Building Loading - Wind loading calculations to SANS 10160-3 for an industrial building - SD424

Поделиться
HTML-код
  • Опубликовано: 17 окт 2024

Комментарии • 23

  • @makgalemalatji3150
    @makgalemalatji3150 Месяц назад

    I got a distinction for my final year design project because I was able to find this video to do my wind loadings on a long span truss roof. Thank you very much

  • @tambwemangalafrixel9061
    @tambwemangalafrixel9061 Год назад +1

    Sir, why are we using the apex height (5.5m) for calculating side pressures and roof pressures both on the Windward and Leeward sides instead of the height at the eaves(4.m)

  • @supersaint6504
    @supersaint6504 3 года назад

    very sweet voice you had, good explanation, thanks for uploading.

  • @yehudawolovitz2777
    @yehudawolovitz2777 3 года назад

    These videos are gold. Thank you so much. Keep it up.

  • @dylandewilzen1864
    @dylandewilzen1864 3 года назад

    Morning, I would just like to find out if the same principle would apply in the calculation of the internal pressure coefficients if the door opening in the above example now extended the full length of zone E(wind dir 0) ( 3 sides closed and 1 side permanently open)? For the 0 wind direction, would the Cpi=0.9 x Cpe(zone e) and for the 180 wind direction (wind blowing into opening) be Cpi = 0.9 x Cpe(Zone D)?

  • @sandilesibiya812
    @sandilesibiya812 4 года назад

    Thank you the clearly explained example. I really appreciate it.

  • @lwandilembewana5587
    @lwandilembewana5587 9 месяцев назад

    Hi, for taller buildings as in case b and c in Figure 7, do you have to calculate the wind pressures using the heights specified there like the way you did for the eaves and apex wind pressures?

    • @richard_walls
      @richard_walls  9 месяцев назад

      That is correct. Zone D has multiple pressure zones with multiple z values for the pressures.

    • @lwandilembewana5587
      @lwandilembewana5587 9 месяцев назад

      @@richard_walls thank you very much

    • @masithembedumezweni3473
      @masithembedumezweni3473 4 месяца назад

      @@richard_walls Good day sir, I would like to know how do you approach wind loading for a Tuscan roof double storey office, with timber trusses

    • @richard_walls
      @richard_walls  4 месяца назад

      @@masithembedumezweni3473 have a look in the roof profiles provided in SANS 10160-3 and get the closest to your shape. Some interpolation may be required between layouts. The material used, eg timber, had no influence on the pressures, but rather the shape.

  • @nonjabulogumbi3296
    @nonjabulogumbi3296 4 года назад

    Thank you so much for the explanation, very clearly explained.

  • @rhyanwudraj9522
    @rhyanwudraj9522 Год назад

    Good Day. I have found your series of videos on wind loads very informative. The code itself can be a little confusing. Is it possible for you to share a copy of the question paper being worked through?

  • @nil0kal027
    @nil0kal027 3 года назад

    Very well explained. Thank you

  • @foxmk1782
    @foxmk1782 3 года назад

    May you please give us the name/terms of symbols on the roughness calculations

  • @saravanakumar2702
    @saravanakumar2702 3 года назад

    Thank you so much, May I know the ultimate safety factor for wind (ULS)

    • @richard_walls
      @richard_walls  3 года назад

      Hi. It's 1.6 in South Africa (used to be 1.3). Thanks

    • @saravanakumar2702
      @saravanakumar2702 3 года назад

      @@richard_walls Can i have the reference document link

    • @richard_walls
      @richard_walls  3 года назад

      @@saravanakumar2702 The document is SANS 10160-1 (loading) or SANS 10160-3 (wind). The codes can be purchased from the SABS.

  • @adeleoosthuizen2852
    @adeleoosthuizen2852 4 года назад

    Thank you so much. :-) Much appreciated

  • @qinisolunga4770
    @qinisolunga4770 2 года назад

    Thank you very much

  • @nonjabulogumbi3296
    @nonjabulogumbi3296 4 года назад

    May you kindly do the truss design loading

  • @georgen9755
    @georgen9755 Год назад

    Only purlins are visible from balcony