Pressure Cut Out in Refrigeration,
High & Low Pressure Cut Out Adjustment
Pressure Cut Out in Refrigeration,
pressure Cut Out Switch,
pressure Cut Out Switch in refrigerator,
high pressure Cut Out Switch,
high pressure Cut Out,
low pressure Cut Out,
low pressure Cut Out Switch,
high pressure Cut Out in Refrigeration,
low pressure Cut Out in Refrigeration,
pressure Cut Out adjustment,
low pressure Cut Out adjustment,
high pressure Cut Out adjustment,
how pressure cut out works,
pressure Cut Out working principles,
pressure Cut Out problems,
pressure Cut Out troubleshooting,
how to repair pressure Cut Out,
pressure Cut Out replacement,
Some Important video Links...
Compressor Voltage and Speed relationship || Effect of voltage on RPM.
• Video
How to repair old refrigerator || How to check compressor pressure || Flushing condenser with R-12
• Video
Inverter AC removing & Re-installation complete video.
• Inverter AC removing &...
AC Sensor checking || Sensor working principle
• AC Sensor Testing || ...
FK mech official,
FK,
FK mech,
FK mach,
FK mech official RUclips channel,
Instructor Farman Khan,
basics of refrigeration,
Thanks Dear for watching this video, please don't forget to subscribe my RUclips channel
'FK mech official'
Very nice teacher
Thanks
Thank you. This is one of my favorite refrigeration channels. You have very good experiments.
Thanks Dear for appreciate me 💗
Is Soch ko LP op switch ko direct kaise karen
Brother, isss me wire series me supply hwa hota hai, so ap wire IN awr wire OUT ko apas me short kar den. Direct ho jaye ga
Oil charj karne per compressor trip ho raha hai
@@FKmechofficial thanks bro
@@SHEKHARSINGH-j9q Shukarya Bhai ❤️
This is hands down the best channel. The way you teach and explain is fantastic. thank you very much. Wish you 100k subscribers very soon :)
Thanks Dear for your valuable comments, Insha Allah soon I will achieve your best wishes for me
sir, good job , nicely explained for HP & LP cut out set points
have been waty so many videos for refrigeration , but no one explained like this.
my question is split acs dont have any pressure cutouts why
Thanks Dear brother for your valuable comments 💞,
Answer of your question is cut outs are not used in split ACs because in split AC the quantity of refrigerant is quite lower than commercial & industrial HVAC units,
Split ACs (about 1 TOR to 4 TOR) operates with maximum 1 kg refrigerant to 4 kg refrigerant, which is not so much danger as like industrial or commercial HVAC units which operates with refrigerant about 30 kg to 50 kg, and that's why these units are very dangerous if refrigerant pressure goes high in condenser,
Any way in split ACs the sensors or compressor is used with overload protector so as the pressure will be high, the current will be high & compressor will stop working so the pressure will remain in control limit,..
I hope you will understand now,
Thank you ❤️
Very nice
Good job sir keep up good work .
Thanks Dear Sir Yasir SB ❤️
nicely explained .
where can i find videos related to Airconditioning Testing Lab as in R&D facilities of MNC Working .
Can you suggest something in this reference
R&D means, ??
MNC ???
@@FKmechofficial Research and Development (R&D)
MNC (Multi National Company).
@@anshumansah3439 ohhh that's good, you can try in different companies in Canada, America, Australia
Mashallah, bahut important information hai
Thanks Dear brother ❤️
Sir you are doing a really great Job thanks for being there for us love and respect from karachi
Thanks Dear brother ❤️
10ft chiller freezer container p unit nhi chal raha tha.jb low pressure switch denfoss ki cable ko direct kiya.tb unit chalo hua.full night running p raha.subah running p tha.9 baze fir se same unit off hogya compressor fan.sirf sub zero p temperature show karta h.or compressor ka simble blinking hota h.
Thermostat se OFF ho chuka hoga,
Low pressure se direct nhi karna chahye,
Balke uss ki adjustment karden bhai !!! ❣️
Sub zero laga h.avi pehle jaisa tha same waisa hi kiya.low pressure switch ko connection diya.lekin avi chalo nhi hota h.sub zero m temperature plus ➕ show karta h. -20 zarurat..avi standing pressure 35 psi h.or discharge pressure 150psi
Sub zero laga h.avi pehle jaisa tha same waisa hi kiya.low pressure switch ko connection diya.lekin avi chalo nhi hota h.sub zero m temperature plus ➕ show karta h. -20 zarurat..avi standing pressure 35 psi h.or discharge pressure 150psi
@@shaikhsabir3828 03059126576
Mere WhatsApp pe pressure cut out ki picture awr Suction pressure discharge send karden ❤️
@@shaikhsabir3828 +92 3059126576
ماشاءاللّٰه
Thanks Dear brother ❤️
You are great ustad
Thanks Dear brother for your valuable comments ❤️
nice
Thanks
❤
Thanks Dear brother ❤️❤️
Hello sir r410 ka suction pressure 200 psi haii amp normal he cooling kam he kya prolem hola piz list
Suction pressure 120 se 140 Psig hona chahye
Kya problem hoga aafse aafse badrahe
Amp normal 7 amp le rahe sir
@@prakashgautam5676 suction pressure agar 140 se zyada hota rahega, to cooling km hoti jayegi
Ok bt suction kyu badrahe sir
Very Good Explain Of HP/LP Switch ...❤️👌
Thanks Dear brother for your valuable comments ❤️
Nice
Thanks
Good sir
Thanks Dear ❤️
Sir expension valve me ice aana kya kya reason hoga list pathaiyana sir piz
@@prakashgotame8875
(i)Less refrigerant in Evaporator
(ii) oil choke in TXV
(iii) TXV orifice filter block
(iv) TXV low pressure screw adjustment
OK thank u sir