  • In this video, we'll guide you through quickly fixing the P4 error code on your Midea, Koppel, Kolin, Condura, Everest, BlueStar, Carrier, Lloyd, Dawlance, and Orient Mini Split AC. If you've encountered this error, don't worry! We'll provide step-by-step instructions and troubleshooting tips to resolve the issue efficiently. Our expert tips and techniques will help you identify the root cause of the P4 error code and implement the necessary fixes. We'll cover common issues that trigger this error and walk you through the troubleshooting process, ensuring you can get your Midea Mini Split Air conditioner up and running smoothly again. Whether you're a DIY enthusiast or a beginner, this video is designed to be easy to follow, providing clear explanations and visual demonstrations. By the end of this tutorial, you'll have the knowledge and confidence to resolve the P4 error code on your Midea Mini Split AC without any hassle. Don't let the P4 error code disrupt your comfort. Join us in this video and learn how to quickly fix it, saving time and money on professional repairs. Remember to subscribe to our channel for helpful tips and solutions for your Midea Mini Split AC. Let's get started on resolving the P4 error code together!
    ******************************************************************************
    Products You Might Be Interested to Buy
    Multimeters
    NEOTECK Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dml...
    ANENG Q1 Digital Multimeter ➡️ s.click.aliexpress.com/e/_DeU...
    Digital Pen Multimeter ➡️s.click.aliexpress.com/e/_DkM...
    Rechargeable Smart Multimeter ➡️s.click.aliexpress.com/e/_DDm...
    UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexpress.com/e/_DFL...
    ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dln...
    TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexpress.com/e/_DB8...
    MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexpress.com/e/_Ded...
    ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dd9...
    ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexpress.com/e/_DEz...
    Thermal Camera
    UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexpress.com/e/_Deo...
    TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexpress.com/e/_Dm0...
    Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexpress.com/e/_Dej...
    Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexpress.com/e/_DCO...
    Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexpress.com/e/_DCe...
    TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexpress.com/e/_DmB...
    Soldering Wires
    10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexpress.com/e/_Dkg...
    0.8mm/1.0mm 50g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDn...
    0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDC...
    200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexpress.com/e/_DdQ...
    8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexpress.com/e/_DCm...
    Vacuum Pump
    18V Lithium Battery Vacuum Pump ➡️ s.click.aliexpress.com/e/_DDK...
    VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkT...
    Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkH...
    VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexpress.com/e/_DeA...
    Mani Fold Gauge
    Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexpress.com/e/_DC3...
    Refrigerant pressure gauge ➡️ s.click.aliexpress.com/e/_Ddg...
    500/800PSI Refrigerant Manometer ➡️ s.click.aliexpress.com/e/_Dne...
    Air Condition Gauge Manifold ➡️ s.click.aliexpress.com/e/_DFu...
    Soldering stations
    RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexpress.com/e/_DBa...
    GVDA New Soldering Station ➡️s.click.aliexpress.com/e/_DDc...
    JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexpress.com/e/_DBX...
    SUGON T21 Soldering Station ➡️ s.click.aliexpress.com/e/_Dne...
    AIFEN A5 Pro Soldering Station ➡️ s.click.aliexpress.com/e/_Dns...
    UYUE T210 Soldering Station LED Digital➡️ s.click.aliexpress.com/e/_DeI...
    Soldering Stations MECHANIC➡️ s.click.aliexpress.com/e/_DmW...
    Desoldering pumps
    Desoldering Pump Suction Tin Gun ➡️ s.click.aliexpress.com/e/_De1...
    110V/220V Electric Tin Suction Sucker Pen ➡️ s.click.aliexpress.com/e/_Ddu...
    Gaqqee 220v 36w Electric Solder ➡️ s.click.aliexpress.com/e/_Dkg...
    ******************************************************************************
    💡 Support Us On Patreon 👉 bit.ly/3vMga6S
    💡Subscribe to The Channel 👉 bit.ly/3vNT7s3
    Social Links
    💡Facebook 👉 / forevertech3
    💡Instagram 👉 / forever_tech1
    💡Twitter 👉 / forevertech3
    #ac #p4 #error #code #airconditioner #split #minisplit #fix

Комментарии • 30

  • @manosdleros
    @manosdleros Год назад +3

    Thanks from Greece! Bro!

    • @forevertechenglish
      @forevertechenglish  Год назад

      Happy to help!

    • @user-rj5fy8yz1n
      @user-rj5fy8yz1n Год назад

      Πως το διόρθωσες φίλε μου;;

    • @manosdleros
      @manosdleros Год назад

      Θέλει μετρήσεις... Δεν είναι μόνο ένα στοιχείο... Τελικά ipm είχε πρόβλημα... Όλα τα κάνει η διάβρωση..

  • @wasimedoo7994
    @wasimedoo7994 Год назад +4

    Very good and important information 👍

  • @PlayerSlotAvailable
    @PlayerSlotAvailable Месяц назад +2

    First hit the breaker to fully cut electricity to both inside and outside unit for a minute, then turn it on again. It might be fixed that easilly. My P4 error was fixed like that.

    • @forevertechenglish
      @forevertechenglish  Месяц назад

      Well that's possible Because, if the voltages get low in the unit still the p4 error can be displayed. This could be the problem with your unit, the eeprom data got reset after you once turned it off and then turn it on.

  • @user-ib2tn6lr2s
    @user-ib2tn6lr2s Год назад +1

    I hope to attend you thankfully explain
    All Refrigerator Capillary Size and sinty miter

  • @Abdulquariosimea-el1rr
    @Abdulquariosimea-el1rr Год назад +1

    1)How can I calculate refrigerator compressor size and condenser to be use?
    2) can I use danfoss compressor to LG fridge or any compressor model to any fridge once the HP is correct?
    3) how can I calculate the evaporator to be use in fridge

  • @jessicavanness2934
    @jessicavanness2934 Месяц назад +1

    Should we have the motherboard replaced if we get a p4 error code on our mini split?

  • @wasimmulla6575
    @wasimmulla6575 Год назад +1

    🎉👌👍

  • @user-ib2tn6lr2s
    @user-ib2tn6lr2s Год назад +1

    All Refrigerator Capillary Size and long sinty miter

  • @teltras68
    @teltras68 11 месяцев назад +2

    I have done some testing with my LG unit because the compressor does not run, it wanted to run for 1 second and quits and makes a weird noise and stops.
    After some attempts it shows error 6 blinks on the indoor and outdoor unit.
    The info I found about this error is DC peak error, I dont know if it is correct or not.
    My LG inverter machine model is S09AW. Neo Plasma
    I did check IPM and tested ok on the high side disconnected from the outlet.
    But when is connected it only gets 9,5v on U,V,W. On your video it shows 15v maybe my ipm is not good or could it be someting wrong on the low side on the ipm?
    Ipm on high side has 315v dc
    I did tested resistance test on the compressor and it gives me 0.9ohm on all 3 points U,V,W and no shorts with case or pipes.
    Can you help me? My machine is mounted on the wall its not easy to test it connected to 230v.
    I hope you can point me into right direction. I've watched a ton of your videos and they are great.
    I cannot find any service manual for my machine maybe because its old...
    I did a video of the compressor attempting to start check my last video or use this link
    ruclips.net/user/shortsVKwRfHildsg?feature=share
    Thank you very much
    Regards from Portugal

    • @forevertechenglish
      @forevertechenglish  11 месяцев назад +1

      the Ipm voltage are good from 11 to 15 volts. Yes service manuals are hard to get. You can search for them online in pdf form. Can you send me the video of the blinks in your ac, maybe I could help you, send them on instagram or facebook. Thank you.

    • @teltras68
      @teltras68 11 месяцев назад

      The problem is I dont have instagram/facebook.
      My indooor blinks 6 times and the outdoor also flash 6 times this machine only has one red led on the outdoor pcb.
      I did post a video on my youtube channel on the last answer.
      As I said earlier the IPM has 315v on high side but does not output 15v to U-V-W pins, they only get 9 or 9.5v
      On the video I uploaded to youtube you can ear the motor about to start but maybe because it only gets 9vdv it quits to start. The machine try to start the motor several times before throwing the error.
      Thanks

    • @teltras68
      @teltras68 11 месяцев назад

      @forevertechenglish
      Update
      On low side of the ipm i have 14.7v and 5v.
      On the high side of the ipm i dont have 14.7v i only have 9.5v why?

  • @FSHerrante
    @FSHerrante Год назад

    Literally E1 is game over.

    • @forevertechenglish
      @forevertechenglish  Год назад

      is it midea ac?

    • @FSHerrante
      @FSHerrante Год назад

      ​@@forevertechenglish Yep, half motherboard is dead. The external unit only start in bridged mode. The technical service says that IPM is fried and there is no replacement and new MB is on 320€.

  • @Dan-mr5cl
    @Dan-mr5cl 11 месяцев назад

    I have a weird humming noise

  • @user-ib2tn6lr2s
    @user-ib2tn6lr2s Год назад +1

    I hope there will be a translation in Arabic

  • @jollyscaria1922
    @jollyscaria1922 22 дня назад

    Invertar err thmostlow volt not ac dc checking pcb checking main cmprssor checking high amper no checking and cnforomed gas gas high no checking snd indooe blower filter checking lecking no checking trricing find out fus pcb al ok

  • @user-zz5xl3lg6y
    @user-zz5xl3lg6y 5 месяцев назад

    Why the P4 error show we're is the problem but before the same problem thats why we change the board

    • @forevertechenglish
      @forevertechenglish  5 месяцев назад

      I have already told about this p4 error problem in the video. Its Compressor drive error

    • @forevertechenglish
      @forevertechenglish  5 месяцев назад

      You mean to say that your air conditioner was showing a p4 error code, you replaced the board with new, can i know which board you replaced the indoor or the outdoor? After replacing the board it still show p4 error that what you mean to say.

    • @user-zz5xl3lg6y
      @user-zz5xl3lg6y 5 месяцев назад

      The same specs then other error code show P4 so why iam telling you we're is the cause of that error again