Steps to Vacuum and Charge Refrigerant on a Mini Split Unit!

Поделиться
HTML-код
  • Опубликовано: 24 ноя 2024

Комментарии • 608

  • @acservicetechchannel
    @acservicetechchannel  5 лет назад +17

    Mini Split Book on Our Website- www.acservicetech.com/mini-split-book
    Mini Split Book on Amazon- amzn.to/3ytHJSs
    Mini Split Book on TruTech Tools- www.trutechtools.com/BooksGuides
    Mini Split E-Book on Google- play.google.com/store/books/details?id=HN-iEAAAQBAJ
    Mini Split E-Book on Apple- books.apple.com/us/book/id6445178399

    • @garyyancoskie905
      @garyyancoskie905 4 года назад

      Where did you purchase the 5/16" female quick connect x 1/4" female SAE adapter for the pressure gauge. Can only find female x male adapters . Thanks

    • @tommyt4062
      @tommyt4062 4 года назад

      hiya, could you tell me the pipe run length (i'm guessing short?) and obviously its difficult to see from a video but is that 1/2 and 1/4 pipe?
      Thanks

    • @goldbangle6184
      @goldbangle6184 4 года назад

      thank you so much because you now i can service ac 😍🌹🌹🌹🌹🌹🌹

    • @masoud_gh
      @masoud_gh 3 года назад

      شششششششش

    • @RajeshKumar-zf5je
      @RajeshKumar-zf5je 2 года назад

      PPP pppppppppppppp pp p0pppppppppppppppp0ppppppp of pp ppppp

  • @marklennon1580
    @marklennon1580 4 года назад +11

    I have seen many videos on how to do this procedure but none of them even come close to the clarity and precision that A/c service tech brings to the table.
    Thank you sir for helping the general save money and the atmosphere at the same time.

  • @electricboogie709
    @electricboogie709 5 лет назад +58

    I can't say enough about how I appreciate these. I have been doing HVAC/R for eight years now and I always go back and read, watch, learn, over and over again. Never being satisfied in myself, but making sure I do things always to the best I can. Plus my memory really sucks. Thank you!

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +6

      Hey you will be great with all the investing you are doing in yourself!

    • @daveyboy8907
      @daveyboy8907 Год назад

      Same here but at least we care enough to try our best..So many half ass techs out there just trying to bang them out and get done fast..

  • @youarehere1716
    @youarehere1716 3 года назад +31

    I'm a DIYer homeowner, not a tech. But for some reason I find heat pump technology fascinating even though at my age as an SW engineer, becoming a professional HVAC technician is not in the cards. After my 2nd multi-zone mini-split install where your videos provided most of what I needed to know, I finally bought your eBook. Your videos and free online docs helped me so much that I decided to get your eBook (to learn about checking and recharging a unit), and to understand things better. Also, you've earned the respect and appreciation to get some remuneration for your service, IMO. After getting about 10 pages in where you introduce the basics of refrigeration and the physics, I'm beyond impressed. The diagrams are excellent. The explanations, are clear, thorough, and convey the points succinctly.
    For anyone reading this, I'm in no way affiliated with these people, I'm just saying if you actually want to understand the core concepts and/or specifics, the book is a worthwhile investment. The eBook is pretty reasonably priced considering how good an educator the author is.

    • @floridasaltlife
      @floridasaltlife Год назад +2

      Same here, in fact it drove me to get my 608 and it has become a hobby...

    • @krehbein
      @krehbein Год назад

      Glad to hear other diyr’s can take this up as a fairly technical “hobby”. Not a sw engineer but web developer. Could you work on a traditional outdoor condenser unit, or the indoor evarporator?

    • @thomasjust2663
      @thomasjust2663 Год назад

      Its good for doing stuff on your home I guess, but not to work as a tech, then you have to deal with using ladders, aggressive dogs, lady's who are never satisficed with the work, customers that hit on you (both women and men), it can create all sorts of drama, is it worth it to spends hundreds of dollars for work you do perhaps twice a year? I'm not sure it is a cost saver, also you have to separate space to keep these tools in working order

    • @Mike-01234
      @Mike-01234 4 месяца назад +2

      I also do lot of DIY mostly automotive AC. In the last 3 years HVAC contractors have tripled their pricing, and many are just sales people trying to sell you new unit or a service plan. Now I do my own annual maintenance on my 4 ton packaged heat pump on my roof. I even ran a pex line off my evap cooler to connect a hose so I could wash the condenser every 6 months or after dust storms. I stock parts for my unit and my mothers AC split system caps, condenser fan motors, contactor. Local HVAC suppliers here refuse to sell to the public just buy online. The $1000 in stocking my parts, and HVAC tools is a tiny amount what one service call now costs from a local HVAC tech. My mother had a compressor run cap replaced HVAC tech charged her $680 that was during the week day not even at night or weekend. If they come after hours cap cost $1000 to replace it. New packaged unit install cost $12-15k now for a single stage goodman. Not even talking about duct work just $400 crane lift and use the same stand and elbow.

  • @blackishpariah
    @blackishpariah 5 лет назад +83

    I installed a Fujitsu last week, pulled down to and held 101 microns using your methods. You're my go to instructor.

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +5

      Awesome Kenneth, great job!! Thanks for letting me know!

    • @lordjaashin
      @lordjaashin 4 года назад +2

      what is the size of charging port on your fujitsu split? is it 5/16 inch?

    • @HVACRTECH-83
      @HVACRTECH-83 2 года назад +1

      @@lordjaashin yes

  • @andrewsimon5437
    @andrewsimon5437 4 года назад +61

    I just used this exact method with the exact two Appion valve core removal tools in order to install a 9000btu mini split. Even with the cheap harbor freight vacuum pump it pulled a great vacuum and held steady; I observed no leaks. As a homeowner I am excited to be able to do some of my own HVAC work. Thanks for these training videos. They are fascinating!

    • @shane2163
      @shane2163 2 года назад +6

      Until the epa shows up to your house lol

    • @andrewsimon5437
      @andrewsimon5437 2 года назад +1

      @@shane2163 so far so good

    • @LichaelMewis
      @LichaelMewis 2 года назад +1

      Excellent, I'm doing the same and plan to install these for my neighbors for a lot cheaper than an HVAC "pro"!

    • @robertlamey7612
      @robertlamey7612 Год назад

      Wish I was your neighbor I’d turn you in

    • @andrewsimon5437
      @andrewsimon5437 Год назад

      @@robertlamey7612 haha to whom, and for what?

  • @harthenry
    @harthenry 4 года назад +51

    I would be more than happy to pay a technician more to charge my A/C if I knew he/she was as thorough as you. I've had a few guys come to our house that just bang on the unit and connect hoses and do not go to this detail (I guess that is why they've been here a few times). If nothing else, your video should be a good lesson to existing HVAC Techs to make videos so that I would feel comfortable in hiring them to come to my home. Not just good info/education for me, but great advertising for the HVAC Techs too.

    • @kiyoponnn
      @kiyoponnn Год назад

      Agreed, I am sick and tired of getting scammed by incompetent morons.

    • @TheMicsaund
      @TheMicsaund Год назад +2

      Agreed - I watch all these videos and wish I could find someone in my area who does such quality work. The large company in my area, who installed my new whole-house system, was skimping on the "annual required maintenance" for the first three years! In the fourth year, the guy said, "hey they haven't even opened this cleaning port" and he had to cut into the insulation to get to a drain pain that was filled with crap and rust already.

    • @paulswift5196
      @paulswift5196 Год назад +13

      That’s why I never hire anyone to do work on my house. I’m better off watching RUclips and learning something new.

    • @paulswift5196
      @paulswift5196 Год назад +6

      My mom hired a guy to clean out her furnace. I just happened to stop over that day and I checked on the camera what he was doing. Watching baseball for 40 minutes banging on the side once and awhile. Lol.. it was great when he came upstairs and asked for 200$ told him to hit the road your on camera watching baseball bud.

    • @ThomasPatton-xk2os
      @ThomasPatton-xk2os 6 месяцев назад +1

      Charging 200 dollars per pound of Freon by 6 lbs 1200 $$ with out touching anything else

  • @jawbrace
    @jawbrace 4 года назад +6

    I love this guy. So smart and doesn't over complicate what he's doing. Kudos to you!

  • @gypsetsalon2585
    @gypsetsalon2585 8 дней назад

    The best and most thorough video I’ve found. I have all the tools just used incorrectly. Thank you.

  • @conradlowther
    @conradlowther 4 года назад +9

    Craig, great video. I purchased your book as well and it’s excellent. I do the same setup with one difference. I hook my service hose with ball valve to the side port on my second valve core tool. I leave the refrigerant bottle valve closed but my service hose valve open during final vacuum so that I am vacuuming the air out of my service hose. Then I close the valve on my service hose right before I turn off the vacuum pump and do a decay test. Then I isolate my vacuum gauge, open the valve on my refrigerant bottle, and use the valve on my service hose to throttle in the required charge. The advantage to me is I have pulled out some of the entrained air and moisture from my service hose by subjecting it to vacuum, and I don’t have to wonder how much air I purged out of the service hose using refrigerant to push it out, or lose any more refrigerant than necessary. There is also air between the valve on the service hose and the valve on the first core removal tool that is impossible to purge normally. I’m interested to hear what you think of this setup and if it makes sense or if there is a downside to the way I do it that I’m not thinking of. Thanks

  • @abaidaramex2818
    @abaidaramex2818 4 года назад +6

    I have installed two zone system just after wactching your videos this was my first job.
    Thanks for sharing your knowladge

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 Год назад +3

    This makes me happy and I look forward to my AC and heat pump unit work. It’s not so stressful when it’s simplified. I really want that book too. I plan on buying any other resources too. I appreciate the videos and knowledge you share, thank you!

  • @rickrockin155
    @rickrockin155 4 года назад +6

    I ve bought 3 mini ductless systems and this really helps me with the installation. I have to buy a few more tools and I'll be ready for the job. Thanks for the vodios they re so helpful, I'm always learning from u guys especially what my instructor in hvac school left out. I didnt know anything about the dry and wet bulbs, he never explained this, so I was always in the dark on how much refrigerant should be in a system.

  • @the1mainconnect
    @the1mainconnect 2 года назад +1

    Right On Great Video. The wanted 700+ to do the final process of my Pioneer Mini Split process. I just built a mobile office from the frame up, I wasn't about to pay anyone for something so simple. I ordered the valve core removers and the vacuum gauge because hey you need quality instruments. I initially ordered a vacuum gauge and pump set off amazon. Big mistake. I couldn't get the vacuum to go under 1000 microns, kept chasing my tail, thought I had moisture in the new system, pump sounded awful too. Eventually ran and got a 2 stage 3CFM vacuum pump from harbor freight and used a line out of the kit to connect, still chased my tail for hours. Almost regretted taking it on myself. Then sat and thought there has to be an issue with the line because vacuum be going down and then up. Changed the vacuum line and bam it was headed in the right direction. Got it down to 160, went back in the morning and it held at 240. I know vacuum is a huge part of it so, I was happy. I didn't nitrogen pressure test. I know I should have but had to try to skimp due to funds. Also key note, in a 2 ton Pioneer mini split, both the liquid and vapor lines have access ports and they are switched from this video. Liquid line is on the bottom. In any case the process worked well and it is blowing cold and hot. Thanks for the detailed video and links!

  • @channelcatchaser9426
    @channelcatchaser9426 5 лет назад +9

    I used the Spin Flair set on my last installation. It works perfectly! I would highly recommend it

  • @hotwort
    @hotwort 4 года назад +11

    Excellent! You are a great service to the HVAC Community Craig. Oh yeah your book is terrific, worth every penny.

  • @scasinger123
    @scasinger123 Год назад +6

    I love your videos. I installed a mini split but messed up one of the flare connections when I shortened the line set, and lost all of my refrigerant. After having several companies come out and give me ridiculously high bids, while berating me for trying to do "this kind of work" as a homeowner, I was fed up. Watched your whole series and learned so much. I realized that of the 4 ac techs that came out, not one knew how to properly evacuate, test and recharge a mini split correctly. And not one wanted to do super heat, saying, "There's no need to do that".

    • @wolfdale_3m
      @wolfdale_3m Год назад +2

      Well, to be fair, handling refrigerant when you're unlicensed is discouraged and even illegal in many places. What you just caused to the environment after letting all that refer into the air isn't something trivial.
      My take is that you can install the indoor and outdoor unit to your heart's content and then call an HVAC technician to assist you in the piping, leak testing, and charging of your system.

    • @scasinger123
      @scasinger123 Год назад

      @@wolfdale_3m Ah, BS, BS and more BS. 2 of the techs that came out planned on letting the rest of the refrigerant out and weighing in the proper amount. I asked them if they used a recovery tanks and they both said something to the effect of "Nah. It's not enough to matter".
      As for "illegal in most places", two of the techs that came out weren't licensed HVAC contractors at all. They are working for an HVAC company under that license under "supervision". I don't know about the other two because I didn't get their full name.
      You should probably bone up on EPA regulations before trying spew nonsense. The whole HVAC industry is a racket. I just found a way around it.

    • @jakekostogiannis
      @jakekostogiannis 27 дней назад

      Do the superheat? Come on. Hire someone who knows.

    • @scasinger123
      @scasinger123 25 дней назад

      @@wolfdale_3m HAHAHAAA! Yeah. Because AC techs don't "add a pound" to units all the time that aren't cooling correctly. HAHHAHAHAAA! Where do AC techs think that refrigerant is going?
      They don't care. They just want to make money. Pfff.

    • @scasinger123
      @scasinger123 25 дней назад

      @@jakekostogiannis Clearly you don't know what measuring superheat is. I would rather learn and do it correctly, than pay a "professional" who doesn't have a clue.

  • @phlogistanjones2722
    @phlogistanjones2722 Год назад

    Thank you so much for the clear and concise information.
    I appreciate that you took the time to both show and tell what you were doing and how it was done.

  • @phishertube
    @phishertube 2 года назад +1

    best explained charging video yet. Thanks

  • @Theendlesssolitude
    @Theendlesssolitude 2 года назад +1

    Clear, fast, detailed and directly to the point! Thanks for your detailed video!

  • @datadogie
    @datadogie 4 года назад +4

    The best tutorial I have seen. I was always concerned about those easy fit mini splits. If the lines are not pre gassed, but the compressor is then this explains a lot.

  • @TheSkyclipper
    @TheSkyclipper 4 года назад +1

    Meticulous Instructions!!
    You have just displayed why it's important to have someone vacuum the lines - and to do it properly!
    Thank you! Awesome video!

  • @MJ-iy4fb
    @MJ-iy4fb 2 года назад

    Great video, each time I watch this I get a little more info. This process was a little tricky getting right, thanks for clearing up the matter for me.

  • @mariusfauru
    @mariusfauru 3 года назад +3

    Thank you for your awesome advices! HIGHLY APPRECIATED!!! 😎👍🍺 installed my 2 split units without problems after watching your videos! Super clear and simple!

  • @micmic9410
    @micmic9410 Год назад +2

    You are amazing in detail. Buying my own tools to maintain my ductless installed. Had a 20 year hvac vet install my line sets and charge, 3 out of 5 leaked. Now he won’t come back after being paid- wants more money and had to call another company. They want about $1500 to do this. But I want to learn. These break downs affect the working class way more than people that have wealth. I saved 13k to get this done and this is what I got.

  • @Enonymouse_
    @Enonymouse_ 3 месяца назад

    Love this, I was supposed to reclass into HVAC while in the military, i'll check your books out. :)

  • @purejdmpassion
    @purejdmpassion 3 года назад

    Very informative video. I do have a lroblem when doing a vacuum procedure. The vacuum pump vacuums to 200 microns but after 10 min it rises to 1000 microns. The flares are perfect and the system is new. Your help is deeply appreciated

    • @jenklingler8169
      @jenklingler8169 3 года назад

      did you receive an answer? same boat here...two unit LGsystem with 70' of Lineset between the two. Two appion VCR tools, 1/2" appion vacuum hose, fresh JB oil in pump. Pulls tight down to 250 then after isolating the system it rises to 800 then down to 790 and holds. Nylog on the face of every flare in both the system and vacuum rig. Don't have access to nitrogen. Does it have to be 500 microns?

    • @MarcelHVAC
      @MarcelHVAC 2 года назад

      @@jenklingler8169 You will be fine as long as it stays under 2000 micron in 30 minutes

  • @Zafarella
    @Zafarella 3 года назад

    Just wanted thank you for the material. You can add a table of contents for ease of navigation imho. Installed yesterday 2 modules using techniques you described.

  • @robertdeming1802
    @robertdeming1802 4 года назад +1

    Excellent video . Now I understand the basics of charging a mini split. Thanks!

  • @toddbehrends1373
    @toddbehrends1373 5 лет назад +5

    Thank you for using your training and knowledge to help us "sometimers" be able to diagnose problems with our home systems so we have a better idea of the trouble when we call a tech to come fix it. Or it may be something that we could take care ourselves. Either way a better understanding of the systems and how they work is helpful.

  • @markcaldwell1245
    @markcaldwell1245 4 года назад +1

    Excellent idea with the bubbles tester cap.

  • @keithwins
    @keithwins 4 года назад +10

    It's the little things... I really like how you show purging every little part of the system and the tools, really great.
    I am fascinated by how short a test it is though. I charge with Nitrogen to 400 lbs, and wait a while if I can. You only took 6 minutes (it took 4m to get to 340) in vacuum! I wouldn't have thought that was enough to be confident. Of course, time is money. Anyway, thanks so much for such a detailed video.

    • @acservicetechchannel
      @acservicetechchannel  4 года назад

      Vacuum time doesn't matter, only the vacuum level and I did a 10 minute standing vacuum test to verify true vacuum level, thanks!

  • @jamesluisitobinoya4856
    @jamesluisitobinoya4856 Год назад

    Thank you Sir, you have a very straight forward explanation.

  • @themayorofairconditioning2868
    @themayorofairconditioning2868 2 года назад

    These videos are excellent. You're really a master of this stuff.

  • @isldsnow
    @isldsnow 4 года назад

    I'm sure my neighbors got tired of listening to this as I was looping this video while i was doing the job. Thanks

    • @floatybyboaty
      @floatybyboaty 3 года назад

      Same here. Been following all of their Videos and although i have purchased the F Gas manual, theirs is a must.

  • @stebarg
    @stebarg 3 года назад

    Great stuff!!! Almost perfect! The best description I've seen so far.

  • @waltbe
    @waltbe Год назад

    There is good info in this video - thanks. Micron, as used here, seems to be a term of trade. As used here, as a unit of vacuum instead of distance, there are 1000 microns to a torr (1 torr= 1 mm Hg). Atmosphere is 760 torr or mm Hg.

  • @alfredoandroid357
    @alfredoandroid357 4 года назад

    Thank you
    Thank you
    Thank you
    I follow your video and how to pressure test and vacuum, my system work out great .
    I didn't see a donate page or email address for me to send you a donation or tip via PayPal so I just brought your book on Amazon the
    $59.00 ac book . Thanks again appreciate the help .

  • @stuzman52
    @stuzman52 5 лет назад +4

    Great step-by-step procedures Craig and keep up the good work!

  • @robmedearis8700
    @robmedearis8700 2 года назад +3

    If you are recharging the system after evacuation and vacuum do you recharge with the valves closed or open?

  • @da324
    @da324 2 года назад

    I installed a 9000 BTU Senville. A friend in the HVAC field came over to pull the vacuum. We're in Fl. and it's fairly warm right now, but his pump was a single stage and it took forever for the micro gauge to get down to around 300. Other than that, he used the same equipment and procedure as you. We ran the unit after we released the refrigerant and it is super quite and super cold. He left and is out of town, but I read that I need to run the heat at some point after initial set up for 5 minutes. I only had the unit on for about 2 hrs after initial set up on auto cool. Today, I turned it on and it was blowing cold quickly I switched the mode to heat and the fan shut off and the door on the front of the inside head unit closed halfway. I waited for a minute or so and went back to the other function and everything worked. All other functions on the remote work and everything is wired right, was hoping you may have some insight to why there's no heat? Thanks!

    • @cruisemates
      @cruisemates 2 года назад

      I'm not a tech but I recall reading that it takes 5 minutes for the air to start blowing inside because the system needs time to reset the flow of the R410a so it is carrying heat to the indoor unit instead of cold.

    • @da324
      @da324 2 года назад

      @@cruisemates You're exactly right. I wasn't giving it enough time. Thanks

  • @chriscermak3188
    @chriscermak3188 5 лет назад +1

    Another great video Craig. Thanks for explaining the 5/16 fitting.

  • @captainmikek6172
    @captainmikek6172 3 года назад +1

    Thanks Craig, you're and excellent instructor!

  • @mazarat4768
    @mazarat4768 4 года назад +1

    Great. I wish these materials were in Turkey. But even if he's here, it's too expensive. Your stuff's beautiful.

  • @johnathindonelson4064
    @johnathindonelson4064 Год назад

    Another Great Video Ordering The Book Tonight

  • @Est-lj4tq
    @Est-lj4tq Год назад

    Clear and concise!

  • @seymourscagnetti1413
    @seymourscagnetti1413 2 года назад

    Nice. Real pro techniques. Well done.

  • @quimshtgclg
    @quimshtgclg 4 года назад

    I think my next leak detector will be an Accutrak detector . They are very precise .

  • @floridasaltlife
    @floridasaltlife Год назад

    Brilliantly well presented, subscribed

  • @DaveArms
    @DaveArms Год назад

    I would have liked to see you include an inspection of all hose seals (o-rings) in every connection and oil them as needed.

  • @LLl-hh3qy
    @LLl-hh3qy 2 года назад +1

    You are telling that by removing the valve core you get a faster and deeper vacuum. I understand that it is faster but why deeper? Waiting long enough should lead to same results. Or am I wrong? Great video, so on point and clear.

  • @wangfred
    @wangfred 3 года назад

    that is the real training, subscribed!

    • @acservicetechchannel
      @acservicetechchannel  3 года назад

      Thanks Fred! Glad you enjoy the channel! We have resources over at www.acservicetech.com too.

  • @johnlynes4453
    @johnlynes4453 4 года назад +6

    HI Craig, your videos are the best I have seen. I love this set up because this is the only thing I do when it comes to HVAC, i.e., setting up new mini splits, and this set up eliminates the need for using a manifold gauge set which introduce more potential for leaks and contamination from oily gooey heavily used guage sets. Video request, please do one on the entire Nitrogen pressure test.
    Support Craigs VIDEOS, I bought all the tools with your links! One tool that I bought not on your list is the metric Master Cool mini split torque wrenches. (The line sets that come with the units are metric or SEA on the OD of the nut, but if you buy a set at a local supply house in the USA the OD on the nut will be SAE but the threads will be the same. Therefore, you would have to buy the Master Cool SAE set).
    One question, In a brand new system, If I am not adding any new refrigerent in, would I reinsert the valve core after I release the refrigerant from the compressor for the first time after isolating the micron gauge?
    Thanks again and everyone buy the tools from his links!

    • @acservicetechchannel
      @acservicetechchannel  4 года назад +2

      Thank you very much and you would add the valve core after there is positive refrigerant pressure in the system thanks!

  • @harveybrimer1054
    @harveybrimer1054 2 года назад

    Verry informative, thanks for posting!!!

  • @leodonahue9688
    @leodonahue9688 2 года назад

    Thank you, you are a consummate Professional.

  • @paulcrescenti5581
    @paulcrescenti5581 4 года назад

    I have not had to deal with an initial charge on any AC units. In a perfect world, my future AC guy would be as careful and precise with evacuation, charging, and startup as you are.

  • @dannyf4995
    @dannyf4995 2 месяца назад

    A nice video, however, I must admit that I've installed 10 mini-split units in my house, and they have lasted for years, and I've never vacuumed new air conditioners. When you do this job right (proper connections to lines), you don't need to go through a vacuum process and just purge the system. After releasing the gas from the source line, you have to bleed the system (purge process) through the valve for 8 to 10 seconds. and that's it.

  • @mihaipopa9414
    @mihaipopa9414 Год назад

    Splendid presentation, thanks!

  • @TokyoCraftsman
    @TokyoCraftsman 5 лет назад +1

    Here in Japan most of the guys use this tool that threads onto the service port, and you attach the vacuum hose to it, then you turn a knob with depresses the Schrader valve in the service port and then they vacuum the lines and head unit. They usually will let it pump for 10-15 min. They have no vacuum gauge attached anywhere, maybe there is one on the vacuum pump but, but often no gauge at all. I spent the money and bought the two valve core removal tools you have and the CPS Micron Vacuum gauge too. I could pump down my lines and head unit to 310 microns, but after 10 min with the valve core removal tool turned off to isolate the vacuum pump, the reading was 300 microns. That should be good to go, yes?
    My problem with all of this is the ability to pressure test. I don't do this full time, it is one of the many things I do here in Tokyo, another service I offer to my non-Japanese clients is the removal and installation of aircons, 100% mini-splits. I have seen a lot of Aircons installed here and I've never, ever seen anyone do a pressure test. Looking in the catalog from an Aircon supply company they do sell the nitrogen bottles and the regulators, but they cost $500 for the bottle and then $50 to refill it. I'll have to spend the money at some point, but I really don't have the cash on hand right now.
    My question is, can I use CO2 to pressure test? I have that gas in abundance, I use it on my MIG welder and my wife's family run a liquor shop and I can get a smaller bottle of CO2 used for the draught beer machines easily. If I use CO2 to pressure test and then I vacuum out the lines and head unit, would that be OK?
    I feel that I already know the answer and it's no, but I thought I'd ask, LOL
    Oh, would Argon work? I have Argon for my TIG welder.
    Love these videos, bought the E-book and I'm learning a lot.
    Thank you VERY much for your time.
    Cheers from Tokyo!

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +1

      I don't use CO2 or argon but some techs here do use them. As long as it is an inert gas and it does not leave humidity in the lines that needs to get vacuumed out then it is ok but make sure not to over pressurize the systems though, thanks for your comments and desire to do the processes correctly for the customers and for the sake of your name!

    • @TokyoCraftsman
      @TokyoCraftsman 5 лет назад +1

      @@acservicetechchannel I again Craig, thank you so much for the information.
      Turns out I did not have the correct fittings to connect the CO2 bottle to the system, so I did not use the CO2 to pressure test.
      I talked to a Japanese guy that does a lot of these mini-splits, he said that for the mini-split since there are only a total of four connections and they are very straight forward it is unusual to pressure test them. Larger industrial or commercial AC or refrigeration setups with lots of connections and joints, yes they are pressure tested.
      Things are done differently here, I guess.
      What he did suggest was that I do the vacuuming of the lines and head unit then I open the valve on the liquid, small line to release refrigerant for maybe 5 seconds, into the system, then close the valve again. Then I could do my bubble check on the joints, but he thought this was overkill.
      Using the two valve core removal tools and the CPS vacuum gauge I vacuumed the lines and head unit. I got it down to 54 microns, (took a picture!) and then I isolated the vacuum pump from the system and waited 10 min. The gauge normalized at 100 microns. I then waited another 10 min and the gauge still read 100 microns.
      I did just like you show and I isolated the vacuum gauge with the 1/4" valve removal tool and then I opened the valves from the compressor unit to allow refrigerant into the lines and head unit.
      Question, do you usually hear any sound when you do this, like a gurgling sound? When I did it there was no sound at all...?
      I then replaced the valve into the service port, had to push fairly hard against the pressure in the lines, but it worked, I checked the valve for leaks, there were none. I then checked the other flare joints for leaks with the bubble stuff, no leaks.
      Good to go, the client is happy and so am I, your setup works really well, and super slick.
      Thank you again!
      Cheers from Tokyo!

  • @chodge8366
    @chodge8366 4 года назад

    love the two valve removal tools in tandem. great idea!

  • @ramonnote1997
    @ramonnote1997 4 года назад +1

    Excellent video I learn really good keep doing it !!!

  • @sushilchoudhary5749
    @sushilchoudhary5749 4 года назад +1

    Thanks for informative video.

  • @mrgoggles1963
    @mrgoggles1963 3 месяца назад +1

    Hello. Great video. Question about adding refrigerant. Scenario: full evacuation of 410A from a multi zone mini split/ nitrogen pressure test/ vacuum down to below 200 um and hold. If one needed to add /weigh in the full factory charge of fresh 410A to the mini split in this scenario, would they add as a liquid and all of it, example 95 ounces 410A. How quickly would that adding process be…continuous until the weight added was achieved??? or slowly and a little at a time??? If so…how slow…5 oz at a time??? 20 oz at a time??
    Second question: The valves of all the zones should be back seated (opened) previous to adding, as the line sets (25’) are not enough to hold all of that refrigerant, correct?
    Thanks!

  • @lionheartchannel5842
    @lionheartchannel5842 3 года назад +1

    Thanks for sharing this video nice tutorial.

  • @brenthann2623
    @brenthann2623 Месяц назад

    super great video. thanks so much

  • @steyer-crmg
    @steyer-crmg 2 года назад

    Awesome video thanks! I always wondered what it meant to gas an aircon.

  • @DowningStreet205
    @DowningStreet205 4 года назад +1

    What a great video.

  • @NewShockerGuy
    @NewShockerGuy Год назад

    It would be nice to know where you got the gauges, adapters and things like that. EDIT: Just came to the video that said the parts are linked! Awesome! I will check it out when I get home... work is blocking all the links.
    I'm a homeowner but plan on installing my Mitsubishi mini split in my garage. I'm being quoted $8k for a 18k BTU system and I can buy the system for $3800... $4,200 they are charging in labor, so I have ZERO issues buying all the tools needed to be able to do exactly what you are doing. Even if I spend a grand or two on the tools, I am still coming out ahead knowing that it's done properly and not rushed.
    That's the biggest thing I see now when having work done. It's rushed and not thoroughly checked/completed. If I am doing the work I can take as long as I need to ensure that it's done correctly and 100%, rather than paying someone to do said job and find out months later that something was skipped or not done properly.

  • @WallaceRoseVincent
    @WallaceRoseVincent 3 года назад +1

    Yeah! AccuTrak!

  • @SatanIceCream
    @SatanIceCream 4 года назад +2

    Good video... I appreciate that mah brah... peace from sunny SoCal 🖐🏾

  • @ΓΙΩΡΓΟΣΠΑΣΧΑΛΙΔΗΣ-ο9φ

    You Are My Hero

  • @DeepakGupta-cz4rh
    @DeepakGupta-cz4rh 5 лет назад +1

    Very helpful video for coreremove valve

  • @crowderglen
    @crowderglen Год назад

    I am from the UK and a newbee to the air conditioning world. From the few people I've spoken to in the trade and from watching UK mini split installations on RUclips, the trend here is that less than 4000 microns is an acceptable vacuum level. All of them are using a gauge set and 1/4" hoses. I've followed Craig's steps and my last vacuum achieved 280 microns on a mini split with a 4 metre line set length. This was measured with a Fieldpiece MG44 vacuum gauge and Navac 1/2" hose and Navac core removal tools. After the vacuum I found oil in the hose and wondered if this is normal?

  • @CasaDelGato
    @CasaDelGato 2 года назад

    Failed recharge. sigh.
    I recently installed a new Senville 18K btu unit. Did a 1.5 hr vacuum test, no problem.
    Finished setup and started the system running. (note: It's winter!)
    It started heating just fine. Then I got a call and had to leave for six hours.
    Came back - and it wasn't heating anymore.
    Turned it off, and checked the Freon pressure. it was 0. Apparently the system developed a nasty leak somewhere.
    Since I had shortened the lineset (I only need about 20'), I assumed my flaring job wasn't good enough.
    Due to shipping snafus, I had a spare lineset (25'), so I just replaced my shortened one with a factory built one (and looped it).
    Since I had to wait for the Freon to arrive, I did a VERY LONG (4 day) vacuum test. It held vacuum.
    It's 36 deg F outside.
    Since there was no freon and I didn't want to run the compressor when empty, I did a slow fill to 100psi.
    Then powered up the system, and was able to fill it to 115psi. Wouldn't go higher. (freon too cold??)
    Yes, it's in Cooling mode - as I do have an alternate heat source in the house.
    Let it run for 15 minutes - no cooling, blower running inside, the fan on the outside unit is NOT running, but I can hear the compressor running.
    Pressure hasn't changed.
    Tried flipping it to Heat mode, and waited 15 minutes. No heating inside, inside blower running, outside fan and compressor running.
    No heat. Pressure hasn't changed.
    Gave up and shut it all down.
    Any suggestions?

  • @melvinl.yarkabo4113
    @melvinl.yarkabo4113 Год назад

    Thank you for education

  • @bobrebera494
    @bobrebera494 4 года назад +1

    learning never gets old-good job

  • @anthonyrodriguez243
    @anthonyrodriguez243 4 года назад +1

    Great videos

  • @craccky
    @craccky 2 года назад +3

    Just wondering how much of that 2.3 ounces of referigerant could have gotten waste inside the hose instead of getting into the system. This becomes more substantial when you are adding the entire amount of referigerant, say after the previous one has leaked.

  • @egemensuzgun4208
    @egemensuzgun4208 3 года назад

    i’m glad to see your using CPS gear, i’m about to buy CPS gauges and a 2 CFM vac pump

  • @sublimefreak2244
    @sublimefreak2244 2 года назад

    Very good video

  • @jacarandamama7318
    @jacarandamama7318 3 года назад

    THANKYOUTHANKYOUTHANKYOU! Going to try this on my newly installed minisplit. Will let you know.

  • @Eddy63
    @Eddy63 5 лет назад +1

    You should write a book Craig ... Lol ... Great vid as usual ... Much appreciated ...

  • @حسين-ج9ط7ي
    @حسين-ج9ط7ي 5 лет назад +1

    شكرا اخي انته حقا مبدع في عملك

  • @martinguigou5313
    @martinguigou5313 4 года назад +3

    Thank you for the tool list, I will order the books soon!

    • @acservicetechchannel
      @acservicetechchannel  4 года назад

      Great and please feel free to ask questions! The full outline of the book is available at www.acservicetech.com/ac-book thanks!

  • @votrunghieu4099
    @votrunghieu4099 2 года назад

    R-12: This is typically in older vehicles built before 1994
    R-134a: Adding additional molecules to the R-12 formula has created a more environment friendly refrigerant which is now being phased out
    1234yf: The latest and even more environment friendly refrigerant is flammable (the earlier predecessors r-12 and r-134a or not) this will be a much more expensive substance. Due to this flammability most German cars have opted to stay with R-134a sighting potential fires in front end collisions. In 2014 this refrigerant has begun to be phased in. Most system will have a label or ticker identifying the refrigerant used.

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem 4 года назад

    I Love this channel
    ❤❤❤❤❤

  • @ttluis051
    @ttluis051 4 года назад

    your the best

  • @Kntryhart
    @Kntryhart 4 года назад +1

    Good stuff! Thanks!

  • @PLVtv
    @PLVtv 5 лет назад +1

    Thank you very much for your time and effort

  • @umargul5644
    @umargul5644 2 года назад

    Great 👍 thanks

  • @chrisb9363
    @chrisb9363 3 года назад +1

    Good video

    • @acservicetechchannel
      @acservicetechchannel  3 года назад

      Thanks for the visit

    • @chrisb9363
      @chrisb9363 3 года назад

      @@acservicetechchannel definitely subbed I do this in Ohio brother keep it up

  • @AaronHadleigh
    @AaronHadleigh 4 года назад

    Great video mate,Subscribed. I worked for a union trained tech and can see you know your stuff.

  • @raymondbailey7045
    @raymondbailey7045 4 года назад

    Great videos. Keep up the good work.......

  • @grumpyg9350
    @grumpyg9350 4 года назад

    Nice video!!!

  • @cookieboi4449
    @cookieboi4449 4 года назад

    excellent demonstration,,,, this job is only for trade people who have the right tools. My way: The new refrigerant R32 is compatible with R290 (which I believe is pure propane). All cooking gas in Aus is pure propane. I have a vacuum pump,,, but why bother? why not send propane through the pipes in order to vacate the air? then open the valves and check for leaks, 5 minutes job.

  • @luiselizalde6757
    @luiselizalde6757 5 лет назад +1

    Excellent thanks

  • @jesseosterhout907
    @jesseosterhout907 3 года назад

    His book is only worth it if you work in Hvac or want to, or trying to pass Nate test or expand general knowledge of ac service procedures.. other than that my wife and daughter fall asleep when I read it aloud. ;-) We can be such nerds ! Haha. All in the name of getting better and learning. The install crew laughs at my nightly reading until they see my check stub. Seriously though they’ve never seen it but they know about the service tech life, the pay and often times they want no part of it. The hours, the responsibility, the stress of ordering and installing a $300 to many thousands of dollars in parts knowing that you have to be right. Don’t be a parts changer. Your career will be limited doing that. Figure out why the part failed or you will be back to replace the same part that was a symptom not the cause. I owe ac service tech A LOT! Thanks!

  • @saveriotranquilli929
    @saveriotranquilli929 5 месяцев назад

    This video is amazing! Thank you! Is the same procedure also valid also for a multi split with branch box?

  • @wbriggs111
    @wbriggs111 4 года назад +1

    That was good but what about the 410 that was weigh out and still in the yellow hose that never got in the system?

  • @alfredoandroid357
    @alfredoandroid357 4 года назад

    Some tips for the noobie diy out there
    Make sure to pay attention and set the scale to oz or lb before you release the gas , maybe a sticky note in front of the scale . However you figure the math on how much gas you are putting into the system in oz or lbs.
    If you have a 2 zone mini split ac
    A and B or two air handlers.
    Do yourself a favor and first vacuum and pressure test both zones before you release and add gas .
    The reason I say this is , if you not paying attention when you go to release the gas you might release the gas on zone B thinking it was zone A if you didn't vacuum both lines now you have refrigerant in a unvacuum line .
    They are right next too each other and the heat of the moment you might get confused , maybe put painter blue tape on zone B valve so its clearly different from zone A