R-32 Vs R-410A || Compressors Pressure Difference

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 88

  • @shuaibgul247
    @shuaibgul247 3 месяца назад +2

    بہت خوب ۔ مفید انفرمیشن ہے ۔
    کل آر 32 کے یونٹ کے دھماکہ حوالہ سے دو وڈیو دیکھیں ۔ دونوں کی آراء مختلف تھیں۔ لیکن انداز صرف ریٹنگ بڑھانے والا تھا۔ میں تعلق ایچ وی اے سی سے رہا ہے۔ اس لیے ان کے ہنگامہ خیز بیان سے مطمئن نہیں ہوا ۔ آج آپ کی وڈیو دیکھ کر حقیقت عیاں ہو گئی

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@shuaibgul247 shukarya Janab ❤️

  • @qpkhalid
    @qpkhalid 2 месяца назад +1

    I agreed, very much informative vedio, bcz which information has given may check from Google. In this case every technician should have this much knowledge, bcz mostly technicians are such practical knowledge don't have, and day to day changes every body who are in this refrigeration field they will never makes damages 💯(vecum, Air purging and specially moisture removal) operation is must, their will be no any blast nor damages INSHAALLAH.

  • @shoaibali3506
    @shoaibali3506 6 месяцев назад +1

    Dear sir I hope you are doing well today, my Allah bless you, 🎉🎉🎉🎉🎉

  • @obaidish
    @obaidish 6 месяцев назад +1

    Mashallah very informative video.

  • @84zuba
    @84zuba 3 месяца назад +1

    Brother agar install kerte hue R410 wale AC ko vacuum na kerain to dangerous to nai?

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      R410a dangerous to nhi, Leken Achi cooling result Lene kelie acha vacuum zaroori hai

  • @AzmatKhan-d2n
    @AzmatKhan-d2n 6 месяцев назад +2

    Good job

  • @aunkhan3985
    @aunkhan3985 6 месяцев назад +1

    AOA. Farman bhai AC newly install hua hai. Non inverter hai. Hr baar jb compressor start hota hai tu indoor se high pitch whistling sound aata hai or phir 1 min me chala jata hai. Reason kya hai iski?

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      Wa Alaikumussalam, Dear ho sakta hai ke ye sound fan motor bearings ka ho

    • @aunkhan3985
      @aunkhan3985 6 месяцев назад +1

      @@FKmechofficial Sir jb gas travel krti hai tb aati hai sound almost 30 sec k liay bas.

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      @@aunkhan3985 agar sound gas travel karte waqt hota hai, to pir ye indoor me distributer me koyi capillary tube partially block hai

  • @wasimabs
    @wasimabs 3 месяца назад +1

    Zabardast sir bht acha btaya apne

  • @DanishAli-mf4ly
    @DanishAli-mf4ly 6 месяцев назад +1

    Liquid behtar rahega ya Ave per

  • @prakashgotame8875
    @prakashgotame8875 4 месяца назад +1

    Sir indoor 32 ka and outdoor 410 ka use ho ra haii and r 410 use karke system ok ho saktaya

  • @Sohai1Khan
    @Sohai1Khan 2 месяца назад +1

    Maine new Haier AC liya inverter box packed es Mai R32 gas hy ... Compnay k bande agaye laga liya piples connect kiye... Koi vacuum nai kiya... Unho ne kaha es Mai company k taraf se gas filled ata hy... 5 month se use kr raha hun... Is it safe ?

    • @FKmechofficial
      @FKmechofficial  2 месяца назад

      Dear brother,
      Vacuum hona lazmi hai,
      Agar vacuum nhi kiya hai, to ye 20% dangerous hosakta hai...
      Matlab 80% safe hai...
      Kyunke koyi bhi AC yun hi nhi dhamaka karta hai balke JB AC me koyi unbalanced conditions paida ho jaye tab blast ke chances paida ho jate hain

    • @Sohai1Khan
      @Sohai1Khan 2 месяца назад

      @@FKmechofficial Pata nahe Haier Company k Mechanic Kyun vacuum nahe karte new installation mai... Kpk mai sab logo aise lagate hai

    • @Sohai1Khan
      @Sohai1Khan 2 месяца назад

      @@FKmechofficial Jab se yeh blast ka news aya tabse maine us dealer KO call kiya.. Usne kaha k ap fikar na karo. Maine 3000 ac sold kiye sab yahi company wale lagatay hy.. Aj tak koi masla nahe aya hy... Khair mai kal wo Mechanic se call pe bat karta hun wo kya kehta hy.... Mai UAE mai tha waha non inverter Ac LAga tha .. Ek din pipe leak howa Ac wala agaya pipe theek kiya gas dala.. Vacuum kiya nai. 2 saal se 24 hours on rehta hy... Confused hun

    • @Sohai1Khan
      @Sohai1Khan 2 месяца назад

      @@FKmechofficial Jab se yeh blast ka news aya tabse maine us dealer KO call kiya.. Usne kaha k ap fikar na karo. Maine 3000 ac sold kiye sab yahi company wale lagatay hy.. Aj tak koi masla nahe aya hy... Khair mai kal wo Mechanic se call pe bat karta hun wo kya kehta hy.... Mai UAE mai tha waha non inverter Ac LAga tha .. Ek din pipe leak howa Ac wala agaya pipe theek kiya gas dala.. Vacuum kiya nai. 2 saal se 24 hours on rehta hy... Confused hun

  • @umairanwaar174
    @umairanwaar174 3 месяца назад +1

    Sir mene new ac liya hai midea ka r32 gas wala or 6 feet pipe extend kiya hai, technician vacuum nahi koya bas 1 side open kar k run kiya hai or pipe thanda honay k baad gas on ki hai. Ab main kia karon guide kardain qk jesa apnay kaha ye explosive hai tou kiya main gas change karsakta hon r32 ki jagah r410 dalwadon qk compressor tou t3 hai

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      Brother technician ko vacuum karna chahye the, but ab unit ko service, maintenance carefully proper time se karte rahen. Taaake unit me koyi unbalanced conditions na baaaane

    • @umairanwaar174
      @umairanwaar174 3 месяца назад +1

      @@FKmechofficial kiya main r410 dalwa sakta hon??

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@umairanwaar174 yes of course, but technically teek nhi hai

    • @umairanwaar174
      @umairanwaar174 3 месяца назад +1

      @@FKmechofficial I didn't get it clearly. I can run but technically theek nahi hai means mujhe nahi karna chahiye? Can you please explain the technical reason? it would help me a lot since it is explosive and the technician didn't vacuum it so it's become a very big concern for me. I appreciate your prompt response sir.

    • @ZeeshanZeeshan-ib1mg
      @ZeeshanZeeshan-ib1mg 3 месяца назад

      ​@@umairanwaar174same problem facing

  • @dipanjanroy5469
    @dipanjanroy5469 6 месяцев назад +2

    Can u tell me why casette / VRF AC comes with R410A and not R32.
    For eg :
    O general 1.5 TON and 2 ton comes with r32 gas but 2.5 ton and 3 ton is coming with R410A...
    Mitsubishi heavy duty are generally coming with R410A.

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      R32 is not yet applicable in higher capacity air conditioner units,
      Because it has explosiveness character whenever It is miss calculated by a technician during cycle assembling.
      While R410A is safe

    • @dipanjanroy5469
      @dipanjanroy5469 6 месяцев назад +1

      @@FKmechofficial asked many technicians nobody could answer this. Thnx for the info

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      @@dipanjanroy5469 here you will get every answer Insha Allah

  • @shoaibali3506
    @shoaibali3506 6 месяцев назад +2

    Dear sir r22 capillary pressure drop is 65 and r410a capillary pressure drop is i think 52 ?? , please tell us what is Capillary pressure drop of r32???

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      R22 drop is 50 ~ to 60 Psi,
      R410A drop is 75 to 80 psi,
      R32 is 65 to 70 Psi

  • @SyedRaza-q4q
    @SyedRaza-q4q 4 месяца назад

    Dear Engr Sb, I am buying new AC from Market.. Looking forward to Purchase Non.Inverter heat and cool as I will put this AC in Drawing room.. Do you recommend buying non.inverter 2 tons or should I go for 1.5tons inverter? is my investment future safe with Non.inverter? my room size is 15x27.. mazeed ye k non.inverter brand new k andar i have only R32 options whereas inverter options may R410a mil rahi hai abhi bhi... please help as it is lot of money alomst 200k..

    • @FKmechofficial
      @FKmechofficial  4 месяца назад

      Dear where is your location ?
      Your AC type & capacity depends location's climate ?

  • @manjeetsingh.lohara1654
    @manjeetsingh.lohara1654 3 месяца назад +1

    ❤very use full information bro

  • @RafiUsmani-44
    @RafiUsmani-44 3 месяца назад

    Sir main na 5 din pehla haier ka thunder model lia hai us ma r32 ha ab guide krain sir

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      Kisi ache professional technician se install karo bhai

    • @Sohai1Khan
      @Sohai1Khan 2 месяца назад

      Jis dealer se liya hy Haier company wala banda install karega

  • @nadeembeylim3926
    @nadeembeylim3926 6 месяцев назад +1

    Mashallah lndia Mohammad Nadeem Beylim

  • @zainalimughal10
    @zainalimughal10 3 месяца назад +1

    Dear Sir, Ager R410A leak ho rahi ho to iska koi nuqsan to nahi? Is main koi blast hone ka khatra to nahi hota? Please zaror bta dain. Jazakallah

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@zainalimughal10 agar bahut zyada leak ho awr room ait tight band ho pir sans lene ka masla Aasakta hai,
      Leken blast ka issue nhi Aasakta

    • @zainalimughal10
      @zainalimughal10 3 месяца назад +1

      @@FKmechofficial Jazakallah

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@zainalimughal10 Barak Allah

  • @shoaibali3506
    @shoaibali3506 6 месяцев назад +1

    Well done good job sir, please tell us sir compressor data sheet kaise nikaalte hain

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      Note to next video

    • @casforindia
      @casforindia 2 месяца назад +1

      Very informative in simple manner. All the best brother from India

    • @FKmechofficial
      @FKmechofficial  2 месяца назад

      @casforindia Thanks Dear

  • @shuaibgul247
    @shuaibgul247 3 месяца назад +1

    Subscribed your channel.

  • @84zuba
    @84zuba 3 месяца назад +1

    Brother agar R32 ki leak ho to blast possible he?

    • @FKmechofficial
      @FKmechofficial  3 месяца назад +1

      @@84zuba no brother,
      Leken R32 Leak hone ki surat me fire/ flame nhi chalna chahye...

    • @84zuba
      @84zuba 3 месяца назад

      Main ne utube pe dekha hai, kuch log fire lighter se R32 ko flame de rahe hain, but wo fire nai pakar rahi

  • @infopoint3836
    @infopoint3836 4 месяца назад +1

    A a jinab
    Meri softy machin _4 ke aagay temprature show nhi kr rahi aur ratio 65 ke aagay jati nhi ...ap meharbani kr k solution bataye( R410A)

  • @hammadusman9436
    @hammadusman9436 3 месяца назад

    Sir mera non inverter ac hai hair company ka 2 saal phelay liya tha is may r32 gas dali huhi hai...kiya main is may r410a gas dalwado koi masla tu nahi hoga..plz ap batadey

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@hammadusman9436 brother charge kr sakte ho leken charge Karni nhi chahye,,,
      Issslie ke cooling effect me bhi tora sa faraq Aajata hai Awr compressor life pe bhi effect parta hai

    • @hammadusman9436
      @hammadusman9436 3 месяца назад

      ​@@FKmechofficialtu main is may r32 ka compressor nikalkay r410a ka compressor dalwado...ya ap koi dosra solution batadey takay cooling bhi achi ho..compreesor ki life ko bhi nuqsan na ho

    • @hammadusman9436
      @hammadusman9436 3 месяца назад

      Please bataday solution😊

    • @hammadusman9436
      @hammadusman9436 3 месяца назад

      ????

    • @Sohai1Khan
      @Sohai1Khan 2 месяца назад

      No you can't fill R410 in R32 unit because that compresur is made for r32... Not for r410...

  • @owaisali7677
    @owaisali7677 4 месяца назад +1

    Aslam u alykum sir aksr log bolty ah R32 khtrnak ha khin blast huwa ah ac ma qk ma ny Kenwood liya ha us ma R32 gas h plz reply

    • @FKmechofficial
      @FKmechofficial  4 месяца назад

      Yes dangerous hai, leken agar care ke sath install awr use kiya jaye...
      Pir no problem

    • @Sohai1Khan
      @Sohai1Khan 2 месяца назад

      ​@@FKmechofficialcare kaisa care?

  • @zubairhadi261
    @zubairhadi261 6 месяцев назад +1

    Awesome

  • @muzammalbaig
    @muzammalbaig 3 месяца назад +2

    technician usually purge kr k install krtay hen. woh vacuum nhi krtay so air inside reh janay ka imkan rehta hah. this is very very bad of our technicians.

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      @@muzammalbaig of course yes, you are right brother ❤️

  • @dipanjanroy5469
    @dipanjanroy5469 6 месяцев назад +3

    Can u tell me why R32 machine outdoor is lighter and smaller but R410A outdoor unit much bigger and heavier ?
    Is it due to heat absorption capabilities?

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      R32 is more capable than R410A, that's why little bit smaller R32 unit is equal in capacity to little bit bigger R410A.
      The components in R32 are little bit lighter than R410A

    • @dipanjanroy5469
      @dipanjanroy5469 6 месяцев назад +1

      @@FKmechofficial thnx for the info... U r quite knowledgeable sir.

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      @@dipanjanroy5469 you are welcome Dear ❣️

  • @shoaibali3506
    @shoaibali3506 6 месяцев назад +2

    ❤❤❤❤❤❤

  • @DanishAli-mf4ly
    @DanishAli-mf4ly 6 месяцев назад

    Dear teacher g apne ye ni btaya ke r32 ko or 410 ko kese charg krna he

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад +1

      Thanks for highlighting,
      R32 ko ap vapor ya liquid dono halat me charge kar sakte ho, jabke
      R410A ko only liquid halat me...

    • @DanishAli-mf4ly
      @DanishAli-mf4ly 6 месяцев назад +1

      Ustad g or jo r600a he usko frig me liquid charge karna chahie ya avepar

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад +1

      @@DanishAli-mf4ly R600A liquid charge

  • @nayanjagirdar8408
    @nayanjagirdar8408 6 месяцев назад +1

    👌👍