    @vikramvarma475 5 дней назад

    It's kinda like a capacitor added in parallel to an AC to DC converter outp5

  • @TOAOZuur
    @TOAOZuur 2 года назад +2

    Very good point at 04:30 Things that break are indeed a safety problem. Recently I've seen some bad examples. One of them was a chemical dosing pump that was placed on top of a small storage tank. No plexi glass, no leak detection, and I assume also no pulsation dampener. Despite my warnings of possible line breakage and my advice of buying and installing a propper chemical dosing unit (a skit mounted unit with all the safety devices on board) the company continued to operate with this makeshift installation. Visiting the the location again a few weeks later I noticed a very bad smell of bleach / chlorine. I was told that the dosing line broke and that the pump continued to spray Sodium Chlorite (a poisonous and corrosive chemical substance) during the weekend.

  • @mudpump
    @mudpump 10 месяцев назад +1

    supply mud pump parts❤❤

  • @marcosortolani3639
    @marcosortolani3639 11 месяцев назад +1

    Thanks for the class! I am rebuilding a Fuel Pressure Regulator, from the fuel circuit of an old Mercedes, which works at 2bar. What materials can I use to make the diaphragm?

  • @statictrance7798
    @statictrance7798 2 года назад +1

    Bedankt voor de uitleg! Zo’n compensator is precies wat geadviseerd kan worden voor een tunnel gemaal!
    De tunnel pomp’s leidingwerk is gerenoveerd naar PE materieel, en als de pomp stopt is er een enorme waterslag waardoor tot zover ook de muurdoorvoer hechting is gescheurd door de kracht!

  • @성도현-r4i
    @성도현-r4i Месяц назад

    Wow

  • @CodyFelts-dy8oj
    @CodyFelts-dy8oj 5 месяцев назад

    Great video
    I got two weatherford F-1300 mud pumps on a drilling rig. I drill with around 2000 psi.
    The pulsation dampeners are both pressured up to 3200 psi.
    What should pressure be on dampeners and what is it doing to my mud pump because the pressure is so high?
    Thanks……

  • @pedrobaldo2045
    @pedrobaldo2045 Год назад

    The animation is pretty good, but it doesn't explain why the liquid wouldn't retreat into the upstream line when the dampner is on its return cycle. This needs to be adjusted, or if a check valve is used upstream of the flow (which I guess is the answer !!), it needs to be stated. Thought some pulsation dampners might actually be fitted with a "mitre valve" on the receiving opening to stop this flow reversal when the pump momentarily stops.

  • @metlgandalf
    @metlgandalf Год назад

    Thanks for the Informative Video. Could you please answer me what size of Pulsationdämpfer i need for a Maximum flowrate of 4000l/h? And what size for lets say 15000 l/h? Need that for a Hosepump. The output needs to be steady and smooth. smooth

  • @shimxininahi8024
    @shimxininahi8024 Год назад

    Toyota uses a ignition damper on the fuel rail to soften the displacement of High and low pressures. I earned something new. My home water regulator makes loud fluttering noise so I wonder if its time to change it? Thank you!

  • @muhammadobaidullahhashmi4334
    @muhammadobaidullahhashmi4334 Год назад

    What about a pressure gauge on a dampner...
    I have two identical pumps pumping same fluid into two different systems ..their individuL PGs same pressure...but on dampner PG one is showing the pressure equal to discharge and on other there is no pressure...what does it means

    • @desmondofere988
      @desmondofere988 Год назад +1

      It has to be set 70% of discharge pressure