How to Find Depth of Foundation for House? - Minimum Depth of Foundation

Поделиться
HTML-код
  • Опубликовано: 23 дек 2019
  • Follow me on :
    Facebook :
    / thestanikzai
    Instagram :
    / thestanikzai
    How to Find Depth of Footing
    How to Find depth of foundation
    House Construction
    Steps for House Construction

Комментарии • 134

  • @karimedutainment5861
    @karimedutainment5861 2 года назад +13

    Sir, is it possible you make a chart or a table for all the requirements for beams and columns, their size, spacing, steel dia, number of steel bars, size of footing, type of footing, depth of footing, sbc, conc grade etc.. for domestic and commercial buildings from G+1 up to G+10?
    It will be very helpful and we will appreciate.

  • @jamescurry245
    @jamescurry245 4 года назад +1

    That's a very finding solution to know the depth of foundation is clear.base on the sapmle formula to build that.

  • @harleyasimpledesigns2806
    @harleyasimpledesigns2806 4 года назад +6

    *That formula is applicable if the column has a pin support and no moment at base other wise you need to include the moment which the porduced by lateral loads such as earthquake and wind.*

  • @piotrbrzdek1106
    @piotrbrzdek1106 Год назад +1

    Nicely explained
    The question arises whether the 0.00 level of the building is raised in relation to the ground, e.g. 0.5 m up.
    How to read the foundation level according to the formula (whether in relation to the construction embankment or in the native soil)
    E.G. calculated foot depth 1.5m. , whether to count relative to the native soil or relative to the 0.00 level?

  • @mohamedabdalla3246
    @mohamedabdalla3246 2 года назад +2

    The assesment of an effective depth of foundation is usually one of judgement or design office procedure but a ratio of width of base to overall thickness of 5 is fairly a good starting point. In rectangular section the width is taken as the shorter side.

  • @abrahamdemissie9747
    @abrahamdemissie9747 4 года назад +3

    Great job ! Sir

  • @longjamranjit1682
    @longjamranjit1682 3 года назад +4

    Very precise and the simplest way of explanation.Thanks a lot brother.

  • @mannykay1150
    @mannykay1150 4 года назад +6

    Very well explained, thank you!

  • @prasadsatamarchitectinteri7808
    @prasadsatamarchitectinteri7808 4 года назад +1

    So useful information sir

  • @karimedutainment5861
    @karimedutainment5861 2 года назад

    Watching from Kenya, loving it.

  • @migafia1198
    @migafia1198 4 года назад +2

    Thank you, very good explained.

  • @sarojkumarsahoo4553
    @sarojkumarsahoo4553 4 года назад +12

    Sir, in practice or at a particular site how to know the value for angle of Repose.

  • @mohammadkhorshedalam133
    @mohammadkhorshedalam133 4 года назад +3

    very helpful. thanks

  • @mohamedgamuute2511
    @mohamedgamuute2511 4 года назад +1

    Sir thanks very much for your help. 🙏👍🕋🕋🕋🕋🕋🕋🕋🕋🕋.
    GOd bless you.
    INSHA ALLAA YOU WILL BE IN JANNA FARDAWSA .

  • @ayadjasim9911
    @ayadjasim9911 4 года назад +3

    Excellent my brother .. we hope to make video about dimension of column for 1-8 story .. thx alot

  • @edenalemayehu3438
    @edenalemayehu3438 3 года назад +1

    Great video plss keep it up

  • @manasatawalesu391
    @manasatawalesu391 4 года назад +1

    Thank you Sir, helps a lot.

  • @kasanguinta3901
    @kasanguinta3901 2 года назад

    Excellent. Shukran

  • @kcong1437
    @kcong1437 3 года назад

    Good n clear teaching

  • @RP-nc5ev
    @RP-nc5ev 3 года назад +1

    Great schooling thanks!!!

  • @Engineering_learners
    @Engineering_learners 3 года назад

    Well done sir❤️

  • @rabijohnson2730
    @rabijohnson2730 4 года назад +1

    Thank you sir for your video

  • @abdulwahabtunga2469
    @abdulwahabtunga2469 4 года назад

    Assalamo alaykom Sir. I'm thankful for your lecture on depth of foundation. My clarification is, would I use the actual information from the fresh soil sample extracted right from the site?...meaning the angle of repose of the soil it actually creates, and the density without removing the moisture content of the soil sample ? Or imperative to bring the sample to a laboratory? Why I am raising this clarification is because there are construction sites the water is with in the range of the foundation depth. Shukran.

  • @phyohtetkoko929
    @phyohtetkoko929 Год назад

    Thanks For Teaching Sir

  • @tanusreemaji2873
    @tanusreemaji2873 4 года назад +10

    How to calculate the total load(L.L+D.L) for a residential building?

  • @teamleader6620
    @teamleader6620 3 года назад +2

    Excellent .. plz can we consedration this formula for thickness of footing or raft foundation in same time ? ..Thx

  • @premkhan4785
    @premkhan4785 4 года назад +1

    I understad clearly bro. Thank u

  • @user-ch4dl7je9v
    @user-ch4dl7je9v 3 года назад +2

    Can't get enough of that 'DEPT..thh of foundation'

  • @abeltaame4408
    @abeltaame4408 4 месяца назад

    First of all I would like to express my appreciation for your support.
    We are in a proses of building G5. However we are making a mistake when we aligned the foundation column from 5 to 10 cm. The pad is poured with concrete but the columns are not poured yet.
    Q.1- is it ok to bend the rebar to fix the alignment? If so what is the recommended or the min and the maximum limit to bend the rebar
    Q-2 how deep we have to chisel the foundation pad to bend the rebars and is additional support required ?
    Thank you ! I would look forward to get the information

  • @DeepakGupta-cw7ez
    @DeepakGupta-cw7ez 4 года назад +1

    Thanks sir 🙏

  • @user-dm7bk5oc2n
    @user-dm7bk5oc2n 3 года назад

    Very good advice

  • @peterzimba26
    @peterzimba26 8 месяцев назад

    I enjoy your lectures

  • @masterman280
    @masterman280 3 года назад +2

    Thank you!!

  • @goodshorts333
    @goodshorts333 Год назад

    EXCELLENT BRATHER..... GOD BLESS YOU IMMENSELY

  • @deorajajay
    @deorajajay 3 года назад +2

    Can you please explain if the building having basement...this will apply or any other calculation to be added into it... please clear my doubts

  • @srinivasareddy4403
    @srinivasareddy4403 2 года назад

    Thank you Sir, very Nice lecture

  • @joseloturiano9532
    @joseloturiano9532 4 года назад +2

    how many bags of cement for 1.5 x 1 meters depth footing or how thick should be concrete cement for this footing

  • @ayoubenaciri
    @ayoubenaciri 4 года назад +1

    Thank you Sir

  • @rabijohnson2730
    @rabijohnson2730 4 года назад +5

    Sir the unit of load p should be in Newton and not in kg / m2 because then it's pressure

  • @shafeerminha473
    @shafeerminha473 2 года назад

    Super video

  • @michael9905
    @michael9905 4 года назад +1

    Whats the depth of foundation should be for a house of modern bricks with 3 bedroom, 1 bath, living, dining and kitchen. Allowance should be considered for putting a second floor in the future with the same amount of unit and considering walls to be the standard height of 9 ft?

  • @kumarshashi1849
    @kumarshashi1849 2 года назад

    This vedio is very good for our knowledge. So please do next vedio about desing of slab and beams for building. Thank you so much sir.

  • @myk-izhargroupicpl3749
    @myk-izhargroupicpl3749 3 года назад +1

    Thanks for sharing the video. Please advise us Depth of Foundation and Depth of Footing - what is the difference?

  • @rasoolahamedshaik4551
    @rasoolahamedshaik4551 4 года назад +5

    What about stepped footings depth same as rectangle or any other method plzz replyy iam waiting sir...🙂

  • @FZ63
    @FZ63 Год назад

    thanks you so much sir. for your valuable informations

  • @subashgovin6114
    @subashgovin6114 4 года назад +2

    Sir, what is the angle of friction unit ,can you explain plz....

  • @judechofor6659
    @judechofor6659 3 года назад +1

    Is it for each footing of the foundation or that with the most structural load?

  • @fahimshah2858
    @fahimshah2858 4 года назад +1

    Sir beam main hum nay L/16 raka hain L is length hain ye 16 kia hain plz explain ?

  • @sandipganga4750
    @sandipganga4750 2 года назад

    Great explanation. 👍

  • @yeabaychora3243
    @yeabaychora3243 3 года назад +1

    Aselamualykum werahmetullahy my brother,how can determine the depth of foundation for masjid minara?

  • @channabasava3739
    @channabasava3739 4 года назад +1

    & also how to find the structural load of building

  • @gaetannguepi7546
    @gaetannguepi7546 3 года назад +1

    Thanks a lot

  • @creationmixed1338
    @creationmixed1338 2 года назад

    Aijaz sab

  • @edwinseracarpio9328
    @edwinseracarpio9328 3 года назад +2

    GOOD, TEACHING ON CIVIL ENGINEER IDEA.

  • @rananaveed9777
    @rananaveed9777 4 года назад +2

    You did not mention if there is filling at foundation site

  • @engineers_passion
    @engineers_passion 4 года назад +2

    Thank you, sir!

  • @tsheringyangdon1977
    @tsheringyangdon1977 3 года назад +1

    what will be the depth of footing pad for 3-6 storey residential building la?

  • @Nick505x
    @Nick505x 2 года назад

    I have learned somewhere that its soil bearing capacity upon density of soil

  • @CAMIDRCS
    @CAMIDRCS 3 года назад

    How deep should a G+12 building with 300 metre square area should be in good soil condition?

  • @sanwaikiat618
    @sanwaikiat618 2 года назад

    hello sir, can I know is this formula applicable for both deep and shallow foundation?

  • @venkateshacchary.g6950
    @venkateshacchary.g6950 2 года назад

    Mr White Board is invisible?????
    But u r Formula is Great 👍👌
    Use best video camera 🎥 sharp Pictures 📷

  • @jsk7553
    @jsk7553 Год назад

    thank you

  • @nkwetatibet1774
    @nkwetatibet1774 2 года назад

    How can we determine the bearing soil to place the footing?

  • @semiraseid5782
    @semiraseid5782 3 года назад

    thanks alot

  • @jigarpatel1727
    @jigarpatel1727 4 года назад +2

    👍👍

  • @jeevanandham2528
    @jeevanandham2528 3 года назад +4

    Dear sir, Kindly note.. IS means not Indian standard..SI means International standard.

    • @isiboraikpehae8218
      @isiboraikpehae8218 Год назад +1

      He is resident in India , so he is making reference to Indian code.

  • @piotrbrzdek1106
    @piotrbrzdek1106 2 года назад

    Explained nicely
    but these values ​​from the example of 1500kg / 1m2 are probably a wooden hut with a reed roof :-)
    Greetings from Poland

  • @tanveerahmedmerih4147
    @tanveerahmedmerih4147 Год назад

    Bhai aap bohat chota chota likhtay hen dosra ink b light mobile fone per bilkul b pada NAHI jata plz

  • @layansaleh2986
    @layansaleh2986 2 года назад

    thank you too much

  • @anzormagomadoff250
    @anzormagomadoff250 3 года назад +1

    Wa'aleikum Assalamu!

  • @jeyamaruthucivil2708
    @jeyamaruthucivil2708 4 года назад +1

    Sir pls upload the difference between one way and two way slab and crank bar details

    • @robertodhiambo2204
      @robertodhiambo2204 7 месяцев назад

      am also waiting this sir ,its always tricky on site

  • @premasiriwaduge2186
    @premasiriwaduge2186 2 года назад

    Sir what is the depth of foundation and length & breadth for single story house.

  • @zinabugetaneh6764
    @zinabugetaneh6764 3 года назад

    Thanks

  • @santoshsahoo618
    @santoshsahoo618 3 года назад +1

    How to calculate structural load ?

  • @rasoolahamedshaik4551
    @rasoolahamedshaik4551 4 года назад +1

    Building load must be in newton not in gram i think..

  • @tanveerahmedmerih4147
    @tanveerahmedmerih4147 2 года назад

    Bhai aap likh bada chota rahe hen mobile k through bil kul pda jaraha he font size bdahen

  • @hollywoodamazingmovie3173
    @hollywoodamazingmovie3173 3 года назад +1

    Is code to hme v pata hai j batao konsa is code hai

  • @eduardopare-vlog
    @eduardopare-vlog 2 года назад

    Rankine Formula is not always mandatory to follow for the footing embedment depth requirement
    it depends on the foundation overall stiffness & arrangement to resist the vertical & lateral loads acting onto the building
    for the determination of P in the Rankine Equation -- it should be correctly calculated relative to each Column Applied Axial Loads
    otherwise - the resulted required depth of footing would be so deep & not realistic !
    correct understanding & application of the Rankine Formula should be acquired !

  • @user-vb2kz6zn5z
    @user-vb2kz6zn5z 10 месяцев назад

    Thank you teacher. Is it possible to receive a certificate

  • @johneduardgerona4458
    @johneduardgerona4458 4 года назад +5

    How to know finding a angle of repose in actual.

  • @user-gc8xr3fc8n
    @user-gc8xr3fc8n 7 месяцев назад

    How do we find the structure load on foundation

  • @pawanlalgupta6473
    @pawanlalgupta6473 3 года назад

    You have not told any yardstick to find angle theta... How to find density of soil.... How to find structure load..

  • @channabasava3739
    @channabasava3739 4 года назад +4

    how u decide angle of refose is 25....exactly how to find accurate angle of repose

    • @mostafizurrahman5940
      @mostafizurrahman5940 4 года назад

      by direct shear box test you can determine the angle of repose or friction.

    • @mdasharashraf8993
      @mdasharashraf8993 4 года назад

      How to do shear
      box text

    • @anishanishkt5284
      @anishanishkt5284 3 года назад

      Direct shear test send soil sample to any NABL civil lab, privet or PWD lab you can test

  • @ukkhan1000
    @ukkhan1000 4 года назад +3

    Sir how will know density of different soil wait for reply

    • @snailspeed4828
      @snailspeed4828 4 года назад

      You test the soil

    • @hugovanlawick8716
      @hugovanlawick8716 4 года назад +1

      Fill up a ten litre bucket with the soil and weigh. Then multiply the weight by 100. Or fill up a one litre water bottle with the soil and multiply by 1000. This will give you the weight per 1m3 ie the density.

  • @sunilprasad5731
    @sunilprasad5731 4 года назад +1

    What is meaning of bias

  • @ebenezeradukumaacquaah4349
    @ebenezeradukumaacquaah4349 3 года назад +1

    HELLO SIR. CAN THE ANGLE OF REPOSE BE DETERMINED WHEN THE SOIL IS TIPPED BY A TRUCK

    • @muhammadyasirsajid3886
      @muhammadyasirsajid3886 3 года назад

      yes brother u can determine the angle of repose from the soil tipped by a truck, in this case as the soil is disturbed and is not in its natural condition, so the sample which should be used in the test will be remoulded sample and the angle of friction/angle of repose will be less than the actual.

  • @fcenalia
    @fcenalia 3 года назад

    Internal friction is very important indicator of the soil and is found on triaxial cutting samples. Soil has only two indicators cohesion and internal friction... your explanation needs improvement

  • @bobroderick1881
    @bobroderick1881 2 года назад

    I’m not sure - does Rankins formula give you minimum depth of foundation? It wasn’t clear in this video.

  • @anishanishkt5284
    @anishanishkt5284 3 года назад +1

    Wich type of foundation in 6 story. raft, normal, single type of footing

    • @earlibee
      @earlibee 3 года назад

      it depends on soil type

  • @yamanappam3581
    @yamanappam3581 4 года назад

    Sir what are the types of methods to Find structure load / Building load???

  • @azamsiddique20071
    @azamsiddique20071 4 года назад

    Depth of foundation means thickness of rc foundation?

  • @HabiburRahman-xt2gl
    @HabiburRahman-xt2gl 4 года назад

    My dear, you have to work out completely for us to show the topic to understand clearly and have proved the viewers in basically well.

  • @hanyelnakira6851
    @hanyelnakira6851 4 года назад +2

    How is the situation in India for Muslims

  • @zabighouri2563
    @zabighouri2563 4 года назад

    How to find the structural load??

  • @johnlobby1509
    @johnlobby1509 4 года назад

    Salam How to find structural load
    How to find angle od ripos and densitu od soil
    There is threee question please explain it sir

    • @rasoolahamedshaik4551
      @rasoolahamedshaik4551 4 года назад +3

      By calculating the dead load and live load for a strctural building dead load u can calculate by self weight of members like beams columns and slab for live load we take as 1 kn /m2 for living area or inside home and 2 kn/m2 for stair case and bolcony 3kn/m2 for terras if needed or 1kn/m2 is enough...- BY this we can calculate the structural load of an building.

  • @mohideenmeeran4342
    @mohideenmeeran4342 4 года назад +1

    Sir, How will calculate p value.

    • @pdcetview
      @pdcetview 3 года назад

      Total load of specific column

  • @allpk.channel3052
    @allpk.channel3052 2 года назад

    Sir plz solve the problem 1.8 kg / cm2 ×m3/ 1600

  • @thomasedison1973
    @thomasedison1973 Месяц назад

    how to get P value?

  • @omarameen9753
    @omarameen9753 Год назад

    Can we use zero depth for raft foundation of a house?

  • @mohamedshoeb5436
    @mohamedshoeb5436 3 года назад

    Mai I know you are using Indian standard code book then please maintain it's code book number what ever it may be