AC KI COPPER PIPE LENGTH MINIMUM SIZE AUR MAXIMUM SIZE KITNA RAKHNA CHAHIYE ||AC COPPER PIPE size

Поделиться
HTML-код
  • Опубликовано: 17 мар 2023
  • AC KI COPPER PIPE LENGTH MINIMUM SIZE AUR MAXIMUM SIZE KITNA RAKHNA CHAHIYE
    Ac copper pipe length minimum size
    ac copper pipe length maximum size
    AIRCONDITION pipe
    aircon pipe length
    Ac standard pipe length
    minimum pipe length of ac
    maximum pipe length of ac
    Ac ka copper pipe kitna rakhe
    ac ko kitna lamba pipe connect karsakte hain
    ac ka copper pipe

Комментарии • 103

  • @MdEhtesham-mz3rp
    @MdEhtesham-mz3rp Год назад

    Vry informative 💫

  • @SenthilKumar-ck2rr
    @SenthilKumar-ck2rr Месяц назад

    Good information.. 👌👏

  • @moenkhan9113
    @moenkhan9113 Год назад +1

    Good information sukriya bhai jaan

  • @nawazkhan4957
    @nawazkhan4957 Год назад

    Bhai thank

  • @ashokrawat9081
    @ashokrawat9081 Год назад

    Great job Bhai 👍.

  • @mohammedabdulhafeez5514
    @mohammedabdulhafeez5514 7 месяцев назад

    very good.

    • @MrAcTech.
      @MrAcTech.  7 месяцев назад

      Many many thanks

  • @ar_p6567
    @ar_p6567 Месяц назад

    Valuable information

  • @raheeztp3158
    @raheeztp3158 Год назад

    Good information thanks 👍👍👍

  • @skasraf8002
    @skasraf8002 Год назад

    Nice vido

  • @ashpakshaikh9848
    @ashpakshaikh9848 3 месяца назад

    Assalam alaikum Bhai aap bhot acche se samjate ho Bhai please ek video ac ki piping pe banao na mejrment kar ke kese banding karte Bhai please batao

    • @MrAcTech.
      @MrAcTech.  3 месяца назад

      Walaikum assalam zaroor bhai

  • @md.shahid4305
    @md.shahid4305 Год назад

    Video ka explanations achcha tha magar baat janna hai ki pump down karna kitna sahi hai..
    Kya esse hamare compressor par asar nahi padega..

    • @MrAcTech.
      @MrAcTech.  Год назад

      pump down karne se effect toh aata
      magar apan aisa rooz rooz pump down toh nai karte na bhai
      ek baar yah do baar bhot hogaya

  • @akshayjamdade75
    @akshayjamdade75 9 месяцев назад +1

    Ac ka outdoor unit hey vo indoor ke hight se uper lagaye ya niche konsa accha hoga

    • @MrAcTech.
      @MrAcTech.  9 месяцев назад +1

      Indoor se niche lagaye

    • @akshayjamdade75
      @akshayjamdade75 9 месяцев назад

      @@MrAcTech. Usse compressor pr load nahi aayega na

  • @suhailshaikh-nc7ug
    @suhailshaikh-nc7ug Год назад

    Assalam walekum bhaiya
    Bhaiya apun Logan outdoor 30 feet height pe rakhe or indoor outdoor se 30 feet neeche rakhe to outdoor oil fekta na to apun woh U trap kitne kitne feet tak rakhna woh batao zra

    • @MrAcTech.
      @MrAcTech.  Год назад

      outdoor k paas me thoda pipe outdoor ki hight tak utha k bend maaro
      ek dum aisa pipe connect karte ki uske level me nakko rakho pipe thoda aisa upper utha k phir nicche bhejo

  • @moskhawatali
    @moskhawatali 4 месяца назад

    Assalamu alaikum warahmatullah

    • @MrAcTech.
      @MrAcTech.  4 месяца назад

      Walaikum assalam

  • @anjumalam1401
    @anjumalam1401 10 месяцев назад

    Main v ac lgane ko soch rhi konsa achha rhega 10/12 k liye. Plz suggest

    • @MrAcTech.
      @MrAcTech.  10 месяцев назад

      1 ton

    • @anjumalam1401
      @anjumalam1401 10 месяцев назад

      @@MrAcTech. Suqriya, kis company ka

    • @MrAcTech.
      @MrAcTech.  10 месяцев назад

      @@anjumalam1401 ghar k pass jiska service center ziyada ho

  • @chetangamara5737
    @chetangamara5737 3 месяца назад +1

    16foot length & 16foot wength me kitna ton ka ac sahi rahta hai bhai??

    • @MrAcTech.
      @MrAcTech.  3 месяца назад

      3 tr ka megha unit lo bhai

  • @iccheghurii
    @iccheghurii 2 месяца назад

    Mera 2nd floor main flat e and 4th floor ka building hain, agar main 4th floor ka terrace main outdoor install koru to koyi problem hoga approx 30feet hitachi 1.5ton ????

    • @MrAcTech.
      @MrAcTech.  2 месяца назад +1

      No problem chaljayega

  • @mubiaa57
    @mubiaa57 Месяц назад

    new ac 10feet pipe sy ziada jab hum length dalty hai to kia gass bhi ziada dalni parti hai k nhi? I mean 20 feet

    • @MrAcTech.
      @MrAcTech.  Месяц назад

      Bhai har ac ka alag rahta manual dekhlena ek baar

  • @dhavalkareliya7130
    @dhavalkareliya7130 Год назад

    28 foot length me cooling ka problem ata hay ? Daikin ac 1.5 ton.

  • @walty2680
    @walty2680 2 месяца назад

    Sir maine 1.5 ton Daikin ka ac liya hn, copper pipe ki thickness mm me kitni hoti hn please reply asap❤❤

    • @MrAcTech.
      @MrAcTech.  2 месяца назад

      1\2 inch and 1\4 isko mm me convert mardo

  • @muhammadmobeen5752
    @muhammadmobeen5752 Месяц назад

    Outdoor k pipe par tap ki insulation honi chaye? Main ny jis sy install karaaya os ny tap nai lagai pipe par. Bolta k ap ka outdoor par dhoop nai parti es liye koe issue nai

    • @MrAcTech.
      @MrAcTech.  Месяц назад

      Bhai request kar k thoda 100 200 ziyada doge toh kaam hojayega agar ap kisi ko aise hi bolo GE toh jitna company Wale tools aur saman Diya hai utne me hi kaam niklega na

    • @muhammadmobeen5752
      @muhammadmobeen5752 Месяц назад

      @@MrAcTech. Main ny installation ki payment pori ki box main tape b thi new AC , indoor k bilkul pechy outdoor laga, install wala ny bola ye outdoor bhot nazdik ha es liye koe issue nai, 3000 rs installment ka diya main ny,

    • @MrAcTech.
      @MrAcTech.  Месяц назад

      @@muhammadmobeen5752 accha Bhai Agar Usne bola nahi hoga toh nahi hoga agar kuch huwa toh bula k liyo khabar

    • @muhammadmobeen5752
      @muhammadmobeen5752 Месяц назад

      @@MrAcTech. Ab kiya os ko Bola ka khabar leni, bas pochna ye chaha raha agar zarori ha to ab kisi ko bol kar tape karwa lon??

  • @Webexusefour77
    @Webexusefour77 Месяц назад

    Agr pipe 80ft ho to gas zda dalti ha ya nae

  • @sagarsingharora6892
    @sagarsingharora6892 2 месяца назад

    16 foot hone se cooling me effect padega kya. Same floor two machine

  • @AmitKumar-ew6dg
    @AmitKumar-ew6dg Год назад

    Bhai mera intsa bala answer de do plz

  • @muzammilnawaz7133
    @muzammilnawaz7133 11 месяцев назад

    Sir,,,kisi room me internal piping honi h or indor unit ka measurement nhi h to kese piping karenge

    • @MrAcTech.
      @MrAcTech.  11 месяцев назад

      Kitne ton ka hai woh toh malom hoga na bhai
      Centre me laga re kha hai uske hisab se dekhlo

    • @muzammilnawaz7133
      @muzammilnawaz7133 11 месяцев назад

      @@MrAcTech. Sir 1.5 or 2 ton k ac hai

    • @MrAcTech.
      @MrAcTech.  11 месяцев назад +1

      @@muzammilnawaz7133 ac ka size dekho 45 se 42 inches rahsakta alag alag company k alag rahte bhai

  • @AdnanHaamZa--
    @AdnanHaamZa-- Год назад

    Sir mera ac installation ke time outdoor unit ke paas pinch hogya tha aur installer ne approximately 7 inch kaat kr wahi pipe laga diya issce koi problem askta hai kya matlab mera abhi pipe length hai 2.5mtr

    • @MrAcTech.
      @MrAcTech.  Год назад

      nai bhai abhi toh kuch nahi hoga

    • @AdnanHaamZa--
      @AdnanHaamZa-- Год назад

      @@MrAcTech. matlab baad main hoga kuch?

    • @MrAcTech.
      @MrAcTech.  Год назад

      @@AdnanHaamZa-- 3 metr company wale lagane k liye bolte
      ab baaz log toh ek metr bhi sahi se nahi lagate
      problem kabhi aati kabhi nahi
      asal me refrigerant cycling me aati PROBLEM us wajah se gas LEAKAGE PROBLEM aati
      yah compressor ki pumping ka bhi
      lakin apka ac me utna kuch nahi hai na
      toh chances kam HAI

    • @AdnanHaamZa--
      @AdnanHaamZa-- Год назад

      @@MrAcTech. sir pheli baat battamiz tha installer.. Dusri baat pinch dhek kr Aisa behave Kiya mano bhoot dhek liya aur bola areyyyy phele toh nahi dheka maine isshh..
      Manne Naya pipe ki mang ki firvi out door ke joint se 6-7 kaat kr jood diya usne fir😑

    • @AdnanHaamZa--
      @AdnanHaamZa-- Год назад

      @@MrAcTech. app se questions hai 6 inch kaam hone se kuch problem toh nahi hoga in future??
      Ki company se Naya 3m lagawane ka mang Karu?

  • @pramodkumar-bo2cf
    @pramodkumar-bo2cf 14 дней назад

    Mera ac cooling nahi Kar raha hai, pipe sirf 1.5 mtr hai. (R22 gas hai 2 ton ka carrier Back pressure 62 hai)
    To kya karan ho sakta hai

    • @pramodkumar-bo2cf
      @pramodkumar-bo2cf 14 дней назад

      1.5 mtr pipe to karan nahi hai

    • @MrAcTech.
      @MrAcTech.  13 дней назад

      Hosakta Bhai oil aagaya hoga pipe me

  • @aae_villian4815
    @aae_villian4815 11 месяцев назад +1

    Max pipe length 13 mtr h tabhi thand nhi kar rahi h ac lagta h

    • @MrAcTech.
      @MrAcTech.  11 месяцев назад +1

      Woh toh ac check karne per malom hoga

    • @aae_villian4815
      @aae_villian4815 11 месяцев назад

      @@MrAcTech. itne Lambe pipe mai cooling ho bhi Pati h kya

  • @way2hell984
    @way2hell984 2 месяца назад

    Bhai 4feet pipe rakh sakte kya

    • @MrAcTech.
      @MrAcTech.  2 месяца назад

      Bhai rakhne ko toh ek ft PE rakdete aur ac CHL bhi jata magar kab Kia kharabi aasakti nai bolsakte kiu k company k rules apan follow nai karre

    • @way2hell984
      @way2hell984 2 месяца назад

      Shukriya Bhai

  • @md.shahid4305
    @md.shahid4305 Год назад +1

    Magar length ka upar questions hai to phir 2.5 TR ka ac ka kya condition hona chahiye qki iska pressure bar jyada होता है..

    • @MrAcTech.
      @MrAcTech.  Год назад

      manuall book me likha hotha hai subkuch

  • @shoam0208
    @shoam0208 Месяц назад

    Bhai mera outdoor, indoor se 22 ft upar me rkha hai koi prblm to nhi hoga na warranty aur cooling me

    • @MrAcTech.
      @MrAcTech.  Месяц назад

      Bhai Agar Apne Company se installation karwaya hai tab toh nahi hona chahiye waise 22 ft chal jayega

  • @ilyaspatel2413
    @ilyaspatel2413 Месяц назад

    Bhai price bata do

  • @pzencare6966
    @pzencare6966 Месяц назад

    1.5 ton ac hai 12.5 miter pipe lgaya hai koi dikkt to ni hogi

    • @MrAcTech.
      @MrAcTech.  Месяц назад

      Bhai manual dekhlo ek baar company ne kia recommended Kia hai

    • @pzencare6966
      @pzencare6966 Месяц назад

      @@MrAcTech. manual mai kuch mantion nahi hai is bare mai

  • @aneshpatwa8477
    @aneshpatwa8477 Год назад

    Tu bhai window AC mein kya hota hai usmein bhi 3 m ka pipe lagna chahie

    • @MrAcTech.
      @MrAcTech.  Год назад

      window ac ka function alag hai
      usko alag se nanate

  • @dilshadshaikh8980
    @dilshadshaikh8980 Год назад

    Bhai price kitna hai 1 meter pipe ka

  • @subhampanda9754
    @subhampanda9754 2 месяца назад

    Plese replay 1.5 ton ac ka extra 5 meter copper pipe lag raha ha mota mota kitna cost ayega.😢

    • @MrAcTech.
      @MrAcTech.  2 месяца назад

      5000 minimum

    • @subhampanda9754
      @subhampanda9754 2 месяца назад

      @@MrAcTech. insulin and wire ka sath 5k main ho jayga

    • @MrAcTech.
      @MrAcTech.  2 месяца назад

      @@subhampanda9754 Haan Bhai thoda bhot aage peeche hosakta

    • @subhampanda9754
      @subhampanda9754 2 месяца назад

      @@MrAcTech. ok thanx a lot

  • @dhruvprajapati4469
    @dhruvprajapati4469 3 месяца назад

    Sir ac installation karva diya hai or LG company ke saath ka 10 feet pipe or extra 10 feet pipe laga to extra length hone ki vjaah se extra gas daali hogi R32 ya nahi ??

    • @MrAcTech.
      @MrAcTech.  3 месяца назад +1

      20 ft k liye extra zaroorat nahi

    • @dhruvprajapati4469
      @dhruvprajapati4469 3 месяца назад

      @@MrAcTech. thankfully to u , for good information 👏

    • @kingamitin
      @kingamitin 3 месяца назад +1

      ​@@MrAcTech.20 feat ka extra charge Kya Hai Sar

    • @MrAcTech.
      @MrAcTech.  3 месяца назад

      @@kingamitin qareeb 7 k

    • @vhubonmondal7753
      @vhubonmondal7753 2 месяца назад

      5500 may ho jayega ​@@kingamitin

  • @anasguru4451
    @anasguru4451 Месяц назад

    Bhaiya mene compressor extend karwaya 10.5 meter length he pr cooling ni ara bilkul kitna gas refill karau ye ac wala chutiya bana ra bhai help kardo

    • @MrAcTech.
      @MrAcTech.  Месяц назад

      Bhai kuch gas ka issue hoga ek baar manual dekho bolo