  • (1) Overspeed trip
    (2) Jacket Water High Temperature Alarm
    (3) Fuel Oil Leakage Alarm
    (4) L.O low pressure alarm
    (5) L.O low pressure alarm and trip
    (6) Priming fail alarm
    (7) Manual emergency stop
    Such safety alarms and trips testing can be seen in this video.
    #marineengineering #overspeed #marineengine #auxiliary
    More Videos for Auxiliary Generator Engine 👇
    AUXILIARY GENERATOR ENGINE
    • AUXILIARY GENERATOR EN...
  • НаукаНаука

Комментарии • 36

  • @user-ve1lw7qq4p
    @user-ve1lw7qq4p Месяц назад

    Thanks a lot ! Great job!

  • @ashishmishra2144
    @ashishmishra2144 5 месяцев назад +2

    As always, thanks for all efforts 🙌👌

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +2

      My pleasure !
      Please share to your marine engineers friends.
      Thanks.

    • @ashishmishra2144
      @ashishmishra2144 5 месяцев назад +2

      @@MoeMyintShein1987 Sure sir, will do the same. This is really a nice channel for a practical insight which is not given in book. Will definitely share. One suggestion from my side- If you keep interacting with people by coming yourself in camera, it will create much more impact and will increase more subscribers. much love from india

  • @user-nf3me5wj4u
    @user-nf3me5wj4u 5 месяцев назад +1

    Thank you Sir
    for sharing knownledge

  • @rupanjansaha4788
    @rupanjansaha4788 4 месяца назад

    VERY NICE ..

  • @thihakyawswar2274
    @thihakyawswar2274 4 месяца назад +1

    thanks brother

  • @zbihgtv9864
    @zbihgtv9864 Месяц назад +1

    Next boiler sir. Thank you for your video.

  • @AshiqHussain-lo1ph
    @AshiqHussain-lo1ph 5 месяцев назад +1

    Did all alaram tested while running the generator ?

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +1

      Except F.O Leakage and Manual Emergency Stop.
      (Prefer Man. Emergency Stop to be tested while engine is running.)

  • @ashishmishra2144
    @ashishmishra2144 5 месяцев назад

    Hey sir, What is the suction and discharge pressure that we usually maintain in sewage vacuum pump for 30 people STP ?

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +1

      Did you mean vacuum setting for Vacuummarator in Vacuum Toilet System?
      Clarify.

    • @ashishmishra2144
      @ashishmishra2144 5 месяцев назад

      @@MoeMyintShein1987 Sir, suction pressure, I got , cut-in we do: - 0.4 bar vacuum and Cut out we do: -0.55 bar vacuum for pressure switch.
      But what is the discharge pressure of sewage vacuum p/p to STP that we usually maintain?

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +1

      @ashishmishra2144
      One side of the pump is vacuum (negative pressure) and other side of pump is positive pressure. 😊

    • @ashishmishra2144
      @ashishmishra2144 5 месяцев назад

      @@MoeMyintShein1987 yes sir, I understood, but what positive valve we usually maintain !!

    • @MoeMyintShein1987
      @MoeMyintShein1987  4 месяца назад +1

      @ashishmishra2144
      Discharge Pressure of Vacuumarator Pump to STP (or) other points is maximum 0.3 Bar.
      Depends upon capacity (m3/hr) of Pump, discharge pressure (back pressure) can differ, slightly.

  • @ashishmishra2144
    @ashishmishra2144 5 месяцев назад +1

    Hey Sir, what is suction pressure and discharge pressure of aeration blower that we maintain in STP ?

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +1

      I didn’t see any suction pressure gauges for aeration blower.
      Depends upon Model of Plant, discharge pressure varies.
      In general, between 0.015MPa and 0.02MPa.
      For 15 to 25 persons, it is around 0.015MPa. For 40 to 65 persons, around 0.02MPa.

    • @ashishmishra2144
      @ashishmishra2144 5 месяцев назад +1

      @@MoeMyintShein1987 Sir since it is sucking engine room air. so its suction pressure should be 1 bar, is ths correct ? and thus discharge pressure should be more than 1 bar , but as you said discharge pressure is 0.015-0.02 Mpa which is less than 1 bar.. This thing i do not understood

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +1

      @ashishmishra2144
      That’s right ! It take suction from Engine room.
      Not much pressure is required for aeration of bacteria. If air pressure is higher, overflow can occurs and also fault high water level alarm can activate. If air pressure is high, force acting on each side of plant is high. (Ref. Pressure = Force / Area.)
      Safety valve is fitted and set at 0.025MPa for Discharge 0.02MPa blower.
      Pressure drops because of passing suction filter with silencer and design of impellers that are used in blower.

    • @ashishmishra2144
      @ashishmishra2144 5 месяцев назад +1

      @@MoeMyintShein1987 Okk sir, i got. Sir as suction pressure gauge is not fitted but whenever aeration blower is taking suction of engine room air, then at the time of suction- is this thing sure that suction pressure will be in negative value ?

    • @MoeMyintShein1987
      @MoeMyintShein1987  5 месяцев назад +1

      @ashishmishra2144
      Correct !!!
      Suction is negative pressure.
      That’s why you palm gets sucking from silencer when you touch.