Split Air conditioner maximum piping limit l Split AC piping l
HTML-код
- Опубликовано: 2 окт 2024
- Join this channel to get access to perks:
/ @girishshinde
We conduct HVAC Design and Maintenance related courses.
For course details & Registration please WhatsApp:- 9082044810
हम ऑनलाइन एचवीएसी डिजाइन और रखरखाव संबंधित पाठ्यक्रम संचालित करते हैं।
पाठ्यक्रम के विवरण और पंजीकरण के लिए कृपया व्हाट्सएप करें: - 9082044810
E Mail :- girishsshinde@gmail.com
#girishshinde #airconditioning #hvac
Thank you sir
Sir koi minimum distance hei kya in case of same level ??
5 meters
Minimum piping kitni honi chaiye sir, 1.5 ton split ac just upar h roof per, shayd 3-4 feet. Kya piping choti hone se b cooling km hoti h?
Girish sir kya yeh teeno method mention Kiya Gaya hai jaise ki same level par idu odu ho to kya 15 metr piping hi ho sakti hai is k upper nahi ho sakti. kya refrigeration ka flow down hoga. And more
Length jyda hogi tho Pressure drop hoga, compressor ka load badhega, oil return nahi hoga
Dear sir,
Now a days we generally use one indoor and two or more than two out door so in this case what would be the pipe length..
Example-- indoor 11TR and two outdoor of 5.5 Tr
Sir 1 ton ka ac 15 ft upar outdoor rakhna padega to kya ac cooling puri krega ya nahi
Thoda kam karega
Sir 10*12 ka room ha sunlight nahi padti uper b room bna huya ha to kya cooling Puri krega
????
First comment first like
Mera 2nd floor main flat e and 4th floor ka building hain, agar main 4th floor ka terrace main outdoor install koru to koyi problem hoga approx 30feet hitachi 1.5ton ????
vertical height 8 to 10 feet se jyda nahi honi chahiye
Ap video ki picture main to 15 meter bta rhe hain....
Pls confirm its fifteen feet or meter...
Kia same level pe rehne aur piping 20 feet se km kr k 10 feet krne se cooling behtr ho jay gi?
agar ye nahi kia to...????
matlab agar mene kam ya zyada pining kari... then what consequences can occur??????? plzzz tell me...
mene pehle jo installation ki h unme mene is calculation par dhyan nahi diya h.. ki ODU ya IDU upar h ya niche.. directly jitni copper pipe ki requirment rahi h utni laga di h... so kya dikkt aa skti h un cases me???
Ok video main explain karta hu
hame to Jane kite Splite Ac 50 & aboved foot copper piping par Ac chal rkha h & wo 5 &6 saal se thik kam kar rhe h bina utrap ke ,kya wo galate h kya ?
sir mere ac main 410 nomber gas hai or 10 fitt pipe main ashi colling kr rha tha or makening ne pipe kat kr five fitt kr dya ab colling kum ho gai hai kya karn ho sakta hai
5 Meter se kam piping nahi honi chahiye
5 MTR ???@@girishshinde
Jitna company deti hai usse niche kya ho karogey. 3 mtr se niche mat kro pipe
Namaste sir
Sir ac ka outdoor me jo contractor lagta hai plz us ke bare me btaye
Sir machine 0.75 tonnage ka hi toh
Good knowledge sir ji thank you 🙏❤️🙏
Piping 30 meter ya usage jyada hai to kya ho sakata hai dear sir
Good information
Is there any references for this phenomena??
Sir.aap ka awaz bahut slow aata hai pls.sahi kare
Bhai kam s kam kitna use kr sakte h kabhi kabhi aisa hota h sidha pipe nikal k vahi lga dete hai
5 Meter
@@girishshinde 5 metre ya 5 fit
Agar 5 meter se kam hua to kya hoga...
Ac mai kisi tarah ki dikkat aa sakti hai kya
Sir u bend kitni lenth par lagate hai
Sound not clear sir
Sir अगर पाइपिंग कम करें तो कोइ दिक्कत होगा
Should not be less that 3 meters, Less piping may leds to liquid flood back to Compressor
@@girishshinde thanks sir
Sir cassette ac ke bare me video banao
Bahot Aachya video hai sir es tarke video banao
Thank you sir
Very niece sir ❤❤❤
Sar ek daktebal ac hai outdoor pe 12000 capisity likha hai woh kitne ton ka hai
1 ton ka
Sir IDU aur ODU same lavel pe hai aur 50 meter length hai. Per metre 10g ke hisab se gas charge kiya hu. Cooling achhi aa rahi hai ..kya aise installation kar sakte hai? Agar galat hai to aage jake kya problem ho sakti hai. reply me sir thank you
split ac ki maximum piping 15 meter honi chahiye
Mera outdoor 25fit upar hay 2nd floor after that 3rd floor then roof....
Kaya prblm hoga???please help
Sir maan le jese mene new outdoor inddor liye us pe copper pipe nahi hai to Muje kese pata chale ga ki es unit me half ya couter lage ga ya 5/8 ka ya 3/8 ka lage ga plz es ke bare me batye
Out dor per flair Dekh Kar pta lag jay ga
Flare nahi jab copper hai hi nahi to flare kaha se banao ge ...outdoor ke service valve suction valve aur discharge valve se maloom chale ga...
Sundor
Very Nice sir
Thank you so much sir
Most welcome
Well done sir