Can You Spot My Mistake?? - A Day In The Life Of A Gas Engineer 146
HTML-код
- Опубликовано: 1 окт 2024
- Can you spot my mistake? Do you think I managed to find a way around it or bite the bullet?
Collab video with @thegasexpert-yt
Hope you enjoy the video!
As always, thank you all for supporting the channel, I appreciate it!
#plumbing #heating #boiler
velocityprogea...
unilite.co.uk/...
Use code UNCLE for 25% off
Powered Now - Job Management Software
www.powerednow...
towel radiator
vaillant
ufh
underfloor heating
blockage
magnetite
scale
lockshield
radiator valves
electric
boiler
electrical
wiring
Thank you for watching! If you enjoyed please don't forget to LIKE & SUBSCRIBE 🙏🏾
Can’t believe you stood on a ladder cutting the flue. You seriously didn’t need that set up. What’s wrong with a plume kit. I like your work but it’s odd what you’ve done
Thanks good video. Only question I have is regarding the roof flashings. Will the vertical flue need to be removed again to fit the flashing or are there different types of flashing can be used on flat roofs
We left a flat roof flashing piece there which is rubber so can be cut wrapped around and then resealed with some CT1 or similar 👍🏾
That is a wicked solution almost looks professional😂. Which can’t be said about the customer.❤ Top job Chirag.
😂 thanks man 👍🏾
We all make mistakes mate, but you owned it ❤❤
Thank you Dan! 🙏🏾
Nice vid mate could you not
Of gone elbow elbow and use a horizontal flue about the roof?
Thanks mate, yeah that could have been an option too 👌🏾
That flue looks awful inside the building is he having that on show to match his walled decking lol 🤣😂🤣
😂😂😂
As that's open fronted and effectively a car port, could you not have used a plume management kit or where the distances from openings stopping that?
Yeah could have potentially done that too but Shoaib had already planned it vertical so we went with that
I done the exact same thing with a vaillant flue. I used the rear flue outlet and cut it too short. Cost me another £130 for another flue🤷🏼♂️🤦🏼♂️
Ah mate, I'm guessing you cut the inner too then? I got lucky when I realised after just cutting the outer!
@@cputilitysolutions yeah i cut the flue flush with the bracket and on the rear flue your meant to leave 25mm longer to go into the boiler seal! Wont be making that mistake again🤦🏼♂️
Nnnnnooooo you have to show us how you make the sauce because the curry was fantastic 👍👍👍 come on uncle
Haha here you go mate - I use bits from both these to make it taste how I like 👌🏾
www.africanbites.com/jerk-marinade/
jessicainthekitchen.com/jamaica-jerk-sauce-homemade-and-easy/
Just curious wont gas safe say anything as the manual says "Vertical flue clearance , adjacent to a boundary line. = 300mm" does not look 300mm? but its hard to say in a video
I think it'll be ok mate 👍🏾
@@cputilitysolutions Thats good I only ask as domestic game is new to me. Please keep the videos coming as your attitude to this work is amazing and you definitely help the community with what you put out for us.
Interesting use of decking 😂
Must have had a lot left over from a job 😂
Can you drop the recipe please pal for the seasoning
www.africanbites.com/jerk-marinade/
jessicainthekitchen.com/jamaica-jerk-sauce-homemade-and-easy/
A couple I've tried mate 👍🏾
Great content as always, what mini angle grinder are you using please
Thanks - I've got the 18v DeWalt one but that was Shoaib's Milwaukee 12v one
@@cputilitysolutions thanks mate 👍
Another excellent video.
Thank you 🙏🏾