    If you made a mistake when calculating the tensile failure of A-B-G-D your Tr was supposed to be Tr=0.85*0.9*3655*470*10^-3. Please correct me if I am wrong

    • @mashudupatricia3501
      @mashudupatricia3501 Год назад

      I think he made a mistake,he was supposed to use the effective net area not the net area, the Tr= 1314 kN