A brief insight of an Domestic EICR (Electrical Installation Condition Report)
HTML-код
- Опубликовано: 21 авг 2024
- A brief example of an EICR being conducted , I haven't gone into too much detail for many reasons (1. this is not an instructional /training video 2. It will go on for too long 3. I have a monotone drone voice that will put you to sleep.)
The video is cut short as I was waffling on!
Sequence of tests:
*Safe isolation and dead testing
*Continuity of protective conductors, Inc MPBC and Supplementary bonding, continuity of Rings and Radial circuits
*Insulation resistance
*Live testing, Ze,Zs, polarity, PFC,RCD & Functional
*Disclaimer: This is not a instructional/ how to video. This is for entertainment purposes only and I do not claim to be a tutor.I highly recommend that you hire a registered electrician to carry out any electrical work.
💡💡💡Follow Burridge Electrical social media , your local electrician in Bristol , UK
Facebook : / burridgeelectrical
Insta : www.instagram....
Website : www.burridgeele...
💡💡💡
Burridge Electrical , Registered electrician in Bristol,UK.
#Burridgeelectrical #electrician #eicr #electricalinspections #bristol #localelectrician #landlordinspections #domesticelectrician #electricianUK #kingswood #electricaltesting #hanham #downend #staplehill #longwellgreen
Wow someone’s done a proper EICR for a change.👍 point of note the arethusa reading should be 1.76 times greater than the line and neutral. You did a good job there mate .👍
Thanks for the info!
Your voltage indicator is it a UNI-T ?
I think that one is a TIS 👍🏻 Fluke was my favourite voltage indicator