How to Charge Refrigerant (Gas) in an AC unit?

Поделиться
HTML-код
  • Опубликовано: 24 ноя 2024

Комментарии • 100

  • @zameenwala754
    @zameenwala754 10 месяцев назад +10

    You tell everything about gas charging step by step . Now No question is remain .
    Full guide 👍💡

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  10 месяцев назад +2

      I am glad. But there are many things about refrigerant charging. I will explain everything in a video.

    • @zameenwala754
      @zameenwala754 10 месяцев назад +2

      @@zebralearningsenglish-pn6fl oka sir I will be wait 😊

    • @jollyscaria1922
      @jollyscaria1922 9 месяцев назад

      Suchionline contened dis ..chergd lind contactinv yelow chwfgjnv cylinder valvropon cylindef R420 cylimdef up fosn anc cherhrinv ues fighte allthsnkyou gues wdlcome purgdaftef yes testing fixing checkinv znd oneby meghec ok

    • @ravijeeverma876
      @ravijeeverma876 4 месяца назад

      ​@@zebralearningsenglish-pn6flcan I get ur number

  • @Balticblue93
    @Balticblue93 Год назад +38

    410A needs to have the bottle inverted upside down to charge properly as a liquid. If you charge it upright, it will fractionate the near-azeotropic mixture. R22 is a single component and can be charged as a gas.

    • @gabrielphilips6980
      @gabrielphilips6980 Год назад +1

      What is 410a? What is r22?

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  Год назад +4

      It's depends on the cylinder. Before charging the refrigerant we should check the instruction on the cylinder how to charge.

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  Год назад +9

      R410A and R22 is two different types of refrigerant (Gas).
      R22 is older type refrigerant and R410A is modern refrigerant.
      R410A is more environmental friendly than the R22 refrigerant.
      Because R22 has chlorine atoms which dangerous to ozone layer but R410A doesn't have any chlorine atoms.
      The modern AC systems are replacing the R22 refrigerant with R410A refrigerant.
      R22 Refrigerant will not be available in the future due to environmental concerns.

    • @DaveMavrik-ki7xb
      @DaveMavrik-ki7xb 8 месяцев назад +1

      Does r22 and r32 also need to turn the cylinder upside down too?

    • @Balticblue93
      @Balticblue93 8 месяцев назад +1

      @@DaveMavrik-ki7xb R22 and R32 are single refrigerant and their composition does not change. Thus both liquid charging and gas charging is possible. Liquid charging of R32 all at once from the low - pressure side may cause the compressor to malfunction.
      Working pressures for R32 are very similar to R410A and when charging, R32 is easier to handle as it can be charged in both a gas and a liquid state. This why R32 is classified as A2L “mildly flammable” while safety data sheets say it is extremely flammable but it really is very low flammability.

  • @anookgujjala4132
    @anookgujjala4132 9 месяцев назад +3

    Nice explanation sir 👍thank you

  • @elnursafaraliyev6618
    @elnursafaraliyev6618 5 месяцев назад +6

    Hi. Why need to connect high pressure line if we are not use that during charge refrigerant?

  • @pranavprasannan0039
    @pranavprasannan0039 3 месяца назад +2

    The low-pressure line is typically used for charging refrigerant gas, whereas the high-pressure line is used for charging refrigerant liquid. Liquid charging generally takes less time compared to gas charging.

  • @НуроЗаринХан
    @НуроЗаринХан 5 месяцев назад +2

    Thank you for this good animation! 👍🏼

  • @4cchansemicircle944
    @4cchansemicircle944 10 месяцев назад +2

    ​​This is a very good video. Please my question is I added refrigerant to my 1hp Samsung spit AC when the power was turned off and I waited 10 hours to put the power on. Is it okay?

  • @babaolowo35
    @babaolowo35 Год назад +2

    THANK you

  • @ewomazinoabugo5829
    @ewomazinoabugo5829 4 месяца назад +1

    Please i want to know using my single guage, on the PSI scale, what number should be the jogjest I'll let the gas reach in a 1.5hp inverter AC

  • @HarunTechnology
    @HarunTechnology 8 месяцев назад +1

    Nice video

  • @sahamghaffarinader6149
    @sahamghaffarinader6149 4 месяца назад

    Thanks a lot very usefull ❤

  • @phyowin5288
    @phyowin5288 7 месяцев назад +1

    very clear video🎉🎉

  • @otrovx
    @otrovx 7 месяцев назад +1

    Hi, thanks for the video. Is it necessary to attach the red hose to the air conditioner in order to fill it? I have simpler manifold gauge, with only blue and yellow hose (without red hose, and without red gauge).

  • @densista1160
    @densista1160 8 месяцев назад +1

    can you fill using the red hose to the low pressure side?

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  8 месяцев назад +2

      No you can't fill through the red hose. Because the red hose in connected the high pressure side. If you try to charge through the red hose. Instead of the refrigerant going into the unit, the refrigerant will return to cylinder from the unit because of the pressure difference.

  • @slobodanmilic1331
    @slobodanmilic1331 4 месяца назад

    Pls produce video about electrical connections.

  • @7starernhernh580
    @7starernhernh580 5 месяцев назад

    Very good sir ji....exvelenttt

  • @7starernhernh580
    @7starernhernh580 5 месяцев назад

    I m instrctor r/ac..but your mathed very Excelent.......

  • @QuangLe-eg5si
    @QuangLe-eg5si 8 месяцев назад +1

    Could you explain to me what happens if we open high-pressure on-off valve when we charge refrigerant ( GAS ) in an AC UNIT ?

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  8 месяцев назад +3

      If we open the High Pressure On/Off Valve, Refrigerant will start going from AC Unit to Refrigerant Cylinder. Because the pressure in the High Pressure Side of the AC Unit is more than the pressure in the Refrigerant Cylinder.

  • @sabudjed1135
    @sabudjed1135 3 месяца назад

    Very good

  • @TheGines1979
    @TheGines1979 8 месяцев назад +1

    Can you show other techniques? Please

  • @densista1160
    @densista1160 8 месяцев назад +1

    one question, is the red hose to high pressure line, complete shut off all the process?

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  8 месяцев назад

      Yes, it will be completely shutoff through out the process.

    • @densista1160
      @densista1160 8 месяцев назад

      why have it connected then? can't you just have the blue hose connected to fill ?@@zebralearningsenglish-pn6fl

  • @HeraTaboro
    @HeraTaboro 4 месяца назад

    Please i need more information about Refrigeration and ac

  • @ganeshgarai416
    @ganeshgarai416 5 месяцев назад +4

    What is the need of connect high pressure guage????

    • @NasimKhan-m3q
      @NasimKhan-m3q 2 месяца назад

      To know High pressure

    • @LuigGz
      @LuigGz Месяц назад

      To get readings of sub cooling

  • @HunterRavin
    @HunterRavin 11 месяцев назад +1

    How to know when its time to close the blue vlv after letting air out

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  11 месяцев назад +1

      Nice question. You can see that easily when the refrigerant comes out. It will come out like spraying water.

  • @tbone6354
    @tbone6354 8 месяцев назад +1

    A very helpful tip is to add 50ml of purified water to the compressor before regassing. This reduces corrosion and no need to vacuum

  • @patakotisrinivas1918
    @patakotisrinivas1918 10 месяцев назад +1

    Nice

  • @JerryDPaye
    @JerryDPaye 3 месяца назад

    How to use claim meter to recharge

  • @82levy5
    @82levy5 4 месяца назад

    How i know that i charged enough gas? What is the right pressure i looking for?

  • @lukebarron308
    @lukebarron308 5 месяцев назад

    Don’t you usually charge with the jug inverted ? Liquid not vapour

  • @jacobprem26
    @jacobprem26 6 месяцев назад

    How much time will it take to transfer gas from cylinder to ac outdoor unit

  • @mohammedegyptian2527
    @mohammedegyptian2527 7 месяцев назад +1

    bravo

  • @samisiddique5000
    @samisiddique5000 5 месяцев назад

    please tell us before charging gas required vacuum full machine required time and -psi value

  • @8m405
    @8m405 5 месяцев назад

    Why discharge valve on guage was closed thought-out

  • @babis8566
    @babis8566 Месяц назад

    This is not discharge line,it is liquid line.Its after the condenser and before the expansion valve.

  • @CATechTips
    @CATechTips 3 месяца назад

    How much refrigerant should charge

  • @abgzulkifli
    @abgzulkifli 6 месяцев назад +1

    How do we know how much gas need to be refill

  • @naeemtahir3406
    @naeemtahir3406 6 месяцев назад

    I was charging 410a while charging compressor and fan shut down itself, I checked breaker and thermostat both were on , what could have gone wrong

  • @InspiringlyPositive12
    @InspiringlyPositive12 Год назад +1

    👍👍👍

  • @tilvalhalla9343
    @tilvalhalla9343 5 месяцев назад

    Why does nobody ever show you what you do if you have a recovery cylinder I don’t know whether to hook it through the red or the blue

  • @Afhvac
    @Afhvac Месяц назад

    And unit offff what is prociger

  • @SanayaKhan-x9t
    @SanayaKhan-x9t Год назад

    Brother it's totally half knowledge about gas charging it's not the way we have to first leakage check and fill leakage than vaccum after all process gas charging 😊😊

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  Год назад +1

      It's just a basic concept of gas charging method. I'll make a detailed process of gas charging video and will upload it.

  • @nagatejachandaka13
    @nagatejachandaka13 4 месяца назад +1

    My name is teja

  • @davewindt1506
    @davewindt1506 9 месяцев назад

    Should shut down the unit en perform a vacuum test 24 hours prior charging the system to be sure the system is leak free and all the air is out.

  • @pradeepkumar-bd1wc
    @pradeepkumar-bd1wc 11 месяцев назад +1

    Gas charging ka Hindi me animation

  • @muhammadalifblogs
    @muhammadalifblogs 8 месяцев назад +1

    রিদয় নাড়া দেওয়ার মতো একটি নাটক।

  • @mohammedmuneer2390
    @mohammedmuneer2390 7 месяцев назад +1

    In hindi translation plz

  • @JerryDPaye
    @JerryDPaye 3 месяца назад

    Hi

  • @mansurshah9015
    @mansurshah9015 5 месяцев назад +1

    THis is for Brampton boys not the proper way thanks but no thanks

  • @NestorLaureano
    @NestorLaureano 3 месяца назад

    WRONG NEED SCALE,AFTER VACUUMING R410 OR R32 IN LIQUID STATE BEFORE RUNNING THE SYSTEM WITH EXACT WEIGHT.NOT OLD SYSTEM YOU ARE TUTORING.

  • @petergombos3012
    @petergombos3012 3 месяца назад +1

    No vacuum pump, no scales, not even a drop of environmental protection. We do not flush with refrigerant!!! The other is that it is not possible to connect to the discharge line. Sorry, but this is how don't do that.

  • @ACTECHNICIANBR09
    @ACTECHNICIANBR09 Год назад +1

    Hindi video

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  Год назад +1

      main hindi video bana raha hoon aur jald hee upload karoonga.

    • @ujjawalkamboj2965
      @ujjawalkamboj2965 Год назад +1

      Please continue in english

    • @zebralearningsenglish-pn6fl
      @zebralearningsenglish-pn6fl  Год назад

      @@ujjawalkamboj2965 Yeah sure, in this channel I will upload only English video. I have opened a separate channel for Hindi. In that channel I will start to upload videos in Hindi.

  • @mechanicalengineeringpract140
    @mechanicalengineeringpract140 7 дней назад

    Very good