The brazing itself smells slightly of acetylene which is hardly noticeable. The phosgene gas that will be produced if theres any refrigerant left in the line youre heating on the other hand will mess your day up
I have this same machine at my building, I’m having problems with the water not coming through the water distribution tray evenly, and all it does is make streaks of ice and it freezes to my ice probe, what causes that?
Sounds like low water flow from a clogged pump inlet or distributor and it needs cleaning. Could also be the problem this one had with a slow water fill.
@@satanicinduction I checked the pump no build up or anything to restrict the water flow. Came in this morning massive sheet of ice on grid and probe had to take my heat gun to melt it.
Multiple problems? It seems like it cant harvest properly which isnt necessarily related to the uneven water distribution. Have you removed the water distributor and seen that its clear? No bent pieces in the grid? What about calcium build up making the ice stick?
Como supistes que era el panel eléctrico? Porque tengo una que tira el agua pero no ase yello esta continuamente corriendo el agua todo lo demás seve que sirve pero tira agua a si como tu vídeo??
En esta máquina el problema no era eléctrico. Probé el voltaje para asegurarme de que la válvula no funcionaba correctamente. Esta válvula que falla de esta manera a veces se congelará y será difícil de atrapar.
T3 shows the evaporator inlet temp which is affected by the harvest valve. When it shot back down it showed that hot gas had stopped flowing from the harvest valve.
Creo que tendrías que usar una aplicación de traducción de audio para traducir lo que digo al español. No sé cómo poner subtítulos en español en mis videos.
Thank you, I am a layman in the field of refrigeration technician. Watching your video now I get insight
Aye aye cap'n
This is the reason I watch this channel. #htine #holditdine
I can dig it
I'll assume you changed the filter dryer too but just didn't show that part.
Yea that parts just implied
Very nice repair, how does the braising smell indoors?
The brazing itself smells slightly of acetylene which is hardly noticeable. The phosgene gas that will be produced if theres any refrigerant left in the line youre heating on the other hand will mess your day up
Nice diagnostic and repair. When I change those harvest valves I silver solder, don’t need much, just sucks right into that lip.
I've yet to try it that way, but if i did, I'd use too much for principal
@@satanicinduction I get it lol. It was cool finding this channel cause I work on all the same shit you do, hot side to cold side.
You the man! Good job.
Thank you
Which number nozzle using for your torch I like that flam😮
Uniweld, #2 tip, 5psi gas, oxy matched by sound
It needed to be cleaned in this video
I have this same machine at my building, I’m having problems with the water not coming through the water distribution tray evenly, and all it does is make streaks of ice and it freezes to my ice probe, what causes that?
Sounds like low water flow from a clogged pump inlet or distributor and it needs cleaning. Could also be the problem this one had with a slow water fill.
@@satanicinduction I checked the pump no build up or anything to restrict the water flow. Came in this morning massive sheet of ice on grid and probe had to take my heat gun to melt it.
Multiple problems?
It seems like it cant harvest properly which isnt necessarily related to the uneven water distribution.
Have you removed the water distributor and seen that its clear? No bent pieces in the grid? What about calcium build up making the ice stick?
I also tried to replace it, but why is the machine still freezes up?
Perhaps the harvest valve was not the problem
Como supistes que era el panel eléctrico? Porque tengo una que tira el agua pero no ase yello esta continuamente corriendo el agua todo lo demás seve que sirve pero tira agua a si como tu vídeo??
En esta máquina el problema no era eléctrico. Probé el voltaje para asegurarme de que la válvula no funcionaba correctamente. Esta válvula que falla de esta manera a veces se congelará y será difícil de atrapar.
Make or buy a recovery coil, really speeds it up. I made a couple when we had to reclaim 100 pounds, wish I would’ve made it sooner.
If i had to do 100lb recovery i would definately want one
Check the HPR valve and pressure on low side during harvest
I just don't think I'll ever be doing that
T3 Harvest valve was replaced?
T3 shows the evaporator inlet temp which is affected by the harvest valve. When it shot back down it showed that hot gas had stopped flowing from the harvest valve.
Buenas a todos.. como puedo encontrar este video en español? Porfavor
Creo que tendrías que usar una aplicación de traducción de audio para traducir lo que digo al español. No sé cómo poner subtítulos en español en mis videos.
Cómo puedo comprar una navaja como la tuya de MANITOWOC
No sé si alguna vez encontraré otro. Este fue un sorteo aleatorio en una clase de capacitación. Al buscar uno en línea, no encontré ninguno.
nice trouble shooting,scales are for beginners.
Thats right