Fluctuating / jumping temperature on Vaillant boiler / How to replace PCB / Motherboard step by step
Fluctuating / jumping temperature on Vaillant boiler / How to replace Printed Circuit Board / Motherboard step by step
This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions.
Before to start any work on gas appliance isolate the power, turn off the gas and the waters.
1. Download manual
professional.vaillant.co.uk/downloads/product-manuals/ecotec-plus-1/ecotec-plus-combi-and-system-installation-instructions-2422739.pdf
2. Remove front cover
3. Remove PCB cover
4. Disconnect cables
5. Replace PCB
6. Reconnect cables
7. Test it
Просмотров: 173

Видео

How to remove, refit condensate trap on Worcester 8000 series boiler step by step
Просмотров 152Месяц назад
How to remove, refit condensate trap on Worcester 8000 series boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. 1. Download manual www.worcester-bosch.co.uk/professional/support/literature/greenstar-8000-life-system-installation-and-maintenance-inst...
How to replace diverter valve . Leaking diverter valve on Baxi Duo Tec / Potterton Promax
Просмотров 993Месяц назад
How to replace diverter valve / 3 way valve assembly. Leaking diverter valve on Baxi Duo Tec / Potterton Promax boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Leaking diverter valve 1. Download manual www.wolseley.co.uk/wcsstore/ExtendedSitesCata...
How to replace diverter valve cartridge / Leaking diverter valve on Glow Worm Energy boiler
Просмотров 5842 месяца назад
How to replace diverter valve cartridge / Leaking diverter valve on Glow Worm boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Pressure sensor is faulty because there is 1.5bar pressure on the boiler and the boiler is giving F75 fault code 1. Downl...
F2 Fault / Flame loss / How to replace gas valve on an Ideal Logic boiler step by step
Просмотров 1,3 тыс.2 месяца назад
F2 Fault / Flame loss / How to replace gas valve on an Ideal Logic boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. 1. Remove front cover 2. Download manual idealheating.com/uploads/documents/logic-2-combi-installation-servicing.pdf 3. Isolate gas ...
Fault E160 on Potterton / Baxi / Main boiler / How to replace Fan Assembly step by step
Просмотров 1,2 тыс.2 месяца назад
This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Fan is faulty because the fan have 220V but is not comming on. 1. Download manual www.wolseley.co.uk/wcsstore/ExtendedSitesCatalogAssetStore/images/products/AssetPush/DTP_AssetPushHighRes/std.lang.all/ti/on/Potterton_Pr...
How to replace circulating pump head on an Ideal Logic boiler step by step
Просмотров 5863 месяца назад
This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. 1. Remove front cover 2. Download manual idealheating.com/uploads/documents/logic-2-combi-installation-servicing.pdf 3. Drain the boiler 4. Remove the circulating pump screws. 5. Replace circulating pump head. 6. Refit ...
How to diagnose, replace diverted, valve pressure sensor, auto air vent on Vaillant boiler
Просмотров 2,2 тыс.3 месяца назад
How to diagnose / replace /diverted valve / pressure sensor (F75) / auto air vent/ on a single boiler, Vaillant Eco tec boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Diverted valve is leaking, it's built up limescale on auto air vent and pressur...
How to clean, remove / refit condensate trap Worcester SI combi boiler step by step
Просмотров 9903 месяца назад
How to clean, remove / refit condensate trap Worcester SI combi boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. 1. Download manual www.worcester-bosch.co.uk/professional/support/literature/greenstar-si-compact-combi-installation-instructions 2. Re...
How to replace expansion pipe (vessel) on water side for a Viessman Vitodens 100 boiler step by step
Просмотров 2983 месяца назад
How to replace expansion pipe (vessel) on water side for a Viessman boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Expansion pipe (vessel) is leaking 1. Download manual viessmanndirect.co.uk/files//f4fb553c-3bed-4675-b4f7-a9d1010f8b98/1706 Vitode...
How to replace diverter valve on a Vaillant Eco tec boiler step by step
Просмотров 10 тыс.4 месяца назад
How to replace diverter valve on a Vaillant Eco tec boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Dripping diverter valve 1. Download manual www.vaillant.co.uk/downloads/z/ecotec/ecotec-installation-servicing-2007-372783.pdf 2. Remove front cove...
How to diagnose, replace pressure sensor, F75 with pressure on a Vaillant Eco boiler step by step
Просмотров 2,3 тыс.4 месяца назад
How to diagnose / replace pressure sensor / F75 with good pressure / on a Vaillant Eco tec boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. Pressure sensor is faulty because there is 1.5bar pressure on the boiler and the boiler is giving F75 fault ...
How to diagnose / replace auto air vent (AAV) on a Vaillant Eco tec boiler step by step
Просмотров 1,5 тыс.4 месяца назад
How to diagnose failed auto air vent (AAV) and how to replace expansion vessel on a Vaillant Eco tec boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. 1. Remove front cover 2. Download manual www.vaillant.co.uk/downloads/z/ecotec/ecotec-installation...
How to diagnose / replace expansion vessel on a Vaillant Eco tec boiler step by step
Просмотров 1,3 тыс.4 месяца назад
How to diagnose failed expansion vessel and how to replace expansion vessel on a Vaillant Eco tec boiler step by step This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions. Before to start any work on gas appliance isolate the power, turn off the gas and the waters. 1. Remove front cover 2. Download manual www.vaillant.co.uk/downloads/z/ecotec/ecotec-installation-se...
How to top up / re pressurise Worcester combi boiler with built in keyless filling loop
Просмотров 8435 месяцев назад
1. Check the pressure on you boiler (normal pressure is between 1-1.5 bar), if the pressure drops below 1 then has to be re ressurise. 2. If the pressure is below 1.5 bar, you can top up by using the filling loop, in this case is an internal filling loop with blue leaver. You have to pull the blue leaver and hold pulling until the pressure reach 1.5 bar. 3. After the pressure reached 1.5 bar yo...
How to re-pressurising expansion vessel on a Vaillant Eco tec boiler step by step
Просмотров 2456 месяцев назад
How to re-pressurising expansion vessel on a Vaillant Eco tec boiler step by step
How to re-pressurising expansion vessel on a Vokera combi boiler step by step
Просмотров 9616 месяцев назад
How to re-pressurising expansion vessel on a Vokera combi boiler step by step
How to re-pressurising expansion vessel on a Baxi Dou Tec combi boiler step by step
Просмотров 9026 месяцев назад
How to re-pressurising expansion vessel on a Baxi Dou Tec combi boiler step by step
How to re-pressurising expansion vessel on an Ideal Logic boiler step by step
Просмотров 2,1 тыс.6 месяцев назад
How to re-pressurising expansion vessel on an Ideal Logic boiler step by step
How to clean, remove / refit condensate trap Ideal Logic boiler step by step
Просмотров 3,7 тыс.7 месяцев назад
How to clean, remove / refit condensate trap Ideal Logic boiler step by step
Fault F22, Low Water Pressure on Vaillant, How to fill up / top up water pressure
Просмотров 2998 месяцев назад
Fault F22, Low Water Pressure on Vaillant, How to fill up / top up water pressure
How to check water pressure on Vaillant eco TEC plus 826
Просмотров 7448 месяцев назад
How to check water pressure on Vaillant eco TEC plus 826
How to replace PRV on Baxi boiler
Просмотров 3,2 тыс.8 месяцев назад
How to replace PRV on Baxi boiler
How to check pressure on Intergas combi boiler
Просмотров 2,1 тыс.8 месяцев назад
How to check pressure on Intergas combi boiler
How to set water temperature for the radiators and the hot water
Просмотров 678 месяцев назад
How to set water temperature for the radiators and the hot water
Black Display with power on, Baxi 800 / How to replace fuse in the Baxi boiler
Просмотров 2,3 тыс.10 месяцев назад
Black Display with power on, Baxi 800 / How to replace fuse in the Baxi boiler
How To Top Up The Pressure / Repressurise On Your Viessmann Vitodens Combi Boiler
Просмотров 4 тыс.Год назад
How To Top Up The Pressure / Repressurise On Your Viessmann Vitodens Combi Boiler
F75 Fault code. Low Water Pressure on Vaillant combi boiler / How to add pressure, repressurise it.
Просмотров 4,9 тыс.Год назад
F75 Fault code. Low Water Pressure on Vaillant combi boiler / How to add pressure, repressurise it.
E 118 Fault, Low system pressure. How to top up / Repressurise Baxi EcoBlue Advance Combi Boiler
Просмотров 4,1 тыс.Год назад
E 118 Fault, Low system pressure. How to top up / Repressurise Baxi EcoBlue Advance Combi Boiler
How To Top Up The Pressure / Repressurise On Your Worcester Combi Boiler
Просмотров 1,5 тыс.Год назад
How To Top Up The Pressure / Repressurise On Your Worcester Combi Boiler

Комментарии

  • @shiningstone9451
    @shiningstone9451 Час назад

    The water circulation pump in my Navien NCB 180E has been making a terrible, loud noise for two days. Thank you very much for you video that could be the solution I'm looking for!!!

  • @nogbadthebad2609
    @nogbadthebad2609 2 дня назад

    Very clear and concise, thank you

  • @mufasamufufu-rj6ti
    @mufasamufufu-rj6ti 2 дня назад

    Man, those muslims brought the sand with them

  • @kamaldahal4672
    @kamaldahal4672 2 дня назад

    Thank you

  • @kamaldahal4672
    @kamaldahal4672 3 дня назад

    Nice video but if you explain bit on issues and how to rectify would be more helpful to learn, tks

    • @balintistvan1551
      @balintistvan1551 3 дня назад

      You can diagnosis easy, if you turn on the heating wait approximately 5-10 min and check the boiler display. The heating will come in and it’s gonna show a temperature and it will jump on higher temperature and then back to lower temperature. This will indicate you have a PCB fault.

  • @paulrossiter9567
    @paulrossiter9567 11 дней назад

    You should use the monument spanner 🔧 22 - 15 mm nuts 🤩

  • @davecavaghan7889
    @davecavaghan7889 12 дней назад

    why didn’t you source a compatible cartridge for the boiler model/ serial number

    • @bheating
      @bheating 12 дней назад

      For diverter valve with bypass there is no cartridge replacement awalaible.

  • @2009bager
    @2009bager 20 дней назад

    Just replace the cartridge and happy days

    • @bheating
      @bheating 19 дней назад

      The cartridge is not compatible for this type of diverted valve because it's with bypass pipe. www.screwfix.com/p/baxi-7656807-erp-models-3-way-valve-cartridge-without-by-pass-only/291TP?tc=ET6&gad_source=1&gclid=Cj0KCQjw8pKxBhD_ARIsAPrG45na_KR8zPgnN0dwE6cROfAMfpBTLR-C7h6Ky5MeGB-MVvrTYis8XB4aAnizEALw_wcB&gclsrc=aw.ds

  • @MickeyBlue-eyes
    @MickeyBlue-eyes 25 дней назад

    Worcester boilers 🤦🏻‍♂️

  • @10tomwilliams
    @10tomwilliams Месяц назад

    Shouldn’t be putting this kind of content on youtube. Encouraging diy repairs and not good for our industry. Shame on you. Anyone can stick a camera on while they do a job. Its lazy thoughtless content.

  • @bluedwarf8858
    @bluedwarf8858 Месяц назад

    Just wondering why you took the whole block out, i thought you could unscrew the top of the diverter valve and screw in a new one. Im no expert its just what ive seen being done on other channels

    • @bheating
      @bheating Месяц назад

      The cartridge is not compatible with the tree port valve with bypass pipe. www.screwfix.com/p/baxi-7656807-erp-models-3-way-valve-cartridge-without-by-pass-only/291TP?tc=ET6&gad_source=1&gclid=Cj0KCQjw8pKxBhD_ARIsAPrG45na_KR8zPgnN0dwE6cROfAMfpBTLR-C7h6Ky5MeGB-MVvrTYis8XB4aAnizEALw_wcB&gclsrc=aw.ds

    • @bluedwarf8858
      @bluedwarf8858 Месяц назад

      @@bheating ah OK got you, thanks

    • @leebuchanan8194
      @leebuchanan8194 26 дней назад

      Plus if its snapped you change entire lot anyways,unless you can fish bits out

  • @paulbentley849
    @paulbentley849 Месяц назад

    My expansion vessel label say precharge is 0,75 +0,2 bar can u help me the pre-charge expansion vessel pressure

  • @paulbentley849
    @paulbentley849 Месяц назад

    U didn't close the flow and return valves

    • @bheating
      @bheating Месяц назад

      Yes, I didn't isolated because the boiler was on top floor the highes point of the heating system.

    • @ashleybone342
      @ashleybone342 Месяц назад

      So if you had had to do that, is it the 2 black valves on opposite ends of boiler to isolate them?

    • @bheating
      @bheating Месяц назад

      @@ashleybone342 Yes

  • @martmk-zj5vz
    @martmk-zj5vz Месяц назад

    Wher I can find the fan nr ?

    • @bheating
      @bheating Месяц назад

      You can dowload the manual and there you can find it. www.wolseley.co.uk/wcsstore/ExtendedSitesCatalogAssetStore/images/products/AssetPush/DTP_AssetPushHighRes/std.lang.all/ti/on/Potterton_Promax_Combi_Installation.pdf Mine was Fan 5121447

    • @bheating
      @bheating Месяц назад

      This Video is fo GAS SAFE engineers, for gas user it's not permited for user to replace parts, not even to remove the boiler front cover!!!!!!

  • @predragsinko2513
    @predragsinko2513 Месяц назад

    Don't have a loop.

  • @raiden8502
    @raiden8502 2 месяца назад

    'Promo sm'

  • @dannymatona3506
    @dannymatona3506 2 месяца назад

    Nice one.

  • @valentinavioletamihai3160
    @valentinavioletamihai3160 2 месяца назад

    I don't have those 🙄 !

    • @bheating
      @bheating 2 месяца назад

      Most probaly then you have an external filling loop. www.google.com/search?q=external+filling+loop&rlz=1C1CHBD_en-GBGB830GB830&oq=exter&gs_lcrp=EgZjaHJvbWUqDAgCECMYJxiABBiKBTIGCAAQRRg5MgoIARAuGLEDGIAEMgwIAhAjGCcYgAQYigUyBwgDEAAYgAQyCggEEAAYsQMYgAQyCggFEAAYsQMYgAQyCggGEAAYsQMYgAQyCggHEAAYsQMYgAQyBwgIEAAYgAQyBwgJEAAYjwLSAQg0MjA1ajBqN6gCALACAA&sourceid=chrome&ie=UTF-8

    • @predragsinko2513
      @predragsinko2513 Месяц назад

      Dont have a loop. 😢

    • @bheating
      @bheating Месяц назад

      Most probaly then you have an external filling loop. www.google.com/search?q=external+filling+loop&rlz=1C1CHBD_en-GBGB830GB830&oq=exter&gs_lcrp=EgZjaHJvbWUqDAgCECMYJxiABBiKBTIGCAAQRRg5MgoIARAuGLEDGIAEMgwIAhAjGCcYgAQYigUyBwgDEAAYgAQyCggEEAAYsQMYgAQyCggFEAAYsQMYgAQyCggGEAAYsQMYgAQyCggHEAAYsQMYgAQyBwgIEAAYgAQyBwgJEAAYjwLSAQg0MjA1ajBqN6gCALACAA&sourceid=chrome&ie=UTF-8

  • @gaunerchen1729
    @gaunerchen1729 3 месяца назад

    What type of gloves are you using? Do you recommend them?

    • @bheating
      @bheating 3 месяца назад

      www.screwfix.com/p/site-sdg230-nitrile-powder-free-disposable-chemical-gloves-blue-medium-100-pack/792RR?tc=ET6&gad_source=1&gclid=CjwKCAiA3JCvBhA8EiwA4kujZnoCDrvRJtLLZoPehbZJmc7rLZTz8YHng6sAs4RmjChSQzo74DBdhRoC8uEQAvD_BwE&gclsrc=aw.ds They are good.

    • @gaunerchen1729
      @gaunerchen1729 3 месяца назад

      @@bheating Thanks!

  • @darrengosling3477
    @darrengosling3477 3 месяца назад

    Much appreciated, great explanation

  • @nazarnazar8604
    @nazarnazar8604 3 месяца назад

    🫶🏻🫶🏻🫶🏻

  • @sharoncoombs6895
    @sharoncoombs6895 3 месяца назад

    Thanks for that. It saved me calling out a plumber 🙏🏾

  • @Doubledex123
    @Doubledex123 3 месяца назад

    Got my first job doing this in a couple of hours. Will have this video as a walk through. Thanks!

  • @THELONDONCHANNEL
    @THELONDONCHANNEL 3 месяца назад

    🫡

  • @BoilerServiceandRepair
    @BoilerServiceandRepair 3 месяца назад

    So if the expansion was flat then the air in the radiators would of been hiding the issue and acting like an expansion vessle. Loads to learn in this trade

  • @navidrajaei7215
    @navidrajaei7215 3 месяца назад

    Thanks for sharing your experience 👍

  • @linwoodeaton2907
    @linwoodeaton2907 3 месяца назад

    😝 'Promo sm'

  • @navidrajaei7215
    @navidrajaei7215 3 месяца назад

    appreciate for sharing your experience

  • @Razz60
    @Razz60 3 месяца назад

    Brilliant video thanks

  • @BoilerServiceandRepair
    @BoilerServiceandRepair 3 месяца назад

    That's just masking the problem. Should really recharge the expansion vessle and test the valve. Then check the tun dish after 👍

    • @bheating
      @bheating 3 месяца назад

      That is true, but that boiler lost the pressure after the customer bled the radiators.

  • @Grassislong
    @Grassislong 3 месяца назад

    Hi quick question - why did you need to dispose of the water? is it not connected to a plastic exit pipe?

    • @bheating
      @bheating 3 месяца назад

      You have to clean the condense trap to not build up sediment because it can block it and then the boiler will stop working. Yes, it's connected to condensate pipe.

  • @jamesd755
    @jamesd755 3 месяца назад

    I bought a 250mm Pz2 with magnetic tip purely for that bottom screw ☺️

  • @snagright1300
    @snagright1300 3 месяца назад

    Great Video bro - Grab a 8mm ratchet spanner - great for them vaillant drain offs!

  • @user-li8gr8ur8l
    @user-li8gr8ur8l 3 месяца назад

    Clear video no speeding. ❤

  • @Razz60
    @Razz60 4 месяца назад

    Brilliant video thanks

  • @Razz60
    @Razz60 4 месяца назад

    Would you recommend to put in a new fibre washer on retun valve connection?

    • @bheating
      @bheating 4 месяца назад

      I use to use always the manufacturer one which is coming with the new part.

    • @barrydoherty636
      @barrydoherty636 4 месяца назад

      Great video, well done.

    • @Razz60
      @Razz60 3 месяца назад

      Thanks to your video i did my 1st diverter valve i cant thank you enough thanks for upload

    • @bheating
      @bheating 3 месяца назад

      You're welcome@@Razz60

  • @orhan2674
    @orhan2674 4 месяца назад

    Thank you for your effort and sharing...

    • @bheating
      @bheating 4 месяца назад

      Always welcome

  • @uraveragerifler2901
    @uraveragerifler2901 4 месяца назад

    Don’t really have the blue taps, basically no filling loops. Only the black ones. What now?

    • @bheating
      @bheating 4 месяца назад

      Please send a picture from the pipes and valves under the boiler and I will try to help you.

    • @uraveragerifler2901
      @uraveragerifler2901 4 месяца назад

      @@bheating all good now mate, i fixed it. Cheers!

    • @bheating
      @bheating 4 месяца назад

      You're welcome@@uraveragerifler2901

    • @keirseymour4523
      @keirseymour4523 4 месяца назад

      Hi mate same issue here. Here's a picture

    • @keirseymour4523
      @keirseymour4523 4 месяца назад

      Not sure how to send a picture actually but just black ones and one yellow one

  • @martinellimunshi2622
    @martinellimunshi2622 5 месяцев назад

    Should the condensator trap be refilled with water prior to putting it back in? I just followed this video and didnt refill it. However, other videos say you have to refill it. Please can you confirm? Thanks!

    • @bheating
      @bheating 5 месяцев назад

      Either way is good.

  • @yensabi
    @yensabi 6 месяцев назад

    Nice one.... Is the sensor the same as a Vaillant sensor and can you interchange them...?

    • @bheating
      @bheating 6 месяцев назад

      Yes, it's same as the Vaillant one

  • @lynhamilton3762
    @lynhamilton3762 6 месяцев назад

    Fantastic easy to understand simple video. Cheers

    • @bheating
      @bheating 6 месяцев назад

      Glad it was helpful!

  • @BALDYDAVE1957
    @BALDYDAVE1957 6 месяцев назад

    following theses simple instructions my boiler is now up and running....big thank you

    • @bheating
      @bheating 6 месяцев назад

      You're welcome!

  • @sajidmah62
    @sajidmah62 7 месяцев назад

    Need bit long video

    • @bheating
      @bheating 7 месяцев назад

      I can't make now longer video because I have to met again the same problem with a same boiler. I can give you a bit longer description to can replace step by step. 1 Isolate Flow and Return (black leavers on video) 2 Drain the system by openinf drain valve located in the boiler (white drain valve) 3 Remove the nut from PRV 4 Remove the screw which is holding the PRV (with an Allan key) 5 Pull out the PRV Now you have to do the same tings in reverse order and by the end you have to fill up the system and test it. Don't forget to follow the manufacturer instructions. Page 54. mediacdn.baxi.co.uk/-/media/websites/baxiuk/files/product-literature/baxi-megaflo-system/baxi_megaflo_system_installation_and_service_manual.pdf?v=1&d=20230824T154719Z

    • @sajidmah62
      @sajidmah62 7 месяцев назад

      @@bheating thankyou so much 👍