 месяцев назад

      Hey Phil. \Thanks for catching that. You are right! Thanks for your comment

  • @kevinruggerio1796
    @kevinruggerio1796 Год назад

    Nice thorough explanation, thanks for strengthening my weak areas Alex👍

    • @alexthehandyman3494
      @alexthehandyman3494  6 месяцев назад

      Thank you so much Kevin. A bit late but good hearing from you. I hope you had an awesome thanksgiving day!

  • @galote0604
    @galote0604 5 месяцев назад

    Very very good job 👏 your email 📧 thank you so much for your help!!!

  • @ryanmcananey6245
    @ryanmcananey6245 7 месяцев назад

    Wow… that was an amazing vide… very very informative

  • @claudioaguilera2947
    @claudioaguilera2947 6 месяцев назад

    Thanks Alex

  • @user-rv4me9zr1j
    @user-rv4me9zr1j 4 месяца назад

    Great video, I was just wondering what happens to the negative sine wave of the AC current after flame rectification turns AC current into pulsating DC current. I understand only the positive sine wave is allowed to pass through the flame but what happens to the negative sine wave? Thanks

    • @alexthehandyman3494
      @alexthehandyman3494  4 месяца назад

      Hello, in a regular AC you have the hot and the neutral wires. The current goes from positive to negative 60 times in a second. (sine wave) In this case in the furnace is just one path. It doesn't return to through a neutral. It dies at the control.
      That is my take. Im not an expert. Does it make sense?

    • @user-rv4me9zr1j
      @user-rv4me9zr1j 4 месяца назад

      Yeah that makes sense, thanks for the response

  • @JesicaM.
    @JesicaM. 6 месяцев назад

    I have a question about the flame sensor I have the same issue going on with my unit I wanted to know if it's dangerous to let it run like that?

    • @alexthehandyman3494
      @alexthehandyman3494  6 месяцев назад +1

      Hello Jessica, thanks for your question. The flame sensor would turn the unit off if the flame is missing or something wrong with the flame. That is a safety. Please expand on the problem you have . Be specific. Thanks

    • @JesicaM.
      @JesicaM. 6 месяцев назад

      @@alexthehandyman3494 the problem is that the the fan turns on then the flame turns on for a couple seconds then it turns off then back on I wanted to know if it's dangerous to let it run that way

    • @alexthehandyman3494
      @alexthehandyman3494  6 месяцев назад +1

      So obviously there is something wrong with the furnace . The flame sensor is doing what is suppose to do . Please have a professional fix the furnace. Better yet, why don't you clean the flame sensor is super easy. The problem might be something else but at least try.
      I might get you through the night but fix it soon.

    • @JesicaM.
      @JesicaM. 6 месяцев назад

      @@alexthehandyman3494 song My question is do you recommend me to leave the furnace unit off until it's fixed buy a professional I don't have no one that can do that for me the only option I have is to call a professional to come and clean it out but thank you so much I really appreciate for that information I will follow you

    • @alexthehandyman3494
      @alexthehandyman3494  6 месяцев назад +1

      @@JesicaM. Hello Jessica. How are you ? How is your furnace doing ?

  • @user-yu3mi9uz4s
    @user-yu3mi9uz4s 9 месяцев назад

    Hello. How can you measure current getting the current to earth like in minute 9:29 ???

    • @alexthehandyman3494
      @alexthehandyman3494  9 месяцев назад

      Hello

    • @alexthehandyman3494
      @alexthehandyman3494  9 месяцев назад

      Hello. Set your meter to micro amps. Put one lead on ground, place the other meter lead on the rod (without removing the power source to the rod )

  • @Elcosmicstar1
    @Elcosmicstar1 8 месяцев назад +2

    Hi Alex, you made a mistake, voltage is measured in parallel or acress a device, current is always measured in series because it is measureing the flow of electrons. In order to get a correct measurement, you need to remove the connector off the probe and connect the meter on the microamp scale between the probe and the connector. When you connected the meter in parallel to the probe and ground, you are actually dividing the current between the control board and the probe, so in effect, you are not measuring the current that is going through the probe but instead the current delivered by the control board. If the probe is dirty, the way you did it will make it appeared cleaned and working because you see the microamp reading. Troubleshooting will be much more difficult because someone following your steps would be of the opinion the probe is working. This did not become apparant to you only because you always cleaned your probe as a first step.

    • @alexthehandyman3494
      @alexthehandyman3494  8 месяцев назад +1

      Hello there. You are so right! IN minute 7 52 I meant to read voltage in parallel . One lead was on the female connector and the other should have been on to ground. Not on the sensor as I did. Since the sensor is just a rod and it was cleaned and it was screwed to the metal of the furnace and it was grounded . It gave me the measures I was looking for.
      even though it did it wrong. Thank you so much for catching that.!!!! Im going to make a correction on the description of the video

    • @roqueherrera8471
      @roqueherrera8471 8 месяцев назад

      I use nut driver drills can crack porcelain and vibration can crack the glow igniter too. 👍🏽. U doing fine bud

    • @alexthehandyman3494
      @alexthehandyman3494  8 месяцев назад

      valid point. thanks a lot for your input!!@@roqueherrera8471