Acha ji really great *Thanks for watching and please share this video's link on your watsapp group and keep watsapp status and if not followed them please follow*
Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..? The column to column distance is 15 feet. How many storeys can be built with this much reinforcement..?
9inch×12inch k column mein 4 bars 16 dia k aur center k 2 bars 12 k hone chahiye for load carrying, Ring 8 mm ka 175 c/c rakhna chahiye, Steel frame use karein for molding, Cover 30 mm ka Best of luck
Very useful information sirr thankyou from Nepal 🇳🇵🇳🇵
Most welcome
Very nice information 👍👍👍👍👍
Thank you
Can I construct 10x15 inch column using 16mm 6 rod in the stan of 13x18 feet for G+3
Great knowledge for us sire👍🏽❤️👍🏽
Two column ke bich ka maximum distence 18 ft h to colomn and beam ka kya size lenge or kitne ka seriya denge
15"*9" ke column pr kitne floor tk safe hai construction krna ??aur kitne mm ke saria use krna hai...PLz reply soon thankyou
Good knowledge ❤️👍🏽👍🏽
Hi sir I have small doubt about column . can I use 15”/9” columns ( 4 main bar : 16MM and 4 no. Of 12mm ) for 3 floors
Distance’s off 12’ feet’s by 18’ feet’s
Sir can we use robosand for pillar and slab
By 4 16mm and 4 12mm can we build 4 floor
9×9 inch colombs with 8 nos rods 16mm 6 n 12 mm 2 .... can I built G+2 ... 18 COLOMBS 1500 SQ FT SLAB
Hamare yahan ek building hua hai jo 10 by 15 inch column me 15 floor tak banay hua hai
Acha ji really great
*Thanks for watching and please share this video's link on your watsapp group and keep watsapp status and if not followed them please follow*
8×12 room size 3 story building kelye colom ke lye 12mm 6pc steel de sakta he kya
Good information
Good sir ❤️
kithana inch Ka pillar sir please price
What is column size
9 by 15 inch 16 mm 6 bars 8mm stirupps
Sir
G+2 base area 1500 sqrfeet for ech floor
Minimum colume size and reinforcemt dia plz..
??
Coulunm ki facing kis trah lena .matlab vertical ya horizontal
Depending on your column to column distance
corner column mai footing kasey provide kar tey hai ???
Coloumn per admixture use hua hai ki nahi ?
Sir slab keliye m20 hai kya
Meanc cement ? , sand ? And aggregate ?
Sir 9*12 k colum k liye ring ki size kya honi chahiye
Ectreme weather conditions... only in civil engineering field 😫😫😟😨😨😵😵
Ring ka lenth and width Kitna h
Pillar size 9 by 15 raha tao ring sizee 6 by 12 laena
Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..?
The column to column distance is 15 feet.
How many storeys can be built with this much reinforcement..?
Sir 4 12mm and 2 10 mm rods column size ?
9*9
9x12'' me 4 baar 12mm with M15(1:2:4) use karsakthe.?
9inch×12inch k column mein 4 bars 16 dia k aur center k 2 bars 12 k hone chahiye for load carrying,
Ring 8 mm ka 175 c/c rakhna chahiye,
Steel frame use karein for molding,
Cover 30 mm ka
Best of luck
Khal kitna khode
Good
28*36 South face and two shop & two room rent wise commind lethboth
Bhai sab hum log bhi kam sikhna chahte h aapke pas hum log delhi se h
20 /100
g3 ka h ky
Sushant bhai...Rod Size nhi bataya aapne..? Rod size kitna mm hai..?
16 mm and 12 mm
15 ft span rakh sakte
Sir Mera pillar size 9*12 hai 12mm 6 bar hai ring 6mm hai think hai ya Nahi plz reply
Kitana floor hai
@@virendrarawat2479 G+1
@@virendrarawat2479 for 3rd floor
A column size
9 by 15 inch
Susant bhai 1st floor me sirf coloumn uthaka chhaat daldene se koi problem hoga kya brickwork aur finishing baad me hoga to please bataiya
Search for frame structure column beam and slab
@@Life_is_Awesome_Civil sir per video me thik sah malum nahi chaal raha hai aap bataiya na coloumn uthake chhat dalne se baad me koi problem hogi kya
G+3 hai ya G+2 hai sir ji ???
uhi pta ni chl rha
12mm Rod se 3rd floor Tak jaa sakte hain kiya
No
No
5 inch coloum de sakte ha kua 3 floor ke liye
Yes
Sir nima number bekagide
Which size steel use in collums for 2or3 floors