- Видео 36
- Просмотров 28 183
Burridge Electrical : Your local electrician
Добавлен 16 сен 2014
Electrician based in Bristol UK, #Localelectrician #trustedelectrician #burridgeelectrical #kingswood #bristol #stgeorge #hanham #staplehill #electrician #longwellgreen #downend #sparky #warmley #fishponds #brislington #bedminster #knowle #oldlandcommon #mangotsfield #speedwell #soundwell #emersonsgreen
1st fix of electrics on this 3 bed house rewire in St.George Bristol Day 2
1st fix of this house rewire in St.George Bristol.
#electrician #bristol #stgeorge #kingswood #burridgeelectrical #houserewire #house #rewire
Timestamp
0:00 1st fix walk around
0:30 upstairs
#electrician #bristol #stgeorge #kingswood #burridgeelectrical #houserewire #house #rewire
Timestamp
0:00 1st fix walk around
0:30 upstairs
Просмотров: 26
Видео
Replacing an inline bathroom fan
Просмотров 112Год назад
Replacing a failed inline bathroom fan. only information I was given was to replace the fan ,I have reccomended to the client to replace the ducting for new insulated duct ,so hopefully will be back to change it over
Wiring for a new kitchen knock through | Bristol Electrician | 1st fix
Просмотров 44Год назад
Installing new cabling for kitchen power and lighting, Inc an understairs WC. RFC for the kitchen sockets and a 10mm radial for the oven Hardly no chasing as the walls are going to be either dot &dabbed or batten and boarded , this is 1st fix only #bristol #electrician #hanham #kingswood #staplehill #downend #kitchenelectrics #rewiring Timestamp 0:00 Introduction 0:15 Socket and switch location...
customer changed their mind | Replacing socket plates | 2nd fix of a small kitchen extension
Просмотров 86Год назад
Replacing socket plates for customer supplied BG USB socket outlets and 45A cooker isolator. Carried out an alteration to this kitchen , added spot lights relocated the sockets and cooker power originally Installed In White click accessories but after the client changed his mind and ordered BG sockets. *Disclaimer: This is not a instructional/ how to video. This is for entertainment purposes on...
Annex building wiring | Bristol Electrician | Part one… First fix
Просмотров 177Год назад
wiring a newly built annex building at the bottom of a garden all 1st fix wiring going in . Part 1 Installation of power and lighting circuits for a small annex building in Bristol. Running cables through joists and to power locations. *Disclaimer: This is not a instructional/ how to video. This is for entertainment purposes only and I do not claim to be a tutor.I highly recommend that you hire...
Outside Light 💡| Customer had bought a Light fitting, is it any good?🤔 | Bristol Electrician
Просмотров 29Год назад
Installing a outside light that the Customer has supplied. We have installed various Luceco fittings over the years but haven't installed this model before, really simple to install ,there is no earth terminal for our cpc unfortunately, although it's a class 2 fitting we still have a protective conductor in the cable that needs terminating. what do you think of this light ? Has anyone else inst...
Making off SWA | Oven supply with SWA Cable | Bristol Electrician UK
Просмотров 50Год назад
Working with steel wire armour Cable (SWA) for an Oven supply . Original electric oven was spurred unfused of the kitchen ring circuit in 2.5mm T&E Which was under rated for the electric hob and oven. New Cable taken from the consumer unit to an 45A isolator for a new oven. *Disclaimer: This is not a instructional/ how to video. This is for entertainment purposes only and I do not claim to be a...
Office rip out | Commercial refurbishment
Просмотров 46Год назад
Removing power and lighting from an office /warehouse and put the building back to its original state prior to renting back out. *Disclaimer: This is not a instructional/ how to video. This is for entertainment purposes only and I do not claim to be a tutor.I highly recommend that you hire a registered electrician to carry out any electrical work. 💡💡💡Follow Burridge Electrical social media , yo...
Cables through a cavity wall | Simple one as it's a single storey building
Просмотров 9 тыс.Год назад
Cables through a cavity wall | Simple one as it's a single storey building
A brief insight of an Domestic EICR (Electrical Installation Condition Report)
Просмотров 326Год назад
A brief insight of an Domestic EICR (Electrical Installation Condition Report)
Pub rewire and renovation in Kingswood, Bristol.
Просмотров 71Год назад
Pub rewire and renovation in Kingswood, Bristol.
Charity work with Help Bristols Homeless | Your Local Electrician | Electrician in Bristol
Просмотров 32Год назад
Charity work with Help Bristols Homeless | Your Local Electrician | Electrician in Bristol
Commercial LED Lighting Installations and retro refits
Просмотров 222 года назад
Commercial LED Lighting Installations and retro refits
Your Local Electrician: House rewire in St.George in Bristol ,UK.
Просмотров 1412 года назад
Your Local Electrician: House rewire in St.George in Bristol ,UK.
A house getting Re-wired in Staple Hill, Bristol.
Просмотров 242 года назад
A house getting Re-wired in Staple Hill, Bristol.
House rewiring Electrician in Bristol,UK.
Просмотров 293 года назад
House rewiring Electrician in Bristol,UK.
How did you kno there was space there?
Your voltage indicator is it a UNI-T ?
I think that one is a TIS 👍🏻 Fluke was my favourite voltage indicator
Wow someone’s done a proper EICR for a change.👍 point of note the arethusa reading should be 1.76 times greater than the line and neutral. You did a good job there mate .👍
Thanks for the info!
nice job
Hi Did you say 25mm sub main ? Why so big ? Thanks
Alright , 25mm cable ran in due to the long run from the front of the house where the origin is down to the bottom of the garden , the annex had electric heating , electric water heater , shower , sockets and lighting so by calculation of cable length , load and VD the CSA come in at 25mm
@@burridgeelectricalyourloca2075 you know you’re onions….tell me can you have another metre in the annex
Exellent
Thanks
Bezpiecznik powinien być zmieniony na odpowiedni do przekroju przewodu
Yes your correct, this cable is 1.5mm flex rated at 16A current ,so the 13A fuse is suitable 😉
@@burridgeelectricalyourloca2075 ciekawe W Polsce 1,5mm jest na max 10A
@@Kosmakozyra dzien dobry, that is interesting mate , in the UK the BS7671 wiring regulations we work to shows that 1.5mm is rated for 16A and less depending on installation methods etc
Fact I'm married to a plasterer #1 messiest, laziest, not pickin. Up after himself EVER onthis PLANET PLASTERS are the messiest Make No Mistake
It is a messy job I must admit , however the plasterers I know normally tidy up ,but this is a right mess 🤣
@@burridgeelectricalyourloca2075 understand lol
I wire up robots for my robotics team. This is when mechanical tries wiring moving parts and doesn't leave slack for the dammed thing to move.
anton burridge, hello. Is it possible to get a job for me in UK as a foreign citizen? I have a plastering, drywall, painting and electrician skills.