My question is about the actuator plug. Why when you check the voltage with connected on actuator you get 24V dc??? But if you put back on actuator there are no voltage
Good morning from nigerian i need a technical support i want to connect 5 sigma xt fire suppression panel together does it have the feature and what terminal that accept the connection
Thanks for your good information but I have some confusion about this panel,details given below. 1. Key Suppression disconnect switch , where I connect this switch in panel and how? 2. 1st & 2nd stages what about this, normally we need to loop with NAC 1,2,3? 3. How I can interface with fire alarm system for trouble & fire. Please give me solutions.
Thanks for your comments Check the below mentioned Ans 1. If you are use separate disconnect switch. Just connect in the panel Extrac options to disconnect switch and from disconnect to Ivo or aerosol generators. If you want to Use in the panel auto and Manuel key for the disconnect switch , you can use. Just bring the cable from ivo or aerosol connect back side of the auto and Manuel key then from auto & Manuel key to connect in Extract Com. & NO. 2. 1 stage & 2nd stage you need to use for sequence operation. NAC 1,2 to 1&2stage and Horn strobe bell need some wiring. 3. Trouble, First alarm & Release you can connect direct in the panel. For 2nd alarm you need to make waring. You have to provide 24vdc relay.
I recognize that some panel termination of the low presdure switch has a resisor with cable and some does not have. Is there any clarification for that? Or it depend in the type of panel?
Assalamuaikum..... Sir, I have a panel like that but it always makes a sound bib bib bib... then the indicator shows a yellow light on comms fault... can you please help sir what's the problem...? please sir I hope for your answer... Thank you Sir Barakallah fii umrik
I have been installing the sigma A-XT suppression FACP, but when I tried to enter level 3 programming the control panel continuously beeps and general fault led lits, even if I pressed the mode button I could not able to program it. please give me a suggestion on what shall I do?
Did you check the time delay programming number???? Just press the Lamp button and check the (-) options then set the time delay -30 second.If it’s not work plz send to me your programming number then I can rectify. Why it’s not working. Thanks for your comment
Sir can you help me. I have same control panel you have fm200 supression i have problem in the nac i already terminated the bell on nac1 and i have also have detectors in zone1 and zone2 but when i try to activate the detectors its shows on panel only zone trouble, and also the the bell was not activated can you help me about the termination about this thanks in advance
In nac options you have to use 10k Resistance then trouble will go... Bell negative wire connect in nac and nac to 1 stage com loop 1wire and in No connect bell positive wire...
Sir relay contact 24v and bms ,scader and diesel cut off control how to connect pls relay number 24v + coil 14 and 13 and -use as common plse explain relay number
If you want 1st signal it should be Cut so you have to connect one wire in relay com and No. Coil 13 connect auxiliary + wire coil 14 connect 1 st alarm options No wire. And Auxiliary - one wire connect in 1st alarm common options
Of course! Before install aerosol generator u have to make sure temperature of aerosol generator. And distance from materials to generator . Bcz aerosol generator is more sensitive, check the type of generator & temperature. Then check the Proper excess from Aerosol generator to materials.
I am Shabab Alam I need wairing Diagram with All fire system Equipment ex. Smoke detector mcp sounder hell horn etc all 24vdc relay only Fire suppersion system FM200
আসসালামু আলাইকুম, কেমন আছেন ভাই, ভিডিও দেখে ভালো লাগছে আরো উপকৃত হব যদি বাংলা করে আপলোড করে।
Could you please describe particularly interfacing with the BMS system, it's very important bcz most of the technicians don't know about it
You are very good at this i wish i have your skill
Thanks
Thanks
Good sir thanks for your explanation
Nice training i appreciated you, how i can connect high pressure and low pressure switch it is not clear to me please
AsSalam u Alikum i am from Pakistan
can u help me
W/s. I'm from Bangladesh
How much ohm resistor attached for manual release pull station with
positive
Sir, good job
My question is about the actuator plug. Why when you check the voltage with connected on actuator you get 24V dc??? But if you put back on actuator there are no voltage
Good job sri ...thanx..
Thanks
Good morning from nigerian i need a technical support i want to connect 5 sigma xt fire suppression panel together does it have the feature and what terminal that accept the connection
Thanks for your good information but I have some confusion about this panel,details given below.
1. Key Suppression disconnect switch , where I connect this switch in panel and how?
2. 1st & 2nd stages what about this, normally we need to loop with NAC 1,2,3?
3. How I can interface with fire alarm system for trouble & fire.
Please give me solutions.
Thanks for your comments
Check the below mentioned Ans
1. If you are use separate disconnect switch. Just connect in the panel Extrac options to disconnect switch and from disconnect to Ivo or aerosol generators.
If you want to Use in the panel auto and Manuel key for the disconnect switch , you can use. Just bring the cable from ivo or aerosol connect back side of the auto and Manuel key then from auto & Manuel key to connect in Extract Com. & NO.
2. 1 stage & 2nd stage you need to use for sequence operation. NAC 1,2 to 1&2stage and Horn strobe bell need some wiring.
3. Trouble, First alarm & Release you can connect direct in the panel. For 2nd alarm you need to make waring. You have to provide 24vdc relay.
Super bro great job thanku
Thanks
Asalamalekum
Nice training
You video help me
Thanks
Asalamalekum
How are you. Sir
W/C fine and you?
Regarding low pressure switch, after dischsrge, is the panel still indicating trouble ? Or it will stop lighting in the board of the panel?
After discharge continue panel showing indicate low pressure trouble..
I recognize that some panel termination of the low presdure switch has a resisor with cable and some does not have. Is there any clarification for that? Or it depend in the type of panel?
It depend inthe type of panel
But resistance should be connect in the Low pressure EOL.not in the panel
Assalamuaikum.....
Sir, I have a panel like that but it always makes a sound bib bib bib... then the indicator shows a yellow light on comms fault... can you please help sir what's the problem...? please sir I hope for your answer... Thank you Sir
Barakallah fii umrik
Nice
Thanks
good work
tnx broo
Thanks
Good job..
Bhai Novec system 1230 faulty trouble moniter how to Remove
good day sir.can you please make video on how to connect access door to a conventional fire alarm control panel .thank you sir in advance.
I have been installing the sigma A-XT suppression FACP, but when I tried to enter level 3 programming the control panel continuously beeps and general fault led lits, even if I pressed the mode button I could not able to program it. please give me a suggestion on what shall I do?
ruclips.net/video/c0AGAJupBLA/видео.html
Good day men I got a small problem to set up my fire Panel
What happen
I did not really understand how to contact from the cylinder to the mother board sir
❤❤❤❤
Asalamalekum sir
WC
Thanks khudahafij
Thanks
disable switch is on falt release trouble is off after no falt problem you solved
How to solve power troubles problems?
Panel buzzer is not working how can i disable the beep beep sound
How to remove that releasing trouble
manual only ..means manual release at smoke it will not work.. only mechanical release from cylinder will work
Good job bro
Thanks bro
Thanks
Hindi me bhi vedio banaya karo yar
hello brother on zone activation abort switch is not working and it not hold the count down timer is there any programming for abort switch
Did you check the time delay programming number????
Just press the Lamp button and check the (-) options then set the time delay -30 second.If it’s not work plz send to me your programming number then I can rectify. Why it’s not working. Thanks for your comment
ruclips.net/video/c0AGAJupBLA/видео.html
Plz check this video
@@foyzulislam9975 yes its -30 time delay only
@@foyzulislam9975 i already checked this video also but same issue while push and hold abort switch count down are still not stop
can i get your contact no
Good job
Sir can you help me. I have same control panel you have fm200 supression i have problem in the nac i already terminated the bell on nac1 and i have also have detectors in zone1 and zone2 but when i try to activate the detectors its shows on panel only zone trouble, and also the the bell was not activated can you help me about the termination about this thanks in advance
Connect in 1 stage. You need to wiring some cable nac to 1 stage then it will be work
@@foyzulislam9975 i will try sir i hope it will work thanks
O tried sir but when i put the positive in nac 1 and the negative in stage 1 the panel show fault in nac 1
In nac options you have to use 10k Resistance then trouble will go... Bell negative wire connect in nac and nac to 1 stage com loop 1wire and in No connect bell positive wire...
How can I get you ? for assistance
You From????
Sir relay contact 24v and bms ,scader and diesel cut off control how to connect pls relay number 24v + coil 14 and 13 and -use as common plse explain relay number
Which signal u need to diesel cut off control????
If you want 1st signal it should be Cut so you have to connect one wire in relay com and No. Coil 13 connect auxiliary + wire coil 14 connect 1 st alarm options No wire. And Auxiliary - one wire connect in 1st alarm common options
How to remove and refile novec1230
I have a question am one site there are using the aerosol system any heads ups
Can you connect the do not enter direct in the panel without relay
Of course! Before install aerosol generator u have to make sure temperature of aerosol generator. And distance from materials to generator . Bcz aerosol generator is more sensitive, check the type of generator & temperature. Then check the Proper excess from Aerosol generator to materials.
No, for do not enter we need to provide additional 24 v relay
@@foyzulislam9975 okay thanks tomorrow I be doing the termination for the panel I come around for more knowledge thanks
ruclips.net/video/pW0X85q7Rzg/видео.html
Click here for details of aerosol generator
How to remove Releasing trouble?
Check the diode connection (+&-).
Please sir FM 200 panel wiring connection in bangla please please please
Pfc potter panel programming method
Coming Soon
I am working
Fm 200 fike compuny panal
Sold
Good job
I am afroz ahmad please sir give me wairing diagram all part and all relay wairing diagram thank you
ok
I am Shabab Alam I need wairing Diagram with All fire system Equipment ex. Smoke detector mcp sounder hell horn etc all 24vdc relay only Fire suppersion system FM200
Great training
Tnx
Where will be BMS tarminetion??
BMS should be connecte to its relay
Have option for DO NOT ENTER USING PANEL ONLY
No
Are you Bangladesh
???
Hello can you send mi wiring diagrame of this panelle .vidéo at .7.56 minutes pleas sir
let see
Sir please give me the Answer of Question
I will also need your email address i need technical support i like your work