Biasi Boiler Repair Part 2

Поделиться
HTML-код
  • Опубликовано: 25 фев 2019
  • This is part 2 of this Biasi boiler repair. In this part I replace the PCB and repaired the Gas boiler. Heatinggeeks
    Part 1 Here : • Biasi Boiler Repair. R...
    INJECTOR CLEANING TOOL.
    rover.ebay.com/...
    1) CARHARTT Tool Roll amzn.to/2yGiexO
    2) BAHCO Screwdriver with LED amzn.to/2Op5Ug1
    2)BAHCO Screwdriver without LED amzn.to/2yEhLML
    3)WERA Kraftform Kompakt Screwdriver amzn.to/2OnOe4K
    4)WERA 0.8x4x100 Flat screwdriver amzn.to/2RNcpra
    5) KNIPEX Alligator amzn.to/2RNctqU
    5)KNIPEX Cobra amzn.to/2PA5YWY
    same size as the alligator above just the “cobra” version
    6)BAHCO Spanner amzn.to/2IW3iR8
    6)BAHCO Spanner with slimline jaw amzn.to/2yHCq2i
    7)CK Wire cutters amzn.to/2RP19dW
    7)CK Wire cutters (shorter version) amzn.to/2OnJwnB
    8)KNIPEX bent long nose pliers amzn.to/2IW9uZ3
    9)TESTO 510 Digital U gauge amzn.to/2Cfz36a
    9)TESTO Bluetooth U gauge amzn.to/2IW4t30
    10)Mirror tool amzn.to/2OpKVKl
    11)Cheap as chips pick set!!! amzn.to/2OpK10o
    12)FLUKE alert volt stick amzn.to/2PxCYPF
    13)MONUMENT Tailing Spanner amzn.to/2OrypK8
    14)Tee Bar 4mm amzn.to/2yDPRAr
    15)Tee bar 2mm amzn.to/2yzbjGA
    16)Tee bar 2.5mm amzn.to/2OqqSvd
    17)Full Tee bar set amzn.to/2yAoIyk
    18)10mm ratchet spanner (flex head) amzn.to/2IWCoZ9
    19)8mm ratchet spanner (flex head) amzn.to/2IUDZP5
    20)14mm/15mm spanner amzn.to/2Aa6wgZ
    21)BAHCO small spanner amzn.to/2RRkKKH
    22)Cheap Lock knife amzn.to/2IWatZf
    23)Sharpie amzn.to/2IVrxPk
    24)Injector cleaning pins link coming soon. Review to follow.
    25)Rothenberger 18” heavy duty pipe wrench amzn.to/2ChkRd6
    These are the heat duty ones I use.
    26)Knipex (large) amzn.to/2OrgfIm
    27)BAHCO 12” (not wide jaw) amzn.to/2Aatuob
    28)Fluke 115 multimeter amzn.to/2OqaFpF
    Drain down hose amzn.to/2RM4ZEN
    Gas Tap Grease amzn.to/2SE0jRL
    Led lights for van. amzn.to/2Bh7RTQ
    Fluke 101 multimeter amzn.to/2PoLP5g
    Extech EX330 amzn.to/2AYq872
    Silicone grease amzn.to/2Rnls4F
    Fluke Twist Guard probes
    amzn.to/2CfwCz4
    Commando drills
    amzn.to/2L5f50u
    Weed Sprayer amzn.to/2Ryx1Hh
    Large LDF amzn.to/2I0ss4d
    NTC Clamps:
    amzn.to/2GVUWL5

Комментарии • 70

  • @experienceb4bob
    @experienceb4bob 2 года назад +1

    Thanks again very much to make such a great video and showing the resistors how they get loose and start causing intermittent fault...well spot and especially you are very careful with your words...no F words...so i can still watch and listen while my kid is sitting next to me....thanks for making such a useful and helpful video....god bless you

  • @umark6695
    @umark6695 5 лет назад

    Tina's channel is very good. She is a very good teacher for anyone doing their ACS.

  • @johnnysingh418
    @johnnysingh418 5 лет назад +1

    Yep I been watching Tina's channel ' she is excellent aswel as it keeps me brushed up on the theory side. Some people hate Biasi boilers" but I find they are quite durable' especially the old brass diverter ones.

    • @HeatingGeek
      @HeatingGeek  5 лет назад

      I think they are good. Tough well priced boilers. I have never fitted one though!!

  • @TheDickPuller
    @TheDickPuller 5 лет назад +1

    Thanks Ollie great one as normal, it’s good to see you showing us the painstaking task of tracing & rectifying the intermittent fault.
    Gawd knows we’ve all been there, however, it’s very satisfactory fix it.
    Ignition boards are a common problem on lots of SE(& Band B) boilers.
    One thing I’d of done, re-soldered the PCB & put the new board into van stock. Easy money on a £280 fixed price repair.....Kerching, Kerching!,,
    😎😎😎💷💷💷💷💷

    • @HeatingGeek
      @HeatingGeek  5 лет назад

      £280!!!!!! I could do with some of that!

    • @TheDickPuller
      @TheDickPuller 5 лет назад

      HeatingGeek Ollie mate, WB we’re charging that two years ago for a FP Repair & other manufacturer’s are similar. Why should we charge less than them?? You’re a very skilled engineer, charge like a Rhino fella👍👍

  • @globaltimes7
    @globaltimes7 2 года назад

    Thank you so much for putting out this video.... Bloody hell we been through so many so called specialist who advise was to just change the boiler... When the fix is so simple.... Not a diy job but know what the problem might be I can now look for someone competent to make the repair

    • @HeatingGeek
      @HeatingGeek  2 года назад

      The gas industry is full of boiler installers. :-)

    • @HeatingGeek
      @HeatingGeek  2 года назад

      Where are you based?

  • @ek6868
    @ek6868 5 лет назад

    Tanx for the upload i thaught it was the pcb,your friend tina is an excellent teacher for someone who wants to learn about the gas industry I've already subscribed👍

  • @colinfleming2244
    @colinfleming2244 4 года назад +2

    One of the probs with them ideal minis was flow switch work on ch but not hw always a slight choke in divertor valve

    • @HeatingGeek
      @HeatingGeek  4 года назад +1

      Yes, I had that several times. Sometimes changing the front of it would make it work for a while.

  • @splodders
    @splodders 4 года назад +1

    Thanks dude, you vids are awesome 👏🏼 you’re a great help.

  • @Skeletoncrew46and2
    @Skeletoncrew46and2 5 лет назад

    Tina channle is great,if your renewing your gas safe licence or for newbys! Top lady tina keep em coming.😁

  • @Razz60
    @Razz60 5 лет назад

    Again excellent video an yes ive already checked out tinas channel ive subscribed as she gives a good tutorial on the gas stuff very good to watch as its a vood way to recap stuff

    • @HeatingGeek
      @HeatingGeek  5 лет назад

      She teaches for a living so should be good for new guys and recapping before ACS.

  • @dardobartoli
    @dardobartoli 4 года назад +1

    Thanks for this. I have kept my Biasi M90F going for over 17 years, and lost count of the times I have had to solder dry joints over the years.
    However, an intermittent fault, whereby the CH only comes on after running DHW might mean it's beyond economical repair.
    I do know that the Expansion vessel is leaking and loosing pressure slowly, but unsure whether this might manifest itself as that intermittent fault.

    • @HeatingGeek
      @HeatingGeek  4 года назад +1

      No, the vessel won't cause this intermittent issue. It could be the main PCB or an NTC issue.

    • @dardobartoli
      @dardobartoli 4 года назад

      @@HeatingGeek As the expansion vessel is definitely knackered, I'll get it replaced. As for the main board it appears not to have any poor solder joints (unlike the ignition sequence PCB) but may consider changing. Int the meantime I'll investigate the NTC and if all that fails, will replace the boiler. Thanks for advice.

    • @HeatingGeek
      @HeatingGeek  4 года назад +1

      @@dardobartoli Ok, Good luck with it. :-)

    • @dardobartoli
      @dardobartoli 4 года назад

      @@HeatingGeek Vessel replaced, along with new ignition pcb, then the main pcb, and both thermistors and have flushed the system, thorough clean of exhange unit... guess what, still the same issue. Only now everything works for longer and hotter (I think) before I get the dreaded fast flashing green light and no ignition.
      In short, everything works as expected and after an undefined period of CH and/or DHW the boiler goes off and the green light rapidly flashes. Then after an undefined period, run the DHW and all works again as expected.
      This M90e is like one of the family now, I don't want to replace it :-(

  • @fordford1557
    @fordford1557 Год назад

    My boilers got same problem if I change board do need to reset anything

  • @jamesbroadbentplumbingandh1648
    @jamesbroadbentplumbingandh1648 5 лет назад

    Great video. Look forward to the video on fans and pwm

    • @HeatingGeek
      @HeatingGeek  5 лет назад

      I need to do so many videos. soooooooooooooon ish.....

  • @Hitngan
    @Hitngan 5 лет назад +2

    Already subscribed to tina

    • @HeatingGeek
      @HeatingGeek  5 лет назад

      Good nothing like her channel to brush up with regs.

  • @robertvarga4534
    @robertvarga4534 3 года назад

    🙏👌🤔So, my green lights stopped working but still the radiator working&hot the green lights must be workng always or not neceserally?!
    2nd.i used radiator key(I bought ebay £1.60) just take out the Pressure time to time from the radiator, but I realised it I taken to much pressure out from them, so the radiators aren't getting warm.., so on the boiler I'm done something the pressure came back, but I wasn't sure how much pressure is good up to number 2 or 3 or 4 or less, I think mine one it was 2.5
    But after 2 days it was around 2 or the biasi boiler automticly selected itself the right pressure number?!
    TO BE HONEST AT THE SAME TIME I WAS HAPPY BECAUSE MY RADIATORS MUCH WARMER THEN BEFORE... 🙏👌🤔
    3rd if the green light doesn't work its a small sign do something or the boiler could work without the green light?!
    And sometimes it happened before this so when we used the radiator /hot water time to Time we realised it we don't have hot water or radiators are not hot, so we turned off the electric & turn back on and some reason when we turned back the electric the boiler was on again & we had hot water & radiator was hot again, what are connections between them?!
    Thanks your time.., have a good day..
    🤔

  • @wai-holi3861
    @wai-holi3861 11 месяцев назад

    Hi, my bathroom is hot but my bedroom is boiling hot radiator, so what should I do pls?

    • @HeatingGeek
      @HeatingGeek  4 месяца назад

      Sorry I didn’t respond to this comment. I didn’t see it in my feed. :-(

  • @gonzalomartinez1630
    @gonzalomartinez1630 5 лет назад

    Great Video, thanks for sharing.

    • @HeatingGeek
      @HeatingGeek  5 лет назад

      Thanks. for watching it. :-) I have a soft spot for Biasi.

  • @themadhatter4761
    @themadhatter4761 5 лет назад

    Thanks as usual, subbed Tina 👍👍👍👍👍

  • @sarziryn
    @sarziryn 3 года назад

    Same issue with my boiler, the exact same 1 in the video. The pcb was replaced 10 months ago... now the issue is back? 😭 had no heat overnight for a week almost now. As you say the issue is intermittent so during the day I can get it going but I cant stay up all night doing the same 🤦‍♀️

    • @HeatingGeek
      @HeatingGeek  3 года назад

      Could be the same issue. Very common.

  • @andrewjones3606
    @andrewjones3606 4 года назад

    Hey daniel my bro has a similar fault however it the 2nd light flashing red and the 3rd light flashing green. No heating no hotwater

  • @TheLeroyHenr
    @TheLeroyHenr Год назад

    How can I set a time for boiler to come on please and of.

    • @HeatingGeek
      @HeatingGeek  4 месяца назад

      Sorry I didn’t respond to this comment. I didn’t see it in my feed. :-(

  • @danielwilliams3162
    @danielwilliams3162 5 лет назад

    Hey heating geek, loving your videos, I think I've watched then all now. As a service and repair engineer myself, I'm just wondering if there's any other uploaders on RUclips that you rate please? Or could you suggest what the best training courses I could go on might be please?
    Thanks a lot...Dan :)

    • @HeatingGeek
      @HeatingGeek  5 лет назад +1

      I watch things like EEV blog and AEV. No Gas engineer stuff. I have enough of gas with work and Videos. :-) thanks for watching.

  • @tonygreenbank8611
    @tonygreenbank8611 3 года назад +1

    The timer on these boilers have to be the work of the Devil. Not one customer knows how to use it, and I struggle.

    • @HeatingGeek
      @HeatingGeek  3 года назад +1

      I don't know how to use it and I refuse to learn. No point. Absolutely rubbish

  • @Batmanski1
    @Batmanski1 2 года назад

    I got same boiler, radiators is hot during use hot water. This is diverter fault?

    • @HeatingGeek
      @HeatingGeek  2 года назад

      it could be. It also could be the plate heat exchanger being partially blocked.

  • @MSKChess
    @MSKChess 5 лет назад

    Tina is 2 awesome :D

  • @leaturk11
    @leaturk11 5 лет назад

    good job...will pop over to Tina channel and have a shuffty.

  • @Taqqiyastar
    @Taqqiyastar 5 лет назад

    Very good mate
    You have gone all the way to prove that it is the pcb
    Your friend channel
    I did watch.
    But yours more accurate and logical approach towards fault finding.
    Tina mentioned to do gas rate on a logic that first you have to run the appliance for ten minutes for the injector to expand to allow more gas to pass
    Which this is not the way i was trained.
    We know we must not poke injector with a needle because the hole may get big
    But my theory is if the injector expand the gas flow will increase through the injector
    You and i know where the injector is located inside ideal logic so how does heat expand the injector
    I am confused but you have more experience can you through some light on to tinas video
    My intention is not to put anyone down but i want understand in logical sense
    So why do we have to run the boiler for ten min before we do gas rate a combi boiler
    You know you put the boiler on maximum demand or engineers mode to do gas rate and then gas rate on heating
    So i don't get it on tinas video
    But shes doing good work

    • @HeatingGeek
      @HeatingGeek  5 лет назад +1

      The time thing is in IGEM document. Not very relevant to newer boilers but the burners do expand. Watch my Glowworm Ultimate video to see some of the things you ask about. :-)

    • @aj7303
      @aj7303 5 лет назад

      Who is Tina??????

  • @Mhuctchinson
    @Mhuctchinson 4 года назад +1

    and the boiler still has no pressure, not once has he mentioned water pressure, it should be around 1 bar and is on zero, and I bet it still has the same issue after he left and charged a fortune to some unsuspecting member of the public!!!!!!!

    • @HeatingGeek
      @HeatingGeek  4 года назад +3

      You have no idea.... Thanks for watching :-)

  • @mrmagoo6966
    @mrmagoo6966 3 года назад

    Easy in the end. lol

  • @jamesjulian
    @jamesjulian 5 лет назад

    It’s not against the law to repair a pcb but unless it been tested by pcb Manufacturer once you fit it you are asking for trouble, it’s the person who fit it is Liable if there’s a fire and if gas safe don’t prosecute you ,then customers insurance will take you to the cleaners!

    • @HeatingGeek
      @HeatingGeek  5 лет назад +1

      British gas fit refurbished PCBs and got Ideal Icos/Isar PCBs remade (which Ideal didnt like). Im not too worried.

    • @jamesjulian
      @jamesjulian 5 лет назад

      BG are a law to themselves, just letting people know , only takes one time. 👍🏻

    • @jamesjulian
      @jamesjulian 5 лет назад

      Have one of your pilot cleaning pin , use it all the time! 👌🏼

    • @HeatingGeek
      @HeatingGeek  5 лет назад +1

      @@jamesjulian BG make the rules with gas safe so I think we will see some changes come in sooner or later (Under the radar I'm sure). Maybe it's happened. Re soldering a resister is using the same OEM parts. I can see it causing a problem.
      Have you ever known someone go to court for it?

    • @jamesjulian
      @jamesjulian 5 лет назад

      25 years ago they ran the show, I know rules are written after there mistakes and as the biggest gas Employer there working practices are considered , its British standards, building regulations and manufactures instructions,. And in manufactures instructions it normally says genuine parts parts only to cover themselves and that’s where people become unstuck , the ask is yes I have known people to be in court. I feel like the geek 🤓now . Have a good day

  • @theworldofleia2955
    @theworldofleia2955 5 лет назад

    Biasi... no water & heating