For #2 D0 (129-140) it is perfectly ok: bits from 129 to 140 are assigned to 21 to 33.After that it continues with DO#1 (33 - ...)...I will call that a real Japanese REVERSE engineering :))) Greets from Serbia !
I really wish you would have described how you got rid of the Ethernet error you have on the screen of your video. That was the whole reason I watched the video.
I have the same fault errors PRIO-230 and PRIO-231, what did you do for fix them? I tried the same steps as you and the errors are there, even when I did the configuration.
@@Slogan6152 The R30iA controllers can have a software lock placed on Ethernet IO. It requires a reflash bought from Fanuc themselves. R30iB controllers come with Ethernet IO by default, no extra purchases.
For #2 D0 (129-140) it is perfectly ok: bits from 129 to 140 are assigned to 21 to 33.After that it continues with DO#1 (33 - ...)...I will call that a real Japanese REVERSE engineering :)))
Greets from Serbia !
Thanks! You saved me a lot of time fumbling through the menus! Keep these coming!
Glad it helped!
I really wish you would have described how you got rid of the Ethernet error you have on the screen of your video. That was the whole reason I watched the video.
Thank you for this video we were able to set up a gateway for my robots! thank you
Excellent information here. Thanks!
I have the same fault errors PRIO-230 and PRIO-231, what did you do for fix them?
I tried the same steps as you and the errors are there, even when I did the configuration.
I have the same problem, how did you solved it afterwards?
You referred to a word as if it were a byte. Words are 16 bits (2 bytes).
Yep, probably did. Thanks for the information.
Which menu on the pendant that I can add a weld control has an IP address 192.168.0.X ?
merci goat
so i tried to go to IO and look at Ethernet/IP and couldn't find it. That tab has the third option Greyed out. Any ideas how to get it to display?
Do you have one of the Ethernet IP options?
@@ericwhittaker3570 I have IO assigned to he ethernet rack, the robots ip is set, but no ability to configure the ethernet connection
@@TheShooter466 Did you ever figure this out? I'm having the same issue
@@Slogan6152 The R30iA controllers can have a software lock placed on Ethernet IO. It requires a reflash bought from Fanuc themselves. R30iB controllers come with Ethernet IO by default, no extra purchases.
I have the 30ib plus and the tp doesnt have the ethernet ip ios
Check your option list. It sounds like you don't have that option installed.
hello, im having the same problem. How do you solve it?
where do you find the router ip address
I usually get it from IT. I work in a large factory and they're the boss of that. ;)
Find out 😮
word is 16 for thoes we need that