How to diagnose, replace diverted, valve pressure sensor, auto air vent on Vaillant boiler

Поделиться
HTML-код
  • Опубликовано: 8 фев 2024
  • How to diagnose / replace /diverted valve / pressure sensor (F75) / auto air vent/ on a single boiler, Vaillant Eco tec boiler step by step
    This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions.
    Before to start any work on gas appliance isolate the power, turn off the gas and the waters.
    Diverted valve is leaking, it's built up limescale on auto air vent and pressure sensor
    Download manual
    www.vaillant.co.uk/downloads/...
    2. Remove front cover
    3. Isolate the flow and return valves
    4. Drain the boiler
    5. Leave open the drain point
    6. Remove air inlet pipe
    7. Remove pressure sensor and replace for new one
    8. Remove and replace auto air vent
    9. Remove and replace pressure sensor
    10. Close the drain valve and open the flow and return valves
    11. Re-pressurise the heating system till 1 - 1.5 bar.
    If you need more information you can find on my channel each part replacement individual.